Prediction of hip fracture can be significantly improved by a single biomedical indicator.

Abstract:

:Femoral neck fractures are a relevant clinical and social problem. The aim of this study was to improve the prediction of patients at-risk of femoral neck fracture with respect to the current densitometric-based methods. In particular, finite element models were used to assess the prediction accuracy obtained by combining together data from the bone density distribution, the proximal femur anatomy, and the fall-related loading conditions. Two-dimensional finite element models were developed based on dual energy x-ray absorptiometry data. A population of 93 elder Caucasian women (half of them reporting a femoral neck fracture) were retrospectively classified both using the standard clinical protocol and Bayes' linear classifiers. This study showed that the bone mineral density in the femoral neck region dominated the fracture event (65% accuracy). Adding the subject's height and the neck-shaft angle to the bone density increased the accuracy to 77%. The classification accuracy was further improved to 82% by including the peak principal tensile strain obtained from the finite element analyses. This research demonstrated that adding one single biomechanical indicator to the standard clinical measurements improves the identification of patients at-risk of femoral neck fracture.

journal_name

Ann Biomed Eng

authors

Testi D,Viceconti M,Cappello A,Gnudi S

doi

10.1114/1.1495866

subject

Has Abstract

pub_date

2002-06-01 00:00:00

pages

801-7

issue

6

eissn

0090-6964

issn

1573-9686

journal_volume

30

pub_type

杂志文章
  • A Novel High-Resolution Method for the Respiration Rate and Breathing Waveforms Remote Monitoring.

    abstract::A search for robust noninvasive methods permitting to discern the respiration subtle peculiarities in mammals is a topical issue. A novel approach called "sorption-enhanced infrared thermography" (SEIRT), helping to solve this problem, is described. Its benefits spring from the integration of the infrared thermography...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-018-2018-6

    authors: Vainer BG

    更新日期:2018-07-01 00:00:00

  • A novel approach to track fetal movement using multi-sensor magnetocardiographic recordings.

    abstract::Changes in fetal magnetocardiographic (fMCG) signals are indicators for fetal body movement. We propose a novel approach to reliably extract fetal body movements based on the field strength of the fMCG signal independent of its frequency. After attenuating the maternal MCG, we use a Hilbert transform approach to ident...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-0231-z

    authors: Govindan RB,Vairavan S,Ulusar UD,Wilson JD,McKelvey SS,Preissl H,Eswaran H

    更新日期:2011-03-01 00:00:00

  • Predictive Virtual Patient Modelling of Mechanical Ventilation: Impact of Recruitment Function.

    abstract::Mechanical ventilation is a life-support therapy for intensive care patients suffering from respiratory failure. To reduce the current rate of ventilator-induced lung injury requires ventilator settings that are patient-, time-, and disease-specific. A common lung protective strategy is to optimise the level of positi...

    journal_title:Annals of biomedical engineering

    pub_type: 临床试验,杂志文章

    doi:10.1007/s10439-019-02253-w

    authors: Morton SE,Knopp JL,Chase JG,Möller K,Docherty P,Shaw GM,Tawhai M

    更新日期:2019-07-01 00:00:00

  • Hydraulic Conductivity of Smooth Muscle Cell-Initiated Arterial Cocultures.

    abstract::The purpose of the study was to examine the effects of arterial coculture conditions on the transport properties of several in vitro endothelial cell (EC)-smooth muscle cell (SMC)-porous filter constructs in which SMC were grown to confluence first and then EC were inoculated. This order of culturing simulates the env...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1421-5

    authors: Mathura RA,Russell-Puleri S,Cancel LM,Tarbell JM

    更新日期:2016-05-01 00:00:00

  • A Battery-Powered Ankle Exoskeleton Improves Gait Mechanics in a Feasibility Study of Individuals with Cerebral Palsy.

    abstract::Neuromuscular impairment associated with cerebral palsy (CP) often leads to life-long walking deficits. Our goal was to evaluate the ability of a novel untethered wearable ankle exoskeleton to reduce the severity of gait pathology from CP. In this clinical feasibility study of five individuals with CP, we used instrum...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-019-02237-w

    authors: Lerner ZF,Harvey TA,Lawson JL

    更新日期:2019-06-01 00:00:00

  • MEG connectivity analysis in patients with Alzheimer's disease using cross mutual information and spectral coherence.

    abstract::Alzheimer's disease (AD) is an irreversible brain disorder which represents the most common form of dementia in western countries. An early and accurate diagnosis of AD would enable to develop new strategies for managing the disease; however, nowadays there is no single test that can accurately predict the development...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-0155-7

    authors: Alonso JF,Poza J,Mañanas MA,Romero S,Fernández A,Hornero R

    更新日期:2011-01-01 00:00:00

  • Fecobionics: A Novel Bionics Device for Studying Defecation.

    abstract::During defecation, solid, semisolid or liquid stools are eliminated via the anus in a complex physiological process. Up to 25% of the population are affected by anorectal disorders that are poorly recognized and treated. We developed a new bionics device, a simulated stool named Fecobionics, to replace several current...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-018-02149-1

    authors: Sun D,Huang Z,Zhuang Z,Ma Z,Man LK,Liao D,Gregersen H

    更新日期:2019-02-01 00:00:00

  • Multiscale Modeling in the Clinic: Drug Design and Development.

    abstract::A wide range of length and time scales are relevant to pharmacology, especially in drug development, drug design and drug delivery. Therefore, multiscale computational modeling and simulation methods and paradigms that advance the linkage of phenomena occurring at these multiple scales have become increasingly importa...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/s10439-016-1563-0

    authors: Clancy CE,An G,Cannon WR,Liu Y,May EE,Ortoleva P,Popel AS,Sluka JP,Su J,Vicini P,Zhou X,Eckmann DM

    更新日期:2016-09-01 00:00:00

  • Multidirectional pelvic floor muscle strength measurement.

    abstract::Pelvic floor muscle (PFM) strength measurement provides useful information for the study of pelvic floor dysfunctions. Vaginal digital palpation, intravaginal pressure measurements, and the use of a dynamometric speculum represent currently available clinical methods for evaluating PFM strength. However, none of these...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-009-9728-8

    authors: Saleme CS,Rocha DN,Del Vecchio S,Silva Filho AL,Pinotti M

    更新日期:2009-08-01 00:00:00

  • Fetal Transcatheter Trileaflet Heart Valve Hemodynamics: Implications of Scaling on Valve Mechanics and Turbulence.

    abstract::The scarcity of data available on the best approach for pulmonary fetal valve replacement or implantation necessitate an investigation on whether practices using adult transcatheter valves could be translated to fetal applications. The objective of this study is to evaluate the hemodynamic characteristics and the turb...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02475-3

    authors: Hatoum H,Gooden S,Heitkemper M,Blum KM,Zakko J,Bocks M,Yi T,Wu YL,Wang Y,Breuer CK,Dasi LP

    更新日期:2020-06-01 00:00:00

  • Functionalized biomicroelectromechanical systems sensors for force response study at local adhesion sites of single living cells on substrates.

    abstract::We present a method of measuring force response of a single living cell, attached to a substrate, in situ, by a functionalized microelectromechanical systems sensor that applies local deformation on the cell. The sensor is a single crystal silicon microcantilever beam with prescribed shape and geometry, and is coated ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1591189

    authors: Saif MT,Sager CR,Coyer S

    更新日期:2003-09-01 00:00:00

  • Conductance method for the measurement of cross-sectional areas of the aorta.

    abstract::A modified conductance method to determine the cross-sectional areas (CSAs) of arteries in piglets was evaluated in vivo. The method utilized a conductance catheter having four electrodes. Between the outer electrodes an alternating current was applied and between the inner electrodes the induced voltage difference wa...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.219

    authors: Kornet L,Jansen JR,Gussenhoven EJ,Hardeman MR,Hoeks AP,Versprille A

    更新日期:1999-03-01 00:00:00

  • Developing a quantitative measurement system for assessing heterotopic ossification and monitoring the bioelectric metrics from electrically induced osseointegration in the residual limb of service members.

    abstract::Poor prosthetic fit is often the result of heterotopic ossification (HO), a frequent problem following blast injuries for returning service members. Osseointegration technology offers an advantage for individuals with significant HO and poor socket tolerance by using direct skeletal attachment of a prosthesis to the d...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-0050-2

    authors: Isaacson BM,Stinstra JG,MacLeod RS,Pasquina PF,Bloebaum RD

    更新日期:2010-09-01 00:00:00

  • Stress relaxation preconditioning of porcine aortic valves.

    abstract::In uniaxial tensile testing, load preconditioning is used to generate repeatable load/elongation curves and set a "reference state" for subsequent tensile tests. We have observed however, that for porcine aortic valve (PAV) tissues, preconditioning does not lead to repeatable stress relaxation curves. We thus investig...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1023/b:abme.0000019176.49650.19

    authors: Carew EO,Garg A,Barber JE,Vesely I

    更新日期:2004-04-01 00:00:00

  • Fibroblast morphology on dynamic softening of hydrogels.

    abstract::Despite cellular environments having dynamic characteristics, many laboratories utilized static polyacrylamide hydrogels to study the ECM-cell relationship. To attain a more in vivo like environment, we have developed a dynamic, DNA-crosslinked hydrogel (DNA gel). Through the controlled delivery of DNA, we can tempora...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-011-0483-2

    authors: Previtera ML,Trout KL,Verma D,Chippada U,Schloss RS,Langrana NA

    更新日期:2012-05-01 00:00:00

  • An in vitro evaluation of the impact of eccentric deployment on transcatheter aortic valve hemodynamics.

    abstract::Patients with aortic stenosis present with calcium deposits on the native aortic valve, which can result in non-concentric expansion of Transcatheter Aortic Valve Replacement (TAVR) stents. The objective of this study is to evaluate whether eccentric deployment of TAVRs lead to turbulent blood flow and blood cell dama...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-014-1008-6

    authors: Gunning PS,Saikrishnan N,McNamara LM,Yoganathan AP

    更新日期:2014-06-01 00:00:00

  • LDL decreases the membrane compliance and cell adhesion of endothelial cells under fluid shear stress.

    abstract::Atherosclerosis is an inflammatory disease of large and medium sized arteriole walls that is precipitated by elevated levels of low-density lipoprotein (LDL) cholesterol in the blood. However, the mechanisms that lead to the initiation of atherosclerosis are not fully understood. In this study, endothelial cells (ECs)...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-012-0677-2

    authors: Wei D,Chen Y,Tang C,Huang H,Liu L,Wang Z,Li R,Wang G

    更新日期:2013-03-01 00:00:00

  • Acoustic Emissions as a Non-invasive Biomarker of the Structural Health of the Knee.

    abstract::The longitudinal assessment of joint health is a long-standing issue in the management of musculoskeletal injuries. The acoustic emissions (AEs) produced by joint articulation could serve as a biomarker for joint health assessment, but their use has been limited by a lack of mechanistic understanding of their creation...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-019-02333-x

    authors: Whittingslow DC,Jeong HK,Ganti VG,Kirkpatrick NJ,Kogler GF,Inan OT

    更新日期:2020-01-01 00:00:00

  • Tensile strain as a regulator of mesenchymal stem cell osteogenesis.

    abstract::A role for mechanical stimulation in the control of cell fate has been proposed and mechanical conditioning of mesenchymal stem cells (MSCs) is of interest in directing MSC behavior for tissue engineering applications. This study investigates strain-induced differentiation and proliferation of MSCs, and investigates t...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-9979-4

    authors: Kearney EM,Farrell E,Prendergast PJ,Campbell VA

    更新日期:2010-05-01 00:00:00

  • Bimodal analysis of mammary epithelial cell migration in two dimensions.

    abstract::Cell migration paths of mammary epithelial cells (expressing different versions of the promigratory tyrosine kinase receptor Her2/Neu) were analyzed within a bimodal framework that is a generalization of the run-and-tumble description applicable to bacterial migration. The mammalian cell trajectories were segregated i...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-008-9592-y

    authors: Potdar AA,Lu J,Jeon J,Weaver AM,Cummings PT

    更新日期:2009-01-01 00:00:00

  • Hemodynamics in a Pediatric Ascending Aorta Using a Viscoelastic Pediatric Blood Model.

    abstract::Congenital heart disease is the leading cause of infant death in the United States with over 36,000 newborns affected each year. Despite this growing problem there are few mechanical circulatory support devices designed specifically for pediatric and neonate patients. Previous research has been done investigating pedi...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1370-z

    authors: Good BC,Deutsch S,Manning KB

    更新日期:2016-04-01 00:00:00

  • A piconewton force transducer and its application to measurement of the bending stiffness of phospholipid membranes.

    abstract::The bending stiffness of a phospholipid bilayer (Kc) was measured by forming thin bilayer cylinders (tethers) from giant phospholipid vesicles. Based on the balance of forces, the tether force was expected to be proportional to the square root of the membrane tension, with a constant of proportionality containing Kc. ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02684228

    authors: Heinrich V,Waugh RE

    更新日期:1996-09-01 00:00:00

  • Parametric comparisons of intracranial mechanical responses from three validated finite element models of the human head.

    abstract::A number of human head finite element (FE) models have been developed from different research groups over the years to study the mechanisms of traumatic brain injury. These models can vary substantially in model features and parameters, making it important to evaluate whether simulation results from one model are read...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-013-0907-2

    authors: Ji S,Ghadyani H,Bolander RP,Beckwith JG,Ford JC,McAllister TW,Flashman LA,Paulsen KD,Ernstrom K,Jain S,Raman R,Zhang L,Greenwald RM

    更新日期:2014-01-01 00:00:00

  • Why, When, Who, What, How, and Where for Trainees Writing Literature Review Articles.

    abstract::Literature review articles provide a valuable mechanism for remaining informed amidst an ever-increasing body of scientific work. Condensing current advances into this disseminatable form is a critical activity for any research trainee. To systematize this multifaceted process, we present the "why, when, who, what, ho...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-019-02290-5

    authors: Koons GL,Schenke-Layland K,Mikos AG

    更新日期:2019-11-01 00:00:00

  • Do Head Injury Biomechanics Predict Concussion Clinical Recovery in College American Football Players?

    abstract::Identifying the associations between head impact biomechanics and clinical recovery may inform better head impact monitoring procedures and identify athletes who may benefit from early treatments aimed to enhance recovery. The purpose of this study was to test whether head injury biomechanics are associated with clini...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02658-y

    authors: Mihalik JP,Chandran A,Powell JR,Roby PR,Guskiewicz KM,Stemper BD,Shah AS,Rowson S,Duma S,Harezlak J,Riggen L,Broglio SP,McAllister TW,McCrea M,CARE Consortium Investigators.

    更新日期:2020-11-01 00:00:00

  • The effect of head rotation on the geometry and hemodynamics of healthy vertebral arteries.

    abstract::The geometric and hemodynamic characteristics of the left and right vertebral arteries (LVA, RVA) of six healthy volunteers were investigated for the supine (S) and the prone position (P) a common sleeping posture with head rotation. MRI images were used to reconstruct the subject specific three-dimensional solid mode...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1340-5

    authors: Aristokleous N,Seimenis I,Georgiou GC,Nicolaides A,Anayiotos AS

    更新日期:2015-06-01 00:00:00

  • Contourlet-based features for computerized tumor detection in capsule endoscopy images.

    abstract::This article presents a computer-aided detection system for capsule endoscopy (CE) images using contourlet-based color textural features to recognize tumors in the digestive tract. As tumor exhibits rich information in color texture, a novel color texture feature based on contourlet transform is proposed to describe c...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-011-0380-8

    authors: Li B,Meng MQ

    更新日期:2011-12-01 00:00:00

  • Myofilament kinetics in isometric twitch dynamics.

    abstract::To better understand the relationship between kinetic processes of contraction and the dynamic features of an isometric twitch, studies were conducted using a mathematical model that included: (1) kinetics of cross bridge (XB) cycling; (2) kinetics of thin filament regulatory processes; (3) serial and feedback interac...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1366669

    authors: Campbell KB,Razumova MV,Kirkpatrick RD,Slinker BK

    更新日期:2001-05-01 00:00:00

  • Hemoglobin glycation rate constant in non-diabetic Individuals.

    abstract::The objectives were as follows: (1) estimating mean value of the overall hemoglobin glycation rate constant (k); (2) analyzing inter-individual variability of k; (3) verifying ability of the hemoglobin A1c (HbA1c) formation model to predict changes of HbA1c during red blood cells cultivation in vitro and to reproduce ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-011-0366-6

    authors: Ladyżyński P,Wójcicki JM,Bąk MI,Sabalińska S,Kawiak J,Foltyński P,Krzymień J,Karnafel W

    更新日期:2011-11-01 00:00:00

  • A novel left heart simulator for the multi-modality characterization of native mitral valve geometry and fluid mechanics.

    abstract::Numerical models of the mitral valve have been used to elucidate mitral valve function and mechanics. These models have evolved from simple two-dimensional approximations to complex three-dimensional fully coupled fluid structure interaction models. However, to date these models lack direct one-to-one experimental val...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-012-0651-z

    authors: Rabbah JP,Saikrishnan N,Yoganathan AP

    更新日期:2013-02-01 00:00:00