Biomechanical Challenges to Polymeric Biodegradable Stents.

Abstract:

:Biodegradable implants have demonstrated clinical success in simple applications (e.g., absorbable sutures) and have shown great potential in many other areas of interventional medicine, such as localized drug delivery, engineered tissue scaffolding, and structural implants. For endovascular stenting and musculoskeletal applications, they can serve as temporary mechanical support that provides a smooth stress-transfer from the degradable implant to the healing tissue. However, for more complex device geometries, in vivo environments, and evolving load-bearing functions, such as required for vascular stents, there are considerable challenges associated with the use of biodegradable materials. A biodegradable stent must restore blood flow and provide support for a predictable appropriate period to facilitate artery healing, and subsequently, fail safely and be absorbed in a controllable manner. Biodegradable polymers are typically weaker than metals currently employed to construct stents, so it is difficult to ensure sufficient strength to keep the artery open and alleviate symptoms acutely while keeping other design parameters within clinically acceptable ranges. These design challenges are serious, given the general lack of understanding of biodegradable polymer behavior and evolution in intimal operating conditions. The modus operandi is mainly empirical and relies heavily on trial-and-error methodologies burdened by difficult, resource-expensive, and time-consuming experiments. We are striving for theoretical advancements systematizing the empirical knowledge into rational frameworks that could be cast into in silico tools for simulation and product development optimization. These challenges are evident when one considers that there are no biodegradable stents on the US market despite more than 30 years of development efforts (and currently only a couple with CE mark). This review summarizes previous efforts at implementing biodegradable stents, discusses the specific challenges involved, and presents recently developed material-modeling frameworks that can benefit this exciting field.

journal_name

Ann Biomed Eng

authors

Soares JS,Moore JE Jr

doi

10.1007/s10439-015-1477-2

subject

Has Abstract

pub_date

2016-02-01 00:00:00

pages

560-79

issue

2

eissn

0090-6964

issn

1573-9686

pii

10.1007/s10439-015-1477-2

journal_volume

44

pub_type

杂志文章
  • Adaptive neural network that subserves optimal homeostatic control of breathing.

    abstract::An adaptive neural network model that exhibits the optimality and homeostasis characteristics of the respiratory control system is described. Based upon the Hopfield network structure and a postulated Hebb-like respiratory synapse with correlational short-term potentiation, the model is capable of mimicking the normal...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02584332

    authors: Poon CS

    更新日期:1993-09-01 00:00:00

  • MEG connectivity analysis in patients with Alzheimer's disease using cross mutual information and spectral coherence.

    abstract::Alzheimer's disease (AD) is an irreversible brain disorder which represents the most common form of dementia in western countries. An early and accurate diagnosis of AD would enable to develop new strategies for managing the disease; however, nowadays there is no single test that can accurately predict the development...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-0155-7

    authors: Alonso JF,Poza J,Mañanas MA,Romero S,Fernández A,Hornero R

    更新日期:2011-01-01 00:00:00

  • Evaluation of stochastic differential equation approximation of ion channel gating models.

    abstract::Fox and Lu derived an algorithm based on stochastic differential equations for approximating the kinetics of ion channel gating that is simpler and faster than "exact" algorithms for simulating Markov process models of channel gating. However, the approximation may not be sufficiently accurate to predict statistics of...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-009-9635-z

    authors: Bruce IC

    更新日期:2009-04-01 00:00:00

  • Evaluation of human endothelial cells post stent deployment in a cardiovascular simulator in vitro.

    abstract::Percutaneous stent implantation has revolutionized the clinical treatment of occluded arteries. Nevertheless, there is still a large unmet need to prevent re-occlusion after implantation. Consequently, a niche exists for a cost-effective pre-clinical method of evaluating novel interventional devices in human models. T...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-009-9701-6

    authors: Punchard MA,O'Cearbhaill ED,Mackle JN,McHugh PE,Smith TJ,Stenson-Cox C,Barron V

    更新日期:2009-07-01 00:00:00

  • Inverse parameter fitting of biological tissues: a response surface approach.

    abstract::In this paper, we present the application of a semi-global inverse method for determining material parameters of biological tissues. The approach is based on the successive response surface method, and is illustrated by fitting constitutive parameters to two nonlinear anisotropic constitutive equations, one for aortic...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-005-8338-3

    authors: Einstein DR,Freed AD,Stander N,Fata B,Vesely I

    更新日期:2005-12-01 00:00:00

  • Simulating Developmental Cardiac Morphology in Virtual Reality Using a Deformable Image Registration Approach.

    abstract::While virtual reality (VR) has potential in enhancing cardiovascular diagnosis and treatment, prerequisite labor-intensive image segmentation remains an obstacle for seamlessly simulating 4-dimensional (4-D, 3-D + time) imaging data in an immersive, physiological VR environment. We applied deformable image registratio...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-018-02113-z

    authors: Abiri A,Ding Y,Abiri P,Packard RRS,Vedula V,Marsden A,Kuo CJ,Hsiai TK

    更新日期:2018-12-01 00:00:00

  • On the Compressibility of Arterial Tissue.

    abstract::Arterial tissue is commonly assumed to be incompressible. While this assumption is convenient for both experimentalists and theorists, the compressibility of arterial tissue has not been rigorously investigated. In the current study we present an experimental-computational methodology to determine the compressibility ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1417-1

    authors: Nolan DR,McGarry JP

    更新日期:2016-04-01 00:00:00

  • MUlti-Dimensional Spline-Based Estimator (MUSE) for motion estimation: algorithm development and initial results.

    abstract::Image registration and motion estimation play central roles in many fields, including RADAR, SONAR, light microscopy, and medical imaging. Because of its central significance, estimator accuracy, precision, and computational cost are of critical importance. We have previously presented a highly accurate, spline-based ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-008-9564-2

    authors: Viola F,Coe RL,Owen K,Guenther DA,Walker WF

    更新日期:2008-12-01 00:00:00

  • Rat aortic smooth muscle cells contract in response to serum and its components in a calcium independent manner.

    abstract::Diluted serum provides a model of interstitial fluid that can be used to study the response of smooth muscle cells (SMCs) to interstitial flow. The effect of serum and some of its components on SMC contraction (area reduction) and intracellular calcium ([Ca2+]i) response were characterized in rat aortic SMC in vitro. ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-004-7820-7

    authors: Ainslie K,Shi ZD,Garanich JS,Tarbell JM

    更新日期:2004-12-01 00:00:00

  • Polycrystalline silicon micromachining: a new technology for integrated sensors.

    abstract::Polycrystalline silicon (poly-Si) micromechanical structures can be made by selectively etching an underlying sacrificial oxide layer. Advantages of this micromachining technique are its simplicity and compatibility with conventional integrated-circuit processing. Compressive internal stress in poly-Si films constrain...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02584269

    authors: Howe RT

    更新日期:1986-01-01 00:00:00

  • Analysis of electrically induced reentrant circuits in a sheet of myocardium.

    abstract::Understanding the complex spatiotemporal dynamics of action potential propagation in the heart during arrhythmia is exceedingly difficult. This study applies nonlinear dynamics tools to simplify this task. Using the results of a simulation of an electrical induction of reentry in a sheet of myocardium represented as a...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1581289

    authors: Larson C,Dragnev L,Trayanova N

    更新日期:2003-07-01 00:00:00

  • The Impact of Fluid Inertia on In Vivo Estimation of Mitral Valve Leaflet Constitutive Properties and Mechanics.

    abstract::We examine the influence of the added mass effect (fluid inertia) on mitral valve leaflet stress during isovolumetric phases. To study this effect, oscillating flow is applied to a flexible membrane at various frequencies to control inertia. Resulting membrane strain is calculated through a three-dimensional reconstru...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1463-8

    authors: Bark DL Jr,Dasi LP

    更新日期:2016-05-01 00:00:00

  • A general framework for characterizing studies of brain interface technology.

    abstract::The development of brain interface (BI) technology continues to attract researchers with a wide range of backgrounds and expertise. Though the BI community is committed to accurate and objective evaluation of methods, systems, and technology, the very diversity of the methods and terminology used in the field hinders ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-005-7706-3

    authors: Mason SG,Jackson MM,Birch GE

    更新日期:2005-11-01 00:00:00

  • Quantitative Validation of a Human Body Finite Element Model Using Rigid Body Impacts.

    abstract::Validation is a critical step in finite element model (FEM) development. This study focuses on the validation of the Global Human Body Models Consortium full body average male occupant FEM in five localized loading regimes-a chest impact, a shoulder impact, a thoracoabdominal impact, an abdominal impact, and a pelvic ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1286-7

    authors: Vavalle NA,Davis ML,Stitzel JD,Gayzik FS

    更新日期:2015-09-01 00:00:00

  • Strength and electron features of irradiated bone.

    abstract::Radiation applied for therapy and diagnostics damages molecular/atomic couples of biotissues, bones being among them. As a result, electron peculiarities and mechanical behavior of the latter are altered. Correlation between strength of the irradiated bone and its electron features explored due to photo- and exoelectr...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1114/1.1424911

    authors: Dekhtyar Y

    更新日期:2001-12-01 00:00:00

  • The Effects of 4%Fe on the Performance of Pure Zinc as Biodegradable Implant Material.

    abstract::The efforts to develop structural materials for biodegradable metal implants have lately shifted their focus from Magnesium and Iron base alloys towards Zinc. This was mainly due to the accelerated corrosion rate of Mg that is accompanied by hydrogen gas evolution, formation of voluminous iron oxide products with redu...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-019-02245-w

    authors: Kafri A,Ovadia S,Yosafovich-Doitch G,Aghion E

    更新日期:2019-06-01 00:00:00

  • Models of flow-induced loading on blood cells in laminar and turbulent flow, with application to cardiovascular device flow.

    abstract::Viscous shear stress and Reynolds stress are often used to predict hemolysis and thrombosis due to flow-induced stress on blood elements in cardiovascular devices. These macroscopic stresses are distinct from the true stress on an individual cell, which is determined by the local microscale flow field. In this paper t...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-007-9308-8

    authors: Quinlan NJ,Dooley PN

    更新日期:2007-08-01 00:00:00

  • Effects of hydration and fixed charge density on fluid transport in charged hydrated soft tissues.

    abstract::The effects of tissue hydration and fixed charge density on hydraulic permeability and creep behavior of cartilaginous tissues have been investigated using the triphasic theory and finite element methods. The empirical model for hydraulic permeability of uncharged gels and Mackie and Meares (1955) model for ion diffus...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1615576

    authors: Gu WY,Yao H

    更新日期:2003-11-01 00:00:00

  • Through the microcirculatory maze with machete, molecule, and minicomputer (1986 Alza lecture).

    abstract::This is a personal historical essay on meanderings through the jungle of the microcirculatory swamp. Because one pretends that the wandering was purposefully exploratory, a few guideposts are placed at positions where one could discern blaze-marks from earlier wanderers, and the path cut a little wider along some of t...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/BF02363568

    authors: Bassingthwaighte JB

    更新日期:1987-01-01 00:00:00

  • Parametric comparisons of intracranial mechanical responses from three validated finite element models of the human head.

    abstract::A number of human head finite element (FE) models have been developed from different research groups over the years to study the mechanisms of traumatic brain injury. These models can vary substantially in model features and parameters, making it important to evaluate whether simulation results from one model are read...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-013-0907-2

    authors: Ji S,Ghadyani H,Bolander RP,Beckwith JG,Ford JC,McAllister TW,Flashman LA,Paulsen KD,Ernstrom K,Jain S,Raman R,Zhang L,Greenwald RM

    更新日期:2014-01-01 00:00:00

  • Computational approach to estimating the effects of blood properties on changes in intra-stent flow.

    abstract::In this study various blood rheological assumptions are numerically investigated for the hemodynamic properties of intra-stent flow. Non-newtonian blood properties have never been implemented in blood coronary stented flow investigation, although its effects appear essential for a correct estimation and distribution o...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-006-9123-7

    authors: Benard N,Perrault R,Coisne D

    更新日期:2006-08-01 00:00:00

  • Motile Dendritic Cells Sense and Respond to Substrate Geometry.

    abstract::Dendritic cell (DC) migration is required for efficient presentation of antigen to T cells and the initiation of an adaptive immune response. In spite of its importance, many aspects of DC migration have not been characterized. DCs encounter a variety of environments with different stiffness and geometry, but the effe...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-018-2041-7

    authors: Bendell AC,Anderson N,Blumenthal D,Williamson EK,Chen CS,Burkhardt JK,Hammer DA

    更新日期:2018-09-01 00:00:00

  • Interstitial stress and fluid pressure within a growing tumor.

    abstract::A solid tumor is composed of a population of cells that is expanding as a result of cell division. With dense cell packing, the solid matrix of the interstitial tissue is subject to residual stress. In addition, elevated interstitial fluid pressure (IFP) has been reported by researchers for a number of solid tumors. T...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1554923

    authors: Sarntinoranont M,Rooney F,Ferrari M

    更新日期:2003-03-01 00:00:00

  • Development of an endothelial-smooth muscle cell coculture model using phenotype-controlled smooth muscle cells.

    abstract::A coculture of endothelial cells (ECs) and smooth muscle cells (SMCs), which mimics cellular interactions appearing in vivo, has been performed in studies on the relationship between atherogenesis and fluid shear stress conditions. Although healthy arteries in vivo consist of contractile phenotype SMCs, cultured cells...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-011-0372-8

    authors: Sakamoto N,Kiuchi T,Sato M

    更新日期:2011-11-01 00:00:00

  • Conductance method for the measurement of cross-sectional areas of the aorta.

    abstract::A modified conductance method to determine the cross-sectional areas (CSAs) of arteries in piglets was evaluated in vivo. The method utilized a conductance catheter having four electrodes. Between the outer electrodes an alternating current was applied and between the inner electrodes the induced voltage difference wa...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.219

    authors: Kornet L,Jansen JR,Gussenhoven EJ,Hardeman MR,Hoeks AP,Versprille A

    更新日期:1999-03-01 00:00:00

  • Passive-dynamic ankle-foot orthoses substitute for ankle strength while causing adaptive gait strategies: a feasibility study.

    abstract::Bending stiffness of passive-dynamic ankle-foot orthoses (PD-AFOs) is a functional characteristic thought to restore lost ankle function due to weakened plantar flexors. However, lower extremity impairment profiles of patients are seldom limited to plantar flexion weakness, and PD-AFO characteristics often influence g...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-014-1067-8

    authors: Arch ES,Stanhope SJ

    更新日期:2015-02-01 00:00:00

  • Vascular remodeling in autogenous arterio-venous fistulas by MRI and CFD.

    abstract::Hemodynamic parameters play an important role in regulating vascular remodeling in arterio-venous fistula (AVF) maturation. Investigating the changes in hemodynamic parameters during AVF maturation is expected to improve our understanding of fistula failure, but very little data on actual temporal changes in human AVF...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-012-0703-4

    authors: Sigovan M,Rayz V,Gasper W,Alley HF,Owens CD,Saloner D

    更新日期:2013-04-01 00:00:00

  • Are DXA/aBMD and QCT/FEA Stiffness and Strength Estimates Sensitive to Sex and Age?

    abstract::Dual X-ray absorptiometry (DXA) measures areal bone mineral density (aBMD) by simplifying a complex 3D bone structure to a 2D projection and is not equally effective for explaining fracture strength in women and men. Unlike DXA, subject-specific quantitative computed tomography-based finite element analysis (QCT/FEA) ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-017-1914-5

    authors: Rezaei A,Giambini H,Rossman T,Carlson KD,Yaszemski MJ,Lu L,Dragomir-Daescu D

    更新日期:2017-12-01 00:00:00

  • Stereolithography 3D Bioprinting Method for Fabrication of Human Corneal Stroma Equivalent.

    abstract::3D bioprinting technology is a promising approach for corneal stromal tissue regeneration. In this study, gelatin methacrylate (GelMA) mixed with corneal stromal cells was used as a bioink. The visible light-based stereolithography (SLA) 3D bioprinting method was utilized to print the anatomically similar dome-shaped ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02537-6

    authors: Mahdavi SS,Abdekhodaie MJ,Kumar H,Mashayekhan S,Baradaran-Rafii A,Kim K

    更新日期:2020-07-01 00:00:00

  • Customised Selection of the Haptic Design in C-Loop Intraocular Lenses Based on Deep Learning.

    abstract::In order to increase the probability of having a successful cataract post-surgery, the customisation of the haptic design of the intraocular lens (IOL) according to the characteristics of the patient is recommended. In this study, we present two prediction models based on deep neural networks (DNNs). One is capable of...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02636-4

    authors: Cabeza-Gil I,Ríos-Ruiz I,Calvo B

    更新日期:2020-12-01 00:00:00