Assessment of daily-life reaching performance after stroke.

Abstract:

:For an optimal guidance of the rehabilitation therapy of stroke patients in an in-home setting, objective, and patient-specific performance assessment of arm movements is needed. In this study, metrics of hand movement relative to the pelvis and the sternum were estimated in 13 stroke subjects using a full body ambulatory movement analysis system, including 17 inertial sensors integrated in a body-worn suit. Results were compared with the level of arm impairment evaluated with the upper extremity part of the Fugl-Meyer Assessment scale (uFMA). Metrics of arm movement performance of the affected side, including size of work area, maximum reaching distance and movement range in vertical direction, were evaluated during a simulated daily-life task. These metrics appeared to strongly correlate with uFMA scores. Using this body-worn sensor system, metrics of the performance of arm movements can easily be measured and evaluated while the subject is ambulating in a simulated daily-life setting. Suggested metrics can be used to objectively assess the performance of the arm movements over a longer period in a daily-life setting. Further development of the body-worn sensing system is needed before it can be unobtrusively used in a daily-life setting.

journal_name

Ann Biomed Eng

authors

van Meulen FB,Reenalda J,Buurke JH,Veltink PH

doi

10.1007/s10439-014-1198-y

subject

Has Abstract

pub_date

2015-02-01 00:00:00

pages

478-86

issue

2

eissn

0090-6964

issn

1573-9686

journal_volume

43

pub_type

临床试验,杂志文章
  • Emerging Brain Morphologies from Axonal Elongation.

    abstract::Understanding the characteristic morphology of our brain remains a challenging, yet important task in human evolution, developmental biology, and neurosciences. Mathematical modeling shapes our understanding of cortical folding and provides functional relations between cortical wavelength, thickness, and stiffness. Ye...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1312-9

    authors: Holland MA,Miller KE,Kuhl E

    更新日期:2015-07-01 00:00:00

  • Mechanical behavior of vascular smooth muscle in cylindrical segments of arteries in vitro.

    abstract::Vascular smooth muscle mechanics have been studied in vitro in cylindrical segments of dog carotid artery, human internal mammary artery, and human saphenous vein. Such cylindrical preparations maintain normal vessel geometry and also permit correlation of mechanical phenomena with transmural pressure. These studies s...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02363919

    authors: Dobrin PB

    更新日期:1984-01-01 00:00:00

  • A direct compression stimulator for articular cartilage and meniscal explants.

    abstract::This paper describes the development and use of a direct compression stimulator for culturing explants from the meniscus of the knee and articular cartilage. Following design and fabrication of the instrument along with its data acquisition system, the function of the machine was verified by both mechanical means and ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-006-9157-x

    authors: Aufderheide AC,Athanasiou KA

    更新日期:2006-09-01 00:00:00

  • Biomechanical Challenges to Polymeric Biodegradable Stents.

    abstract::Biodegradable implants have demonstrated clinical success in simple applications (e.g., absorbable sutures) and have shown great potential in many other areas of interventional medicine, such as localized drug delivery, engineered tissue scaffolding, and structural implants. For endovascular stenting and musculoskelet...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1477-2

    authors: Soares JS,Moore JE Jr

    更新日期:2016-02-01 00:00:00

  • Geodesic based registration of sensor data and anatomical surface image data.

    abstract::This paper presents two related methods for registering an image of an anatomical object with data from sensors arranged on the object. One method is described with reference to a test case involving a rectangular electrode plaque disposed on a heart surface, which is imaged with MRI. Data from the electrodes is fused...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-007-9350-6

    authors: Hopenfeld B,Ashikaga H,McVeigh ER

    更新日期:2007-10-01 00:00:00

  • Left-right asymmetry of visual evoked potentials in brain-damaged patients: a mathematical model and experimental results.

    abstract::The left-right asymmetry in the potential amplitude on the scalp was studied in poststroke patients by using flash visual evoked potential (VEP) and a numerical two-dimensional model of the head. The left-right asymmetry of the VEP was measured in three patients after thrombosis, in one after hemorrhage, and in one he...

    journal_title:Annals of biomedical engineering

    pub_type: 临床试验,杂志文章

    doi:10.1007/BF02770997

    authors: Abboud S,Bar L,Rosenfeld M,Ring H,Glass I

    更新日期:1996-01-01 00:00:00

  • Adhesion of microfabricated particles on vascular endothelium: a parametric analysis.

    abstract::"Smart" drug delivery systems should be selective and effective to ensure drug administration at the right time, at the right dosage, and anywhere in the body. Among the several administration routes and delivery systems that have been proposed, one of the most effective and promising is based on microfabricated parti...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1023/b:abme.0000030255.36748.d3

    authors: Decuzzi P,Lee S,Decuzzi M,Ferrari M

    更新日期:2004-06-01 00:00:00

  • Phonocardiographic signal analysis method using a modified hidden Markov model.

    abstract::Auscultation is an important diagnostic indicator for cardiovascular analysis. Heart sound classification and analysis play an important role in the auscultative diagnosis. This study uses a combination of Mel-frequency cepstral coefficient (MFCC) and hidden Markov model (HMM) to efficiently extract the features for p...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-006-9232-3

    authors: Wang P,Lim CS,Chauhan S,Foo JY,Anantharaman V

    更新日期:2007-03-01 00:00:00

  • A small angle light scattering device for planar connective tissue microstructural analysis.

    abstract::The planar fibrous connective tissues of the body are composed of a dense extracellular network of collagen and elastin fibers embedded in a ground matrix, and thus can be thought of as biocomposites. Thus, the quantification of fiber architecture is an important step in developing an understanding of the mechanics of...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02684845

    authors: Sacks MS,Smith DB,Hiester ED

    更新日期:1997-07-01 00:00:00

  • Finite element modeling of coupled diffusion with partitioning in transdermal drug delivery.

    abstract::The finite element method is employed to simulate two-dimensional (axisymmetric) drug diffusion from a finite drug reservoir into the skin. The numerical formulation is based on a general mathematical model for multicomponent nonlinear diffusion that takes into account the coupling effects between the different compon...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-005-5788-6

    authors: Rim JE,Pinsky PM,van Osdol WW

    更新日期:2005-10-01 00:00:00

  • Matrix Stiffness Modulates Mesenchymal Stem Cell Sensitivity to Geometric Asymmetry Signals.

    abstract::Human stem cells hold significant potential for the treatment of various diseases. However, their use as a therapy is hampered because of limited understanding of the mechanisms by which they respond to environmental stimuli. Efforts to understand extracellular biophysical cues have demonstrated the critical roles of ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-018-2008-8

    authors: Piroli ME,Jabbarzadeh E

    更新日期:2018-06-01 00:00:00

  • Potential of the genetic algorithm neural network in the assessment of gait patterns in ankle arthrodesis.

    abstract::The aim of this study was to develop an empirical model of parameter-based gait data, based on an artificial neural network and a genetic algorithm, for the assessment of patients after ankle arthrodesis. Ground reaction force vectors were measured by force platforms during level walking. Nine force parameters express...

    journal_title:Annals of biomedical engineering

    pub_type: 临床试验,杂志文章

    doi:10.1114/1.1342053

    authors: Wu WL,Su FC,Cheng YM,Chou YL

    更新日期:2001-01-01 00:00:00

  • Parametric comparisons of intracranial mechanical responses from three validated finite element models of the human head.

    abstract::A number of human head finite element (FE) models have been developed from different research groups over the years to study the mechanisms of traumatic brain injury. These models can vary substantially in model features and parameters, making it important to evaluate whether simulation results from one model are read...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-013-0907-2

    authors: Ji S,Ghadyani H,Bolander RP,Beckwith JG,Ford JC,McAllister TW,Flashman LA,Paulsen KD,Ernstrom K,Jain S,Raman R,Zhang L,Greenwald RM

    更新日期:2014-01-01 00:00:00

  • Tissue remodeling of rat pulmonary artery in hypoxic breathing. II. Course of change of mechanical properties.

    abstract::When cells and the matrix of a tissue remodel, the mechanical properties of the tissue do change. The mechanical properties are expressed by constitutive equations. In this article the remodeling of the constitutive equation of the pulmonary artery is studied. The remodeling was induced in a rat breathing a gas whose ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1380417

    authors: Huang W,Delgado-West D,Wu JT,Fung YC

    更新日期:2001-01-01 00:00:00

  • Development of gradient descent adaptive algorithms to remove common mode artifact for improvement of cardiovascular signal quality.

    abstract:BACKGROUND:Common-mode noise degrades cardiovascular signal quality and diminishes measurement accuracy. Filtering to remove noise components in the frequency domain often distorts the signal. METHOD:Two adaptive noise canceling (ANC) algorithms were tested to adjust weighted reference signals for optimal subtraction ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-007-9294-x

    authors: Ciaccio EJ,Micheli-Tzanakou E

    更新日期:2007-07-01 00:00:00

  • A Wearable Magnet-Based System to Assess Activity and Joint Flexion in Humans and Large Animals.

    abstract::Functional outcomes, such as joint flexion and gait, are important indicators of efficacy in musculoskeletal research. Current technologies that objectively assess these parameters, including visual tracking systems and force plates, are challenging to deploy in long-term translational and clinical studies. To that en...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-018-2105-8

    authors: Qu F,Stoeckl BD,Gebhard PM,Hullfish TJ,Baxter JR,Mauck RL

    更新日期:2018-12-01 00:00:00

  • The placement of skin surface markers for non-invasive measurement of scapular kinematics affects accuracy and reliability.

    abstract::Abnormal scapular movement is widely believed to be an important factor in clinical pathology of the shoulder joint complex. Validated non-invasive techniques for measuring scapular movement have been developed, but the effect of marker placement on accuracy is unknown. The objective of this study was to determine the...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-0185-1

    authors: Bourne DA,Choo AM,Regan WD,MacIntyre DL,Oxland TR

    更新日期:2011-02-01 00:00:00

  • Comparison of Laboratory and On-Field Performance of American Football Helmets.

    abstract::The relationship between laboratory and on-field performance of football helmets was assessed for 31 football helmet models selected from those worn by players in the 2015-2019 National Football League (NFL) seasons. Linear impactor tests were conducted with helmets placed on an instrumented Hybrid III head and neck a...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02627-5

    authors: Bailey AM,McMurry TL,Cormier JM,Funk JR,Crandall JR,Mack CD,Myers BS,Arbogast KB

    更新日期:2020-11-01 00:00:00

  • Customised Selection of the Haptic Design in C-Loop Intraocular Lenses Based on Deep Learning.

    abstract::In order to increase the probability of having a successful cataract post-surgery, the customisation of the haptic design of the intraocular lens (IOL) according to the characteristics of the patient is recommended. In this study, we present two prediction models based on deep neural networks (DNNs). One is capable of...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02636-4

    authors: Cabeza-Gil I,Ríos-Ruiz I,Calvo B

    更新日期:2020-12-01 00:00:00

  • Partitioning of cortical and deep cytoskeleton responses from transient magnetic bead twisting.

    abstract::We attempted to estimate in living adherent epithelial alveolar cells, the degree of structural and mechanical heterogeneity by considering two individualized cytoskeleton components, i.e., a submembranous "cortical" cytoskeleton and a "deep" cytoskeleton (CSK). F-actin structure characterizing each CSK component was ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1616932

    authors: Laurent VM,Fodil R,Cañadas P,Féréol S,Louis B,Planus E,Isabey D

    更新日期:2003-11-01 00:00:00

  • The effects of anisotropy on the stress analyses of patient-specific abdominal aortic aneurysms.

    abstract::The local dilation of the infrarenal abdominal aorta, termed an abdominal aortic aneurysm (AAA), is often times asymptomatic and may eventually result in rupture-an event associated with a significant mortality rate. The estimation of in-vivo stresses within AAAs has been proposed as a useful tool to predict the likel...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-008-9490-3

    authors: Vande Geest JP,Schmidt DE,Sacks MS,Vorp DA

    更新日期:2008-06-01 00:00:00

  • Impedances of thin and layered systems: cells with even or odd numbers of interfaces.

    abstract::Impedance data, e.g., system responses, from perturbing small amplitude applied sinusoid signals of near DC to high kilohertz frequencies, give chemical information. Analysis of frequency-dependent imaginary and real impedance proceeds from equivalent analog circuit elements to chemical and physical significance deter...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02368537

    authors: Buck RP

    更新日期:1992-01-01 00:00:00

  • Geometric and flow features of type B aortic dissection: initial findings and comparison of medically treated and stented cases.

    abstract::Uncomplicated acute type B aortic dissections are usually treated medically, but they can become acutely complicated by rapid expansion, rupture and malperfusion syndromes and in the longer term by chronic dilatation and aortic aneurysm formation. The objective of this study is to use computational fluid dynamics reco...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-014-1075-8

    authors: Cheng Z,Wood NB,Gibbs RG,Xu XY

    更新日期:2015-01-01 00:00:00

  • Masquelet Technique: Effects of Spacer Material and Micro-topography on Factor Expression and Bone Regeneration.

    abstract::We and others have shown that changing surface characteristics of the spacer implanted during the first Masquelet stage alters some aspects of membrane development. Previously we demonstrated that titanium (TI) spacers create membranes that are better barriers to movement of solutes > 70 kDa in size than polymethyl me...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-018-02137-5

    authors: Toth Z,Roi M,Evans E,Watson JT,Nicolaou D,McBride-Gagyi S

    更新日期:2019-01-01 00:00:00

  • MUlti-Dimensional Spline-Based Estimator (MUSE) for motion estimation: algorithm development and initial results.

    abstract::Image registration and motion estimation play central roles in many fields, including RADAR, SONAR, light microscopy, and medical imaging. Because of its central significance, estimator accuracy, precision, and computational cost are of critical importance. We have previously presented a highly accurate, spline-based ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-008-9564-2

    authors: Viola F,Coe RL,Owen K,Guenther DA,Walker WF

    更新日期:2008-12-01 00:00:00

  • A Conceivable Mechanism Responsible for the Synergy of High and Low Voltage Irreversible Electroporation Pulses.

    abstract::Irreversible electroporation (IRE), is a new non-thermal tissue ablation technology in which brief high electric field pulses are delivered across the target tissue to induce cell death by irreversible permeabilization of the cell membrane. A deficiency of conventional IRE is that the ablation zone is relatively small...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-019-02258-5

    authors: Lv Y,Yao C,Rubinsky B

    更新日期:2019-07-01 00:00:00

  • Low Impedance Carbon Adhesive Electrodes with Long Shelf Life.

    abstract::A novel electrocardiogram (ECG) electrode film is developed by mixing carbon black powder and a quaternary salt with a visco-elastic polymeric adhesive. Unlike traditional wet gel-based electrodes, carbon/salt/adhesive (CSA) electrodes should theoretically have an infinite shelf life as they do not dehydrate even afte...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1282-y

    authors: Posada-Quintero HF,Reyes BA,Burnham K,Pennace J,Chon KH

    更新日期:2015-10-01 00:00:00

  • Detecting Aortic Valve-Induced Abnormal Flow with Seismocardiography and Cardiac MRI.

    abstract::Cardiac MRI (CMR) techniques offer non-invasive visualizations of cardiac morphology and function. However, imaging can be time-consuming and complex. Seismocardiography (SCG) measures physical vibrations transmitted through the chest from the beating heart and pulsatile blood flow. SCG signals can be acquired quickly...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02491-3

    authors: Johnson EMI,Heller JA,Garcia Vicente F,Sarnari R,Gordon D,McCarthy PM,Barker AJ,Etemadi M,Markl M

    更新日期:2020-06-01 00:00:00

  • Why, When, Who, What, How, and Where for Trainees Writing Literature Review Articles.

    abstract::Literature review articles provide a valuable mechanism for remaining informed amidst an ever-increasing body of scientific work. Condensing current advances into this disseminatable form is a critical activity for any research trainee. To systematize this multifaceted process, we present the "why, when, who, what, ho...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-019-02290-5

    authors: Koons GL,Schenke-Layland K,Mikos AG

    更新日期:2019-11-01 00:00:00

  • Two methods for recommending bat weights.

    abstract::Baseball players swung very light and very heavy bats through our instrument and the speed of the bat was recorded. These data were used to make mathematical models for each person. Then these models were coupled with equations of physics for bat-ball collisions to compute the Ideal Bat Weight for each individual. How...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02584443

    authors: Bahill AT,Freitas MM

    更新日期:1995-07-01 00:00:00