Abstract:
:We present a method of measuring force response of a single living cell, attached to a substrate, in situ, by a functionalized microelectromechanical systems sensor that applies local deformation on the cell. The sensor is a single crystal silicon microcantilever beam with prescribed shape and geometry, and is coated by a thin layer of fibronectin. It is brought in contact with a cell to form adhesion cites, and is then moved by a piezoactuator to deform the cell locally. The force is transmitted from the adhesion site(s) on the cantilever to the sites on the substrate through the cytoskeleton. The interaction force between the cell and the cantilever is measured from the deformation of the cantilever and its spring constant, which can be obtained by several independent means. The force and the cell deformation can be 10 s of nano-Newtons and micrometers, respectively. We demonstrate the method using two families of force sensors with spring constants of 18 and 0.4 nN/microm. Several cells, endothelial and fibroblast, are deformed by tens of micrometers until the adhesion sites failed. Their force-deformation response shows strong linearity. Several possible mechanisms are discussed to explain the linear response.
journal_name
Ann Biomed Engjournal_title
Annals of biomedical engineeringauthors
Saif MT,Sager CR,Coyer Sdoi
10.1114/1.1591189subject
Has Abstractpub_date
2003-09-01 00:00:00pages
950-61issue
8eissn
0090-6964issn
1573-9686journal_volume
31pub_type
杂志文章abstract::Tendon stem cells (TSCs) may be used to effectively repair or regenerate injured tendons. However, the fates of TSCs once implanted in vivo remain unclear. This study was aimed to determine the feasibility of labeling TSCs with super-paramagnetic iron oxide (SPIO) nano-particles to track TSCs in vivo using MRI. Rabbit...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-013-0802-x
更新日期:2013-10-01 00:00:00
abstract::Bending stiffness of passive-dynamic ankle-foot orthoses (PD-AFOs) is a functional characteristic thought to restore lost ankle function due to weakened plantar flexors. However, lower extremity impairment profiles of patients are seldom limited to plantar flexion weakness, and PD-AFO characteristics often influence g...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-014-1067-8
更新日期:2015-02-01 00:00:00
abstract::We have studied the dependence of conduction velocity (theta) on extracellular potassium concentration ([K+]o) in a model of one-dimensional conduction using an idealized strand of human atrial cells. Elevated [K+]o in the 5-20 mM range shifts the resting potential (Vrest) in the depolarizing direction and reduces inp...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1114/1.1308489
更新日期:2000-08-01 00:00:00
abstract::A numerical single path model of respiratory gas exchange with distributed alveolar gas sources was used to estimate the anatomical changes in small peripheral airways such as occur in chronic obstructive pulmonary diseases (COPD). A previous sensitivity analysis of the single path model showed that decreasing total a...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/BF02368236
更新日期:1994-05-01 00:00:00
abstract::This study presents a new steady-state visual evoked potential (SSVEP)-based brain computer interface (BCI). SSVEPs, induced by phase-tagged flashes in eight light emitting diodes (LEDs), were used to control four cursor movements (up, right, down, and left) and four button functions (on, off, right-, and left-clicks)...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-010-9964-y
更新日期:2010-07-01 00:00:00
abstract::Normal physiological mechanical forces cause constant tissue renewal in aortic valve leaflets (AVL) while altered mechanical forces incite changes in their structural and biological properties. The current study aims at characterizing the remodeling properties of AVL subjected to cyclic circumferential stretch in a st...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-006-9167-8
更新日期:2006-11-01 00:00:00
abstract::This project was undertaken to establish if the integral circulation had any effects upon the mechanical behavior of bone. The influence of blood flow in the rabbit tibia on the strain induced at the bone surface when under load was assessed. Recordings were taken from three adult and three immature New Zealand White ...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/BF02390377
更新日期:1994-03-01 00:00:00
abstract::In uniaxial tensile testing, load preconditioning is used to generate repeatable load/elongation curves and set a "reference state" for subsequent tensile tests. We have observed however, that for porcine aortic valve (PAV) tissues, preconditioning does not lead to repeatable stress relaxation curves. We thus investig...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1023/b:abme.0000019176.49650.19
更新日期:2004-04-01 00:00:00
abstract::The effects of facet wiring procedure commonly used for stabilizing cervical spines after laminectomy or bilateral facet dislocation on the motion behavior of whole cervical spines are investigated using a Selspot II system. A fresh human ligamentous intact specimen was potted at T1/T2 vertebra and clinically relevant...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/BF02368022
更新日期:1989-01-01 00:00:00
abstract::This study was undertaken to investigate the possible origin of some cutaneously recorded higher frequency electrogastrographic signals. Computer modeling of gastric electrical uncoupling was performed using previously described conoidal dipole model. Cutaneous electrogastrograms were simulated after uncoupling was in...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:
更新日期:1997-11-01 00:00:00
abstract::Spike discharge patterns showing intrinsic oscillations (IOs) have been reported in units in the dorsal cochlear nucleus (DCN) of the decerebrate cat. These oscillations are related to the regularity of a unit's discharge rate and may be important for pitch perception. A DCN unit's regularity can be affected by severa...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1114/1.96
更新日期:1998-05-01 00:00:00
abstract::Further understanding of the mechanical deformation and tear behavior of kidney during suturing helps to enhance surgical task execution that requires fine suture manipulation. This paper aims to develop a model to describe the relationship between the tensile force acting on suture line and the resulted kidney deform...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-012-0722-1
更新日期:2013-04-01 00:00:00
abstract::Cardiac MRI (CMR) techniques offer non-invasive visualizations of cardiac morphology and function. However, imaging can be time-consuming and complex. Seismocardiography (SCG) measures physical vibrations transmitted through the chest from the beating heart and pulsatile blood flow. SCG signals can be acquired quickly...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-020-02491-3
更新日期:2020-06-01 00:00:00
abstract::Mitral valve regurgitation (MVR) is common in patients receiving left ventricular assist device (LVAD) support, however the haemodynamic effect of MVR is not entirely clear. This study evaluated the haemodynamic effect of MVR with LVAD support and the influence of inflow cannulation site and LVAD speed modulation. Lef...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-016-1579-5
更新日期:2016-09-01 00:00:00
abstract::The aim of this study was to develop an empirical model of parameter-based gait data, based on an artificial neural network and a genetic algorithm, for the assessment of patients after ankle arthrodesis. Ground reaction force vectors were measured by force platforms during level walking. Nine force parameters express...
journal_title:Annals of biomedical engineering
pub_type: 临床试验,杂志文章
doi:10.1114/1.1342053
更新日期:2001-01-01 00:00:00
abstract::This paper presents two related methods for registering an image of an anatomical object with data from sensors arranged on the object. One method is described with reference to a test case involving a rectangular electrode plaque disposed on a heart surface, which is imaged with MRI. Data from the electrodes is fused...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-007-9350-6
更新日期:2007-10-01 00:00:00
abstract::A computer-based feedback system has been developed to adjust the concentration of oxygen in the inspired gas of a patient under artificial respiration. The system uses a proportional plus integral controller and feedback of arterial oxygen saturation to adjust the inspired oxygen fraction. The effectiveness of the co...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/BF02368173
更新日期:1992-01-01 00:00:00
abstract::Conventional nanoporous hydrogels often lead to slow cartilage deposition by MSCs in 3D due to physical constraints and requirement for degradation. Our group has recently reported macroporous gelatin microribbon (μRB) hydrogels, which substantially accelerate MSC-based cartilage formation in vitro compared to convent...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-020-02522-z
更新日期:2020-07-01 00:00:00
abstract::We and others have shown that changing surface characteristics of the spacer implanted during the first Masquelet stage alters some aspects of membrane development. Previously we demonstrated that titanium (TI) spacers create membranes that are better barriers to movement of solutes > 70 kDa in size than polymethyl me...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-018-02137-5
更新日期:2019-01-01 00:00:00
abstract::Changes in fetal magnetocardiographic (fMCG) signals are indicators for fetal body movement. We propose a novel approach to reliably extract fetal body movements based on the field strength of the fMCG signal independent of its frequency. After attenuating the maternal MCG, we use a Hilbert transform approach to ident...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-010-0231-z
更新日期:2011-03-01 00:00:00
abstract::Local hemodynamics are an important factor in atherosclerosis, from the development of early lesions, to the assessment of stroke risk, to determining the ultimate fate of a mature plaque. Until recently, our understanding of arterial fluid dynamics and their relationship to atherosclerosis was limited by the use of i...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章,评审
doi:10.1114/1.1467679
更新日期:2002-04-01 00:00:00
abstract::Correct development of neuronal tracts requires the coordination of multiple permissive and inhibitory signals. By generating an in vitro microenvironment using soft lithography and microfluidic techniques, multiple guidance cues can be presented in a spatially defined way. Here we evaluated how neurites of dorsal roo...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-008-9486-z
更新日期:2008-06-01 00:00:00
abstract::The development of brain interface (BI) technology continues to attract researchers with a wide range of backgrounds and expertise. Though the BI community is committed to accurate and objective evaluation of methods, systems, and technology, the very diversity of the methods and terminology used in the field hinders ...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-005-7706-3
更新日期:2005-11-01 00:00:00
abstract::Pressure ulcer risk assessment might be optimized by incorporating the soft tissue reaction to mechanical loading in the currently used risk assessment scales. Cytokines, like IL-1alpha, IL-1RA, IL-8, and TNF-alpha, might be used to determine this tissue reaction, since they are released after 24 h of mechanical loadi...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-009-9652-y
更新日期:2009-05-01 00:00:00
abstract::Poor prosthetic fit is often the result of heterotopic ossification (HO), a frequent problem following blast injuries for returning service members. Osseointegration technology offers an advantage for individuals with significant HO and poor socket tolerance by using direct skeletal attachment of a prosthesis to the d...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-010-0050-2
更新日期:2010-09-01 00:00:00
abstract::Parameters of physiological models are commonly associated in an input-output experiment with a specific pattern of the system response. This association is often made on an intuitive basis by traditional sensitivity analysis, i.e., by inspecting the variations of model output trajectories with respect to parameter va...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1114/1.207
更新日期:1999-09-01 00:00:00
abstract::The influence of scaffold compliance on blood vessel tissue engineering remains unclear and compliance mismatch issues are important to an in vivo tissue-engineering approach. We have designed and constructed a modular bioreactor system that is capable of imparting pulsatile fluid flow while simultaneously measuring v...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-007-9304-z
更新日期:2007-08-01 00:00:00
abstract::Double-exposure holographic interferometry is a contactless whole-field method. Dimensional changes are visualized as a series of interference fringes overlaid on the holographic image of the femur, where each fringe represents 0.316 micron (half the wavelength of the laser light) of motion. Interferograms for intact ...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/BF02364168
更新日期:1987-01-01 00:00:00
abstract::The purpose of this study is to measure the transmural pressure-cross sectional area relation of micro tubes (240 microns diameter) and to compare the measured perfusion pressure-flow relation with the pressure-flow relation calculated from the experimental pressure-cross sectional area relation. The microtubes are ma...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/BF02368042
更新日期:1989-01-01 00:00:00
abstract::A mathematical model of heat, water and soluble gas exchange in the airways and alveoli was used to predict the location of soluble gas exchange in the lung. A previously published model of heat, water and soluble gas exchange in the airways was improved by incorporating anatomical data on the airway wall to better de...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1114/1.1630600
更新日期:2003-12-01 00:00:00