Zonal uniformity in mechanical properties of the chondrocyte pericellular matrix: micropipette aspiration of canine chondrons isolated by cartilage homogenization.

Abstract:

:The pericellular matrix (PCM) is a region of tissue that surrounds chondrocytes in articular cartilage and together with the enclosed cells is termed the chondron. Previous studies suggest that the mechanical properties of the PCM, relative to those of the chondrocyte and the extracellular matrix (ECM), may significantly influence the stress-strain, physicochemical, and fluid-flow environments of the cell. The aim of this study was to measure the biomechanical properties of the PCM of mechanically isolated chondrons and to test the hypothesis that the Young's modulus of the PCM varies with zone of origin in articular cartilage (surface vs. middle/deep). Chondrons were extracted from articular cartilage of the canine knee using mechanical homogenization, and the elastic properties of the PCM were determined using micropipette aspiration in combination with theoretical models of the chondron as an elastic incompressible half-space, an elastic compressible bilayer, or an elastic compressible shell. The Young's modulus of the PCM was significantly higher than that reported for isolated chondrocytes but over an order of magnitude lower than that of the cartilage ECM. No significant differences were observed in the Young's modulus of the PCM between surface zone (24.0 +/- 8.9 kPa) and middle/deep zone cartilage (23.2 +/- 7.1 kPa). In combination with previous theoretical biomechanical models of the chondron, these findings suggest that the PCM significantly influences the mechanical environment of the chondrocyte in articular cartilage and therefore may play a role in modulating cellular responses to micromechanical factors.

journal_name

Ann Biomed Eng

authors

Guilak F,Alexopoulos LG,Haider MA,Ting-Beall HP,Setton LA

doi

10.1007/s10439-005-4479-7

subject

Has Abstract

pub_date

2005-10-01 00:00:00

pages

1312-8

issue

10

eissn

0090-6964

issn

1573-9686

journal_volume

33

pub_type

杂志文章
  • Spectral analysis of Doppler flow velocity signals: assessment of objectives, methods, and interpretation.

    abstract::The objective of this paper is to review the theoretical basis and clinical application of electrical impedance plethysmography in the noninvasive evaluation of peripheral arterial and venous disease. Theoretical, experimental and clinical studies have not demonstrated a direct relationship between electrical impedanc...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02410294

    authors: Zuech PE,Cobbold RS,Johnston KW,Kassam M

    更新日期:1984-01-01 00:00:00

  • Body Anthropometry and Bone Strength Conjointly Determine the Risk of Hip Fracture in a Sideways Fall.

    abstract::We hypothesize that variations of body anthropometry, conjointly with the bone strength, determine the risk of hip fracture. To test the hypothesis, we compared, in a simulated sideways fall, the hip impact energy to the energy needed to fracture the femur. Ten femurs from elderly donors were tested using a novel drop...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02682-y

    authors: Palanca M,Perilli E,Martelli S

    更新日期:2020-11-12 00:00:00

  • Dynamics of revolution time variability in cycling pattern: voluntary intent can alter the long-range autocorrelations.

    abstract::Long-range dependency has been found in most rhythmic motor signals. The origin of this property is unknown and largely debated. There is a controversy on the influence of voluntary control induced by requiring a pre-determined pace such as asking subjects to step to a metronome. We studied the cycle duration variabil...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,随机对照试验

    doi:10.1007/s10439-013-0834-2

    authors: Warlop TB,Bollens B,Crevecoeur F,Detrembleur C,Lejeune TM

    更新日期:2013-08-01 00:00:00

  • Stochasticity in membrane-localized "ligand-receptor-G protein" binding: consequences for leukocyte movement behavior.

    abstract::The signal that governs the chemotactic response of mammalian white blood cells and tissue cells arises from membrane-localized binding events involving chemotactic factor ligands and receptors and G proteins. Fluctuations in this signal have been traditionally attributed to significant "noise" in receptor-ligand bind...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02584427

    authors: Moghe PV,Tranquillo RT

    更新日期:1995-05-01 00:00:00

  • Retinal vascular permeability determined by dual-tracer fluorescence angiography.

    abstract::Diabetic retinopathy is the leading cause of blindness in working age individuals in the United States. Breakdown of the blood-retinal barrier is one of the earliest events in the progression of diabetic retinopathy. Ideally, therapeutic measures would be directed at this early stage, but there are few sensitive, quan...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1385809

    authors: Russ PK,Gaylord GM,Haselton FR

    更新日期:2001-08-01 00:00:00

  • Resistances and compliances of a compartmental model of the cerebrovascular system.

    abstract::A lumped parameter compartmental model for the nonsteady flow of the cerebrovascular fluid is constructed. The model assumes constant resistances that relate fluid flux to pressure gradients, and compliances between compartments that relate fluid accumulation to rate of pressure changes. Resistances are evaluated by u...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02364270

    authors: Sorek S,Bear J,Karni Z

    更新日期:1989-01-01 00:00:00

  • Interaction between high frequency jet ventilation and cardiovascular function.

    abstract::We have studied the interaction of high frequency jet ventilation with cardiovascular pressures and flows. Results in dogs show that the amplitude of all intrathoracic pressures and flows fluctuate with a frequency equal to the difference between the heart rate and ventilator rate. The magnitude of this amplitude vari...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02584287

    authors: Mitzner W,Gioia F,Weinmann GG,Robotham JL,Ehrlich W

    更新日期:1987-01-01 00:00:00

  • Skull flexure as a contributing factor in the mechanism of injury in the rat when exposed to a shock wave.

    abstract::The manner in which energy from an explosion is transmitted into the brain is currently a highly debated topic within the blast injury community. This study was conducted to investigate the injury biomechanics causing blast-related neurotrauma in the rat. Biomechanical responses of the rat head under shock wave loadin...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-011-0343-0

    authors: Bolander R,Mathie B,Bir C,Ritzel D,VandeVord P

    更新日期:2011-10-01 00:00:00

  • Biomechanical Response Targets of Adult Human Ribs in Frontal Impacts.

    abstract::Thorax injuries mainly due to rib fractures have been associated with high rates of morbidity and mortality in motor vehicle crashes. Thoracic biomechanics has been studied extensively, but there are no robust biomechanical response targets for ribs that consider age, sex, body size, and vulnerability factors. The obj...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02613-x

    authors: Kang YS,Kwon HJ,Stammen J,Moorhouse K,Agnew AM

    更新日期:2021-02-01 00:00:00

  • The concept of using multifrequency energy transmission to reduce hot spots during deep-body hyperthermia.

    abstract::We propose a multifrequency energy transmission scheme for annular phased arrays in deep-body hyperthermia. The problem of frequency dependent resonance effects reported in hyperthermia phantom calibration studies, leading to skewed energy deposition patterns and unwanted energy maxima (hot spots), is addressed by com...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1430749

    authors: Jacobsen S,Melandsø F

    更新日期:2002-01-01 00:00:00

  • Effect of Drilling Techniques on Microcracks and Pull-Out Strength of Cortical Screw Fixed in Human Tibia: An In-Vitro Study.

    abstract::The strength between the cortical screw and bone following an orthopaedic implant surgery is an important determinant for the success of osteosynthesis. An excessive axial cutting force during drilling produces microcracks in the bone surface, resulting in reduced strength between the screw and bone, resulting in loos...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02565-2

    authors: Singh RP,Gupta V,Pandey PM,Mridha AR

    更新日期:2021-01-01 00:00:00

  • Phonocardiographic signal analysis method using a modified hidden Markov model.

    abstract::Auscultation is an important diagnostic indicator for cardiovascular analysis. Heart sound classification and analysis play an important role in the auscultative diagnosis. This study uses a combination of Mel-frequency cepstral coefficient (MFCC) and hidden Markov model (HMM) to efficiently extract the features for p...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-006-9232-3

    authors: Wang P,Lim CS,Chauhan S,Foo JY,Anantharaman V

    更新日期:2007-03-01 00:00:00

  • Characterization of biaxial mechanical behavior of porcine aorta under gradual elastin degradation.

    abstract::Arteries are composed of multiple constituents that endow the wall with proper structure and function. Many vascular diseases are associated with prominent mechanical and biological alterations in the wall constituents. In this study, planar biaxial tensile test data of elastase-treated porcine aortic tissue (Chow et ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-012-0733-y

    authors: Zeinali-Davarani S,Chow MJ,Turcotte R,Zhang Y

    更新日期:2013-07-01 00:00:00

  • Automatic Model Generation Framework for Computational Simulation of Cochlear Implantation.

    abstract::Recent developments in computational modeling of cochlear implantation are promising to study in silico the performance of the implant before surgery. However, creating a complete computational model of the patient's anatomy while including an external device geometry remains challenging. To address such a challenge, ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1541-y

    authors: Mangado N,Ceresa M,Duchateau N,Kjer HM,Vera S,Dejea Velardo H,Mistrik P,Paulsen RR,Fagertun J,Noailly J,Piella G,González Ballester MÁ

    更新日期:2016-08-01 00:00:00

  • Sustained Efficacy and Arterial Drug Retention by a Fast Drug Eluting Cross-Linked Fatty Acid Coronary Stent Coating.

    abstract::The long held assumption that sustained drug elution from stent coatings over weeks to months is imperative for clinical efficacy has limited the choice for stent coating materials. We developed and evaluated an omega-3 fatty acid (O3FA) based stent coating that is 85% absorbed and elutes 97% of its Sirolimus analog (...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1435-z

    authors: Artzi N,Tzafriri AR,Faucher KM,Moodie G,Albergo T,Conroy S,Corbeil S,Martakos P,Virmani R,Edelman ER

    更新日期:2016-02-01 00:00:00

  • Influence of different presentations of oscillometric data on automatic determination of systolic and diastolic pressures.

    abstract::Most non-invasive blood pressure measurements are based on either the auscultatory or the oscillometric technique. In this study, we performed an extensive analysis of the signals, i.e., responses of a microphone implanted in the cuff and pressure changes in the cuff, which can be recorded during such measurements. We...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-009-9853-4

    authors: Jazbinsek V,Luznik J,Mieke S,Trontelj Z

    更新日期:2010-03-01 00:00:00

  • 3D Printing of Calcium Phosphate Ceramics for Bone Tissue Engineering and Drug Delivery.

    abstract::Additive manufacturing, also known as 3D printing, has emerged over the past 3 decades as a disruptive technology for rapid prototyping and manufacturing. Vat polymerization, powder bed fusion, material extrusion, and binder jetting are distinct technologies of additive manufacturing, which have been used in a wide va...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/s10439-016-1678-3

    authors: Trombetta R,Inzana JA,Schwarz EM,Kates SL,Awad HA

    更新日期:2017-01-01 00:00:00

  • Bioreactors for development of tissue engineered heart valves.

    abstract::Millions of people worldwide are diagnosed each year with valvular heart disease, resulting in hundreds of thousands of valve replacement operations. Prosthetic valve replacements are designed to correct narrowing or backflow through the valvular orifice. Although commonly used, these therapies have serious disadvanta...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/s10439-010-0148-6

    authors: Berry JL,Steen JA,Koudy Williams J,Jordan JE,Atala A,Yoo JJ

    更新日期:2010-11-01 00:00:00

  • Chondrogenesis and integration of mesenchymal stem cells within an in vitro cartilage defect repair model.

    abstract::Integration of repair tissue is a key indicator of the long-term success of cell-based therapies for cartilage repair. The objective of this study was to compare the in vitro chondrogenic differentiation and integration of agarose hydrogels seeded with either chondrocytes or bone marrow-derived mesenchymal stem cells ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-009-9791-1

    authors: Vinardell T,Thorpe SD,Buckley CT,Kelly DJ

    更新日期:2009-12-01 00:00:00

  • Analyzing Remodeling of Cardiac Tissue: A Comprehensive Approach Based on Confocal Microscopy and 3D Reconstructions.

    abstract::Microstructural characterization of cardiac tissue and its remodeling in disease is a crucial step in many basic research projects. We present a comprehensive approach for three-dimensional characterization of cardiac tissue at the submicrometer scale. We developed a compression-free mounting method as well as labelin...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1465-6

    authors: Seidel T,Edelmann JC,Sachse FB

    更新日期:2016-05-01 00:00:00

  • Strontium ranelate prevents bone loss in a rat model of localized muscle paralysis.

    abstract::Twenty-one 3.5-month-old female Sprague-Dawley rats were randomly assigned to three groups: BTX group, in which each rat received a single intramuscular injection of 2 U of Clostridium botulinum toxin (BTX) in the quadriceps femoris muscle of the right hind limb; BTX + SR group, in which each rat received a BTX inject...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-011-0406-2

    authors: Sheng ZF,Ma YL,Tong D,Fang DY,Liang QC,Liu LH,Zhang J,Liao EY

    更新日期:2012-03-01 00:00:00

  • Fabrication and mechanical evaluation of anatomically-inspired quasilaminate hydrogel structures with layer-specific formulations.

    abstract::A major tissue engineering challenge is the creation of multilaminate scaffolds with layer-specific mechanical properties representative of native tissues, such as heart valve leaflets, blood vessels, and cartilage. For this purpose, poly(ethylene glycol) diacrylate (PEGDA) hydrogels are attractive materials due to th...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-012-0666-5

    authors: Tseng H,Cuchiara ML,Durst CA,Cuchiara MP,Lin CJ,West JL,Grande-Allen KJ

    更新日期:2013-02-01 00:00:00

  • Mechanical Performance of Two Left Atrial Appendage Occlusion Systems: In Vitro Comparison of Tug Force, Radial Force, Sealing and Deformation.

    abstract::The aim of this study was to establish in vitro bench-tests of left atrial appendage occlusion (LAAo) devices regarding tug force, radial force and sealing capacity. Two LAAo devices, namely the WATCHMAN™ and the Occlutech®, of three different sizes underwent testing in novel dedicated in vitro setups. Radial force wa...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-018-2057-z

    authors: Menne MF,Schrickel JW,Nickenig G,Al-Kassou B,Nelles D,Schmitz-Rode T,Steinseifer U,Sedaghat A

    更新日期:2018-09-01 00:00:00

  • A Wearable Magnet-Based System to Assess Activity and Joint Flexion in Humans and Large Animals.

    abstract::Functional outcomes, such as joint flexion and gait, are important indicators of efficacy in musculoskeletal research. Current technologies that objectively assess these parameters, including visual tracking systems and force plates, are challenging to deploy in long-term translational and clinical studies. To that en...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-018-2105-8

    authors: Qu F,Stoeckl BD,Gebhard PM,Hullfish TJ,Baxter JR,Mauck RL

    更新日期:2018-12-01 00:00:00

  • Engineering structurally organized cartilage and bone tissues.

    abstract::The field of tissue engineering promises to deliver biological substitutes to repair or replace tissues in the body that have been injured or diseased. The clinical demand for musculoskeletal tissues is particularly high, especially for cartilage and bone defects. Although they are generally considered biologically si...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1023/b:abme.0000007799.60142.78

    authors: Sharma B,Elisseeff JH

    更新日期:2004-01-01 00:00:00

  • Aortic Valve Function Under Support of a Left Ventricular Assist Device: Continuous vs. Dynamic Speed Support.

    abstract::Continuous flow left ventricular devices (CF-LVADs) support the failing heart at a constant speed and alters the loads on the aortic valve. This may cause insufficiency in the aortic valve under long-term CF-LVAD support. The aim of this study is to assess the aortic valve function under varying speed CF-LVAD support....

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-014-1204-4

    authors: Bozkurt S,van de Vosse FN,Rutten MC

    更新日期:2015-08-01 00:00:00

  • Simulated epicardial potential maps during paced activation reflect myocardial fibrous structure.

    abstract::Using a three-dimensional propagation model of the human ventricular myocardium, we studied the role of fibrous structure in generating epicardial potential maps. This model represents the myocardium as an anisotropic bidomain with an equal anisotropy ratio, and it incorporates a realistic representation of anatomical...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.73

    authors: Hren R,Nenonen J,Horácek BM

    更新日期:1998-11-01 00:00:00

  • Selective stimulation of latissimus dorsi muscle for cardiac assist.

    abstract::The contractile power of the latissimus dorsi muscle (LDM) is used in skeletal muscle cardiac assist (SMCA) to augment the blood pumping ability of a failing heart. The LDM has three anatomically distinct, independently innervate segments-the transverse, oblique, and lateral. There are potential advantages to selectiv...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.164

    authors: Thompson DR,Michele JJ,Cheever EA,George DT

    更新日期:1999-01-01 00:00:00

  • Mesh Convergence Behavior and the Effect of Element Integration of a Human Head Injury Model.

    abstract::Numerous head injury models exist that vary in mesh density by orders of magnitude. A careful study of the mesh convergence behavior is necessary, especially in terms of strain most relevant to brain injury. To this end, as well as to investigate the effect of element integration scheme on simulated strains, we re-mes...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-018-02159-z

    authors: Zhao W,Ji S

    更新日期:2019-02-01 00:00:00

  • Computational study of proteolysis-driven single cell migration in a three-dimensional matrix.

    abstract::Cell migration is a fundamental process that is crucial to a variety of physiological events. While traditional approaches have focused on two-dimensional (2D) systems, recent efforts have shifted to studying migration in three-dimensional (3D) matrices. A major distinction that has emerged is the increased importance...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-9970-0

    authors: Harjanto D,Zaman MH

    更新日期:2010-05-01 00:00:00