A regional blood flow model for β2-microglobulin kinetics and for simulating intra-dialytic exercise effect.

Abstract:

:A kinetic model based on first principles, for β(2)-microglobulin, is presented to obtain precise parameter estimates for individual patient. To reduce the model complexity, the number of model parameters was reduced using a priori identifiability analysis. The model validity was confirmed with the clinical data of ten renal patients on post-dilution hemodiafiltration. The model fit resulted in toxin distribution volume (V(d)) of 14.22 ± 0.75 L, plasma fraction in extracellular compartment (f(P)) of 0.39 ± 0.03, and inter-compartmental clearance of 44 ± 4.1 mL min(-1). Parameter estimates suggest that V(d) and f(P) are much higher in hemodialysis patients than in normal subjects. The developed model predicts larger removed toxin mass than that predicted by the two-pool model. On the application front, the developed model was employed to explain the effect of intra-dialytic exercise on toxin removal. The presented simulations suggest that intra-dialytic exercise not only increases the blood flow to low flow region, but also decreases the inter-compartmental resistance. Combined, they lead to increased toxin removal during dialysis and reduced post-dialysis rebound. The developed model can assist in suggesting the improved dialysis dose based on β(2)-microglobulin, and also lead to quantitative inclusion of intra-dialytic exercise in the future.

journal_name

Ann Biomed Eng

authors

Maheshwari V,Samavedham L,Rangaiah GP

doi

10.1007/s10439-011-0383-5

subject

Has Abstract

pub_date

2011-12-01 00:00:00

pages

2879-90

issue

12

eissn

0090-6964

issn

1573-9686

journal_volume

39

pub_type

杂志文章
  • Generalized sensitivity functions in physiological system identification.

    abstract::Parameters of physiological models are commonly associated in an input-output experiment with a specific pattern of the system response. This association is often made on an intuitive basis by traditional sensitivity analysis, i.e., by inspecting the variations of model output trajectories with respect to parameter va...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.207

    authors: Thomaseth K,Cobelli C

    更新日期:1999-09-01 00:00:00

  • Micro-computed tomography based computational fluid dynamics for the determination of shear stresses in scaffolds within a perfusion bioreactor.

    abstract::Perfusion bioreactors are known to exert shear stresses on cultured cells, leading to cell differentiation and enhanced extracellular matrix deposition on scaffolds. The influence of the scaffold's porous microstructure is investigated for a polycaprolactone (PCL) scaffold with a regular microarchitecture and a silk f...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-014-0981-0

    authors: Zermatten E,Vetsch JR,Ruffoni D,Hofmann S,Müller R,Steinfeld A

    更新日期:2014-05-01 00:00:00

  • Evaluation of stochastic differential equation approximation of ion channel gating models.

    abstract::Fox and Lu derived an algorithm based on stochastic differential equations for approximating the kinetics of ion channel gating that is simpler and faster than "exact" algorithms for simulating Markov process models of channel gating. However, the approximation may not be sufficiently accurate to predict statistics of...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-009-9635-z

    authors: Bruce IC

    更新日期:2009-04-01 00:00:00

  • Effects of crowding on the thermal stability of heterogeneous protein solutions.

    abstract::Crowding can substantially affect the transition of a protein between its native (N) and unfolded (U) states via volume exclusion effects. Also, it influences considerably the aggregation (A) of unfolded proteins. To examine the details, we developed an approach for computing the kinetic rates of the process N <--> U ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-005-5780-8

    authors: Despa F,Orgill DP,Lee RC

    更新日期:2005-08-01 00:00:00

  • Acoustic Emissions as a Non-invasive Biomarker of the Structural Health of the Knee.

    abstract::The longitudinal assessment of joint health is a long-standing issue in the management of musculoskeletal injuries. The acoustic emissions (AEs) produced by joint articulation could serve as a biomarker for joint health assessment, but their use has been limited by a lack of mechanistic understanding of their creation...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-019-02333-x

    authors: Whittingslow DC,Jeong HK,Ganti VG,Kirkpatrick NJ,Kogler GF,Inan OT

    更新日期:2020-01-01 00:00:00

  • A review of approaches to mobility telemonitoring of the elderly in their living environment.

    abstract::Rapid technological advances have prompted the development of a wide range of telemonitoring systems to enable the prevention, early diagnosis and management, of chronic conditions. Remote monitoring can reduce the amount of recurring admissions to hospital, facilitate more efficient clinical visits with objective res...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/s10439-005-9068-2

    authors: Ní Scanaill C,Carew S,Barralon P,Noury N,Lyons D,Lyons GM

    更新日期:2006-04-01 00:00:00

  • Modeling soluble gas exchange in the airways and alveoli.

    abstract::A mathematical model of heat, water and soluble gas exchange in the airways and alveoli was used to predict the location of soluble gas exchange in the lung. A previously published model of heat, water and soluble gas exchange in the airways was improved by incorporating anatomical data on the airway wall to better de...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1630600

    authors: Anderson JC,Babb AL,Hlastala MP

    更新日期:2003-12-01 00:00:00

  • Integration of clinical data collected at different times for virtual surgery in single ventricle patients: a case study.

    abstract::Newborns with single ventricle physiology are usually palliated with a multi-staged procedure. When cardiovascular complications e.g., collateral vessel formation occur during the inter-stage periods, further treatments are required. An 8-month-old patient, who underwent second stage (i.e., bi-directional Glenn, BDG) ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-014-1113-6

    authors: Corsini C,Baker C,Baretta A,Biglino G,Hlavacek AM,Hsia TY,Kung E,Marsden A,Migliavacca F,Vignon-Clementel I,Pennati G,Modeling of Congenital Hearts Alliance (MOCHA) Investigators.

    更新日期:2015-06-01 00:00:00

  • A new pulsatile flow visualization method using a photochromic dye with application to Doppler ultrasound.

    abstract::A nonintrusive method for the visualization of pulsatile flow velocity profiles is described. The method is based on the use of a photochromic dye that is added to the fluid being studied and a nitrogen laser which excites the dye producing a marker "line" whose movement can be photographed. A microcomputer is used as...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02584271

    authors: Poots K,Cobbold RS,Johnston KW,Appugliese R,Kassam M,Zuech PE,Hummel RL

    更新日期:1986-01-01 00:00:00

  • Body-worn sensor design: what do patients and clinicians want?

    abstract::User preferences need to be taken into account in order to be able to design devices that will gain acceptance both in a clinical and home setting. Sensor systems become redundant if patients or clinicians do not want to work with them. The aim of this systematic review was to determine both patients' and clinicians' ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/s10439-011-0339-9

    authors: Bergmann JH,McGregor AH

    更新日期:2011-09-01 00:00:00

  • Use of pseudorandom noise in studies of auditory evoked potentials.

    abstract::The extent to which sensorineural systems such as the auditory system are nonlinear depends on the type of stimulus that is used, and the part of the system from which recordings are made. An estimate of the first-order Wiener kernel of the evoked response from the inferior colliculus to amplitude-modulated tones and ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02367379

    authors: Møller AR,Angelo RM

    更新日期:1988-01-01 00:00:00

  • An in vitro evaluation of the impact of eccentric deployment on transcatheter aortic valve hemodynamics.

    abstract::Patients with aortic stenosis present with calcium deposits on the native aortic valve, which can result in non-concentric expansion of Transcatheter Aortic Valve Replacement (TAVR) stents. The objective of this study is to evaluate whether eccentric deployment of TAVRs lead to turbulent blood flow and blood cell dama...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-014-1008-6

    authors: Gunning PS,Saikrishnan N,McNamara LM,Yoganathan AP

    更新日期:2014-06-01 00:00:00

  • A Battery-Powered Ankle Exoskeleton Improves Gait Mechanics in a Feasibility Study of Individuals with Cerebral Palsy.

    abstract::Neuromuscular impairment associated with cerebral palsy (CP) often leads to life-long walking deficits. Our goal was to evaluate the ability of a novel untethered wearable ankle exoskeleton to reduce the severity of gait pathology from CP. In this clinical feasibility study of five individuals with CP, we used instrum...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-019-02237-w

    authors: Lerner ZF,Harvey TA,Lawson JL

    更新日期:2019-06-01 00:00:00

  • Computer modeling of red blood cell rheology in the microcirculation: a brief overview.

    abstract::One of the major functions of the cardiovascular system is to deliver blood to the microcirculation where exchange of mass and energy can take place. In the present article, we will provide an overview of the state-of-the-art computational methods for modeling of red blood cell (RBC) rheology and dynamics in the micro...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-005-8776-y

    authors: Cristini V,Kassab GS

    更新日期:2005-12-01 00:00:00

  • Reinforcement of Mono- and Bi-layer Poly(Ethylene Glycol) Hydrogels with a Fibrous Collagen Scaffold.

    abstract::Biomaterial-based tissue engineering strategies hold great promise for osteochondral tissue repair. Yet significant challenges remain in joining highly dissimilar materials to achieve a biomimetic, mechanically robust design for repairing interfaces between soft tissue and bone. This study sought to improve interfacia...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1337-0

    authors: Kinneberg KR,Nelson A,Stender ME,Aziz AH,Mozdzen LC,Harley BA,Bryant SJ,Ferguson VL

    更新日期:2015-11-01 00:00:00

  • Automatic Model Generation Framework for Computational Simulation of Cochlear Implantation.

    abstract::Recent developments in computational modeling of cochlear implantation are promising to study in silico the performance of the implant before surgery. However, creating a complete computational model of the patient's anatomy while including an external device geometry remains challenging. To address such a challenge, ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1541-y

    authors: Mangado N,Ceresa M,Duchateau N,Kjer HM,Vera S,Dejea Velardo H,Mistrik P,Paulsen RR,Fagertun J,Noailly J,Piella G,González Ballester MÁ

    更新日期:2016-08-01 00:00:00

  • Genetics of energetics: transcriptional responses in cardiac metabolism.

    abstract::Recent evidence suggests that energy substrate metabolism forms the link between gene expression and contractile function of the heart. This hypothesis draws on three seemingly unconnected observations, made in 1941 by three different investigators. The first gave rise to the concept of the dynamic nature of body cons...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1114/1.1312187

    authors: Taegtmeyer H

    更新日期:2000-08-01 00:00:00

  • Biomechanical properties of esophagus during systemic treatment with epidermal growth factor in rats.

    abstract::The epidermal growth factor (EGF) is a growth factor with effects on many cell types and tissue. Morphometric and passive biomechanical properties were studied in isolated segments of the esophagus in 22 EGF-treated rats and 12 control rats. The rats were divided into groups with EGF treatment for 2, 4, 7, and 14 days...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1575758

    authors: Zhao J,Yang J,Vinter-Jensen L,Zhuang F,Gregersen H

    更新日期:2003-06-01 00:00:00

  • Effects of hydration and fixed charge density on fluid transport in charged hydrated soft tissues.

    abstract::The effects of tissue hydration and fixed charge density on hydraulic permeability and creep behavior of cartilaginous tissues have been investigated using the triphasic theory and finite element methods. The empirical model for hydraulic permeability of uncharged gels and Mackie and Meares (1955) model for ion diffus...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1615576

    authors: Gu WY,Yao H

    更新日期:2003-11-01 00:00:00

  • Left ventricular external constraint: relationship between pericardial, pleural and esophageal pressures during positive end-expiratory pressure and volume loading in dogs.

    abstract::Left ventricular (LV) diastolic filling is limited by the constraining effects exerted by the pericardium (PE) and the lung/chest wall. The aim of the present study was to assess the validity of various estimates of external cardiac constraint, compared to pericardial surface pressure (Ppe) measured lateral to the LV ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02584288

    authors: Kingma I,Smiseth OA,Frais MA,Smith ER,Tyberg JV

    更新日期:1987-01-01 00:00:00

  • A Model to Study Articular Cartilage Mechanical and Biological Responses to Sliding Loads.

    abstract::In physiological conditions, joint function involves continuously moving contact areas over the tissue surface. Such moving contacts play an important role for the durability of the tissue. It is known that in pathological joints these motion paths and contact mechanics change. Nevertheless, limited information exists...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1543-9

    authors: Schätti OR,Gallo LM,Torzilli PA

    更新日期:2016-08-01 00:00:00

  • Finite element modeling of coupled diffusion with partitioning in transdermal drug delivery.

    abstract::The finite element method is employed to simulate two-dimensional (axisymmetric) drug diffusion from a finite drug reservoir into the skin. The numerical formulation is based on a general mathematical model for multicomponent nonlinear diffusion that takes into account the coupling effects between the different compon...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-005-5788-6

    authors: Rim JE,Pinsky PM,van Osdol WW

    更新日期:2005-10-01 00:00:00

  • Lensfree optofluidic microscopy and tomography.

    abstract::Microfluidic devices aim at miniaturizing, automating, and lowering the cost of chemical and biological sample manipulation and detection, hence creating new opportunities for lab-on-a-chip platforms. Recently, optofluidic devices have also emerged where optics is used to enhance the functionality and the performance ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/s10439-011-0385-3

    authors: Bishara W,Isikman SO,Ozcan A

    更新日期:2012-02-01 00:00:00

  • The effect of strain rate on the viscoelastic response of aortic valve tissue: a direct-fit approach.

    abstract::Knowledge of strain-rate sensitivity of soft tissue viscoelastic and nonlinear elastic properties is important for accurate predictions of biomechanical behavior and for quantitative assessment of the effects of disease or surgical/pharmaceutical intervention. Soft tissues are known to exhibit mild rate sensitivity, b...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1023/b:abme.0000012742.01261.b0

    authors: Doehring TC,Carew EO,Vesely I

    更新日期:2004-02-01 00:00:00

  • An Engineered Biomimetic MPER Peptide Vaccine Induces Weakly HIV Neutralizing Antibodies in Mice.

    abstract::A vaccine that induces broadly neutralizing antibodies (bnAbs) against the human immunodeficiency virus (HIV) would be instrumental in controlling the disease. The membrane proximal external region (MPER) peptide is an appealing antigen candidate since it is conserved and is the target of several human bnAbs, such as ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-019-02398-8

    authors: Shao S,Huang WC,Lin C,Hicar MD,LaBranche CC,Montefiori DC,Lovell JF

    更新日期:2020-07-01 00:00:00

  • Kinematic analysis of the human temporomandibular joint.

    abstract::A kinematic analysis of the temporomandibular joint (TMJ) is developed to determine the range of motion of the mandible during normal opening and during special motions required for arthroscopic surgery. The translation of the mandible is restricted by the constraint of the ligaments. By accounting for the maximum all...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02368648

    authors: Kang QS,Updike DP,Salathe EP

    更新日期:1993-11-01 00:00:00

  • Hemodynamic energy dissipation in the cardiovascular system: generalized theoretical analysis on disease states.

    abstract:BACKGROUND:We present a fundamental theoretical framework for analysis of energy dissipation in any component of the circulatory system and formulate the full energy budget for both venous and arterial circulations. New indices allowing disease-specific subject-to-subject comparisons and disease-to-disease hemodynamic ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-009-9650-0

    authors: Dasi LP,Pekkan K,de Zelicourt D,Sundareswaran KS,Krishnankutty R,Delnido PJ,Yoganathan AP

    更新日期:2009-04-01 00:00:00

  • Multidirectional pelvic floor muscle strength measurement.

    abstract::Pelvic floor muscle (PFM) strength measurement provides useful information for the study of pelvic floor dysfunctions. Vaginal digital palpation, intravaginal pressure measurements, and the use of a dynamometric speculum represent currently available clinical methods for evaluating PFM strength. However, none of these...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-009-9728-8

    authors: Saleme CS,Rocha DN,Del Vecchio S,Silva Filho AL,Pinotti M

    更新日期:2009-08-01 00:00:00

  • Design Considerations of a Fiber Optic Pressure Sensor Protective Housing for Intramuscular Pressure Measurements.

    abstract::Intramuscular pressure (IMP), defined as skeletal muscle interstitial fluid pressure, reflects changes in individual muscle tension and may provide crucial insight into musculoskeletal biomechanics and pathologies. IMP may be measured using fiber-optic fluid pressure sensors, provided the sensor is adequately anchored...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-016-1703-6

    authors: Go SA,Jensen ER,O'Connor SM,Evertz LQ,Morrow DA,Ward SR,Lieber RL,Kaufman KR

    更新日期:2017-03-01 00:00:00

  • Effects of chamber shape and fiber orientation on relations between fiber dynamics and chamber dynamics.

    abstract::The function of a chamber depends on its hydrodynamic properties: isometric pressures it can exert in the operating range of distensions, compliances in the operating range of distensions, and wall-displacement resistances in the operating range of distensions. Wall-displacement resistance is the departure of pressure...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02368017

    authors: Regen DM

    更新日期:1988-01-01 00:00:00