The placement of skin surface markers for non-invasive measurement of scapular kinematics affects accuracy and reliability.

Abstract:

:Abnormal scapular movement is widely believed to be an important factor in clinical pathology of the shoulder joint complex. Validated non-invasive techniques for measuring scapular movement have been developed, but the effect of marker placement on accuracy is unknown. The objective of this study was to determine the accuracy and reliability of different groupings of markers to achieve the best accuracy and reliability for measuring scapular kinematics. Eight healthy young adult subjects were recruited. An optoelectronic marker grid was applied to the skin overlying the scapula. Two bone pins with optoelectronic marker carriers were inserted into the scapula. The accuracy of six surface marker configurations was determined by comparing the measured kinematics with scapular bone pins (the gold standard). Four humeral movements were tested: glenohumeral abduction, glenohumeral horizontal adduction, hand behind back, and forward reaching. All three rotations had a significant difference in the accuracy of the patches (p = 0.04 to p < 0.0001). For posterior tipping there was a significant effect of movement (p = 0.003) and a significant interaction (p < 0.0001). There was also a significant interaction for external rotation (p = 0.001). The marker grouping with the largest cranio-caudal spread had the highest accuracy for measuring posterior tilting (RMS 1.9°). Markers closer to the scapular spine were more accurate for tracking external rotation (RMS 2.0°) while an intermediate grouping of markers were most accurate for quantifying upward rotation (RMS 1.9°). The reliability between days ranged between 3.8° and 7.5° (based on RMS difference between trials) and there was a significant interaction between patch and movement (p < 0.0001). Intraclass correlation coefficients show moderate to good agreement for most arm movements and scapular rotations. Thus, there exists distinct optimal configurations of non-invasive marker locations for accurately measuring scapular kinematics.

journal_name

Ann Biomed Eng

authors

Bourne DA,Choo AM,Regan WD,MacIntyre DL,Oxland TR

doi

10.1007/s10439-010-0185-1

subject

Has Abstract

pub_date

2011-02-01 00:00:00

pages

777-85

issue

2

eissn

0090-6964

issn

1573-9686

journal_volume

39

pub_type

杂志文章
  • Particle motion within in vitro models of stenosed internal carotid and left anterior descending coronary arteries.

    abstract::Asymmetric 75% and 95% area reduction, transparent Sylgard stenotic models were operated under internal carotid artery (ICA) [Womersley parameter, alpha=5.36, Re(mean) =213 and 180, respectively, and Re(peak)=734 and 410, respectively] and left anterior descending coronary artery (LAD) flow wave forms (alpha=2.65, Re(...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.131

    authors: Cao J,Rittgers SE

    更新日期:1998-03-01 00:00:00

  • Cellular and Nuclear Alignment Analysis for Determining Epithelial Cell Chirality.

    abstract::Left-right (LR) asymmetry is a biologically conserved property in living organisms that can be observed in the asymmetrical arrangement of organs and tissues and in tissue morphogenesis, such as the directional looping of the gastrointestinal tract and heart. The expression of LR asymmetry in embryonic tissues can be ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1431-3

    authors: Raymond MJ Jr,Ray P,Kaur G,Singh AV,Wan LQ

    更新日期:2016-05-01 00:00:00

  • Identification of static and dynamic components of reflex sensitivity in spastic elbow flexors using a muscle activation model.

    abstract::Static and dynamic components of the stretch reflex were studied in elbow flexors of 13 hemiparetic brain-injured individuals. Constant-velocity joint rotations were applied to the elbow, and the resulting stretch reflex torque and electromyographic responses were recorded in the biceps brachii and brachioradialis mus...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1359496

    authors: Schmit BD,Rymer WZ

    更新日期:2001-04-01 00:00:00

  • High-resolution 3D ultrasound jawbone surface imaging for diagnosis of periodontal bony defects: an in vitro study.

    abstract::Although medical specialties have recognized the importance of using ultrasonic imaging, dentistry is only beginning to discover its benefit. This has particularly been important in the field of periodontics which studies infections in the gum and bone tissues that surround the teeth. This study investigates the feasi...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-0089-0

    authors: Mahmoud AM,Ngan P,Crout R,Mukdadi OM

    更新日期:2010-11-01 00:00:00

  • Multi-molecular gradients of permissive and inhibitory cues direct neurite outgrowth.

    abstract::Correct development of neuronal tracts requires the coordination of multiple permissive and inhibitory signals. By generating an in vitro microenvironment using soft lithography and microfluidic techniques, multiple guidance cues can be presented in a spatially defined way. Here we evaluated how neurites of dorsal roo...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-008-9486-z

    authors: Li GN,Liu J,Hoffman-Kim D

    更新日期:2008-06-01 00:00:00

  • Intrinsic oscillations and discharge regularity of units in the dorsal cochlear nucleus (DCN) of the barbiturate anesthetized gerbil.

    abstract::Spike discharge patterns showing intrinsic oscillations (IOs) have been reported in units in the dorsal cochlear nucleus (DCN) of the decerebrate cat. These oscillations are related to the regularity of a unit's discharge rate and may be important for pitch perception. A DCN unit's regularity can be affected by severa...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.96

    authors: Gdowski GT,Voigt HF

    更新日期:1998-05-01 00:00:00

  • Design Considerations of a Fiber Optic Pressure Sensor Protective Housing for Intramuscular Pressure Measurements.

    abstract::Intramuscular pressure (IMP), defined as skeletal muscle interstitial fluid pressure, reflects changes in individual muscle tension and may provide crucial insight into musculoskeletal biomechanics and pathologies. IMP may be measured using fiber-optic fluid pressure sensors, provided the sensor is adequately anchored...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-016-1703-6

    authors: Go SA,Jensen ER,O'Connor SM,Evertz LQ,Morrow DA,Ward SR,Lieber RL,Kaufman KR

    更新日期:2017-03-01 00:00:00

  • Body-worn sensor design: what do patients and clinicians want?

    abstract::User preferences need to be taken into account in order to be able to design devices that will gain acceptance both in a clinical and home setting. Sensor systems become redundant if patients or clinicians do not want to work with them. The aim of this systematic review was to determine both patients' and clinicians' ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/s10439-011-0339-9

    authors: Bergmann JH,McGregor AH

    更新日期:2011-09-01 00:00:00

  • Analyzing trends in brain interface technology: a method to compare studies.

    abstract::Continued progress in the field of Brain Interface (BI) research has encouraged the rapid expansion of the BI community over the last two decades. As the number of BI researchers and organizations steadily increases, newer and more advanced technologies are constantly produced, evaluated, and reported. Though the BI c...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-005-9055-7

    authors: Jackson MM,Mason SG,Birch GE

    更新日期:2006-05-01 00:00:00

  • Stochastic system identification of skin properties: linear and wiener static nonlinear methods.

    abstract::Wiener static nonlinear system identification was used to study the linear dynamics and static nonlinearities in the response of skin and underlying tissue under indentation in vivo. A device capable of measuring the dynamic mechanical properties of bulk skin tissue was developed and it incorporates a custom-built Lor...

    journal_title:Annals of biomedical engineering

    pub_type: 临床试验,杂志文章

    doi:10.1007/s10439-012-0580-x

    authors: Chen Y,Hunter IW

    更新日期:2012-10-01 00:00:00

  • Nanoparticle-Mediated TGF-β Release from Microribbon-Based Hydrogels Accelerates Stem Cell-Based Cartilage Formation In Vivo.

    abstract::Conventional nanoporous hydrogels often lead to slow cartilage deposition by MSCs in 3D due to physical constraints and requirement for degradation. Our group has recently reported macroporous gelatin microribbon (μRB) hydrogels, which substantially accelerate MSC-based cartilage formation in vitro compared to convent...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02522-z

    authors: Barati D,Gegg C,Yang F

    更新日期:2020-07-01 00:00:00

  • Assessment of daily-life reaching performance after stroke.

    abstract::For an optimal guidance of the rehabilitation therapy of stroke patients in an in-home setting, objective, and patient-specific performance assessment of arm movements is needed. In this study, metrics of hand movement relative to the pelvis and the sternum were estimated in 13 stroke subjects using a full body ambula...

    journal_title:Annals of biomedical engineering

    pub_type: 临床试验,杂志文章

    doi:10.1007/s10439-014-1198-y

    authors: van Meulen FB,Reenalda J,Buurke JH,Veltink PH

    更新日期:2015-02-01 00:00:00

  • Cardiac Multi-detector CT Segmentation Based on Multiscale Directional Edge Detector and 3D Level Set.

    abstract::Extraction of the cardiac surfaces of interest from multi-detector computed tomographic (MDCT) data is a pre-requisite step for cardiac analysis, as well as for image guidance procedures. Most of the existing methods need manual corrections, which is time-consuming. We present a fully automatic segmentation technique ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,随机对照试验

    doi:10.1007/s10439-015-1422-4

    authors: Antunes S,Esposito A,Palmisano A,Colantoni C,Cerutti S,Rizzo G

    更新日期:2016-05-01 00:00:00

  • An experimental evaluation of the use of an ensemble average for the calculation of turbulence in pulsatile flow.

    abstract::A comparison was made between turbulence calculated by subtracting an ensemble average from the instantaneous velocity and calculations made with a high pass digital filter. Velocity was measured with a laser Doppler anemometer in vitro in the region of a normal porcine aortic valve and in patients with a hot film ane...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02584215

    authors: Walburn FJ,Sabbah HN,Stein PD

    更新日期:1983-01-01 00:00:00

  • Impact of Pulmonary Venous Inflow on Cardiac Flow Simulations: Comparison with In Vivo 4D Flow MRI.

    abstract::Blood flow simulations are making their way into the clinic, and much attention is given to estimation of fractional flow reserve in coronary arteries. Intracardiac blood flow simulations also show promising results, and here the flow field is expected to depend on the pulmonary venous (PV) flow rates. In the absence ...

    journal_title:Annals of biomedical engineering

    pub_type: 临床试验,杂志文章

    doi:10.1007/s10439-018-02153-5

    authors: Lantz J,Gupta V,Henriksson L,Karlsson M,Persson A,Carlhäll CJ,Ebbers T

    更新日期:2019-02-01 00:00:00

  • Vortex ring formation in the left ventricle of the heart: analysis by 4D flow MRI and Lagrangian coherent structures.

    abstract::Recent studies suggest that vortex ring formation during left ventricular (LV) rapid filling is an optimized mechanism for blood transport, and that the volume of the vortex ring is an important measure. However, due to lack of quantitative methods, the volume of the vortex ring has not previously been studied. Lagran...

    journal_title:Annals of biomedical engineering

    pub_type: 临床试验,杂志文章

    doi:10.1007/s10439-012-0615-3

    authors: Töger J,Kanski M,Carlsson M,Kovács SJ,Söderlind G,Arheden H,Heiberg E

    更新日期:2012-12-01 00:00:00

  • Sustained Efficacy and Arterial Drug Retention by a Fast Drug Eluting Cross-Linked Fatty Acid Coronary Stent Coating.

    abstract::The long held assumption that sustained drug elution from stent coatings over weeks to months is imperative for clinical efficacy has limited the choice for stent coating materials. We developed and evaluated an omega-3 fatty acid (O3FA) based stent coating that is 85% absorbed and elutes 97% of its Sirolimus analog (...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1435-z

    authors: Artzi N,Tzafriri AR,Faucher KM,Moodie G,Albergo T,Conroy S,Corbeil S,Martakos P,Virmani R,Edelman ER

    更新日期:2016-02-01 00:00:00

  • Hemodynamic energy dissipation in the cardiovascular system: generalized theoretical analysis on disease states.

    abstract:BACKGROUND:We present a fundamental theoretical framework for analysis of energy dissipation in any component of the circulatory system and formulate the full energy budget for both venous and arterial circulations. New indices allowing disease-specific subject-to-subject comparisons and disease-to-disease hemodynamic ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-009-9650-0

    authors: Dasi LP,Pekkan K,de Zelicourt D,Sundareswaran KS,Krishnankutty R,Delnido PJ,Yoganathan AP

    更新日期:2009-04-01 00:00:00

  • Biomechanical topography of human ankle cartilage.

    abstract::The material properties of normal cadaveric human cartilage in the ankle mortice (tibiotalar articulation) were evaluated to determine a possible etiologic mechanism of cartilage injury of the ankle when an obvious traumatic episode is not present. Using an automated indentation apparatus and the biphasic creep indent...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02584467

    authors: Athanasiou KA,Niederauer GG,Schenck RC Jr

    更新日期:1995-09-01 00:00:00

  • Analyzing Remodeling of Cardiac Tissue: A Comprehensive Approach Based on Confocal Microscopy and 3D Reconstructions.

    abstract::Microstructural characterization of cardiac tissue and its remodeling in disease is a crucial step in many basic research projects. We present a comprehensive approach for three-dimensional characterization of cardiac tissue at the submicrometer scale. We developed a compression-free mounting method as well as labelin...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1465-6

    authors: Seidel T,Edelmann JC,Sachse FB

    更新日期:2016-05-01 00:00:00

  • Multifunctional FePt nanoparticles for radiation-guided targeting and imaging of cancer.

    abstract::A multifunctional FePt nanoparticle was developed that targets tumor microvasculature via "radiation-guided" peptides, and is detected by both near-infrared (NIR) fluorescence imaging and analytical mass spectrometry methods. Tumor specific binding was first measured by biotinylated peptide linked to fluorophore-conju...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-0219-8

    authors: Hariri G,Wellons MS,Morris WH 3rd,Lukehart CM,Hallahan DE

    更新日期:2011-03-01 00:00:00

  • Modeling the instantaneous pressure-volume relation of the left ventricle: a comparison of six models.

    abstract::Simulations are useful to study the heart's ability to generate flow and the interaction between contractility and loading conditions. The left ventricular pressure-volume (PV) relation has been shown to be nonlinear, but it is unknown whether a linear model is accurate enough for simulations. Six models were fitted t...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-009-9742-x

    authors: Lankhaar JW,Rövekamp FA,Steendijk P,Faes TJ,Westerhof BE,Kind T,Vonk-Noordegraaf A,Westerhof N

    更新日期:2009-09-01 00:00:00

  • Passive-dynamic ankle-foot orthoses substitute for ankle strength while causing adaptive gait strategies: a feasibility study.

    abstract::Bending stiffness of passive-dynamic ankle-foot orthoses (PD-AFOs) is a functional characteristic thought to restore lost ankle function due to weakened plantar flexors. However, lower extremity impairment profiles of patients are seldom limited to plantar flexion weakness, and PD-AFO characteristics often influence g...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-014-1067-8

    authors: Arch ES,Stanhope SJ

    更新日期:2015-02-01 00:00:00

  • Fluid dynamics of gas exchange in high-frequency oscillatory ventilation: in vitro investigations in idealized and anatomically realistic airway bifurcation models.

    abstract::The objective of this work is to develop understanding of the local fluid dynamic mechanisms that underpin gas exchange in high-frequency oscillatory ventilation (HFOV). The flow field during HFOV was investigated experimentally using particle image velocimetry in idealized and realistic models of a single bifurcation...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-008-9557-1

    authors: Heraty KB,Laffey JG,Quinlan NJ

    更新日期:2008-11-01 00:00:00

  • MEG connectivity analysis in patients with Alzheimer's disease using cross mutual information and spectral coherence.

    abstract::Alzheimer's disease (AD) is an irreversible brain disorder which represents the most common form of dementia in western countries. An early and accurate diagnosis of AD would enable to develop new strategies for managing the disease; however, nowadays there is no single test that can accurately predict the development...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-0155-7

    authors: Alonso JF,Poza J,Mañanas MA,Romero S,Fernández A,Hornero R

    更新日期:2011-01-01 00:00:00

  • In situ Microrheological Determination of Neutrophil Stiffening Following Adhesion in a Model Capillary.

    abstract::There has been considerable debate on the relative importance of biochemical stimuli and mechanical deformation in neutrophil adhesion in lung capillaries, a process observed following bacterial infection in the body. In contrast to venules, where the vessel diameter is larger than the leukocyte diameter (6-9 microm) ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-008-9437-8

    authors: Pai A,Sundd P,Tees DF

    更新日期:2008-04-01 00:00:00

  • A novel approach to track fetal movement using multi-sensor magnetocardiographic recordings.

    abstract::Changes in fetal magnetocardiographic (fMCG) signals are indicators for fetal body movement. We propose a novel approach to reliably extract fetal body movements based on the field strength of the fMCG signal independent of its frequency. After attenuating the maternal MCG, we use a Hilbert transform approach to ident...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-0231-z

    authors: Govindan RB,Vairavan S,Ulusar UD,Wilson JD,McKelvey SS,Preissl H,Eswaran H

    更新日期:2011-03-01 00:00:00

  • Fractal character of pulmonary microvascular permeability.

    abstract::The pulmonary microvasculature offers a heterogeneous barrier to the motion of large solutes as they pass between blood and lymph. While this barrier has been approximated by a few discrete pathways or by statistical ensembles of many pathways, these descriptions only partly capture the structural and functional prope...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02368425

    authors: McNamee JE

    更新日期:1990-01-01 00:00:00

  • Preparation of chitosan/hydroxyapatite substrates with controllable osteoconductivity tracked by AFM.

    abstract::In this study, cell-material adhesive strength and cellular mechanical properties were measured using atomic force microscopy (AFM) to track cell attachment and osteogenic differentiation. First, chitosan substrates were treated with simulated body fluid (SBF) for various periods, resulting in substrates with differen...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-014-1162-x

    authors: Ho MH,Li CH,Hsiao SW,Thien DV

    更新日期:2015-04-01 00:00:00

  • Estimation of Reynolds shear stresses during pulsatile flow in the region of aortic valves.

    abstract::Some investigators have attempted to estimate the Reynolds shear stress on the basis of a single component of velocity. The purpose of this investigation is to determine the validity of such estimates in a complex flow field, such as occurs in the cardiovascular system in the region of the aortic valve. Turbulent velo...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02371247

    authors: Walburn FJ,Sabbah HN,Stein PD

    更新日期:1985-01-01 00:00:00