On the Impact of Intraluminal Thrombus Mechanical Behavior in AAA Passive Mechanics.

Abstract:

:Intraluminal thrombus (ILT) is a pseudo-tissue that develops from coagulated blood, and is found in most abdominal aortic aneurysms (AAAs) of clinically relevant size. A number of studies have suggested that ILT mechanical characteristics may be related to AAA risk of rupture, even though there is still great controversy in this regard. ILT is isotropic and inhomogeneous and may appear as a soft (single-layered) or stiff (multilayered fibrotic) tissue. This paper aims to investigate how ILT constitution and topology influence the magnitude and location of peak wall stress (PWS). In total 21 patient-specific AAAs (diameter 4.2-5.4 cm) were reconstructed from computer tomography images and biomechanically analyzed using state-of-the-art modeling assumptions. Results indicated that PWS correlated stronger with ILT volume (ρ = 0.44, p = 0.05) and minimum thickness of ILT layer (ρ = 0.73, p = 0.001) than with maximum AAA diameter (ρ = 0.05, p = 0.82). On average PWS was 20% (SD 12%) higher for FE models that used soft instead of stiff ILT models (p < 0.001). PWS location strongly correlated with sites of minimum ILT thickness in the section of maximum AAA diameter and was independent from ILT stiffness. In addition, ILT heterogeneity, i.e., the spatial composition of soft and stiff thrombus tissue, can considerably influence stress in the AAA wall. The present study is limited to identification of influential biomechanical factors, and how its findings translate to an AAA rupture risk assessment remains to be explored by clinical studies.

journal_name

Ann Biomed Eng

authors

Riveros F,Martufi G,Gasser TC,Rodriguez-Matas JF

doi

10.1007/s10439-015-1267-x

subject

Has Abstract

pub_date

2015-09-01 00:00:00

pages

2253-64

issue

9

eissn

0090-6964

issn

1573-9686

journal_volume

43

pub_type

杂志文章
  • The effect of blood flow on the material properties of bone.

    abstract::This project was undertaken to establish if the integral circulation had any effects upon the mechanical behavior of bone. The influence of blood flow in the rabbit tibia on the strain induced at the bone surface when under load was assessed. Recordings were taken from three adult and three immature New Zealand White ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02390377

    authors: McDonald F,Pitt Ford TR

    更新日期:1994-03-01 00:00:00

  • Superparamagnetic iron oxide is suitable to label tendon stem cells and track them in vivo with MR imaging.

    abstract::Tendon stem cells (TSCs) may be used to effectively repair or regenerate injured tendons. However, the fates of TSCs once implanted in vivo remain unclear. This study was aimed to determine the feasibility of labeling TSCs with super-paramagnetic iron oxide (SPIO) nano-particles to track TSCs in vivo using MRI. Rabbit...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-013-0802-x

    authors: Yang Y,Zhang J,Qian Y,Dong S,Huang H,Boada FE,Fu FH,Wang JH

    更新日期:2013-10-01 00:00:00

  • Finite Element Model of a Deformable American Football Helmet Under Impact.

    abstract::Despite the use of helmets in American football, brain injuries are still prevalent. To reduce the burden of these injuries, novel impact mitigation systems are needed. The Vicis Zero1 (VZ1) American football helmet is unique in its use of multi-directional buckling structures sandwiched between a deformable outer she...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02472-6

    authors: Giudice JS,Caudillo A,Mukherjee S,Kong K,Park G,Kent R,Panzer MB

    更新日期:2020-05-01 00:00:00

  • Flow perfusion culture of marrow stromal cells seeded on porous biphasic calcium phosphate ceramics.

    abstract::Calcium phosphate ceramics have been widely used for filling bone defects to aid in the regeneration of new bone tissue. Addition of osteogenic cells to porous ceramic scaffolds may accelerate the bone repair process. This study demonstrates the feasibility of culturing marrow stromal cells (MSCs) on porous biphasic c...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-005-5536-y

    authors: Holtorf HL,Sheffield TL,Ambrose CG,Jansen JA,Mikos AG

    更新日期:2005-09-01 00:00:00

  • A model for compound action potentials and currents in a nerve bundle. I: The forward calculation.

    abstract::We describe a model for the Compound Action Currents (CACs) and Compound Action Potentials (CAPs) produced by a peripheral nerve bundle in vitro. The Single Fiber Action Currents (SFACs) and the extracellular Single Fiber Action Potentials (SFAPs) are calculated using a generalized volume conduction model. Frequency-d...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02368460

    authors: Wijesinghe RS,Gielen FL,Wikswo JP Jr

    更新日期:1991-01-01 00:00:00

  • A mediated glucose biosensor incorporated with reverse iontophoresis function for noninvasive glucose monitoring.

    abstract::The objective of this study was to develop a ferrocene mediated glucose biosensor for reverse iontophoresis. An amperometric ferrocene mediated glucose biosensor based on a three electrodes planar configuration was constructed using screen printing technique. Different combinations of glucose oxidase and ferrocene loa...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-9918-4

    authors: Ching CT,Sun TP,Huang SH,Shieh HL,Chen CY

    更新日期:2010-04-01 00:00:00

  • In vitro, time-resolved PIV comparison of the effect of stent design on wall shear stress.

    abstract::The effect of stent design on wall shear stress (WSS) and oscillatory shear index (OSI) was studied in vitro using time-resolved digital particle image velocimetry (DPIV). Four drug-eluting stents [XIENCE V (Abbott Vascular), TAXUS Liberté (Boston Scientific), Endeavor (Medtronic), and Cypher (J&J Cordis)] and a bare-...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-009-9697-y

    authors: Charonko J,Karri S,Schmieg J,Prabhu S,Vlachos P

    更新日期:2009-07-01 00:00:00

  • Nonlinear dynamics of microvascular blood flow.

    abstract::Kiani et al. (Kiani, M. F., A. R. Pries, L. L. Hsu, I. H. Sarelius, and G. R. Cokelet, Am. J. Physics. 266: H1822-H1828, 1994) suggested that blood velocity, hematocrit, and nodal pressures can oscillate spontaneously in large microvascular networks in the absence of biological control. This paper presents a model of ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1306346

    authors: Carr RT,Lacoin M

    更新日期:2000-06-01 00:00:00

  • A Novel Approach to Utilize Icariin as Icariin-Derived ECM on Small Intestinal Submucosa Scaffold for Bone Repair.

    abstract::Icariin (Ic) has been demonstrated as a potent osteoinductive compound for bone tissue engineering. However, toxic side effects of the drug and poor biocompatibility of drug delivery systems (DDSs) still limit its application for bone repair in the clinic. To overcome these disadvantages and utilize the osteoinductivi...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-017-1900-y

    authors: Li M,Zhang C,Zhong Y,Zhao J

    更新日期:2017-11-01 00:00:00

  • A Model to Study Articular Cartilage Mechanical and Biological Responses to Sliding Loads.

    abstract::In physiological conditions, joint function involves continuously moving contact areas over the tissue surface. Such moving contacts play an important role for the durability of the tissue. It is known that in pathological joints these motion paths and contact mechanics change. Nevertheless, limited information exists...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1543-9

    authors: Schätti OR,Gallo LM,Torzilli PA

    更新日期:2016-08-01 00:00:00

  • Permeability analysis of neuroactive drugs through a dynamic microfluidic in vitro blood-brain barrier model.

    abstract::This paper presents the permeability analysis of neuroactive drugs and correlation with in vivo brain/plasma ratios in a dynamic microfluidic blood-brain barrier (BBB) model. Permeability of seven neuroactive drugs (Ethosuximide, Gabapentin, Sertraline, Sunitinib, Traxoprodil, Varenicline, PF-304014) and trans-endothe...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-014-1086-5

    authors: Booth R,Kim H

    更新日期:2014-12-01 00:00:00

  • Evaluation of stochastic differential equation approximation of ion channel gating models.

    abstract::Fox and Lu derived an algorithm based on stochastic differential equations for approximating the kinetics of ion channel gating that is simpler and faster than "exact" algorithms for simulating Markov process models of channel gating. However, the approximation may not be sufficiently accurate to predict statistics of...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-009-9635-z

    authors: Bruce IC

    更新日期:2009-04-01 00:00:00

  • Tracking of Drug Release and Material Fate for Naturally Derived Omega-3 Fatty Acid Biomaterials.

    abstract::In vitro and in vivo studies were conducted on omega-3 fatty acid-derived biomaterials to determine their utility as an implantable material for adhesion prevention following soft tissue hernia repair and as a means to allow for the local delivery of antimicrobial or antibiofilm agents. Naturally derived biomaterials ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1489-y

    authors: Faucher KM,Artzi N,Beck M,Beckerman R,Moodie G,Albergo T,Conroy S,Dale A,Corbeil S,Martakos P,Edelman ER

    更新日期:2016-03-01 00:00:00

  • Sustained Efficacy and Arterial Drug Retention by a Fast Drug Eluting Cross-Linked Fatty Acid Coronary Stent Coating.

    abstract::The long held assumption that sustained drug elution from stent coatings over weeks to months is imperative for clinical efficacy has limited the choice for stent coating materials. We developed and evaluated an omega-3 fatty acid (O3FA) based stent coating that is 85% absorbed and elutes 97% of its Sirolimus analog (...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1435-z

    authors: Artzi N,Tzafriri AR,Faucher KM,Moodie G,Albergo T,Conroy S,Corbeil S,Martakos P,Virmani R,Edelman ER

    更新日期:2016-02-01 00:00:00

  • Biased cell migration of fibroblasts exhibiting contact guidance in oriented collagen gels.

    abstract::We present here the first quantitative correlation for cell contact guidance in an oriented fibrillar network in terms of biased cell migration. The correlation is between the anisotropic cell diffusion parameter, DA = Dx/Dy, and the collagen gel birefringence, delta n, a measure of axially biased collagen fibril orie...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02368241

    authors: Dickinson RB,Guido S,Tranquillo RT

    更新日期:1994-07-01 00:00:00

  • Reinforcement of Mono- and Bi-layer Poly(Ethylene Glycol) Hydrogels with a Fibrous Collagen Scaffold.

    abstract::Biomaterial-based tissue engineering strategies hold great promise for osteochondral tissue repair. Yet significant challenges remain in joining highly dissimilar materials to achieve a biomimetic, mechanically robust design for repairing interfaces between soft tissue and bone. This study sought to improve interfacia...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1337-0

    authors: Kinneberg KR,Nelson A,Stender ME,Aziz AH,Mozdzen LC,Harley BA,Bryant SJ,Ferguson VL

    更新日期:2015-11-01 00:00:00

  • The role of sugars in dendritic cell trafficking.

    abstract::Dendritic cells (DCs) are crucial components of the immune response, strategically positioned as immune sentinels. Complex trafficking and accurate positioning of DCs are indispensable for both immunity and tolerance. This is particularly evident for their therapeutic application where an unmet clinical need exists fo...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/s10439-011-0448-5

    authors: Silva Z,Konstantopoulos K,Videira PA

    更新日期:2012-04-01 00:00:00

  • A new pulsatile flow visualization method using a photochromic dye with application to Doppler ultrasound.

    abstract::A nonintrusive method for the visualization of pulsatile flow velocity profiles is described. The method is based on the use of a photochromic dye that is added to the fluid being studied and a nitrogen laser which excites the dye producing a marker "line" whose movement can be photographed. A microcomputer is used as...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02584271

    authors: Poots K,Cobbold RS,Johnston KW,Appugliese R,Kassam M,Zuech PE,Hummel RL

    更新日期:1986-01-01 00:00:00

  • Body Anthropometry and Bone Strength Conjointly Determine the Risk of Hip Fracture in a Sideways Fall.

    abstract::We hypothesize that variations of body anthropometry, conjointly with the bone strength, determine the risk of hip fracture. To test the hypothesis, we compared, in a simulated sideways fall, the hip impact energy to the energy needed to fracture the femur. Ten femurs from elderly donors were tested using a novel drop...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02682-y

    authors: Palanca M,Perilli E,Martelli S

    更新日期:2020-11-12 00:00:00

  • Restoring Ovarian Endocrine Function with Encapsulated Ovarian Allograft in Immune Competent Mice.

    abstract::Premature ovarian insufficiency (POI) is a major complication of cytotoxic treatments due to extreme ovarian sensitivity to chemotherapy and radiation. In pediatric cancer patients modern therapy has improved the long-term survival to over 80% in the United States. However, these cancer survivors face long-term health...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-016-1780-6

    authors: David A,Day JR,Cichon AL,Lefferts A,Cascalho M,Shikanov A

    更新日期:2017-07-01 00:00:00

  • Assessment of daily-life reaching performance after stroke.

    abstract::For an optimal guidance of the rehabilitation therapy of stroke patients in an in-home setting, objective, and patient-specific performance assessment of arm movements is needed. In this study, metrics of hand movement relative to the pelvis and the sternum were estimated in 13 stroke subjects using a full body ambula...

    journal_title:Annals of biomedical engineering

    pub_type: 临床试验,杂志文章

    doi:10.1007/s10439-014-1198-y

    authors: van Meulen FB,Reenalda J,Buurke JH,Veltink PH

    更新日期:2015-02-01 00:00:00

  • Mathematical models of the spatial distribution of retinal oxygen tension and consumption, including changes upon illumination.

    abstract::To better understand oxygen utilization by the retina, a mathematical model of oxygen diffusion and consumption in the cat outer, avascular retina was developed by analyzing previously recorded profiles of oxygen tension (PO2) as a function of retinal depth. Simple diffusion modelling of the oxygen distribution throug...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02368415

    authors: Haugh LM,Linsenmeier RA,Goldstick TK

    更新日期:1990-01-01 00:00:00

  • How crouch gait can dynamically induce stiff-knee gait.

    abstract::Children with cerebral palsy frequently experience foot dragging and tripping during walking due to a lack of adequate knee flexion in swing (stiff-knee gait). Stiff-knee gait is often accompanied by an overly flexed knee during stance (crouch gait). Studies on stiff-knee gait have mostly focused on excessive knee mus...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-9952-2

    authors: van der Krogt MM,Bregman DJ,Wisse M,Doorenbosch CA,Harlaar J,Collins SH

    更新日期:2010-04-01 00:00:00

  • Segmentation and Pore Structure Estimation in SEM Images of Tissue Engineering Scaffolds Using Genetic Algorithm.

    abstract::A python computer package is developed to segment and analyze scanning electron microscope (SEM) images of scaffolds for bone tissue engineering. The method requires only a portion of an SEM image to be labeled and used for training. The algorithm is then able to detect the pore characteristics for other SEM images ac...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02638-2

    authors: Rouhollahi A,Ilegbusi O,Foroosh H

    更新日期:2020-10-15 00:00:00

  • Analysis and prediction of left ventricular performance under load changes during cardiac catheterization.

    abstract::The applicability of a computer model, which relates the transmural mechanical distribution in the left ventricle (LV) to its global function at different loading conditions, was evaluated in patients with normal to near normal LV function undergoing cardiac catheterization. Left ventriculography and measurements of a...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02364159

    authors: Abboud L,Beyar R,Battler A,Rat M,Cohen A,Sideman S

    更新日期:1990-01-01 00:00:00

  • Fluid shifts due to microgravity and their effects on bone: a review of current knowledge.

    abstract::Bone loss during long-term space flight is potentially a significant problem. Bone mineral density measurements show that bone is lost at a rate of about 1% per month from the lumbar spine, and 1.5% per month from the hip. Bone density changes are not uniform throughout the skeleton, and there is accumulating evidence...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/s10439-005-8967-6

    authors: McCarthy ID

    更新日期:2005-01-01 00:00:00

  • A physical model describing the mechanism for formation of gas microbubbles in patients with mitral mechanical heart valves.

    abstract::This study was aimed at developing a physical model, supported by experimental observations, to describe the formation and growth of microbubbles seen in patients with mitral mechanical heart valves (MHV). This phenomenon, often referred to as high intensity transient signals (HITS), appears as bright, intense, high-v...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.231

    authors: Rambod E,Beizaie M,Shusser M,Milo S,Gharib M

    更新日期:1999-11-01 00:00:00

  • Stochastic system identification of skin properties: linear and wiener static nonlinear methods.

    abstract::Wiener static nonlinear system identification was used to study the linear dynamics and static nonlinearities in the response of skin and underlying tissue under indentation in vivo. A device capable of measuring the dynamic mechanical properties of bulk skin tissue was developed and it incorporates a custom-built Lor...

    journal_title:Annals of biomedical engineering

    pub_type: 临床试验,杂志文章

    doi:10.1007/s10439-012-0580-x

    authors: Chen Y,Hunter IW

    更新日期:2012-10-01 00:00:00

  • The Role of Synthetic Extracellular Matrices in Endothelial Progenitor Cell Homing for Treatment of Vascular Disease.

    abstract::Poor vascular homeostasis drives many clinical disorders including diabetes, arthritis, atherosclerosis, and peripheral artery disease. Local tissue ischemia resultant of insufficient blood flow is a potent stimulus for recruitment of endothelial progenitor cells (EPCs). This mobilization and homing is a multi-step pr...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/s10439-015-1400-x

    authors: Williams PA,Silva EA

    更新日期:2015-10-01 00:00:00

  • Creep deformation of the human trunk in response to prolonged and repetitive flexion: measuring and modeling the effect of external moment and flexion rate.

    abstract::While viscoelastic responses of isolated trunk soft tissues have been characterized in earlier studies, the effects of external loading and flexion rate on these responses in the intact human trunk are largely unknown. Two experiments were conducted to measure trunk viscoelastic behaviors, one involving prolonged flex...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-013-0797-3

    authors: Toosizadeh N,Nussbaum MA

    更新日期:2013-06-01 00:00:00