A new pulsatile flow visualization method using a photochromic dye with application to Doppler ultrasound.

Abstract:

:A nonintrusive method for the visualization of pulsatile flow velocity profiles is described. The method is based on the use of a photochromic dye that is added to the fluid being studied and a nitrogen laser which excites the dye producing a marker "line" whose movement can be photographed. A microcomputer is used as a system controller, to coordinate the system timing and to manage the data transfer. The method used for analysis of the photographs to determine the velocity profiles is described. Examples are presented of instantaneous velocity profiles obtained from velocity waveforms that are similar to those of the femoral artery. In addition, application of the system for studying the relationship between Doppler ultrasound spectral recordings and flow velocity profiles is discussed.

journal_name

Ann Biomed Eng

authors

Poots K,Cobbold RS,Johnston KW,Appugliese R,Kassam M,Zuech PE,Hummel RL

doi

10.1007/BF02584271

subject

Has Abstract

pub_date

1986-01-01 00:00:00

pages

203-18

issue

3

eissn

0090-6964

issn

1573-9686

journal_volume

14

pub_type

杂志文章
  • A novel approach to track fetal movement using multi-sensor magnetocardiographic recordings.

    abstract::Changes in fetal magnetocardiographic (fMCG) signals are indicators for fetal body movement. We propose a novel approach to reliably extract fetal body movements based on the field strength of the fMCG signal independent of its frequency. After attenuating the maternal MCG, we use a Hilbert transform approach to ident...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-0231-z

    authors: Govindan RB,Vairavan S,Ulusar UD,Wilson JD,McKelvey SS,Preissl H,Eswaran H

    更新日期:2011-03-01 00:00:00

  • LDL decreases the membrane compliance and cell adhesion of endothelial cells under fluid shear stress.

    abstract::Atherosclerosis is an inflammatory disease of large and medium sized arteriole walls that is precipitated by elevated levels of low-density lipoprotein (LDL) cholesterol in the blood. However, the mechanisms that lead to the initiation of atherosclerosis are not fully understood. In this study, endothelial cells (ECs)...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-012-0677-2

    authors: Wei D,Chen Y,Tang C,Huang H,Liu L,Wang Z,Li R,Wang G

    更新日期:2013-03-01 00:00:00

  • Experimental investigation of steady flow in rigid models of abdominal aortic aneurysms.

    abstract::Abdominal aortic aneurysms occur in as much as 2-3% of the population, and their rupture produces a mortality rate of 78-94% (1), causing 15,000 deaths per year in the U.S. alone. As an investigation into the mechanical factors that lead to aneurysm rupture, flow field measurements are presented for steady flow throug...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02368298

    authors: Asbury CL,Ruberti JW,Bluth EI,Peattie RA

    更新日期:1995-01-01 00:00:00

  • Degradation, bioactivity, and osteogenic potential of composites made of PLGA and two different sol-gel bioactive glasses.

    abstract::We have developed poly(L: -lactide-co-glycolide) (PLGA) based composites using sol-gel derived bioactive glasses (S-BG), previously described by our group, as composite components. Two different composite types were manufactured that contained either S2-high content silica S-BG, or A2-high content lime S-BG. The compo...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-011-0307-4

    authors: Pamula E,Kokoszka J,Cholewa-Kowalska K,Laczka M,Kantor L,Niedzwiedzki L,Reilly GC,Filipowska J,Madej W,Kolodziejczyk M,Tylko G,Osyczka AM

    更新日期:2011-08-01 00:00:00

  • Bioengineering the skin-implant interface: the use of regenerative therapies in implanted devices.

    abstract::This discussion and review article focuses on the possible use of regenerative techniques applied to the interfaces between skin and medical implants. As is widely known, the area of contact between an implant and the skin--the skin-implant interface--is prone to recurrent and persistent problems originated from the l...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/s10439-010-9937-1

    authors: Peramo A,Marcelo CL

    更新日期:2010-06-01 00:00:00

  • Delayed activation and retrograde propagation in cardiac muscle: implication of virtual electrode effects.

    abstract::Point cathodal stimulation of cardiac tissue was shown previously to produce both a dog-bone shaped virtual cathode transverse to the muscle fibers and two longitudinal virtual anodes. We hypothesize that virtual anodes can cause a region of delayed activation, separating two regions of early activation caused by the ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1326029

    authors: Wu J,Roden DM,Wikswo JP Jr

    更新日期:2000-11-01 00:00:00

  • Parameter estimation for linear compartmental models--a sensitivity analysis approach.

    abstract::Linear compartmental models are useful, explanatory tools, that have been widely used to represent the dynamic behavior of complex biological systems. This paper addresses the problem of the numerical identification of such models, i.e., the estimation of the parameter values that will generate predictions closest to ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-009-9651-z

    authors: Juillet B,Bos C,Gaudichon C,Tomé D,Fouillet H

    更新日期:2009-05-01 00:00:00

  • BMP-2 gene modified canine bMSCs promote ectopic bone formation mediated by a nonviral PEI derivative.

    abstract::The study was to explore the effects of BMP-2 gene modified canine bone marrow stromal cells (bMSCs) mediated by a nonviral PEI derivative (GenEscort™ II) in promoting bone formation in vitro and in vivo. Canine bMSCs were cultured and transfected with plasmids containing bone morphogenetic protein-2 gene (pBMP-2) or ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-011-0276-7

    authors: Lü K,Zeng D,Zhang Y,Xia L,Xu L,Kaplan DL,Jiang X,Zhang F

    更新日期:2011-06-01 00:00:00

  • A microcomputer oxygen control system for ventilatory therapy.

    abstract::A computer-based feedback system has been developed to adjust the concentration of oxygen in the inspired gas of a patient under artificial respiration. The system uses a proportional plus integral controller and feedback of arterial oxygen saturation to adjust the inspired oxygen fraction. The effectiveness of the co...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02368173

    authors: Tehrani FT

    更新日期:1992-01-01 00:00:00

  • Through the microcirculatory maze with machete, molecule, and minicomputer (1986 Alza lecture).

    abstract::This is a personal historical essay on meanderings through the jungle of the microcirculatory swamp. Because one pretends that the wandering was purposefully exploratory, a few guideposts are placed at positions where one could discern blaze-marks from earlier wanderers, and the path cut a little wider along some of t...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/BF02363568

    authors: Bassingthwaighte JB

    更新日期:1987-01-01 00:00:00

  • Investigating the influence of haemodynamic stimuli on intracranial aneurysm inception.

    abstract::We propose a novel method to reconstruct the hypothetical geometry of the healthy vasculature prior to intracranial aneurysm (IA) formation: a Frenet frame is calculated along the skeletonization of the arterial geometry; upstream and downstream boundaries of the aneurysmal segment are expressed in terms of the local ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-013-0794-6

    authors: Chen H,Selimovic A,Thompson H,Chiarini A,Penrose J,Ventikos Y,Watton PN

    更新日期:2013-07-01 00:00:00

  • A Novel Approach to Utilize Icariin as Icariin-Derived ECM on Small Intestinal Submucosa Scaffold for Bone Repair.

    abstract::Icariin (Ic) has been demonstrated as a potent osteoinductive compound for bone tissue engineering. However, toxic side effects of the drug and poor biocompatibility of drug delivery systems (DDSs) still limit its application for bone repair in the clinic. To overcome these disadvantages and utilize the osteoinductivi...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-017-1900-y

    authors: Li M,Zhang C,Zhong Y,Zhao J

    更新日期:2017-11-01 00:00:00

  • Magnetic (eddy-current) electroventilation in the dog.

    abstract::Magnetic (eddy-current) stimulation of the inspiratory motor nerves in the neck of the anesthetized dog was achieved. Using a 10-turn coil wound around the base of the neck and a train of pulses (25/s), inspiration was produced by tetanic contraction of the inspiratory muscles. The volume of air inspired increased wit...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02368176

    authors: Geddes LA,Mouchawar G,Bourland JD,ElAbbady T,Nyenhuis J

    更新日期:1993-05-01 00:00:00

  • Measurement of in vivo stress resultants in neurulation-stage amphibian embryos.

    abstract::In order to obtain the first quantitative measurements of the in vivo stresses in early-stage amphibian embryos, we developed a novel instrument that uses a pair of parallel wires that are glued to the surface of an embryo normal to the direction in which the stress is to be determined. When a slit is made parallel to...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-006-9250-1

    authors: Benko R,Brodland GW

    更新日期:2007-04-01 00:00:00

  • Retinal vascular permeability determined by dual-tracer fluorescence angiography.

    abstract::Diabetic retinopathy is the leading cause of blindness in working age individuals in the United States. Breakdown of the blood-retinal barrier is one of the earliest events in the progression of diabetic retinopathy. Ideally, therapeutic measures would be directed at this early stage, but there are few sensitive, quan...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1385809

    authors: Russ PK,Gaylord GM,Haselton FR

    更新日期:2001-08-01 00:00:00

  • Investigation of the Sequential Actions of Doxorubicin and p53 on Tumor Cell Growth Via Branched Polyethylenimine-β-cyclodextrin Conjugates.

    abstract::The combination of gene therapy and chemotherapy has showed increased therapeutic efficacy in the treatment of cancers, but it is not well investigated about the actual coordination pattern between therapeutic gene and chemical drug. In this work, p53/BPEI-β-CD/AD-dox complex was fabricated and employed to investigate...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-016-1627-1

    authors: Xie B,Peng J,Wang S,Zhang X,Nie H

    更新日期:2016-11-01 00:00:00

  • Impact of Pulmonary Venous Inflow on Cardiac Flow Simulations: Comparison with In Vivo 4D Flow MRI.

    abstract::Blood flow simulations are making their way into the clinic, and much attention is given to estimation of fractional flow reserve in coronary arteries. Intracardiac blood flow simulations also show promising results, and here the flow field is expected to depend on the pulmonary venous (PV) flow rates. In the absence ...

    journal_title:Annals of biomedical engineering

    pub_type: 临床试验,杂志文章

    doi:10.1007/s10439-018-02153-5

    authors: Lantz J,Gupta V,Henriksson L,Karlsson M,Persson A,Carlhäll CJ,Ebbers T

    更新日期:2019-02-01 00:00:00

  • Effects of hydration and fixed charge density on fluid transport in charged hydrated soft tissues.

    abstract::The effects of tissue hydration and fixed charge density on hydraulic permeability and creep behavior of cartilaginous tissues have been investigated using the triphasic theory and finite element methods. The empirical model for hydraulic permeability of uncharged gels and Mackie and Meares (1955) model for ion diffus...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1615576

    authors: Gu WY,Yao H

    更新日期:2003-11-01 00:00:00

  • Effect of extracellular potassium accumulation on muscle fiber conduction velocity: a simulation study.

    abstract::A progressive reduction in muscle fiber conduction velocity is typically observed during fatiguing muscle contraction. Although the exact causes of the conduction velocity decrease have not yet been fully established, increasing evidence suggests that changes in extracellular potassium concentration may be largely res...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-009-9756-4

    authors: Fortune E,Lowery MM

    更新日期:2009-10-01 00:00:00

  • Body-worn sensor design: what do patients and clinicians want?

    abstract::User preferences need to be taken into account in order to be able to design devices that will gain acceptance both in a clinical and home setting. Sensor systems become redundant if patients or clinicians do not want to work with them. The aim of this systematic review was to determine both patients' and clinicians' ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/s10439-011-0339-9

    authors: Bergmann JH,McGregor AH

    更新日期:2011-09-01 00:00:00

  • Vortex ring formation in the left ventricle of the heart: analysis by 4D flow MRI and Lagrangian coherent structures.

    abstract::Recent studies suggest that vortex ring formation during left ventricular (LV) rapid filling is an optimized mechanism for blood transport, and that the volume of the vortex ring is an important measure. However, due to lack of quantitative methods, the volume of the vortex ring has not previously been studied. Lagran...

    journal_title:Annals of biomedical engineering

    pub_type: 临床试验,杂志文章

    doi:10.1007/s10439-012-0615-3

    authors: Töger J,Kanski M,Carlsson M,Kovács SJ,Söderlind G,Arheden H,Heiberg E

    更新日期:2012-12-01 00:00:00

  • Computational approach to estimating the effects of blood properties on changes in intra-stent flow.

    abstract::In this study various blood rheological assumptions are numerically investigated for the hemodynamic properties of intra-stent flow. Non-newtonian blood properties have never been implemented in blood coronary stented flow investigation, although its effects appear essential for a correct estimation and distribution o...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-006-9123-7

    authors: Benard N,Perrault R,Coisne D

    更新日期:2006-08-01 00:00:00

  • Errors caused by combination of Di-4 ANEPPS and Fluo3/4 for simultaneous measurements of transmembrane potentials and intracellular calcium.

    abstract::Intracellular calcium concentration and transmembrane potentials are two important measurements used to study the mechanisms of cardiac activity. Fluorescent dyes have been used to measure these separately but not simultaneously in cardiac tissue. Fluo-3 and Fluo-4 (a recently improved version of Fluo-3) have been use...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.198

    authors: Johnson PL,Smith W,Baynham TC,Knisley SB

    更新日期:1999-07-01 00:00:00

  • Restoring Ovarian Endocrine Function with Encapsulated Ovarian Allograft in Immune Competent Mice.

    abstract::Premature ovarian insufficiency (POI) is a major complication of cytotoxic treatments due to extreme ovarian sensitivity to chemotherapy and radiation. In pediatric cancer patients modern therapy has improved the long-term survival to over 80% in the United States. However, these cancer survivors face long-term health...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-016-1780-6

    authors: David A,Day JR,Cichon AL,Lefferts A,Cascalho M,Shikanov A

    更新日期:2017-07-01 00:00:00

  • Effects of chamber shape and fiber orientation on relations between fiber dynamics and chamber dynamics.

    abstract::The function of a chamber depends on its hydrodynamic properties: isometric pressures it can exert in the operating range of distensions, compliances in the operating range of distensions, and wall-displacement resistances in the operating range of distensions. Wall-displacement resistance is the departure of pressure...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02368017

    authors: Regen DM

    更新日期:1988-01-01 00:00:00

  • A piconewton force transducer and its application to measurement of the bending stiffness of phospholipid membranes.

    abstract::The bending stiffness of a phospholipid bilayer (Kc) was measured by forming thin bilayer cylinders (tethers) from giant phospholipid vesicles. Based on the balance of forces, the tether force was expected to be proportional to the square root of the membrane tension, with a constant of proportionality containing Kc. ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02684228

    authors: Heinrich V,Waugh RE

    更新日期:1996-09-01 00:00:00

  • Neurite outgrowth on a DNA crosslinked hydrogel with tunable stiffnesses.

    abstract::Mechanical cues arising from extracellular matrices greatly affect cellular properties, and hence, are of significance in designing biomaterials. In this study, a DNA crosslinked hydrogel was employed to examine cellular responses of spinal cord neurons to substrate compliances. Using DNA as crosslinkers in polymeric ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-008-9530-z

    authors: Jiang FX,Yurke B,Firestein BL,Langrana NA

    更新日期:2008-09-01 00:00:00

  • A computer reconstruction of the entire coronary arterial tree based on detailed morphometric data.

    abstract::A rigorous analysis of blood flow must be based on the branching pattern and vascular geometry of the full vascular circuit of interest. It is experimentally difficult to reconstruct the entire vascular circuit of any organ because of the enormity of the vessels. The objective of the present study was to develop a nov...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-005-5758-z

    authors: Mittal N,Zhou Y,Ung S,Linares C,Molloi S,Kassab GS

    更新日期:2005-08-01 00:00:00

  • An in vitro evaluation of the impact of eccentric deployment on transcatheter aortic valve hemodynamics.

    abstract::Patients with aortic stenosis present with calcium deposits on the native aortic valve, which can result in non-concentric expansion of Transcatheter Aortic Valve Replacement (TAVR) stents. The objective of this study is to evaluate whether eccentric deployment of TAVRs lead to turbulent blood flow and blood cell dama...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-014-1008-6

    authors: Gunning PS,Saikrishnan N,McNamara LM,Yoganathan AP

    更新日期:2014-06-01 00:00:00

  • A novel left heart simulator for the multi-modality characterization of native mitral valve geometry and fluid mechanics.

    abstract::Numerical models of the mitral valve have been used to elucidate mitral valve function and mechanics. These models have evolved from simple two-dimensional approximations to complex three-dimensional fully coupled fluid structure interaction models. However, to date these models lack direct one-to-one experimental val...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-012-0651-z

    authors: Rabbah JP,Saikrishnan N,Yoganathan AP

    更新日期:2013-02-01 00:00:00