Influence of different presentations of oscillometric data on automatic determination of systolic and diastolic pressures.

Abstract:

:Most non-invasive blood pressure measurements are based on either the auscultatory or the oscillometric technique. In this study, we performed an extensive analysis of the signals, i.e., responses of a microphone implanted in the cuff and pressure changes in the cuff, which can be recorded during such measurements. We applied several methods to separate the cuff deflation from the arterial pressure pulses, as well as to separate the microphone data into an audible part (Korotkoff sounds) and a low frequency part. The oscillometric technique is based on some empirically derived criteria applied to the oscillometric index, which is defined as a certain characteristic physical property of pressure pulses. In addition to the pressure pulses, which are a typical physical property used for the oscillometric index, we also used in this study other properties such as a time derivative and an audible part of data measured by a microphone implanted in the cuff (Korotkoff sounds). We performed a case study of 23 healthy subjects to evaluate the influence of different presentations of the oscillometric index on known height-based and slope-based empirical algorithms for the automatic determination of the systolic and diastolic blood pressures.

journal_name

Ann Biomed Eng

authors

Jazbinsek V,Luznik J,Mieke S,Trontelj Z

doi

10.1007/s10439-009-9853-4

subject

Has Abstract

pub_date

2010-03-01 00:00:00

pages

774-87

issue

3

eissn

0090-6964

issn

1573-9686

journal_volume

38

pub_type

杂志文章
  • Characterization of biaxial mechanical behavior of porcine aorta under gradual elastin degradation.

    abstract::Arteries are composed of multiple constituents that endow the wall with proper structure and function. Many vascular diseases are associated with prominent mechanical and biological alterations in the wall constituents. In this study, planar biaxial tensile test data of elastase-treated porcine aortic tissue (Chow et ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-012-0733-y

    authors: Zeinali-Davarani S,Chow MJ,Turcotte R,Zhang Y

    更新日期:2013-07-01 00:00:00

  • HFUS Imaging of the Cochlea: A Feasibility Study for Anatomical Identification by Registration with MicroCT.

    abstract::Cochlear implantation consists in electrically stimulating the auditory nerve by inserting an electrode array inside the cochlea, a bony structure of the inner ear. In the absence of any visual feedback, the insertion results in many cases of damages of the internal structures. This paper presents a feasibility study ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02671-1

    authors: Lavenir L,Zemiti N,Akkari M,Subsol G,Venail F,Poignet P

    更新日期:2020-10-30 00:00:00

  • Contourlet-based features for computerized tumor detection in capsule endoscopy images.

    abstract::This article presents a computer-aided detection system for capsule endoscopy (CE) images using contourlet-based color textural features to recognize tumors in the digestive tract. As tumor exhibits rich information in color texture, a novel color texture feature based on contourlet transform is proposed to describe c...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-011-0380-8

    authors: Li B,Meng MQ

    更新日期:2011-12-01 00:00:00

  • The air-conditioning capacity of the human nose.

    abstract::The nose is the front line defender of the respiratory system. Unsteady simulations in three-dimensional models have been developed to study transport patterns in the human nose and its overall air-conditioning capacity. The results suggested that the healthy nose can efficiently provide about 90% of the heat and the ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-005-2513-4

    authors: Naftali S,Rosenfeld M,Wolf M,Elad D

    更新日期:2005-04-01 00:00:00

  • Distribution of internal strains around bony prominences in pigs.

    abstract::Deep tissue injury (DTI) is a type of pressure ulcer in which tissue breakdown initiates at the bone-muscle interface under intact skin. Excessive deformation in the soft tissue, particularly around bony prominences, is believed to be one of the causes leading to the development of DTI. The main goal of this study was...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-012-0539-y

    authors: Solis LR,Liggins AB,Seres P,Uwiera RR,Poppe NR,Pehowich E,Thompson RB,Mushahwar VK

    更新日期:2012-08-01 00:00:00

  • An optimization-based simultaneous approach to the determination of muscular, ligamentous, and joint contact forces provides insight into musculoligamentous interaction.

    abstract::Typical inverse dynamics approaches to the calculation of muscle, ligament, and joint contact forces are based on a step-wise solution of the equations of motion. This approach is therefore limited in its ability to provide insight as to the muscular, ligamentous, and articular interactions that create joint stability...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-011-0303-8

    authors: Cleather DJ,Bull AM

    更新日期:2011-07-01 00:00:00

  • Influence of autoregressive model parameter uncertainty on spectral estimates of heart rate dynamics.

    abstract::Linear autoregressive (AR) model-based heart rate (HR) spectral analysis has been widely used to study HR dynamics. Owing to system and measurement noise, the parameters of an AR model have intrinsic statistical uncertainty. In this study, we evaluate how this AR parameter uncertainty can translate to uncertainty in H...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02368320

    authors: Christini DJ,Kulkarni A,Rao S,Stutman ER,Bennett FM,Hausdorff JM,Oriol N,Lutchen KR

    更新日期:1995-03-01 00:00:00

  • Segmentation and Pore Structure Estimation in SEM Images of Tissue Engineering Scaffolds Using Genetic Algorithm.

    abstract::A python computer package is developed to segment and analyze scanning electron microscope (SEM) images of scaffolds for bone tissue engineering. The method requires only a portion of an SEM image to be labeled and used for training. The algorithm is then able to detect the pore characteristics for other SEM images ac...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02638-2

    authors: Rouhollahi A,Ilegbusi O,Foroosh H

    更新日期:2020-10-15 00:00:00

  • The Effects of 4%Fe on the Performance of Pure Zinc as Biodegradable Implant Material.

    abstract::The efforts to develop structural materials for biodegradable metal implants have lately shifted their focus from Magnesium and Iron base alloys towards Zinc. This was mainly due to the accelerated corrosion rate of Mg that is accompanied by hydrogen gas evolution, formation of voluminous iron oxide products with redu...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-019-02245-w

    authors: Kafri A,Ovadia S,Yosafovich-Doitch G,Aghion E

    更新日期:2019-06-01 00:00:00

  • Body-worn sensor design: what do patients and clinicians want?

    abstract::User preferences need to be taken into account in order to be able to design devices that will gain acceptance both in a clinical and home setting. Sensor systems become redundant if patients or clinicians do not want to work with them. The aim of this systematic review was to determine both patients' and clinicians' ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/s10439-011-0339-9

    authors: Bergmann JH,McGregor AH

    更新日期:2011-09-01 00:00:00

  • CareToy: Stimulation and Assessment of Preterm Infant's Activity Using a Novel Sensorized System.

    abstract::Early intervention programs aim at improving cognitive and motor outcomes of preterm infants. Intensive custom-tailored training activities are usually accompanied by assessment procedures, which have shortcomings, such as subjectivity, complex setups, and need for structured environments. A novel sensorized system, c...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-016-1669-4

    authors: Rihar A,Sgandurra G,Beani E,Cecchi F,Pašič J,Cioni G,Dario P,Mihelj M,Munih M

    更新日期:2016-12-01 00:00:00

  • Flow perfusion culture of marrow stromal cells seeded on porous biphasic calcium phosphate ceramics.

    abstract::Calcium phosphate ceramics have been widely used for filling bone defects to aid in the regeneration of new bone tissue. Addition of osteogenic cells to porous ceramic scaffolds may accelerate the bone repair process. This study demonstrates the feasibility of culturing marrow stromal cells (MSCs) on porous biphasic c...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-005-5536-y

    authors: Holtorf HL,Sheffield TL,Ambrose CG,Jansen JA,Mikos AG

    更新日期:2005-09-01 00:00:00

  • Coupling of a 3D finite element model of cardiac ventricular mechanics to lumped systems models of the systemic and pulmonic circulation.

    abstract::In this study we present a novel, robust method to couple finite element (FE) models of cardiac mechanics to systems models of the circulation (CIRC), independent of cardiac phase. For each time step through a cardiac cycle, left and right ventricular pressures were calculated using ventricular compliances from the FE...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-006-9212-7

    authors: Kerckhoffs RC,Neal ML,Gu Q,Bassingthwaighte JB,Omens JH,McCulloch AD

    更新日期:2007-01-01 00:00:00

  • Modeling life.

    abstract::We seek to construct physical and mathematical models of life. Such models allow us to test our understanding of how living systems function and how they respond to human imposed stimuli. One system is a genomically and chemically complete model of a minimal cell. This cell is a hypothetical bacterium with the fewest ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/s10439-012-0567-7

    authors: Shuler ML

    更新日期:2012-07-01 00:00:00

  • Detergent-Based Decellularization of Bovine Carotid Arteries for Vascular Tissue Engineering.

    abstract::Vascular diseases are an increasing health issue, and common alloplastic, allogenic or autologous vascular grafts show frequent complications. The aim of this study is to develop an acellular, xenogenic bypass-graft from a bovine carotid artery (BAC) using detergent-based protocols. We compared decellularization with ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-017-1892-7

    authors: Daugs A,Hutzler B,Meinke M,Schmitz C,Lehmann N,Markhoff A,Bloch O

    更新日期:2017-11-01 00:00:00

  • Multi-scale computational models of pro-angiogenic treatments in peripheral arterial disease.

    abstract::The induction of angiogenesis is a promising therapeutic strategy for the amelioration of peripheral arterial disease (PAD). This occlusive disease results in muscle ischemia, and neovascularization is a route to increasing the perfusion in the tissue. The vascular endothelial growth factor (VEGF) family of potent pro...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-007-9303-0

    authors: Mac Gabhann F,Ji JW,Popel AS

    更新日期:2007-06-01 00:00:00

  • Emerging Brain Morphologies from Axonal Elongation.

    abstract::Understanding the characteristic morphology of our brain remains a challenging, yet important task in human evolution, developmental biology, and neurosciences. Mathematical modeling shapes our understanding of cortical folding and provides functional relations between cortical wavelength, thickness, and stiffness. Ye...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1312-9

    authors: Holland MA,Miller KE,Kuhl E

    更新日期:2015-07-01 00:00:00

  • Polycrystalline silicon micromachining: a new technology for integrated sensors.

    abstract::Polycrystalline silicon (poly-Si) micromechanical structures can be made by selectively etching an underlying sacrificial oxide layer. Advantages of this micromachining technique are its simplicity and compatibility with conventional integrated-circuit processing. Compressive internal stress in poly-Si films constrain...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02584269

    authors: Howe RT

    更新日期:1986-01-01 00:00:00

  • Tissue remodeling of rat pulmonary artery in hypoxic breathing. II. Course of change of mechanical properties.

    abstract::When cells and the matrix of a tissue remodel, the mechanical properties of the tissue do change. The mechanical properties are expressed by constitutive equations. In this article the remodeling of the constitutive equation of the pulmonary artery is studied. The remodeling was induced in a rat breathing a gas whose ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1380417

    authors: Huang W,Delgado-West D,Wu JT,Fung YC

    更新日期:2001-01-01 00:00:00

  • Biomechanical Response Targets of Adult Human Ribs in Frontal Impacts.

    abstract::Thorax injuries mainly due to rib fractures have been associated with high rates of morbidity and mortality in motor vehicle crashes. Thoracic biomechanics has been studied extensively, but there are no robust biomechanical response targets for ribs that consider age, sex, body size, and vulnerability factors. The obj...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02613-x

    authors: Kang YS,Kwon HJ,Stammen J,Moorhouse K,Agnew AM

    更新日期:2021-02-01 00:00:00

  • An inverse approach to determine solute and solvent permeability parameters in artificial tissues.

    abstract::This study presents a generic numerical model to simulate the coupled solute and solvent transport in tissue sections during addition and removal of chemical additives or cryoprotective agents (CPA; dimethylsulfoxide or DMSO). Osmotic responses of various tissue cells within the artificial tissue are predicted by the ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-005-1511-x

    authors: He Y,Devireddy RV

    更新日期:2005-05-01 00:00:00

  • Binary segmentation masks can improve intrasubject registration accuracy of bone structures in CT images.

    abstract::Registration of bone structures is a common problem in medical research as well as in clinical applications. Intrasubject rigid 3D monomodality registration of segmented bone structures of CT images and multimodality registration of muMR and segmented muCT bone images were performed with the multiresolution intensity-...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-9981-x

    authors: Museyko O,Eisa F,Hess A,Schett G,Kalender WA,Engelke K

    更新日期:2010-07-01 00:00:00

  • Myofiber ellipticity as an explanation for transverse asymmetry of skeletal muscle diffusion MRI in vivo signal.

    abstract::Due to its unique non-invasive microstructure probing capabilities, diffusion tensor imaging (DTI) constitutes a valuable tool in the study of fiber orientation in skeletal muscles. By implementing a DTI sequence with judiciously chosen directional encoding to quantify in vivo the microarchitectural properties in the ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-009-9783-1

    authors: Karampinos DC,King KF,Sutton BP,Georgiadis JG

    更新日期:2009-12-01 00:00:00

  • The tendon injury response is influenced by decorin and biglycan.

    abstract::Defining the constituent regulatory molecules in tendon is critical to understanding the process of tendon repair and instructive to the development of novel treatment modalities. The purpose of this study is to define the structural, expressional, and mechanical changes in the tendon injury response, and elucidate th...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-013-0915-2

    authors: Dunkman AA,Buckley MR,Mienaltowski MJ,Adams SM,Thomas SJ,Satchell L,Kumar A,Pathmanathan L,Beason DP,Iozzo RV,Birk DE,Soslowsky LJ

    更新日期:2014-03-01 00:00:00

  • A piconewton force transducer and its application to measurement of the bending stiffness of phospholipid membranes.

    abstract::The bending stiffness of a phospholipid bilayer (Kc) was measured by forming thin bilayer cylinders (tethers) from giant phospholipid vesicles. Based on the balance of forces, the tether force was expected to be proportional to the square root of the membrane tension, with a constant of proportionality containing Kc. ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02684228

    authors: Heinrich V,Waugh RE

    更新日期:1996-09-01 00:00:00

  • Holographic interferometry: a critique of the technique and its potential for biomedical measurements.

    abstract::Double-exposure holographic interferometry is a contactless whole-field method. Dimensional changes are visualized as a series of interference fringes overlaid on the holographic image of the femur, where each fringe represents 0.316 micron (half the wavelength of the laser light) of motion. Interferograms for intact ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02364168

    authors: Ovryn B,Manley MT,Stern LS

    更新日期:1987-01-01 00:00:00

  • Integration of clinical data collected at different times for virtual surgery in single ventricle patients: a case study.

    abstract::Newborns with single ventricle physiology are usually palliated with a multi-staged procedure. When cardiovascular complications e.g., collateral vessel formation occur during the inter-stage periods, further treatments are required. An 8-month-old patient, who underwent second stage (i.e., bi-directional Glenn, BDG) ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-014-1113-6

    authors: Corsini C,Baker C,Baretta A,Biglino G,Hlavacek AM,Hsia TY,Kung E,Marsden A,Migliavacca F,Vignon-Clementel I,Pennati G,Modeling of Congenital Hearts Alliance (MOCHA) Investigators.

    更新日期:2015-06-01 00:00:00

  • Fatigue of Metallic Stents: From Clinical Evidence to Computational Analysis.

    abstract::The great success of stents in treating cardiovascular disease is actually undermined by their long-term fatigue failure. The high variability of stent failure incidence suggests that it is due to several correlated aspects, such as loading conditions, material properties, component design, surgical procedure, and pat...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1447-8

    authors: Auricchio F,Constantinescu A,Conti M,Scalet G

    更新日期:2016-02-01 00:00:00

  • A Battery-Powered Ankle Exoskeleton Improves Gait Mechanics in a Feasibility Study of Individuals with Cerebral Palsy.

    abstract::Neuromuscular impairment associated with cerebral palsy (CP) often leads to life-long walking deficits. Our goal was to evaluate the ability of a novel untethered wearable ankle exoskeleton to reduce the severity of gait pathology from CP. In this clinical feasibility study of five individuals with CP, we used instrum...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-019-02237-w

    authors: Lerner ZF,Harvey TA,Lawson JL

    更新日期:2019-06-01 00:00:00

  • The placement of skin surface markers for non-invasive measurement of scapular kinematics affects accuracy and reliability.

    abstract::Abnormal scapular movement is widely believed to be an important factor in clinical pathology of the shoulder joint complex. Validated non-invasive techniques for measuring scapular movement have been developed, but the effect of marker placement on accuracy is unknown. The objective of this study was to determine the...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-0185-1

    authors: Bourne DA,Choo AM,Regan WD,MacIntyre DL,Oxland TR

    更新日期:2011-02-01 00:00:00