Masquelet Technique: Effects of Spacer Material and Micro-topography on Factor Expression and Bone Regeneration.

Abstract:

:We and others have shown that changing surface characteristics of the spacer implanted during the first Masquelet stage alters some aspects of membrane development. Previously we demonstrated that titanium (TI) spacers create membranes that are better barriers to movement of solutes > 70 kDa in size than polymethyl methacrylate (PMMA) induced-membranes, and roughening creates more mechanically compliant membranes. However, it is unclear if these alterations affect the membrane's biochemical environment or bone regeneration during the second stage. Ten-week-old, male Sprague-Dawley rats underwent an initial surgery to create an externally stabilized 6 mm femoral defect. PMMA or TI spacers with smooth (~ 1 μm) or roughened (~ 8 μm) surfaces were implanted. Four weeks later, rats were either euthanized for membrane harvest or underwent the second Masquelet surgery. TI spacers induced thicker membranes that were similar in structure and biochemical expression. All membranes were bilayered with the inner layer having increased factor expression [bone morphogenetic protein 2 (BMP2), transforming growth factor beta (TGFβ), interleukin 6 (IL6), and vascular endothelial growth factor (VEGF)]. Roughening increased overall IL6 levels. Ten-weeks post-engraftment, PMMA-smooth induced membranes better supported bone regeneration (60% union). The other groups only had 1 or 2 that united (9-22%). There were no significant differences in any micro computed tomography or dynamic histology outcome. In conclusion, this study suggests that the membrane's important function in the Masquelet technique is not simply as a barrier. There is likely a critical biochemical, cellular, or vascular component as well.

journal_name

Ann Biomed Eng

authors

Toth Z,Roi M,Evans E,Watson JT,Nicolaou D,McBride-Gagyi S

doi

10.1007/s10439-018-02137-5

subject

Has Abstract

pub_date

2019-01-01 00:00:00

pages

174-189

issue

1

eissn

0090-6964

issn

1573-9686

pii

10.1007/s10439-018-02137-5

journal_volume

47

pub_type

杂志文章
  • Bioreactors for development of tissue engineered heart valves.

    abstract::Millions of people worldwide are diagnosed each year with valvular heart disease, resulting in hundreds of thousands of valve replacement operations. Prosthetic valve replacements are designed to correct narrowing or backflow through the valvular orifice. Although commonly used, these therapies have serious disadvanta...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/s10439-010-0148-6

    authors: Berry JL,Steen JA,Koudy Williams J,Jordan JE,Atala A,Yoo JJ

    更新日期:2010-11-01 00:00:00

  • Detergent-Based Decellularization of Bovine Carotid Arteries for Vascular Tissue Engineering.

    abstract::Vascular diseases are an increasing health issue, and common alloplastic, allogenic or autologous vascular grafts show frequent complications. The aim of this study is to develop an acellular, xenogenic bypass-graft from a bovine carotid artery (BAC) using detergent-based protocols. We compared decellularization with ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-017-1892-7

    authors: Daugs A,Hutzler B,Meinke M,Schmitz C,Lehmann N,Markhoff A,Bloch O

    更新日期:2017-11-01 00:00:00

  • In vitro characterization of a compliant biodegradable scaffold with a novel bioreactor system.

    abstract::The influence of scaffold compliance on blood vessel tissue engineering remains unclear and compliance mismatch issues are important to an in vivo tissue-engineering approach. We have designed and constructed a modular bioreactor system that is capable of imparting pulsatile fluid flow while simultaneously measuring v...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-007-9304-z

    authors: Webb AR,Macrie BD,Ray AS,Russo JE,Siegel AM,Glucksberg MR,Ameer GA

    更新日期:2007-08-01 00:00:00

  • Biomechanical Characterisation of the Human Auricular Cartilages; Implications for Tissue Engineering.

    abstract::Currently, autologous cartilage provides the gold standard for auricular reconstruction. However, synthetic biomaterials offer a number of advantages for ear reconstruction including decreased donor site morbidity and earlier surgery. Critical to implant success is the material's mechanical properties as this affects ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-016-1688-1

    authors: Griffin MF,Premakumar Y,Seifalian AM,Szarko M,Butler PE

    更新日期:2016-12-01 00:00:00

  • Development of a device for measuring adherence of skin grafts to the wound surface.

    abstract::Adherence of a biological graft to the wound surface is the most important factor influencing the ultimate success of graft viability. A machine has been developed to test the adherence of biological graft materials to a substrate such as a wound surface. The peeling mode, which yields reproducible quantitative measur...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02368164

    authors: Dong C,Mead E,Skalak R,Fung YC,Debes JC,Zapata-Sirvent RL,Andree C,Greenleaf G,Cooper M,Hansbrough JF

    更新日期:1993-01-01 00:00:00

  • Influence of autoregressive model parameter uncertainty on spectral estimates of heart rate dynamics.

    abstract::Linear autoregressive (AR) model-based heart rate (HR) spectral analysis has been widely used to study HR dynamics. Owing to system and measurement noise, the parameters of an AR model have intrinsic statistical uncertainty. In this study, we evaluate how this AR parameter uncertainty can translate to uncertainty in H...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02368320

    authors: Christini DJ,Kulkarni A,Rao S,Stutman ER,Bennett FM,Hausdorff JM,Oriol N,Lutchen KR

    更新日期:1995-03-01 00:00:00

  • Effects of hydration and fixed charge density on fluid transport in charged hydrated soft tissues.

    abstract::The effects of tissue hydration and fixed charge density on hydraulic permeability and creep behavior of cartilaginous tissues have been investigated using the triphasic theory and finite element methods. The empirical model for hydraulic permeability of uncharged gels and Mackie and Meares (1955) model for ion diffus...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1615576

    authors: Gu WY,Yao H

    更新日期:2003-11-01 00:00:00

  • Assessing the susceptibility to local buckling at the femoral neck cortex to age-related bone loss.

    abstract::Although it is known that long cortical bone structurally alter their area moment of inertia with age related bone loss maintaining their bending strength, the incidence of fragility fractures associated with cortical thinning still prevails. We hypothesize that cortical thinning with aging increases the local bucklin...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-009-9751-9

    authors: Lee T,Choi JB,Schafer BW,Segars WP,Eckstein F,Kuhn V,Beck TJ

    更新日期:2009-09-01 00:00:00

  • BMP-2 gene modified canine bMSCs promote ectopic bone formation mediated by a nonviral PEI derivative.

    abstract::The study was to explore the effects of BMP-2 gene modified canine bone marrow stromal cells (bMSCs) mediated by a nonviral PEI derivative (GenEscort™ II) in promoting bone formation in vitro and in vivo. Canine bMSCs were cultured and transfected with plasmids containing bone morphogenetic protein-2 gene (pBMP-2) or ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-011-0276-7

    authors: Lü K,Zeng D,Zhang Y,Xia L,Xu L,Kaplan DL,Jiang X,Zhang F

    更新日期:2011-06-01 00:00:00

  • New perspectives on bioengineering of joint tissues: joint adaptation creates a moving target for engineering replacement tissues.

    abstract::The current paradigm in tissue engineering is that "full regeneration" or "total replacement" of normal tissue is required in order to restore joint function. However, there is considerable evidence that suggests that targets other than "normality" may actually be required for tissue substitutes. Sometimes "less than ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1023/b:abme.0000017548.85451.b7

    authors: Frank CB,Shrive NG,Boorman RS,Lo IK,Hart DA

    更新日期:2004-03-01 00:00:00

  • Physiological acoustic sensing based on accelerometers: a survey for mobile healthcare.

    abstract::This paper reviews the applications of accelerometers on the detection of physiological acoustic signals such as heart sounds, respiratory sounds, and gastrointestinal sounds. These acoustic signals contain a rich reservoir of vital physiological and pathological information. Accelerometer-based systems enable continu...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/s10439-014-1111-8

    authors: Hu Y,Kim EG,Cao G,Liu S,Xu Y

    更新日期:2014-11-01 00:00:00

  • Mathematical models of the spatial distribution of retinal oxygen tension and consumption, including changes upon illumination.

    abstract::To better understand oxygen utilization by the retina, a mathematical model of oxygen diffusion and consumption in the cat outer, avascular retina was developed by analyzing previously recorded profiles of oxygen tension (PO2) as a function of retinal depth. Simple diffusion modelling of the oxygen distribution throug...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02368415

    authors: Haugh LM,Linsenmeier RA,Goldstick TK

    更新日期:1990-01-01 00:00:00

  • Prediction of the biomechanical effects of compression therapy on deep veins using finite element modelling.

    abstract::Clinicians generally assume that Medical Compression Stockings (MCS) work by reducing vein luminal diameter and, in this way, help to prevent blood pooling. Conflicting results have been reported however in the case of lower leg deep veins which call into question this hypothesis. The purpose of this contribution is t...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-014-1121-6

    authors: Rohan PY,Badel P,Lun B,Rastel D,Avril S

    更新日期:2015-02-01 00:00:00

  • Strategies to direct the enrichment, expansion, and recruitment of regulatory cells for the treatment of disease.

    abstract::Disease and injury perturb the balance of processes associated with inflammation and tissue remodeling, resulting in positive feedback loops, exacerbation of disease and compromised tissue repair. Conversely, under homeostatic healthy conditions, these processes are tightly regulated through the expansion and/or recru...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/s10439-014-1125-2

    authors: Glowacki AJ,Gottardi R,Yoshizawa S,Cavalla F,Garlet GP,Sfeir C,Little SR

    更新日期:2015-03-01 00:00:00

  • Fractal character of pulmonary microvascular permeability.

    abstract::The pulmonary microvasculature offers a heterogeneous barrier to the motion of large solutes as they pass between blood and lymph. While this barrier has been approximated by a few discrete pathways or by statistical ensembles of many pathways, these descriptions only partly capture the structural and functional prope...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02368425

    authors: McNamee JE

    更新日期:1990-01-01 00:00:00

  • Micro-computed tomography based computational fluid dynamics for the determination of shear stresses in scaffolds within a perfusion bioreactor.

    abstract::Perfusion bioreactors are known to exert shear stresses on cultured cells, leading to cell differentiation and enhanced extracellular matrix deposition on scaffolds. The influence of the scaffold's porous microstructure is investigated for a polycaprolactone (PCL) scaffold with a regular microarchitecture and a silk f...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-014-0981-0

    authors: Zermatten E,Vetsch JR,Ruffoni D,Hofmann S,Müller R,Steinfeld A

    更新日期:2014-05-01 00:00:00

  • Conductance method for the measurement of cross-sectional areas of the aorta.

    abstract::A modified conductance method to determine the cross-sectional areas (CSAs) of arteries in piglets was evaluated in vivo. The method utilized a conductance catheter having four electrodes. Between the outer electrodes an alternating current was applied and between the inner electrodes the induced voltage difference wa...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.219

    authors: Kornet L,Jansen JR,Gussenhoven EJ,Hardeman MR,Hoeks AP,Versprille A

    更新日期:1999-03-01 00:00:00

  • Partial Bone Formation in Additive Manufactured Porous Implants Reduces Predicted Stress and Danger of Fatigue Failure.

    abstract::New porous implant designs made possible by additive manufacturing allow for increased osseointegration, potentially improving implant performance and longevity for patients that require massive bone implants. The aim of this study was to evaluate how implantation and the strain distribution in the implant affect the ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-019-02369-z

    authors: Cheong VS,Fromme P,Coathup MJ,Mumith A,Blunn GW

    更新日期:2020-01-01 00:00:00

  • A Review of Material Degradation Modelling for the Analysis and Design of Bioabsorbable Stents.

    abstract::The field of percutaneous coronary intervention has witnessed many progressions over the last few decades, more recently with the advancement of fully degradable bioabsorbable stents. Bioabsorbable materials, such as metallic alloys and aliphatic polyesters, have the potential to yield stents which provide temporary s...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/s10439-015-1413-5

    authors: Boland EL,Shine R,Kelly N,Sweeney CA,McHugh PE

    更新日期:2016-02-01 00:00:00

  • Predictive Virtual Patient Modelling of Mechanical Ventilation: Impact of Recruitment Function.

    abstract::Mechanical ventilation is a life-support therapy for intensive care patients suffering from respiratory failure. To reduce the current rate of ventilator-induced lung injury requires ventilator settings that are patient-, time-, and disease-specific. A common lung protective strategy is to optimise the level of positi...

    journal_title:Annals of biomedical engineering

    pub_type: 临床试验,杂志文章

    doi:10.1007/s10439-019-02253-w

    authors: Morton SE,Knopp JL,Chase JG,Möller K,Docherty P,Shaw GM,Tawhai M

    更新日期:2019-07-01 00:00:00

  • A small angle light scattering device for planar connective tissue microstructural analysis.

    abstract::The planar fibrous connective tissues of the body are composed of a dense extracellular network of collagen and elastin fibers embedded in a ground matrix, and thus can be thought of as biocomposites. Thus, the quantification of fiber architecture is an important step in developing an understanding of the mechanics of...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02684845

    authors: Sacks MS,Smith DB,Hiester ED

    更新日期:1997-07-01 00:00:00

  • Neurite outgrowth on a DNA crosslinked hydrogel with tunable stiffnesses.

    abstract::Mechanical cues arising from extracellular matrices greatly affect cellular properties, and hence, are of significance in designing biomaterials. In this study, a DNA crosslinked hydrogel was employed to examine cellular responses of spinal cord neurons to substrate compliances. Using DNA as crosslinkers in polymeric ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-008-9530-z

    authors: Jiang FX,Yurke B,Firestein BL,Langrana NA

    更新日期:2008-09-01 00:00:00

  • Generalized sensitivity functions in physiological system identification.

    abstract::Parameters of physiological models are commonly associated in an input-output experiment with a specific pattern of the system response. This association is often made on an intuitive basis by traditional sensitivity analysis, i.e., by inspecting the variations of model output trajectories with respect to parameter va...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.207

    authors: Thomaseth K,Cobelli C

    更新日期:1999-09-01 00:00:00

  • Mathematical simulation of slowing of cardiac conduction velocity by elevated extracellular.

    abstract::We have studied the dependence of conduction velocity (theta) on extracellular potassium concentration ([K+]o) in a model of one-dimensional conduction using an idealized strand of human atrial cells. Elevated [K+]o in the 5-20 mM range shifts the resting potential (Vrest) in the depolarizing direction and reduces inp...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1308489

    authors: Nygren A,Giles WR

    更新日期:2000-08-01 00:00:00

  • An efficient technique for the numerical solution of the bidomain equations.

    abstract::Computing the numerical solution of the bidomain equations is widely accepted to be a significant computational challenge. In this study we extend a previously published semi-implicit numerical scheme with good stability properties that has been used to solve the bidomain equations (Whiteley, J.P. IEEE Trans. Biomed. ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-008-9513-0

    authors: Whiteley JP

    更新日期:2008-08-01 00:00:00

  • Influence of different presentations of oscillometric data on automatic determination of systolic and diastolic pressures.

    abstract::Most non-invasive blood pressure measurements are based on either the auscultatory or the oscillometric technique. In this study, we performed an extensive analysis of the signals, i.e., responses of a microphone implanted in the cuff and pressure changes in the cuff, which can be recorded during such measurements. We...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-009-9853-4

    authors: Jazbinsek V,Luznik J,Mieke S,Trontelj Z

    更新日期:2010-03-01 00:00:00

  • Analysis of electrically induced reentrant circuits in a sheet of myocardium.

    abstract::Understanding the complex spatiotemporal dynamics of action potential propagation in the heart during arrhythmia is exceedingly difficult. This study applies nonlinear dynamics tools to simplify this task. Using the results of a simulation of an electrical induction of reentry in a sheet of myocardium represented as a...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1581289

    authors: Larson C,Dragnev L,Trayanova N

    更新日期:2003-07-01 00:00:00

  • Spectral analysis of Doppler flow velocity signals: assessment of objectives, methods, and interpretation.

    abstract::The objective of this paper is to review the theoretical basis and clinical application of electrical impedance plethysmography in the noninvasive evaluation of peripheral arterial and venous disease. Theoretical, experimental and clinical studies have not demonstrated a direct relationship between electrical impedanc...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02410294

    authors: Zuech PE,Cobbold RS,Johnston KW,Kassam M

    更新日期:1984-01-01 00:00:00

  • Fatigue of Metallic Stents: From Clinical Evidence to Computational Analysis.

    abstract::The great success of stents in treating cardiovascular disease is actually undermined by their long-term fatigue failure. The high variability of stent failure incidence suggests that it is due to several correlated aspects, such as loading conditions, material properties, component design, surgical procedure, and pat...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1447-8

    authors: Auricchio F,Constantinescu A,Conti M,Scalet G

    更新日期:2016-02-01 00:00:00

  • Increases of corporal temperature as a risk factor of atherosclerotic plaque instability.

    abstract:BACKGROUND:This work explores for the first time the effects of temperature increments on the development of high shear stresses between plaque and arterial wall due to their different dilatational properties. Data from the literature report febrile reactions prior to myocardial infarction in patients with normal coron...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-007-9397-4

    authors: Guinea GV,Atienza JM,Fantidis P,Rojo FJ,Ortega A,Torres M,Gonzalez P,Elices ML,Hayashi K,Elices M

    更新日期:2008-01-01 00:00:00