Geometric and flow features of type B aortic dissection: initial findings and comparison of medically treated and stented cases.

Abstract:

:Uncomplicated acute type B aortic dissections are usually treated medically, but they can become acutely complicated by rapid expansion, rupture and malperfusion syndromes and in the longer term by chronic dilatation and aortic aneurysm formation. The objective of this study is to use computational fluid dynamics reconstructions of type B aortic dissections to compare geometric and haemodynamic factors between the cases selected for medical treatment and the cases selected for thoracic endovascular aortic repair (TEVAR), and to examine whether any of these factors are associated with the outcome of the medically treated group. This study includes eight type B dissection cases, with four in each group. Aortic flow analyses were carried out based on patient-specific anatomy at initial presentation before treatment. Comparisons between the two groups show that the false lumen to true lumen volume ratio is considerably higher in patients selected for TEVAR. Results from the four medically treated cases indicate that the size of the primary entry tear is the key determinant of the false lumen flow rate, which may influence the long-term outcome of medically treated patients. Potential relations between flow related parameters based on initial anatomy and subsequent anatomical changes in the medically treatment group were examined. Our initial findings based on the limited cases are that high relative residence time is a strong predictor of subsequent false lumen thrombosis, whereas pressure difference between the true and false lumen as well as the location of the largest pressure difference may be associated with the likelihood of subsequent aortic expansion.

journal_name

Ann Biomed Eng

authors

Cheng Z,Wood NB,Gibbs RG,Xu XY

doi

10.1007/s10439-014-1075-8

subject

Has Abstract

pub_date

2015-01-01 00:00:00

pages

177-89

issue

1

eissn

0090-6964

issn

1573-9686

journal_volume

43

pub_type

杂志文章
  • Functionalized biomicroelectromechanical systems sensors for force response study at local adhesion sites of single living cells on substrates.

    abstract::We present a method of measuring force response of a single living cell, attached to a substrate, in situ, by a functionalized microelectromechanical systems sensor that applies local deformation on the cell. The sensor is a single crystal silicon microcantilever beam with prescribed shape and geometry, and is coated ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1591189

    authors: Saif MT,Sager CR,Coyer S

    更新日期:2003-09-01 00:00:00

  • Reporter Scaffolds for Clinically Relevant Cell Transplantation Studies.

    abstract::There are a number of cell therapies that are either in clinical trials or moving toward clinical trials, particularly for diseases of the retina. One of the challenges with cell therapies is tracking the status of cells over time. Genetic manipulation can facilitate this, but it can limit the clinical application of ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-019-02393-z

    authors: Bolger M,Groynom R,Bogie K,Lavik E

    更新日期:2020-07-01 00:00:00

  • Simultaneous regulation of hemodynamic and anesthetic states: a simulation study.

    abstract::A model predictive control strategy to simultaneously regulate hemodynamic and anesthetic variables in critical care patients is presented. A nonlinear canine circulatory model, which has been used to study the effect of inotropic and vasoactive drugs on hemodynamic variables, has been extended to include propofol pha...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.255

    authors: Rao RR,Bequette BW,Roy RJ

    更新日期:2000-01-01 00:00:00

  • Numerical validation of MR-measurement-integrated simulation of blood flow in a cerebral aneurysm.

    abstract::This study proposes magnetic resonance (MR)-measurement-integrated (MR-MI) simulation, in which the difference between the computed velocity field and the phase-contrast MRI measurement data is fed back to the numerical simulation. The computational accuracy and the fundamental characteristics, such as steady characte...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-009-9689-y

    authors: Funamoto K,Suzuki Y,Hayase T,Kosugi T,Isoda H

    更新日期:2009-06-01 00:00:00

  • Interaction between high frequency jet ventilation and cardiovascular function.

    abstract::We have studied the interaction of high frequency jet ventilation with cardiovascular pressures and flows. Results in dogs show that the amplitude of all intrathoracic pressures and flows fluctuate with a frequency equal to the difference between the heart rate and ventilator rate. The magnitude of this amplitude vari...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02584287

    authors: Mitzner W,Gioia F,Weinmann GG,Robotham JL,Ehrlich W

    更新日期:1987-01-01 00:00:00

  • Micro-flow visualization of red blood cell-enhanced platelet concentration at sudden expansion.

    abstract::Microscopic steps and crevices are inevitable features within prosthetic blood-contacting devices. This study aimed to elucidate the thrombogenicity of the associated microscopic flow features by studying the transport of fluorescent platelet-sized particles in a suspension of red blood cells (RBCs) flowing through a ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-008-9494-z

    authors: Zhao R,Marhefka JN,Shu F,Hund SJ,Kameneva MV,Antaki JF

    更新日期:2008-07-01 00:00:00

  • Fluid flow-induced calcium response in early or late differentiated osteoclasts.

    abstract::Intracellular calcium oscillation caused by receptor activator of nuclear factor kappa-B ligand has been demonstrated to promote the differentiation of osteoclasts. Osteoclasts are recruited on the surface of trabeculae, and are exposed to fluid flow caused by the deformation of the bone matrix. However, the roles of ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-012-0554-z

    authors: Li P,Hu M,Sun S,Zhang Y,Gao Y,Long M,Huo B,Zhang D

    更新日期:2012-09-01 00:00:00

  • A finite volume method for modeling discontinuous electrical activation in cardiac tissue.

    abstract::This paper describes a finite volume method for modeling electrical activation in a sample of cardiac tissue using the bidomain equations. Microstructural features to the level of cleavage planes between sheets of myocardial fibers in the tissue are explicitly represented. The key features of this implementation compa...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-005-1434-6

    authors: Trew M,Le Grice I,Smaill B,Pullan A

    更新日期:2005-05-01 00:00:00

  • Linear homeomorphic models for muscles in the head-neck region.

    abstract::The linear homeomorphic muscle model proposed by Enderle and coworkers for the rectus eye muscle is fitted to reflect the dynamics of muscles in the head-neck complex, specifically in muscles involved in gaze shifts. This parameterization of the model for different muscles in the neck region will serve to drive a 3D d...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-009-9851-6

    authors: Sierra DA,Enderle JD

    更新日期:2010-02-01 00:00:00

  • A new bioreactor for the development of tissue-engineered heart valves.

    abstract::This paper reports the design, manufacturing, and characterization of a new bioreactor dedicated to the development of tissue-engineered heart valve substitutes. First, a comprehensive review of the state of the art in bioreactors is presented and a rigorous classification is put forward. The existing bioreactors foun...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-009-9646-9

    authors: Ruel J,Lachance G

    更新日期:2009-04-01 00:00:00

  • Soft 3D-Printed Phantom of the Human Kidney with Collecting System.

    abstract::Organ models are used for planning and simulation of operations, developing new surgical instruments, and training purposes. There is a substantial demand for in vitro organ phantoms, especially in urological surgery. Animal models and existing simulator systems poorly mimic the detailed morphology and the physical pr...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-016-1757-5

    authors: Adams F,Qiu T,Mark A,Fritz B,Kramer L,Schlager D,Wetterauer U,Miernik A,Fischer P

    更新日期:2017-04-01 00:00:00

  • Tauberian-prony feature extraction technique for esophageal motility patterns.

    abstract::For the esophageal contractile activity recorded during swallowing, a feature extraction scheme has been developed. It recognizes the time, duration, and amplitudes of local peaks for each peristaltic wave. The method is based on the Tauberian approximation for modeling waveforms as a sum of identically shaped pulses ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02367607

    authors: Abou-Chadi FE,Ezzat FA,Gad-Elhak N,Sif el-Din AA

    更新日期:1993-03-01 00:00:00

  • Vortex ring formation in the left ventricle of the heart: analysis by 4D flow MRI and Lagrangian coherent structures.

    abstract::Recent studies suggest that vortex ring formation during left ventricular (LV) rapid filling is an optimized mechanism for blood transport, and that the volume of the vortex ring is an important measure. However, due to lack of quantitative methods, the volume of the vortex ring has not previously been studied. Lagran...

    journal_title:Annals of biomedical engineering

    pub_type: 临床试验,杂志文章

    doi:10.1007/s10439-012-0615-3

    authors: Töger J,Kanski M,Carlsson M,Kovács SJ,Söderlind G,Arheden H,Heiberg E

    更新日期:2012-12-01 00:00:00

  • A computerized mass spectrometer and flowmeter system for respiratory gas measurements.

    abstract::Instrumentation systems for breath-to-breath analysis of respiratory gas exchange have been faulted by phase lags between various flow and composition signals and by difficulties in gathering and processing large amounts of data. The system described here represents an attempt to overcome these problems. Phase delays ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02367493

    authors: Sodal IE,Swanson GD,Micco AJ,Sprague F,Ellis DG

    更新日期:1983-01-01 00:00:00

  • Self-contained in-the-ear device to deliver altered auditory feedback: applications for stuttering.

    abstract::The design and operating characteristics of the first self-contained in-the-ear device to deliver altered auditory feedback is described for applications with those who stutter. The device incorporates a microdigital signal processor core that reproduces the high fidelity of unaided listening and auditory self-monitor...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1541014

    authors: Stuart A,Xia S,Jiang Y,Jiang T,Kalinowski J,Rastatter MP

    更新日期:2003-02-01 00:00:00

  • A physical model describing the mechanism for formation of gas microbubbles in patients with mitral mechanical heart valves.

    abstract::This study was aimed at developing a physical model, supported by experimental observations, to describe the formation and growth of microbubbles seen in patients with mitral mechanical heart valves (MHV). This phenomenon, often referred to as high intensity transient signals (HITS), appears as bright, intense, high-v...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.231

    authors: Rambod E,Beizaie M,Shusser M,Milo S,Gharib M

    更新日期:1999-11-01 00:00:00

  • Partial Bone Formation in Additive Manufactured Porous Implants Reduces Predicted Stress and Danger of Fatigue Failure.

    abstract::New porous implant designs made possible by additive manufacturing allow for increased osseointegration, potentially improving implant performance and longevity for patients that require massive bone implants. The aim of this study was to evaluate how implantation and the strain distribution in the implant affect the ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-019-02369-z

    authors: Cheong VS,Fromme P,Coathup MJ,Mumith A,Blunn GW

    更新日期:2020-01-01 00:00:00

  • Quadratic phase coupling as a quantitative measure for the developing hippocampal formation.

    abstract::This paper presents the bispectral analysis of the ontogeny of the hippocampal EEG recorded from the dentate gyrus and CA1, the primary sites that generate theta (theta) rhythm. The hippocampal EEG was collected during the vigilance state of rapid eye movement (REM) sleep of freely moving rats at 15, 30 and 90 days of...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.43

    authors: Ning T,Bronzino JD

    更新日期:1998-07-01 00:00:00

  • Blood pressure measurement in noise intensive environments using adaptive interference cancellation.

    abstract::The traditional auscultatory technique and current methodologies for measuring human blood pressure are limited when used in situations where extreme vibration or acoustic noise is present. In this study, human subjects were used to establish the effectiveness of a novel adaptive blood pressure monitoring (ABPM) syste...

    journal_title:Annals of biomedical engineering

    pub_type: 临床试验,杂志文章

    doi:10.1114/1.1481051

    authors: Pinto L,Dhanantwari A,Wong W,Stergiopoulos S,Maris M

    更新日期:2002-05-01 00:00:00

  • Left ventricular external constraint: relationship between pericardial, pleural and esophageal pressures during positive end-expiratory pressure and volume loading in dogs.

    abstract::Left ventricular (LV) diastolic filling is limited by the constraining effects exerted by the pericardium (PE) and the lung/chest wall. The aim of the present study was to assess the validity of various estimates of external cardiac constraint, compared to pericardial surface pressure (Ppe) measured lateral to the LV ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02584288

    authors: Kingma I,Smiseth OA,Frais MA,Smith ER,Tyberg JV

    更新日期:1987-01-01 00:00:00

  • A preliminary physiologically based pharmacokinetic model for naphthalene and naphthalene oxide in mice and rats.

    abstract::Naphthalene is a toxicant with unusual species and tissue specificity that has been the subject of in vitro studies. We describe a preliminary physiologically based pharmacokinetic (PBPK) model for naphthalene constructed solely from in vitro data for comparison to animal data without the use of adjustable parameters....

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02667357

    authors: Sweeney LM,Shuler ML,Quick DJ,Babish JG

    更新日期:1996-03-01 00:00:00

  • Electrical impedance cardiography using artificial neural networks.

    abstract::This study evaluates the use of artificial neural networks to estimate stroke volume from pre-processed, thoracic impedance plethysmograph signals from 20 healthy subjects. Standard back-propagation was used to train the networks, with Doppler stroke volume estimates as the desired output. The trained networks were th...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.47

    authors: Mulavara AP,Timmons WD,Nair MS,Gupta V,Kumar AA,Taylor BC

    更新日期:1998-07-01 00:00:00

  • Modulation of rod photoreceptor potassium Kx current by divalent cations.

    abstract::Similarities between photoreceptor Kx channels and EAG and KCNQ channels suggest that the Kx channel may be related to one or both of these families of potassium channels. To provide a basis for further comparison of these channels, as well as to reveal the role of zinc (endogenously present in photoreceptors) in Kx c...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1521415

    authors: Kourennyi DE,Liu X,Barnes S

    更新日期:2002-01-01 00:00:00

  • The Microcirculation Physiome Project.

    abstract::Presented is a discussion of steps towards the creation of a database of the microcirculation encompassing anatomical and functional experimental data, and conceptual and computational models. The discussion includes issues of database utility, organization, data deposition, and linkage to other databases. The databas...

    journal_title:Annals of biomedical engineering

    pub_type:

    doi:10.1114/1.112

    authors: Popel AS,Greene AS,Ellis CG,Ley KF,Skalak TC,Tonellato PJ

    更新日期:1998-11-01 00:00:00

  • Coupling of a 3D finite element model of cardiac ventricular mechanics to lumped systems models of the systemic and pulmonic circulation.

    abstract::In this study we present a novel, robust method to couple finite element (FE) models of cardiac mechanics to systems models of the circulation (CIRC), independent of cardiac phase. For each time step through a cardiac cycle, left and right ventricular pressures were calculated using ventricular compliances from the FE...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-006-9212-7

    authors: Kerckhoffs RC,Neal ML,Gu Q,Bassingthwaighte JB,Omens JH,McCulloch AD

    更新日期:2007-01-01 00:00:00

  • Simultaneous Measurement of Contraction and Calcium Transients in Stem Cell Derived Cardiomyocytes.

    abstract::Induced pluripotent stem cell derived cardiomyocytes (iPSC-CM) provide a powerful platform for disease modeling and drug development in vitro. Traditionally, electrophysiological methods or fluorescent dyes (e.g. calcium) have been used in their functional characterization. Recently, video microscopy has enabled non-i...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-017-1933-2

    authors: Ahola A,Pölönen RP,Aalto-Setälä K,Hyttinen J

    更新日期:2018-01-01 00:00:00

  • Electrically active bioceramics: a review of interfacial responses.

    abstract::Electrical potentials in mechanically loaded bone have been implicated as signals in the bone remodeling cycle. Recently, interest has grown in exploiting this phenomenon to develop electrically active ceramics for implantation in hard tissue which may induce improved biological responses. Both polarized hydroxyapatit...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/s10439-010-9977-6

    authors: Baxter FR,Bowen CR,Turner IG,Dent AC

    更新日期:2010-06-01 00:00:00

  • Shear modulus of elasticity of the esophagus.

    abstract::Experimental and diagnostic procedures like distension of a balloon catheter, bougie, and esophagogastroduodenoscopy can induce shear deformation in the esophageal wall. However, the shear modulus of the esophagus is yet unknown. The aim of this study was to determine the esophageal shear modulus and its dependence on...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/b:abme.0000039356.24821.6c

    authors: Yang J,Liao D,Zhao J,Gregersen H

    更新日期:2004-09-01 00:00:00

  • Measurement of three-dimensional anisotropic diffusion by multiphoton fluorescence recovery after photobleaching.

    abstract::The multiphoton fluorescence recovery after photobleaching (MP-FRAP) technique has been developed to measure the three-dimensional (3D) solute diffusion within biological systems. However, current 3D MP-FRAP models are based on isotropic diffusion and spatial domain analysis. The 3D anisotropic diffusion and frequency...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-013-0939-7

    authors: Shi C,Cisewski SE,Bell PD,Yao H

    更新日期:2014-03-01 00:00:00

  • Modeling the instantaneous pressure-volume relation of the left ventricle: a comparison of six models.

    abstract::Simulations are useful to study the heart's ability to generate flow and the interaction between contractility and loading conditions. The left ventricular pressure-volume (PV) relation has been shown to be nonlinear, but it is unknown whether a linear model is accurate enough for simulations. Six models were fitted t...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-009-9742-x

    authors: Lankhaar JW,Rövekamp FA,Steendijk P,Faes TJ,Westerhof BE,Kind T,Vonk-Noordegraaf A,Westerhof N

    更新日期:2009-09-01 00:00:00