Fluid flow-induced calcium response in early or late differentiated osteoclasts.

Abstract:

:Intracellular calcium oscillation caused by receptor activator of nuclear factor kappa-B ligand has been demonstrated to promote the differentiation of osteoclasts. Osteoclasts are recruited on the surface of trabeculae, and are exposed to fluid flow caused by the deformation of the bone matrix. However, the roles of fluid shear stress (FSS) on calcium response during the differentiation process of osteoclasts are still unknown. In the current study, the formation of tartrate-resistant acid phosphatase-positive, multinucleated osteoclasts from RAW264.7 macrophage cells were induced by co-culturing them with the conditioned medium from MC3T3-E1 osteoblasts. The in situ observations showed a high correlation between the area and the nuclear number of osteoclasts. The cells were stimulated by FSS at different levels (1 or 10 dyne/cm(2)) before (0 day) or after being induced for 4 or 8 days. The mechanically-induced calcium response was recorded and analyzed. The results indicated a different property of calcium oscillation for the osteoclasts in different fusion stages (i.e., more calcium-responsive peaks appeared in small osteoclasts than those in the larger ones). The rates of calcium influx decreased and the time of recovery in osteoclast cytosol increased along with the fusion of osteoclasts. In addition, increasing the FSS level enhanced the calcium oscillation of osteoclasts at early induction (4 days). However, this effect was weakened at the late induction (8 days). The present work could help provide understanding regarding the mechanism of the involvement of calcium in mechanically induced bone remodeling.

journal_name

Ann Biomed Eng

authors

Li P,Hu M,Sun S,Zhang Y,Gao Y,Long M,Huo B,Zhang D

doi

10.1007/s10439-012-0554-z

subject

Has Abstract

pub_date

2012-09-01 00:00:00

pages

1874-83

issue

9

eissn

0090-6964

issn

1573-9686

journal_volume

40

pub_type

杂志文章
  • Permeability analysis of neuroactive drugs through a dynamic microfluidic in vitro blood-brain barrier model.

    abstract::This paper presents the permeability analysis of neuroactive drugs and correlation with in vivo brain/plasma ratios in a dynamic microfluidic blood-brain barrier (BBB) model. Permeability of seven neuroactive drugs (Ethosuximide, Gabapentin, Sertraline, Sunitinib, Traxoprodil, Varenicline, PF-304014) and trans-endothe...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-014-1086-5

    authors: Booth R,Kim H

    更新日期:2014-12-01 00:00:00

  • Prediction of Post-Concussive Behavioral Changes in a Rodent Model Based on Head Rotational Acceleration Characteristics.

    abstract::Quantifying injury tolerance for concussion is complicated by variability in the type, severity, and time course of post-injury physiological and behavioral changes. The current study outlined acute and chronic changes in behavioral metrics following rotational acceleration-induced concussion in rats. The Medical Coll...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-016-1647-x

    authors: Stemper BD,Shah AS,Chiariello R,Olsen CM,Budde MD,Glavaski-Joksimovic A,McCrea M,Kurpad SN,Pintar FA

    更新日期:2016-11-01 00:00:00

  • Analytical Modelling of Natural Frequency of Tympanic Membrane as the Low-Frequency Limit of Hearing.

    abstract::We examine the low-frequency limit of hearing of the mammalian ear through the analytical modelling of the natural frequency of the tympanic membrane. The resulting equation of the natural frequency of the modelled tympanic membrane is numerically verified against previous theoretical studies, and is statistically val...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-019-02356-4

    authors: Jabaraj DJ

    更新日期:2020-01-01 00:00:00

  • Do increased electrogastrographic frequencies always correspond to internal tachygastria?

    abstract::This study was undertaken to investigate the possible origin of some cutaneously recorded higher frequency electrogastrographic signals. Computer modeling of gastric electrical uncoupling was performed using previously described conoidal dipole model. Cutaneous electrogastrograms were simulated after uncoupling was in...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:

    authors: Mintchev MP,Bowes KL

    更新日期:1997-11-01 00:00:00

  • Flow visualization in mechanical heart valves: occluder rebound and cavitation potential.

    abstract::High density particle image velocimetry, with spatial resolution of O(1 mm), was used to measure the effect of occluder rebound on the flow field near a Bjork-Shiley Monostrut tilting-disk mitral valve. The ability to measure two velocity components over an entire plane simultaneously provides a very different insight...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.281

    authors: Kini V,Bachmann C,Fontaine A,Deutsch S,Tarbell JM

    更新日期:2000-04-01 00:00:00

  • Computational study of proteolysis-driven single cell migration in a three-dimensional matrix.

    abstract::Cell migration is a fundamental process that is crucial to a variety of physiological events. While traditional approaches have focused on two-dimensional (2D) systems, recent efforts have shifted to studying migration in three-dimensional (3D) matrices. A major distinction that has emerged is the increased importance...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-9970-0

    authors: Harjanto D,Zaman MH

    更新日期:2010-05-01 00:00:00

  • The Impact of Fluid Inertia on In Vivo Estimation of Mitral Valve Leaflet Constitutive Properties and Mechanics.

    abstract::We examine the influence of the added mass effect (fluid inertia) on mitral valve leaflet stress during isovolumetric phases. To study this effect, oscillating flow is applied to a flexible membrane at various frequencies to control inertia. Resulting membrane strain is calculated through a three-dimensional reconstru...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1463-8

    authors: Bark DL Jr,Dasi LP

    更新日期:2016-05-01 00:00:00

  • Zonal uniformity in mechanical properties of the chondrocyte pericellular matrix: micropipette aspiration of canine chondrons isolated by cartilage homogenization.

    abstract::The pericellular matrix (PCM) is a region of tissue that surrounds chondrocytes in articular cartilage and together with the enclosed cells is termed the chondron. Previous studies suggest that the mechanical properties of the PCM, relative to those of the chondrocyte and the extracellular matrix (ECM), may significan...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-005-4479-7

    authors: Guilak F,Alexopoulos LG,Haider MA,Ting-Beall HP,Setton LA

    更新日期:2005-10-01 00:00:00

  • Nanoparticle-Mediated TGF-β Release from Microribbon-Based Hydrogels Accelerates Stem Cell-Based Cartilage Formation In Vivo.

    abstract::Conventional nanoporous hydrogels often lead to slow cartilage deposition by MSCs in 3D due to physical constraints and requirement for degradation. Our group has recently reported macroporous gelatin microribbon (μRB) hydrogels, which substantially accelerate MSC-based cartilage formation in vitro compared to convent...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02522-z

    authors: Barati D,Gegg C,Yang F

    更新日期:2020-07-01 00:00:00

  • Generalized sensitivity functions in physiological system identification.

    abstract::Parameters of physiological models are commonly associated in an input-output experiment with a specific pattern of the system response. This association is often made on an intuitive basis by traditional sensitivity analysis, i.e., by inspecting the variations of model output trajectories with respect to parameter va...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.207

    authors: Thomaseth K,Cobelli C

    更新日期:1999-09-01 00:00:00

  • A new pulsatile flow visualization method using a photochromic dye with application to Doppler ultrasound.

    abstract::A nonintrusive method for the visualization of pulsatile flow velocity profiles is described. The method is based on the use of a photochromic dye that is added to the fluid being studied and a nitrogen laser which excites the dye producing a marker "line" whose movement can be photographed. A microcomputer is used as...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02584271

    authors: Poots K,Cobbold RS,Johnston KW,Appugliese R,Kassam M,Zuech PE,Hummel RL

    更新日期:1986-01-01 00:00:00

  • Signaling in the motility responses of the human neutrophil.

    abstract::The neutrophil has developed into one of the most efficient vertebrate motile cells. It migrates through tissues, where it encounters multiple chemoattractant signals with complex spatial and temporal characteristics. The directional movement of the neutrophil is signaled by the binding of chemoattractants and chemoki...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1114/1.1477446

    authors: Zhelev DV,Alteraifi A

    更新日期:2002-03-01 00:00:00

  • Osteoarthritis: Pathology, Mouse Models, and Nanoparticle Injectable Systems for Targeted Treatment.

    abstract::Osteoarthritis (OA) is a progressive, degenerative disease of articulating joints that not only affects the elderly, but also involves younger, more active individuals with prolonged participation in high physical-demand activities. Thus, effective therapies that are easy to adopt clinically are critical in limiting t...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/s10439-016-1600-z

    authors: Holyoak DT,Tian YF,van der Meulen MC,Singh A

    更新日期:2016-06-01 00:00:00

  • Left ventricular external constraint: relationship between pericardial, pleural and esophageal pressures during positive end-expiratory pressure and volume loading in dogs.

    abstract::Left ventricular (LV) diastolic filling is limited by the constraining effects exerted by the pericardium (PE) and the lung/chest wall. The aim of the present study was to assess the validity of various estimates of external cardiac constraint, compared to pericardial surface pressure (Ppe) measured lateral to the LV ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02584288

    authors: Kingma I,Smiseth OA,Frais MA,Smith ER,Tyberg JV

    更新日期:1987-01-01 00:00:00

  • Hierarchical CT to Ultrasound Registration of the Lumbar Spine: A Comparison with Other Registration Methods.

    abstract::Three-dimensional (3D) measurement of the spine can provide important information for functional, developmental, diagnostic, and treatment-effect evaluations. However, existing measurement techniques are either 2-dimensional, highly invasive, or involve a high radiation dose, prohibiting their widespread and repeated ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-016-1599-1

    authors: Koo TK,Kwok WE

    更新日期:2016-10-01 00:00:00

  • A device for imposing cyclic strain to cells growing on implant alloys.

    abstract::The objective of this study was to develop a unique device for applying well-characterized cyclic, strain to cells growing on implant alloys. The device is based on the four-point bending principle and utilizes an electric motor, belt, and cam system to cyclically deflect a commercially pure titanium plate with cell c...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1529195

    authors: Winter LC,Gilbert JA,Elder SH,Bumgardner JD

    更新日期:2002-11-01 00:00:00

  • Body-worn sensor design: what do patients and clinicians want?

    abstract::User preferences need to be taken into account in order to be able to design devices that will gain acceptance both in a clinical and home setting. Sensor systems become redundant if patients or clinicians do not want to work with them. The aim of this systematic review was to determine both patients' and clinicians' ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/s10439-011-0339-9

    authors: Bergmann JH,McGregor AH

    更新日期:2011-09-01 00:00:00

  • Effects of Chemically Doped Bioactive Borate Glass on Neuron Regrowth and Regeneration.

    abstract::Peripheral nerve injuries present challenges to regeneration. Currently, the gold standard for nerve repair is an autograft that results in another region of the body suffering nerve damage. Previously, bioactive borate glass (BBG) has been studied in clinical trials to treat patients with non-healing wounds, and we h...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-016-1689-0

    authors: Gupta B,Papke JB,Mohammadkhah A,Day DE,Harkins AB

    更新日期:2016-12-01 00:00:00

  • Multifunctional FePt nanoparticles for radiation-guided targeting and imaging of cancer.

    abstract::A multifunctional FePt nanoparticle was developed that targets tumor microvasculature via "radiation-guided" peptides, and is detected by both near-infrared (NIR) fluorescence imaging and analytical mass spectrometry methods. Tumor specific binding was first measured by biotinylated peptide linked to fluorophore-conju...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-0219-8

    authors: Hariri G,Wellons MS,Morris WH 3rd,Lukehart CM,Hallahan DE

    更新日期:2011-03-01 00:00:00

  • Real-Time linux dynamic clamp: a fast and flexible way to construct virtual ion channels in living cells.

    abstract::We describe a system for real-time control of biological and other experiments. This device, based around the Real-Time Linux operating system, was tested specifically in the context of dynamic clamping, a demanding real-time task in which a computational system mimics the effects of nonlinear membrane conductances in...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1408929

    authors: Dorval AD,Christini DJ,White JA

    更新日期:2001-10-01 00:00:00

  • Optical Metabolic Imaging for Assessment of Radiation-Induced Injury to Rat Kidney and Mitigation by Lisinopril.

    abstract::The kidney is one of the most radiosensitive organs; it is the primary dose-limiting organ in radiotherapies for upper abdominal cancers. The role of mitochondrial redox state in the development and treatment of renal radiation injury, however, remains ill-defined. This study utilizes 3D optical cryo-imaging to quanti...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-019-02255-8

    authors: Mehrvar S,la Cour MF,Medhora M,Camara AKS,Ranji M

    更新日期:2019-07-01 00:00:00

  • Mechanical Performance of Two Left Atrial Appendage Occlusion Systems: In Vitro Comparison of Tug Force, Radial Force, Sealing and Deformation.

    abstract::The aim of this study was to establish in vitro bench-tests of left atrial appendage occlusion (LAAo) devices regarding tug force, radial force and sealing capacity. Two LAAo devices, namely the WATCHMAN™ and the Occlutech®, of three different sizes underwent testing in novel dedicated in vitro setups. Radial force wa...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-018-2057-z

    authors: Menne MF,Schrickel JW,Nickenig G,Al-Kassou B,Nelles D,Schmitz-Rode T,Steinseifer U,Sedaghat A

    更新日期:2018-09-01 00:00:00

  • The impedance of a spherical monopolar electrode.

    abstract::The impedance of a monopolar electrode immersed in an environmental volume conductor consists of two parts; the impedance of the active electrode-electrolyte interface, and the resistance of the environmental conductor. Two studies were carried out to quantitate these components. First, impedance-frequency data were c...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02368609

    authors: Ragheb T,Riegle S,Geddes LA,Amin V

    更新日期:1992-01-01 00:00:00

  • Effect of extracellular potassium accumulation on muscle fiber conduction velocity: a simulation study.

    abstract::A progressive reduction in muscle fiber conduction velocity is typically observed during fatiguing muscle contraction. Although the exact causes of the conduction velocity decrease have not yet been fully established, increasing evidence suggests that changes in extracellular potassium concentration may be largely res...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-009-9756-4

    authors: Fortune E,Lowery MM

    更新日期:2009-10-01 00:00:00

  • Pixel-Based DXA-Derived Structural Properties Strongly Correlate with pQCT Measures at the One-Third Distal Femur Site.

    abstract::While bone mineral density has been traditionally used to quantify fracture risk for individuals with spinal cord injuries, recent studies are including engineering measurements such as section modulus and cross sectional moment of inertia. These are almost exclusively calculated by peripheral QCT scanners which, unli...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-017-1796-6

    authors: Baker AM,Wagner DW,Kiratli BJ,Beaupre GS

    更新日期:2017-05-01 00:00:00

  • Characterizing the variability of system kernel and input estimates.

    abstract::The identification of the input to, or kernels of, a system using nonparametric representations and least-squares estimation is becoming increasingly popular. Nonparametric representations avoid making a priori assumptions about the input or having detailed knowledge about the system, and only need to guarantee known ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.110

    authors: Verotta D

    更新日期:1998-09-01 00:00:00

  • A novel left heart simulator for the multi-modality characterization of native mitral valve geometry and fluid mechanics.

    abstract::Numerical models of the mitral valve have been used to elucidate mitral valve function and mechanics. These models have evolved from simple two-dimensional approximations to complex three-dimensional fully coupled fluid structure interaction models. However, to date these models lack direct one-to-one experimental val...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-012-0651-z

    authors: Rabbah JP,Saikrishnan N,Yoganathan AP

    更新日期:2013-02-01 00:00:00

  • Compressive deformation and damage of muscle cell subpopulations in a model system.

    abstract::To study the effects of compressive straining on muscle cell deformation and damage an in vitro model system was developed. Myoblasts were seeded in agarose constructs and cultured in growth medium for 4 days. Subsequently, the cells were allowed to fuse into multinucleated myotubes for 8 days in differentiation mediu...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1349698

    authors: Bouten CV,Knight MM,Lee DA,Bade DL

    更新日期:2001-02-01 00:00:00

  • Off-line and on-line stress detection through processing of the pupil diameter signal.

    abstract::The pupil diameter (PD), controlled by the autonomic nervous system, seems to provide a strong indication of affective arousal, as found by previous research, but it has not been investigated fully yet. In this study, new approaches based on monitoring and processing the PD signal for off-line and on-line "relaxation"...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-013-0880-9

    authors: Ren P,Barreto A,Huang J,Gao Y,Ortega FR,Adjouadi M

    更新日期:2014-01-01 00:00:00

  • Countercurrent extraction of sparingly soluble gases for membrane introduction mass spectrometry.

    abstract::Membrane introduction mass spectrometry has been applied to inert gas measurements in blood and tissue, but gases with low blood solubility are associated with reduced sensitivity. Countercurrent extraction of inert gases from a blood sample into a water carrier phase has the potential to extract most of the gas sampl...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02684170

    authors: Baumgardner JE,Neufeld GR

    更新日期:1997-09-01 00:00:00