Retinal vascular permeability determined by dual-tracer fluorescence angiography.

Abstract:

:Diabetic retinopathy is the leading cause of blindness in working age individuals in the United States. Breakdown of the blood-retinal barrier is one of the earliest events in the progression of diabetic retinopathy. Ideally, therapeutic measures would be directed at this early stage, but there are few sensitive, quantitative methods to assess the retinal vascular barrier in vivo. We present here a method that combines fluorescence microangiography and the simultaneous use of two fluorescent tracers to quantitatively assess the retinal vascular barrier. PS/F (permeability x surface area/flow) describing the retinal vasculature of Long Evans rats was found to be 0.086+/-0.031 (n=13, avg.+/-s.d.). Based on estimates of flow and surface area, we estimate the permeability of sodium fluorescein to be approximately 1.2 x 10(-5) cm/s. Infusion of a hyperosmolar solution of 1.6 M mannitol for 5 min significantly increased PS/F in individual veins and significantly increased a flow weighted PS/F from 0.073+/-0.028 to 0.16+/-0.034 (n=3). In conclusion, we have adapted indicator dilution techniques to quantitatively assess the retinal vasculature in vivo. We have found dual-tracer fluorescence angiography to be a sensitive indicator of increases in the blood-retinal barrier produced by hyperosmolar mannitol. This methodology is a promising new minimally invasive strategy which may be adapted to quantitatively track retinal vascular permeability.

journal_name

Ann Biomed Eng

authors

Russ PK,Gaylord GM,Haselton FR

doi

10.1114/1.1385809

subject

Has Abstract

pub_date

2001-08-01 00:00:00

pages

638-47

issue

8

eissn

0090-6964

issn

1573-9686

journal_volume

29

pub_type

杂志文章
  • Body Anthropometry and Bone Strength Conjointly Determine the Risk of Hip Fracture in a Sideways Fall.

    abstract::We hypothesize that variations of body anthropometry, conjointly with the bone strength, determine the risk of hip fracture. To test the hypothesis, we compared, in a simulated sideways fall, the hip impact energy to the energy needed to fracture the femur. Ten femurs from elderly donors were tested using a novel drop...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02682-y

    authors: Palanca M,Perilli E,Martelli S

    更新日期:2020-11-12 00:00:00

  • Stress relaxation preconditioning of porcine aortic valves.

    abstract::In uniaxial tensile testing, load preconditioning is used to generate repeatable load/elongation curves and set a "reference state" for subsequent tensile tests. We have observed however, that for porcine aortic valve (PAV) tissues, preconditioning does not lead to repeatable stress relaxation curves. We thus investig...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1023/b:abme.0000019176.49650.19

    authors: Carew EO,Garg A,Barber JE,Vesely I

    更新日期:2004-04-01 00:00:00

  • Quantitative analysis of molecular absorption into PDMS microfluidic channels.

    abstract::Microfluidic devices fabricated using poly(dimethylsiloxane) (PDMS) polymer are routinely used for in vitro cell culture for a wide range of cellular assays. These assays typically involve the incubation of cultured cells with a drug molecule or a fluorescent marker while monitoring a cellular response. The accuracy o...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-012-0562-z

    authors: Wang JD,Douville NJ,Takayama S,ElSayed M

    更新日期:2012-09-01 00:00:00

  • Comparison of Covered Laser-cut and Braided Respiratory Stents: From Bench to Pre-Clinical Testing.

    abstract::Lung cancer patients often suffer from severe airway stenosis, the symptoms of which can be relieved by the implantation of stents. Different respiratory stents are commercially available, but the impact of their mechanical performance on tissue responses is not well understood. Two novel laser-cut and hand-braided ni...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-019-02278-1

    authors: Thiebes AL,McGrath DJ,Kelly N,Sweeney CA,Kurtenbach K,Gesché VN,Clauser J,O'Brien B,Bruzzi M,McHugh PE,Jockenhoevel S,Cornelissen CG

    更新日期:2019-08-01 00:00:00

  • Hierarchical CT to Ultrasound Registration of the Lumbar Spine: A Comparison with Other Registration Methods.

    abstract::Three-dimensional (3D) measurement of the spine can provide important information for functional, developmental, diagnostic, and treatment-effect evaluations. However, existing measurement techniques are either 2-dimensional, highly invasive, or involve a high radiation dose, prohibiting their widespread and repeated ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-016-1599-1

    authors: Koo TK,Kwok WE

    更新日期:2016-10-01 00:00:00

  • Soft 3D-Printed Phantom of the Human Kidney with Collecting System.

    abstract::Organ models are used for planning and simulation of operations, developing new surgical instruments, and training purposes. There is a substantial demand for in vitro organ phantoms, especially in urological surgery. Animal models and existing simulator systems poorly mimic the detailed morphology and the physical pr...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-016-1757-5

    authors: Adams F,Qiu T,Mark A,Fritz B,Kramer L,Schlager D,Wetterauer U,Miernik A,Fischer P

    更新日期:2017-04-01 00:00:00

  • Measurement of in vivo stress resultants in neurulation-stage amphibian embryos.

    abstract::In order to obtain the first quantitative measurements of the in vivo stresses in early-stage amphibian embryos, we developed a novel instrument that uses a pair of parallel wires that are glued to the surface of an embryo normal to the direction in which the stress is to be determined. When a slit is made parallel to...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-006-9250-1

    authors: Benko R,Brodland GW

    更新日期:2007-04-01 00:00:00

  • Enhancement of stent-induced thromboembolism by residual stenoses: contribution of hemodynamics.

    abstract::In vitro stent-induced thromboembolism was altered by the presence of residual stenoses placed upstream or placed upstream and downstream of the stent. Heparinized (3 micro/ml) bovine blood was gravity fed through a conduit with a deployed coronary stent. Embolism was continuously monitored using a light-scattering mi...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.243

    authors: Sukavaneshvar S,Rosa GM,Solen KA

    更新日期:2000-02-01 00:00:00

  • Mathematical simulation of slowing of cardiac conduction velocity by elevated extracellular.

    abstract::We have studied the dependence of conduction velocity (theta) on extracellular potassium concentration ([K+]o) in a model of one-dimensional conduction using an idealized strand of human atrial cells. Elevated [K+]o in the 5-20 mM range shifts the resting potential (Vrest) in the depolarizing direction and reduces inp...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1308489

    authors: Nygren A,Giles WR

    更新日期:2000-08-01 00:00:00

  • A model of electrical conduction in cardiac tissue including fibroblasts.

    abstract::Fibroblasts are abundant in cardiac tissue. Experimental studies suggested that fibroblasts are electrically coupled to myocytes and this coupling can impact cardiac electrophysiology. In this work, we present a novel approach for mathematical modeling of electrical conduction in cardiac tissue composed of myocytes, f...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-009-9667-4

    authors: Sachse FB,Moreno AP,Seemann G,Abildskov JA

    更新日期:2009-05-01 00:00:00

  • BMP-2 gene modified canine bMSCs promote ectopic bone formation mediated by a nonviral PEI derivative.

    abstract::The study was to explore the effects of BMP-2 gene modified canine bone marrow stromal cells (bMSCs) mediated by a nonviral PEI derivative (GenEscort™ II) in promoting bone formation in vitro and in vivo. Canine bMSCs were cultured and transfected with plasmids containing bone morphogenetic protein-2 gene (pBMP-2) or ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-011-0276-7

    authors: Lü K,Zeng D,Zhang Y,Xia L,Xu L,Kaplan DL,Jiang X,Zhang F

    更新日期:2011-06-01 00:00:00

  • A model for detecting balance impairment and estimating falls risk in the elderly.

    abstract::Traumatic falls are a prevalent and costly threat to elderly adults. Accurate risk assessment is necessary for reducing incidence of falls. The objective of this study was to test the feasibility of a balance impairment detection model using tasks of sample categorization and falls risk estimation. Model design includ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-005-2867-7

    authors: Hahn ME,Chou LS

    更新日期:2005-06-01 00:00:00

  • Computational study of proteolysis-driven single cell migration in a three-dimensional matrix.

    abstract::Cell migration is a fundamental process that is crucial to a variety of physiological events. While traditional approaches have focused on two-dimensional (2D) systems, recent efforts have shifted to studying migration in three-dimensional (3D) matrices. A major distinction that has emerged is the increased importance...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-9970-0

    authors: Harjanto D,Zaman MH

    更新日期:2010-05-01 00:00:00

  • Progression of abdominal aortic aneurysm towards rupture: refining clinical risk assessment using a fully coupled fluid-structure interaction method.

    abstract::Rupture of abdominal aortic aneurysm (AAA) is associated with high mortality rates. Risk of rupture is multi-factorial involving AAA geometric configuration, vessel tortuosity, and the presence of intraluminal pathology. Fluid structure interaction (FSI) simulations were conducted in patient based computed tomography ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-014-1224-0

    authors: Xenos M,Labropoulos N,Rambhia S,Alemu Y,Einav S,Tassiopoulos A,Sakalihasan N,Bluestein D

    更新日期:2015-01-01 00:00:00

  • Use of pseudorandom noise in studies of auditory evoked potentials.

    abstract::The extent to which sensorineural systems such as the auditory system are nonlinear depends on the type of stimulus that is used, and the part of the system from which recordings are made. An estimate of the first-order Wiener kernel of the evoked response from the inferior colliculus to amplitude-modulated tones and ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02367379

    authors: Møller AR,Angelo RM

    更新日期:1988-01-01 00:00:00

  • An Integrated In Vitro-In Silico Approach for Silver Nanoparticle Dosimetry in Cell Cultures.

    abstract::Potential human and environmental hazards resulting from the exposure of living organisms to silver nanoparticles (Ag NPs) have been the subject of intensive discussion in the last decade. Despite the growing use of Ag NPs in biomedical applications, a quantification of the toxic effects as a function of the total sil...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02449-5

    authors: Poli D,Mattei G,Ucciferri N,Ahluwalia A

    更新日期:2020-04-01 00:00:00

  • A finite volume method for modeling discontinuous electrical activation in cardiac tissue.

    abstract::This paper describes a finite volume method for modeling electrical activation in a sample of cardiac tissue using the bidomain equations. Microstructural features to the level of cleavage planes between sheets of myocardial fibers in the tissue are explicitly represented. The key features of this implementation compa...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-005-1434-6

    authors: Trew M,Le Grice I,Smaill B,Pullan A

    更新日期:2005-05-01 00:00:00

  • Estimating the parameter distributions of defibrillation shock efficacy curves in a large population.

    abstract::Defibrillation efficacy testing is a common procedure at defibrillator implantation, with the objective to ensure that each patient receives a system with adequate shock efficacy. In this study, defibrillation shock efficacy as a function of shock energy was modeled by a dose response relationship. The frequency distr...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-009-9890-z

    authors: Smits K,Virag N

    更新日期:2010-04-01 00:00:00

  • Mathematical models of the spatial distribution of retinal oxygen tension and consumption, including changes upon illumination.

    abstract::To better understand oxygen utilization by the retina, a mathematical model of oxygen diffusion and consumption in the cat outer, avascular retina was developed by analyzing previously recorded profiles of oxygen tension (PO2) as a function of retinal depth. Simple diffusion modelling of the oxygen distribution throug...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02368415

    authors: Haugh LM,Linsenmeier RA,Goldstick TK

    更新日期:1990-01-01 00:00:00

  • Strontium ranelate prevents bone loss in a rat model of localized muscle paralysis.

    abstract::Twenty-one 3.5-month-old female Sprague-Dawley rats were randomly assigned to three groups: BTX group, in which each rat received a single intramuscular injection of 2 U of Clostridium botulinum toxin (BTX) in the quadriceps femoris muscle of the right hind limb; BTX + SR group, in which each rat received a BTX inject...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-011-0406-2

    authors: Sheng ZF,Ma YL,Tong D,Fang DY,Liang QC,Liu LH,Zhang J,Liao EY

    更新日期:2012-03-01 00:00:00

  • Chondrogenesis and integration of mesenchymal stem cells within an in vitro cartilage defect repair model.

    abstract::Integration of repair tissue is a key indicator of the long-term success of cell-based therapies for cartilage repair. The objective of this study was to compare the in vitro chondrogenic differentiation and integration of agarose hydrogels seeded with either chondrocytes or bone marrow-derived mesenchymal stem cells ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-009-9791-1

    authors: Vinardell T,Thorpe SD,Buckley CT,Kelly DJ

    更新日期:2009-12-01 00:00:00

  • Influence of autoregressive model parameter uncertainty on spectral estimates of heart rate dynamics.

    abstract::Linear autoregressive (AR) model-based heart rate (HR) spectral analysis has been widely used to study HR dynamics. Owing to system and measurement noise, the parameters of an AR model have intrinsic statistical uncertainty. In this study, we evaluate how this AR parameter uncertainty can translate to uncertainty in H...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02368320

    authors: Christini DJ,Kulkarni A,Rao S,Stutman ER,Bennett FM,Hausdorff JM,Oriol N,Lutchen KR

    更新日期:1995-03-01 00:00:00

  • Theory of the oscillometric maximum and the systolic and diastolic detection ratios.

    abstract::It is proposed that the maximum in cuff pressure oscillations during oscillometry is due to the buckling of the brachial artery under a cuff. This theory is investigated by means of a mathematical model of oscillatometry that includes the mechanics of the occlusive arm cuff, the arterial pressure pulse waveform, and t...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02368225

    authors: Drzewiecki G,Hood R,Apple H

    更新日期:1994-01-01 00:00:00

  • Investigating the relationship between fetus EEG, respiratory, and blood pressure signals during maturation using wavelet transform.

    abstract::In this study, we introduce the fast wavelet transform as a method for characterizing maturational changes in electrocortical activity, respiratory activity, and blood pressure in fetal lambs in early (110-122 days), mid (123-135 days), and late (136-144 days) third trimester (term 145 days). Each recording was 2 hr i...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02584457

    authors: Akay M,Szeto HH

    更新日期:1995-09-01 00:00:00

  • Perspectives on Bioengineering Clinical Immersion: History, Innovation, and Impact.

    abstract::Opportunities to provide clinical immersion experiences to bioengineering undergraduate students have expanded over the last several years. These programs allow students to observe the clinical environment in order to better understand workflow processes, the context in which medical equipment is used, and identify un...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02508-x

    authors: Kotche M,Felder AE,Wilkens K,Stirling S

    更新日期:2020-09-01 00:00:00

  • Native, living tissues as cell seeded scaffolds.

    abstract::Much effort is expended in developing biomimetic scaffolds that provide the micro-architecture of native tissue with appropriate cellular niches. Such scaffolds are often seeded with progenitor cells to generate engineered replacements for diseased or damaged tissues. An alternative approach relies on biology, rather ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/s10439-014-1174-6

    authors: Evans CH

    更新日期:2015-03-01 00:00:00

  • Vortex ring formation in the left ventricle of the heart: analysis by 4D flow MRI and Lagrangian coherent structures.

    abstract::Recent studies suggest that vortex ring formation during left ventricular (LV) rapid filling is an optimized mechanism for blood transport, and that the volume of the vortex ring is an important measure. However, due to lack of quantitative methods, the volume of the vortex ring has not previously been studied. Lagran...

    journal_title:Annals of biomedical engineering

    pub_type: 临床试验,杂志文章

    doi:10.1007/s10439-012-0615-3

    authors: Töger J,Kanski M,Carlsson M,Kovács SJ,Söderlind G,Arheden H,Heiberg E

    更新日期:2012-12-01 00:00:00

  • Reproducibility of image-based computational fluid dynamics models of the human carotid bifurcation.

    abstract::Recent studies have demonstrated the ability of magnetic resonance imaging (MRI) to provide anatomically realistic boundary conditions for computational fluid dynamics (CFD) simulations of arterial hemodynamics. To date, however, little is known about the overall reproducibility of such image-based CFD techniques. Tow...

    journal_title:Annals of biomedical engineering

    pub_type: 临床试验,杂志文章

    doi:10.1114/1.1540102

    authors: Thomas JB,Milner JS,Rutt BK,Steinman DA

    更新日期:2003-02-01 00:00:00

  • Multiscale Modeling in the Clinic: Drug Design and Development.

    abstract::A wide range of length and time scales are relevant to pharmacology, especially in drug development, drug design and drug delivery. Therefore, multiscale computational modeling and simulation methods and paradigms that advance the linkage of phenomena occurring at these multiple scales have become increasingly importa...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/s10439-016-1563-0

    authors: Clancy CE,An G,Cannon WR,Liu Y,May EE,Ortoleva P,Popel AS,Sluka JP,Su J,Vicini P,Zhou X,Eckmann DM

    更新日期:2016-09-01 00:00:00

  • Intrinsic oscillations and discharge regularity of units in the dorsal cochlear nucleus (DCN) of the barbiturate anesthetized gerbil.

    abstract::Spike discharge patterns showing intrinsic oscillations (IOs) have been reported in units in the dorsal cochlear nucleus (DCN) of the decerebrate cat. These oscillations are related to the regularity of a unit's discharge rate and may be important for pitch perception. A DCN unit's regularity can be affected by severa...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.96

    authors: Gdowski GT,Voigt HF

    更新日期:1998-05-01 00:00:00