Abstract:
:Recent studies have demonstrated the ability of magnetic resonance imaging (MRI) to provide anatomically realistic boundary conditions for computational fluid dynamics (CFD) simulations of arterial hemodynamics. To date, however, little is known about the overall reproducibility of such image-based CFD techniques. Towards this end we used serial black blood and cine phase contrast MRI to reconstruct CFD models of the carotid bifurcations of three subjects with early atherosclerosis, each imaged three times at weekly intervals. The lumen geometry was found to be precise on average to within 0.15 mm or 5%, while measured flow and heart rates varied by less than 10%. Spatial patterns of a variety of wall shear stress (WSS) indices were largely preserved among the three repeat models. Time-averaged WSS was reproduced best, on average to within 5 dyn/cm2 or 37%, followed by WSS spatial gradients, angle gradients, and oscillatory shear index. The intrasubject flow rate variations were found to contribute little to the overall WSS variability. Instead, reproducibility was determined largely by the precision of the lumen boundary extraction from the individual MR images, itself shown to be a function of the image quality and proximity to the geometrically complex bifurcation region.
journal_name
Ann Biomed Engjournal_title
Annals of biomedical engineeringauthors
Thomas JB,Milner JS,Rutt BK,Steinman DAdoi
10.1114/1.1540102subject
Has Abstractpub_date
2003-02-01 00:00:00pages
132-41issue
2eissn
0090-6964issn
1573-9686journal_volume
31pub_type
临床试验,杂志文章abstract::Optimal treatment of proximal humerus fractures remains controversial. Locking plates offer theoretical advantages but are associated with complications in the clinic. This study aimed to perform parametric design optimisation of proximal humerus plates to enhance their mechanical performance. A finite element (FE) mo...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-018-02160-6
更新日期:2019-02-01 00:00:00
abstract::Opportunities to provide clinical immersion experiences to bioengineering undergraduate students have expanded over the last several years. These programs allow students to observe the clinical environment in order to better understand workflow processes, the context in which medical equipment is used, and identify un...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-020-02508-x
更新日期:2020-09-01 00:00:00
abstract::Of the many models of peripheral nerve in the literature, essentially all have relied on experimentally derived values for the anisotropic resistivity of the nerve bundle interstitial space. This paper is a comprehensive mathematical analysis of the most referenced experiment for the longitudinal and radial resistivit...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/BF02368054
更新日期:1989-01-01 00:00:00
abstract::In this paper, a novel cell stretcher design that mimics the real-time stretch of the heart wall is introduced. By culturing cells under stretched conditions that mimics the mechanical aspects of the native cardiac environment, better understanding on the role of biomechanical signaling on cell development can be achi...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-014-0976-x
更新日期:2014-05-01 00:00:00
abstract::Biomaterial-based tissue engineering strategies hold great promise for osteochondral tissue repair. Yet significant challenges remain in joining highly dissimilar materials to achieve a biomimetic, mechanically robust design for repairing interfaces between soft tissue and bone. This study sought to improve interfacia...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-015-1337-0
更新日期:2015-11-01 00:00:00
abstract::Collagen, the most commonly used extra-cellular matrix protein for tissue engineering applications, displays poor mechanical properties. Here, we report on the preparation and characterization of novel multi-component composite systems that incorporate a genetically engineered, biocompatible polymer (elastin-like poly...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-013-0825-3
更新日期:2013-10-01 00:00:00
abstract::Using a three-dimensional propagation model of the human ventricular myocardium, we studied the role of fibrous structure in generating epicardial potential maps. This model represents the myocardium as an anisotropic bidomain with an equal anisotropy ratio, and it incorporates a realistic representation of anatomical...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1114/1.73
更新日期:1998-11-01 00:00:00
abstract::Dexterity of robots is highly required when it comes to integration for medical applications. Major efforts have been conducted to increase the dexterity at the distal parts of medical robots. This paper reports on developments toward integrating biocompatible conducting polymers (CP) into inherently dexterous concent...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-018-2038-2
更新日期:2018-10-01 00:00:00
abstract::This study aimed to quantify the elongation patterns of the collateral ligaments following TKA during functional activities of daily living. Using mobile video-fluoroscopy to capture radiographic images of the knee in a group of six patients, each with an ultra-congruent knee implant, tibiofemoral kinematics were reco...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-020-02459-3
更新日期:2020-04-01 00:00:00
abstract::Membrane introduction mass spectrometry has been applied to inert gas measurements in blood and tissue, but gases with low blood solubility are associated with reduced sensitivity. Countercurrent extraction of inert gases from a blood sample into a water carrier phase has the potential to extract most of the gas sampl...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/BF02684170
更新日期:1997-09-01 00:00:00
abstract::Polymeric heart valves have the potential to reduce thrombogenic complications associated with current mechanical valves and overcome fatigue-related problems experienced by bioprosthetic valves. In this paper we characterize the in vitro velocity and Reynolds Shear Stress (RSS) fields inside and downstream of three d...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-006-9117-5
更新日期:2006-06-01 00:00:00
abstract::Recent advances in angioplasty have involved the application of polymer coatings to stent surfaces for purposes of drug delivery. Given the high levels of deformation developed in the plastic hinge of a stent during deployment, the achievement of an intact bond between the coating and the stent presents a significant ...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-010-9972-y
更新日期:2010-07-01 00:00:00
abstract::Presented is a discussion of steps towards the creation of a database of the microcirculation encompassing anatomical and functional experimental data, and conceptual and computational models. The discussion includes issues of database utility, organization, data deposition, and linkage to other databases. The databas...
journal_title:Annals of biomedical engineering
pub_type:
doi:10.1114/1.112
更新日期:1998-11-01 00:00:00
abstract::Dendritic cell (DC) migration is required for efficient presentation of antigen to T cells and the initiation of an adaptive immune response. In spite of its importance, many aspects of DC migration have not been characterized. DCs encounter a variety of environments with different stiffness and geometry, but the effe...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-018-2041-7
更新日期:2018-09-01 00:00:00
abstract::Asymmetric 75% and 95% area reduction, transparent Sylgard stenotic models were operated under internal carotid artery (ICA) [Womersley parameter, alpha=5.36, Re(mean) =213 and 180, respectively, and Re(peak)=734 and 410, respectively] and left anterior descending coronary artery (LAD) flow wave forms (alpha=2.65, Re(...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1114/1.131
更新日期:1998-03-01 00:00:00
abstract::Elastin is an essential component of arteries which provides structural integrity and instructs smooth muscle cells to adopt a quiescent state. Despite interaction of endothelial cells with elastin in the internal elastic lamina, the potential for exploiting this interaction therapeutically has not been explored in de...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-010-0142-z
更新日期:2011-01-01 00:00:00
abstract::Although it is known that long cortical bone structurally alter their area moment of inertia with age related bone loss maintaining their bending strength, the incidence of fragility fractures associated with cortical thinning still prevails. We hypothesize that cortical thinning with aging increases the local bucklin...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-009-9751-9
更新日期:2009-09-01 00:00:00
abstract::Biodegradable implants have demonstrated clinical success in simple applications (e.g., absorbable sutures) and have shown great potential in many other areas of interventional medicine, such as localized drug delivery, engineered tissue scaffolding, and structural implants. For endovascular stenting and musculoskelet...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-015-1477-2
更新日期:2016-02-01 00:00:00
abstract::In this study we present a novel, robust method to couple finite element (FE) models of cardiac mechanics to systems models of the circulation (CIRC), independent of cardiac phase. For each time step through a cardiac cycle, left and right ventricular pressures were calculated using ventricular compliances from the FE...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-006-9212-7
更新日期:2007-01-01 00:00:00
abstract::Traumatic falls are a prevalent and costly threat to elderly adults. Accurate risk assessment is necessary for reducing incidence of falls. The objective of this study was to test the feasibility of a balance impairment detection model using tasks of sample categorization and falls risk estimation. Model design includ...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-005-2867-7
更新日期:2005-06-01 00:00:00
abstract::Local hemodynamics are an important factor in atherosclerosis, from the development of early lesions, to the assessment of stroke risk, to determining the ultimate fate of a mature plaque. Until recently, our understanding of arterial fluid dynamics and their relationship to atherosclerosis was limited by the use of i...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章,评审
doi:10.1114/1.1467679
更新日期:2002-04-01 00:00:00
abstract::Skeletal muscles can be injured by their own contractions. Such contraction-induced injury, often accompanied by delayed onset of muscle soreness, is a leading cause of the loss of mobility in the rapidly increasing population of elderly people. Unlike other types of muscle injuries which hurt almost exclusively those...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章,评审
doi:10.1007/s10439-014-1173-7
更新日期:2015-02-01 00:00:00
abstract::The toxic or therapeutic effect of an inhaled aerosol is highly dependent upon the site and extent of deposition in the lung. A novel MRI-based method was used to quantify the spatial distribution of particles in the rat lung. Rats were exposed to 0.95 μm-diameter iron oxide particles in a controlled manner (N = 6) or...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-013-0745-2
更新日期:2013-05-01 00:00:00
abstract::The pericellular matrix (PCM) is a region of tissue that surrounds chondrocytes in articular cartilage and together with the enclosed cells is termed the chondron. Previous studies suggest that the mechanical properties of the PCM, relative to those of the chondrocyte and the extracellular matrix (ECM), may significan...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-005-4479-7
更新日期:2005-10-01 00:00:00
abstract::The aim of this study was to establish in vitro bench-tests of left atrial appendage occlusion (LAAo) devices regarding tug force, radial force and sealing capacity. Two LAAo devices, namely the WATCHMAN™ and the Occlutech®, of three different sizes underwent testing in novel dedicated in vitro setups. Radial force wa...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-018-2057-z
更新日期:2018-09-01 00:00:00
abstract::A number of human head finite element (FE) models have been developed from different research groups over the years to study the mechanisms of traumatic brain injury. These models can vary substantially in model features and parameters, making it important to evaluate whether simulation results from one model are read...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-013-0907-2
更新日期:2014-01-01 00:00:00
abstract::Early stage changes in hypertensive arteries have a significant effect on the long-term adaptation of the arteries. Compared to the long-term adaptation, little is known about the early dimensional and functional changes in hypertensive arteries in the first few days of hypertension. To study the early stage changes i...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1114/1.1376391
更新日期:2001-06-01 00:00:00
abstract::A study that customizes the feature generator parameters of an asynchronous Brain Interface (BI) is discussed. The goal is to detect the presence of a certain pattern, in the ongoing EEG, associated with a specific movement and to improve the system's performance. Results of this study show that customization mostly b...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-006-9097-5
更新日期:2006-06-01 00:00:00
abstract::An intelligent multichannel stimulator (IMS) has been designed and built for use in a cardiac research environment. The device is capable of measuring and responding to cardiac electrophysiological phenomena in real time with carefully timed and placed electrical stimuli. The system consists of 16 channels of sense/st...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1114/1.1451077
更新日期:2002-02-01 00:00:00
abstract::Mitral valve regurgitation (MVR) is common in patients receiving left ventricular assist device (LVAD) support, however the haemodynamic effect of MVR is not entirely clear. This study evaluated the haemodynamic effect of MVR with LVAD support and the influence of inflow cannulation site and LVAD speed modulation. Lef...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-016-1579-5
更新日期:2016-09-01 00:00:00