Abstract:
:We hypothesize that variations of body anthropometry, conjointly with the bone strength, determine the risk of hip fracture. To test the hypothesis, we compared, in a simulated sideways fall, the hip impact energy to the energy needed to fracture the femur. Ten femurs from elderly donors were tested using a novel drop-tower protocol for replicating the hip fracture dynamics during a fall on the side. The impact energy was varied for each femur according to the donor's body weight, height and soft-tissue thickness, by adjusting the drop height and mass. The fracture pattern, force, energy, strain in the superior femoral neck, bone morphology and microarchitecture were evaluated. Fracture patterns were consistent with clinically relevant hip fractures, and the superior neck strains and timings were comparable with the literature. The hip impact energy (11 - 95 J) and the fracture energy (11 - 39 J) ranges overlapped and showed comparable variance (CV = 69 and 61%, respectively). The aBMD-based definition of osteoporosis correctly classified 7 (70%) fracture/non-fracture cases. The incorrectly classified cases presented large impact energy variations, morphology variations and large subcortical voids as seen in microcomputed tomography. In conclusion, the risk of osteoporotic hip fracture in a sideways fall depends on both body anthropometry and bone strength.
journal_name
Ann Biomed Engjournal_title
Annals of biomedical engineeringauthors
Palanca M,Perilli E,Martelli Sdoi
10.1007/s10439-020-02682-ysubject
Has Abstractpub_date
2020-11-12 00:00:00eissn
0090-6964issn
1573-9686pii
10.1007/s10439-020-02682-ypub_type
杂志文章abstract::We investigate the potential of prosthetic heart valves to generate abnormal flow and stress patterns, which can contribute to platelet activation and lysis according to blood damage accumulation mechanisms. High-resolution velocity measurements of the unsteady flow field, obtained with a standard particle image veloc...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-011-0329-y
更新日期:2011-09-01 00:00:00
abstract::A multifunctional FePt nanoparticle was developed that targets tumor microvasculature via "radiation-guided" peptides, and is detected by both near-infrared (NIR) fluorescence imaging and analytical mass spectrometry methods. Tumor specific binding was first measured by biotinylated peptide linked to fluorophore-conju...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-010-0219-8
更新日期:2011-03-01 00:00:00
abstract::Further understanding of the mechanical deformation and tear behavior of kidney during suturing helps to enhance surgical task execution that requires fine suture manipulation. This paper aims to develop a model to describe the relationship between the tensile force acting on suture line and the resulted kidney deform...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-012-0722-1
更新日期:2013-04-01 00:00:00
abstract::Knowledge of strain-rate sensitivity of soft tissue viscoelastic and nonlinear elastic properties is important for accurate predictions of biomechanical behavior and for quantitative assessment of the effects of disease or surgical/pharmaceutical intervention. Soft tissues are known to exhibit mild rate sensitivity, b...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1023/b:abme.0000012742.01261.b0
更新日期:2004-02-01 00:00:00
abstract::Fractal time series analysis methods are commonly used for analyzing center of pressure (COP) signals with the goal of revealing the underlying neuromuscular processes for upright stance control. The use of fractal methods is often coupled with the assumption that the COP is an instance of fractional Gaussian noise (f...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-012-0646-9
更新日期:2013-08-01 00:00:00
abstract::Mechanical properties of the cardiac tissue play an important role in normal heart function. The goal of this study was to determine the passive mechanical properties of all heart chambers through a paired comparison study in an ovine model. Ovine heart was used due its physiological and anatomical similarities to hum...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-016-1658-7
更新日期:2016-11-01 00:00:00
abstract::Local hemodynamics are an important factor in atherosclerosis, from the development of early lesions, to the assessment of stroke risk, to determining the ultimate fate of a mature plaque. Until recently, our understanding of arterial fluid dynamics and their relationship to atherosclerosis was limited by the use of i...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章,评审
doi:10.1114/1.1467679
更新日期:2002-04-01 00:00:00
abstract::Although it is known that long cortical bone structurally alter their area moment of inertia with age related bone loss maintaining their bending strength, the incidence of fragility fractures associated with cortical thinning still prevails. We hypothesize that cortical thinning with aging increases the local bucklin...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-009-9751-9
更新日期:2009-09-01 00:00:00
abstract::We present here the first quantitative correlation for cell contact guidance in an oriented fibrillar network in terms of biased cell migration. The correlation is between the anisotropic cell diffusion parameter, DA = Dx/Dy, and the collagen gel birefringence, delta n, a measure of axially biased collagen fibril orie...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/BF02368241
更新日期:1994-07-01 00:00:00
abstract::The local dilation of the infrarenal abdominal aorta, termed an abdominal aortic aneurysm (AAA), is often times asymptomatic and may eventually result in rupture-an event associated with a significant mortality rate. The estimation of in-vivo stresses within AAAs has been proposed as a useful tool to predict the likel...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-008-9490-3
更新日期:2008-06-01 00:00:00
abstract::This study presents a novel approach to modeling the electrocardiogram (ECG): the Gaussian pulse decomposition. Constituent waves of the ECG are decomposed into and represented by Gaussian pulses using an iterative algorithm: the chip away decomposition (ChAD) algorithm. At each iteration, a nonlinear minimization met...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/BF02648039
更新日期:1997-03-01 00:00:00
abstract::A progressive reduction in muscle fiber conduction velocity is typically observed during fatiguing muscle contraction. Although the exact causes of the conduction velocity decrease have not yet been fully established, increasing evidence suggests that changes in extracellular potassium concentration may be largely res...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-009-9756-4
更新日期:2009-10-01 00:00:00
abstract::Elastin is an essential component of arteries which provides structural integrity and instructs smooth muscle cells to adopt a quiescent state. Despite interaction of endothelial cells with elastin in the internal elastic lamina, the potential for exploiting this interaction therapeutically has not been explored in de...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-010-0142-z
更新日期:2011-01-01 00:00:00
abstract::Intraluminal thrombus (ILT) is a pseudo-tissue that develops from coagulated blood, and is found in most abdominal aortic aneurysms (AAAs) of clinically relevant size. A number of studies have suggested that ILT mechanical characteristics may be related to AAA risk of rupture, even though there is still great controve...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-015-1267-x
更新日期:2015-09-01 00:00:00
abstract::Pathologic vascular adaptation following local injury is the primary driver for accelerated intimal hyperplasia and an occlusive phenotype. Smooth muscle cell (SMC) proliferation within the wall, and migration into the developing intima, is a major component of this remodeling response. The primary objective in the cu...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-016-1725-0
更新日期:2017-03-01 00:00:00
abstract::Children with cerebral palsy frequently experience foot dragging and tripping during walking due to a lack of adequate knee flexion in swing (stiff-knee gait). Stiff-knee gait is often accompanied by an overly flexed knee during stance (crouch gait). Studies on stiff-knee gait have mostly focused on excessive knee mus...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-010-9952-2
更新日期:2010-04-01 00:00:00
abstract::Magnetic (eddy-current) stimulation of the inspiratory motor nerves in the neck of the anesthetized dog was achieved. Using a 10-turn coil wound around the base of the neck and a train of pulses (25/s), inspiration was produced by tetanic contraction of the inspiratory muscles. The volume of air inspired increased wit...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/BF02368176
更新日期:1993-05-01 00:00:00
abstract::This experiment investigates the validity of six thermometers with different measuring sensors, operation and site of application, to estimate core temperature (Tc) in comparison to an ingestible thermometric sensor based on quartz crystal technology. Measurements were obtained before, during and after exercise in the...
journal_title:Annals of biomedical engineering
pub_type: 临床试验,杂志文章
doi:10.1007/s10439-018-02115-x
更新日期:2019-01-01 00:00:00
abstract::A goal of the Human Research Program at National Aeronautics and Space Administration (NASA) is to analyze and mitigate the risk of occupant injury due to dynamic loads. Experimental tests of human subjects and biofidelic anthropomorphic test devices provide valuable kinematic and kinetic data related to injury risk e...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-018-02147-3
更新日期:2019-02-01 00:00:00
abstract::Understanding the complex spatiotemporal dynamics of action potential propagation in the heart during arrhythmia is exceedingly difficult. This study applies nonlinear dynamics tools to simplify this task. Using the results of a simulation of an electrical induction of reentry in a sheet of myocardium represented as a...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1114/1.1581289
更新日期:2003-07-01 00:00:00
abstract::Therapeutic irradiation is commonly used in the treatment of malignant brain tumors and has the potential to cause severe injury to normal tissues adjacent to a lesion. Computed tomography (CT) can be used not only to visualize tissue damage but to monitor the development of a lesion using advanced quantitative CT tec...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/BF02410288
更新日期:1984-01-01 00:00:00
abstract::Intracellular calcium concentration and transmembrane potentials are two important measurements used to study the mechanisms of cardiac activity. Fluorescent dyes have been used to measure these separately but not simultaneously in cardiac tissue. Fluo-3 and Fluo-4 (a recently improved version of Fluo-3) have been use...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1114/1.198
更新日期:1999-07-01 00:00:00
abstract::Thorax injuries mainly due to rib fractures have been associated with high rates of morbidity and mortality in motor vehicle crashes. Thoracic biomechanics has been studied extensively, but there are no robust biomechanical response targets for ribs that consider age, sex, body size, and vulnerability factors. The obj...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-020-02613-x
更新日期:2021-02-01 00:00:00
abstract::Maintenance of movement accuracy relies on motor learning, by which prior errors guide future behavior. One aspect of this learning process involves the accurate generation of predictions of movement outcome. These predictions can, for example, drive anticipatory movements during a predictive-saccade task. Predictive ...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-012-0669-2
更新日期:2013-08-01 00:00:00
abstract::A novel apparatus for the multifaceted evaluation of artery function was developed. It measures endothelial and smooth muscle functions and the pressure-strain elastic modulus (E p). A rigid airtight chamber with an ultrasound probe was attached to the upper arm to manipulate the transmural pressure of the brachial ar...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-017-1810-z
更新日期:2017-06-01 00:00:00
abstract::There is a significant clinical need for engineered bone graft substitutes that can quickly, effectively, and safely repair large segmental bone defects. One emerging field of interest involves the growth of engineered bone tissue in vitro within bioreactors, the most promising of which are perfusion bioreactors. Usin...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-016-1662-y
更新日期:2016-12-01 00:00:00
abstract::One goal of large scale clinical trials is to determine how a drug is processed by, and cleared from, the human body [i.e., its pharmacokinetic (PK) properties] and how these PK properties differ between individuals in a population (i.e., its population PK properties). Due to the high cost of these studies and the lim...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1114/1.1533074
更新日期:2003-01-01 00:00:00
abstract::Human stem cells hold significant potential for the treatment of various diseases. However, their use as a therapy is hampered because of limited understanding of the mechanisms by which they respond to environmental stimuli. Efforts to understand extracellular biophysical cues have demonstrated the critical roles of ...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-018-2008-8
更新日期:2018-06-01 00:00:00
abstract::We present a method of measuring force response of a single living cell, attached to a substrate, in situ, by a functionalized microelectromechanical systems sensor that applies local deformation on the cell. The sensor is a single crystal silicon microcantilever beam with prescribed shape and geometry, and is coated ...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1114/1.1591189
更新日期:2003-09-01 00:00:00
abstract::Studying human cancer from a biomechanical perspective may contribute to pathogenesis understanding which leads to the malignancy. In this study, biomechanics of suspended and adhered breast cancer cells were investigated via the micropipette aspiration method with special emphasis on comparing the cell stiffness and ...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-019-02284-3
更新日期:2019-08-01 00:00:00