The Effects of 4%Fe on the Performance of Pure Zinc as Biodegradable Implant Material.

Abstract:

:The efforts to develop structural materials for biodegradable metal implants have lately shifted their focus from Magnesium and Iron base alloys towards Zinc. This was mainly due to the accelerated corrosion rate of Mg that is accompanied by hydrogen gas evolution, formation of voluminous iron oxide products with reduced degradation rate in the case of Iron implants and the crucial role of Zn in many physiological processes. However the mechanical properties and degradation capabilities of pure zinc in physiological environment are limited and do not comply with the requirements of biodegradable implants. The present study aims at evaluating the effect of 4%Fe on the in-vitro and in-vivo behavior of pure Zinc. This was carried out in order to address the inherent disadvantages of pure zinc in terms of mechanical properties and biodegradability. The results obtained clearly indicate that the biocompatibility and mechanical properties of the new material system was in accord with the prospective requirements of biodegradable implants. However the corrosion degradation of the new alloy in in-vivo conditions was quite similar to that of pure zinc in spite of the significant micro-galvanic effect created by Delta phase Zn11Fe.

journal_name

Ann Biomed Eng

authors

Kafri A,Ovadia S,Yosafovich-Doitch G,Aghion E

doi

10.1007/s10439-019-02245-w

subject

Has Abstract

pub_date

2019-06-01 00:00:00

pages

1400-1408

issue

6

eissn

0090-6964

issn

1573-9686

pii

10.1007/s10439-019-02245-w

journal_volume

47

pub_type

杂志文章
  • Automatized Patient-Specific Methodology for Numerical Determination of Biomechanical Corneal Response.

    abstract::This work presents a novel methodology for building a three-dimensional patient-specific eyeball model suitable for performing a fully automatic finite element (FE) analysis of the corneal biomechanics. The reconstruction algorithm fits and smooths the patient's corneal surfaces obtained in clinic with corneal topogra...

    journal_title:Annals of biomedical engineering

    pub_type: 临床试验,杂志文章

    doi:10.1007/s10439-015-1426-0

    authors: Ariza-Gracia MÁ,Zurita J,Piñero DP,Calvo B,Rodríguez-Matas JF

    更新日期:2016-05-01 00:00:00

  • Errors caused by combination of Di-4 ANEPPS and Fluo3/4 for simultaneous measurements of transmembrane potentials and intracellular calcium.

    abstract::Intracellular calcium concentration and transmembrane potentials are two important measurements used to study the mechanisms of cardiac activity. Fluorescent dyes have been used to measure these separately but not simultaneously in cardiac tissue. Fluo-3 and Fluo-4 (a recently improved version of Fluo-3) have been use...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.198

    authors: Johnson PL,Smith W,Baynham TC,Knisley SB

    更新日期:1999-07-01 00:00:00

  • Investigating the influence of haemodynamic stimuli on intracranial aneurysm inception.

    abstract::We propose a novel method to reconstruct the hypothetical geometry of the healthy vasculature prior to intracranial aneurysm (IA) formation: a Frenet frame is calculated along the skeletonization of the arterial geometry; upstream and downstream boundaries of the aneurysmal segment are expressed in terms of the local ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-013-0794-6

    authors: Chen H,Selimovic A,Thompson H,Chiarini A,Penrose J,Ventikos Y,Watton PN

    更新日期:2013-07-01 00:00:00

  • Micro-flow visualization of red blood cell-enhanced platelet concentration at sudden expansion.

    abstract::Microscopic steps and crevices are inevitable features within prosthetic blood-contacting devices. This study aimed to elucidate the thrombogenicity of the associated microscopic flow features by studying the transport of fluorescent platelet-sized particles in a suspension of red blood cells (RBCs) flowing through a ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-008-9494-z

    authors: Zhao R,Marhefka JN,Shu F,Hund SJ,Kameneva MV,Antaki JF

    更新日期:2008-07-01 00:00:00

  • In vitro, time-resolved PIV comparison of the effect of stent design on wall shear stress.

    abstract::The effect of stent design on wall shear stress (WSS) and oscillatory shear index (OSI) was studied in vitro using time-resolved digital particle image velocimetry (DPIV). Four drug-eluting stents [XIENCE V (Abbott Vascular), TAXUS Liberté (Boston Scientific), Endeavor (Medtronic), and Cypher (J&J Cordis)] and a bare-...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-009-9697-y

    authors: Charonko J,Karri S,Schmieg J,Prabhu S,Vlachos P

    更新日期:2009-07-01 00:00:00

  • Evaluation of three animal models for concussion and serious brain injury.

    abstract::Three animal models were evaluated in this study involving head impacts of the rat, including the Marmarou drop-weight and two momentum-exchange techniques. In series 1, 36 Wistar rats were hit on the side of the free-moving head using Marmarou's 450 g impact mass at 4.4, 5.4, and 6.3 m/s. Head acceleration was measur...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-011-0386-2

    authors: Viano DC,Hamberger A,Bolouri H,Säljö A

    更新日期:2012-01-01 00:00:00

  • Probabilistic evaluation of predicted force sensitivity to muscle attachment and glenohumeral stability uncertainty.

    abstract::A major benefit of computational modeling in biomechanics research is its ability to estimate internal muscular demands given limited input information. However, several assumptions regarding model parameters and constraints may influence model outputs. This research evaluated the influence of model parameter variabil...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-014-1035-3

    authors: Chopp-Hurley JN,Langenderfer JE,Dickerson CR

    更新日期:2014-09-01 00:00:00

  • The effect of ultrasonic frequency upon enhanced killing of P. aeruginosa biofilms.

    abstract::It is widely recognized that the bacteria sequestered in a biofilm on a medical implant are much more resistant to antibiotics than their planktonic counterparts. Recent studies have shown that application of antibiotic along with low power ultrasound significantly increases the killing of planktonic bacteria by the a...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02738539

    authors: Qian Z,Sagers RD,Pitt WG

    更新日期:1997-01-01 00:00:00

  • A reaction-diffusion model of basic fibroblast growth factor interactions with cell surface receptors.

    abstract::Basic fibroblast growth factor (FGF-2) is a potent angiogenic growth factor involved in the development of diseases such as cancer, atherosclerosis, and heart and limb ischemia, as well as normal wound healing and tissue development. Despite being one of the most heavily studied angiogenic growth factors, the binding ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1023/b:abme.0000030231.88326.78

    authors: Filion RJ,Popel AS

    更新日期:2004-05-01 00:00:00

  • Effect of cell-cell interactions on the observable strength of adhesion of sheets of cells.

    abstract::Previous research in cellular adhesion has focused primarily on studying isolated cells under conditions where cells do not interact with each other. However, in vivo cells form sheets where both cell-substratum and cell-cell interactions contribute to the overall adhesive behavior. Our understanding of how cell-cell ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.178

    authors: Peel MM,DiMilla PA

    更新日期:1999-03-01 00:00:00

  • 3D Printing of Calcium Phosphate Ceramics for Bone Tissue Engineering and Drug Delivery.

    abstract::Additive manufacturing, also known as 3D printing, has emerged over the past 3 decades as a disruptive technology for rapid prototyping and manufacturing. Vat polymerization, powder bed fusion, material extrusion, and binder jetting are distinct technologies of additive manufacturing, which have been used in a wide va...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/s10439-016-1678-3

    authors: Trombetta R,Inzana JA,Schwarz EM,Kates SL,Awad HA

    更新日期:2017-01-01 00:00:00

  • Gaussian pulse decomposition: an intuitive model of electrocardiogram waveforms.

    abstract::This study presents a novel approach to modeling the electrocardiogram (ECG): the Gaussian pulse decomposition. Constituent waves of the ECG are decomposed into and represented by Gaussian pulses using an iterative algorithm: the chip away decomposition (ChAD) algorithm. At each iteration, a nonlinear minimization met...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02648039

    authors: Suppappola S,Sun Y,Chiaramida SA

    更新日期:1997-03-01 00:00:00

  • Effects of External and Internal Hyperthermia on LDL Transport and Accumulation Within an Arterial Wall in the Presence of a Stenosis.

    abstract::Effects of hyperthermia on transport of low-density lipoprotein (LDL) through a stenosed arterial wall are analyzed comprehensively in the present work. The realistic and pertinent aspects of an arterial wall is represented by a multi-layer model, with a proper representation of the thickened intima region due to the ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-014-1196-0

    authors: Iasiello M,Vafai K,Andreozzi A,Bianco N,Tavakkoli F

    更新日期:2015-07-01 00:00:00

  • Comparison of respiratory rates derived from heart rate variability, ECG amplitude, and nasal/oral airflow.

    abstract::It would often be desirable to obtain the respiratory rate during everyday conditions without obtaining an additional respiratory trace. This study investigates the agreement between respiratory rate assessed from the electrocardiogram (ECG) and the reference respiratory rate derived from a nasal/oral airflow (AF). Na...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-008-9580-2

    authors: Cysarz D,Zerm R,Bettermann H,Frühwirth M,Moser M,Kröz M

    更新日期:2008-12-01 00:00:00

  • Impedances of thin and layered systems: cells with even or odd numbers of interfaces.

    abstract::Impedance data, e.g., system responses, from perturbing small amplitude applied sinusoid signals of near DC to high kilohertz frequencies, give chemical information. Analysis of frequency-dependent imaginary and real impedance proceeds from equivalent analog circuit elements to chemical and physical significance deter...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02368537

    authors: Buck RP

    更新日期:1992-01-01 00:00:00

  • Simulating Developmental Cardiac Morphology in Virtual Reality Using a Deformable Image Registration Approach.

    abstract::While virtual reality (VR) has potential in enhancing cardiovascular diagnosis and treatment, prerequisite labor-intensive image segmentation remains an obstacle for seamlessly simulating 4-dimensional (4-D, 3-D + time) imaging data in an immersive, physiological VR environment. We applied deformable image registratio...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-018-02113-z

    authors: Abiri A,Ding Y,Abiri P,Packard RRS,Vedula V,Marsden A,Kuo CJ,Hsiai TK

    更新日期:2018-12-01 00:00:00

  • On the Impact of Intraluminal Thrombus Mechanical Behavior in AAA Passive Mechanics.

    abstract::Intraluminal thrombus (ILT) is a pseudo-tissue that develops from coagulated blood, and is found in most abdominal aortic aneurysms (AAAs) of clinically relevant size. A number of studies have suggested that ILT mechanical characteristics may be related to AAA risk of rupture, even though there is still great controve...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1267-x

    authors: Riveros F,Martufi G,Gasser TC,Rodriguez-Matas JF

    更新日期:2015-09-01 00:00:00

  • Two methods for recommending bat weights.

    abstract::Baseball players swung very light and very heavy bats through our instrument and the speed of the bat was recorded. These data were used to make mathematical models for each person. Then these models were coupled with equations of physics for bat-ball collisions to compute the Ideal Bat Weight for each individual. How...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02584443

    authors: Bahill AT,Freitas MM

    更新日期:1995-07-01 00:00:00

  • A single equivalent moving dipole model: an efficient approach for localizing sites of origin of ventricular electrical activation.

    abstract::We propose a new method for guiding catheter ablation procedures to abolish sites of origin of arrhythmias. This method models both cardiac electrical activity and current pulses delivered from the tip of the ablation catheter with a single equivalent moving dipole (SEMD). The SEMD parameters are obtained from analysi...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1567281

    authors: Armoundas AA,Feldman AB,Mukkamala R,Cohen RJ

    更新日期:2003-05-01 00:00:00

  • Quantification of rigidity in Parkinson's disease.

    abstract::In this paper, a new method for quantification of rigidity in elbow joint of Parkinsonian patients is introduced. One of the most known syndromes in Parkinson's disease (PD) is increased passive stiffness in muscles, which leads to rigidity in joints. Clinical evaluation of stiffness in wrist and/or elbow, commonly us...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-007-9379-6

    authors: Sepehri B,Esteki A,Ebrahimi-Takamjani E,Shahidi GA,Khamseh F,Moinodin M

    更新日期:2007-12-01 00:00:00

  • An artificial neural network approach to the predictive modeling of tensile force during renal suturing.

    abstract::Further understanding of the mechanical deformation and tear behavior of kidney during suturing helps to enhance surgical task execution that requires fine suture manipulation. This paper aims to develop a model to describe the relationship between the tensile force acting on suture line and the resulted kidney deform...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-012-0722-1

    authors: Yu D,Qing Y,Jianxun Z,Jun D

    更新日期:2013-04-01 00:00:00

  • An inverse approach to determine solute and solvent permeability parameters in artificial tissues.

    abstract::This study presents a generic numerical model to simulate the coupled solute and solvent transport in tissue sections during addition and removal of chemical additives or cryoprotective agents (CPA; dimethylsulfoxide or DMSO). Osmotic responses of various tissue cells within the artificial tissue are predicted by the ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-005-1511-x

    authors: He Y,Devireddy RV

    更新日期:2005-05-01 00:00:00

  • Influence of autoregressive model parameter uncertainty on spectral estimates of heart rate dynamics.

    abstract::Linear autoregressive (AR) model-based heart rate (HR) spectral analysis has been widely used to study HR dynamics. Owing to system and measurement noise, the parameters of an AR model have intrinsic statistical uncertainty. In this study, we evaluate how this AR parameter uncertainty can translate to uncertainty in H...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02368320

    authors: Christini DJ,Kulkarni A,Rao S,Stutman ER,Bennett FM,Hausdorff JM,Oriol N,Lutchen KR

    更新日期:1995-03-01 00:00:00

  • Stochasticity in membrane-localized "ligand-receptor-G protein" binding: consequences for leukocyte movement behavior.

    abstract::The signal that governs the chemotactic response of mammalian white blood cells and tissue cells arises from membrane-localized binding events involving chemotactic factor ligands and receptors and G proteins. Fluctuations in this signal have been traditionally attributed to significant "noise" in receptor-ligand bind...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02584427

    authors: Moghe PV,Tranquillo RT

    更新日期:1995-05-01 00:00:00

  • Tauberian-prony feature extraction technique for esophageal motility patterns.

    abstract::For the esophageal contractile activity recorded during swallowing, a feature extraction scheme has been developed. It recognizes the time, duration, and amplitudes of local peaks for each peristaltic wave. The method is based on the Tauberian approximation for modeling waveforms as a sum of identically shaped pulses ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02367607

    authors: Abou-Chadi FE,Ezzat FA,Gad-Elhak N,Sif el-Din AA

    更新日期:1993-03-01 00:00:00

  • Noninvasive recovery of acinar anatomic information from CO2 expirograms.

    abstract::A numerical single path model of respiratory gas exchange with distributed alveolar gas sources was used to estimate the anatomical changes in small peripheral airways such as occur in chronic obstructive pulmonary diseases (COPD). A previous sensitivity analysis of the single path model showed that decreasing total a...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02368236

    authors: Schwardt JD,Neufeld GR,Baumgardner JE,Scherer PW

    更新日期:1994-05-01 00:00:00

  • Modeling soluble gas exchange in the airways and alveoli.

    abstract::A mathematical model of heat, water and soluble gas exchange in the airways and alveoli was used to predict the location of soluble gas exchange in the lung. A previously published model of heat, water and soluble gas exchange in the airways was improved by incorporating anatomical data on the airway wall to better de...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1630600

    authors: Anderson JC,Babb AL,Hlastala MP

    更新日期:2003-12-01 00:00:00

  • Therapeutic effects of functional electrical stimulation on gait in individuals post-stroke.

    abstract::Functional electrical stimulation (FES) to lower extremity (LE) muscles is used by individuals post-stroke as an alternative to mechanical orthotic devices during gait or as a training modality during rehabilitation. Technological developments which improve the feasibility, accessibility and effectiveness of FES syste...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/s10439-014-1148-8

    authors: Kafri M,Laufer Y

    更新日期:2015-02-01 00:00:00

  • A regional blood flow model for β2-microglobulin kinetics and for simulating intra-dialytic exercise effect.

    abstract::A kinetic model based on first principles, for β(2)-microglobulin, is presented to obtain precise parameter estimates for individual patient. To reduce the model complexity, the number of model parameters was reduced using a priori identifiability analysis. The model validity was confirmed with the clinical data of te...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-011-0383-5

    authors: Maheshwari V,Samavedham L,Rangaiah GP

    更新日期:2011-12-01 00:00:00

  • Rapid platelet accumulation leading to thrombotic occlusion.

    abstract::Platelet thrombosis under arterial conditions remains a large clinical problem. Previous in vitro experiments have concentrated on early adherence without thrombotic occlusion. We have developed a controllable hemodynamic system that creates intravascular thrombosis to occlusion. Lightly heparinized (3.5 USP units/mL)...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-011-0296-3

    authors: Para A,Bark D,Lin A,Ku D

    更新日期:2011-07-01 00:00:00