Intrinsic oscillations and discharge regularity of units in the dorsal cochlear nucleus (DCN) of the barbiturate anesthetized gerbil.

Abstract:

:Spike discharge patterns showing intrinsic oscillations (IOs) have been reported in units in the dorsal cochlear nucleus (DCN) of the decerebrate cat. These oscillations are related to the regularity of a unit's discharge rate and may be important for pitch perception. A DCN unit's regularity can be affected by several factors including: synaptic architecture, cell membrane properties, and the auditory nerve discharge rate. Responses to multiple presentations of short-duration tone bursts (200 ms duration, 1 s trial) at the unit's best frequency (BF) at 20 dB re threshold were recorded from 297 units in the DCN of the barbiturate-anesthetized gerbil. Comparisons of unit regularity properties and IO properties are shown. The relative power spectrum (Fourier transform of the autocorrelogram normalized by the average rate) was used to quantify IO properties. Most units (84%) exhibited IOs in their sustained discharge rate. With the exception of Onset units and most bursting units, the mean inter-spike interval was correlated with the IO frequency and the coefficient of variation was correlated with the IO magnitude. These results suggest that stimulus-encoding mechanisms utilizing IOs may depend on the temporal evolution of the units' regularity properties.

journal_name

Ann Biomed Eng

authors

Gdowski GT,Voigt HF

doi

10.1114/1.96

subject

Has Abstract

pub_date

1998-05-01 00:00:00

pages

473-87

issue

3

eissn

0090-6964

issn

1573-9686

journal_volume

26

pub_type

杂志文章
  • Geometric and flow features of type B aortic dissection: initial findings and comparison of medically treated and stented cases.

    abstract::Uncomplicated acute type B aortic dissections are usually treated medically, but they can become acutely complicated by rapid expansion, rupture and malperfusion syndromes and in the longer term by chronic dilatation and aortic aneurysm formation. The objective of this study is to use computational fluid dynamics reco...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-014-1075-8

    authors: Cheng Z,Wood NB,Gibbs RG,Xu XY

    更新日期:2015-01-01 00:00:00

  • The effect of ultrasonic frequency upon enhanced killing of P. aeruginosa biofilms.

    abstract::It is widely recognized that the bacteria sequestered in a biofilm on a medical implant are much more resistant to antibiotics than their planktonic counterparts. Recent studies have shown that application of antibiotic along with low power ultrasound significantly increases the killing of planktonic bacteria by the a...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02738539

    authors: Qian Z,Sagers RD,Pitt WG

    更新日期:1997-01-01 00:00:00

  • Investigating the relationship between fetus EEG, respiratory, and blood pressure signals during maturation using wavelet transform.

    abstract::In this study, we introduce the fast wavelet transform as a method for characterizing maturational changes in electrocortical activity, respiratory activity, and blood pressure in fetal lambs in early (110-122 days), mid (123-135 days), and late (136-144 days) third trimester (term 145 days). Each recording was 2 hr i...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02584457

    authors: Akay M,Szeto HH

    更新日期:1995-09-01 00:00:00

  • Development of a device for measuring adherence of skin grafts to the wound surface.

    abstract::Adherence of a biological graft to the wound surface is the most important factor influencing the ultimate success of graft viability. A machine has been developed to test the adherence of biological graft materials to a substrate such as a wound surface. The peeling mode, which yields reproducible quantitative measur...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02368164

    authors: Dong C,Mead E,Skalak R,Fung YC,Debes JC,Zapata-Sirvent RL,Andree C,Greenleaf G,Cooper M,Hansbrough JF

    更新日期:1993-01-01 00:00:00

  • Pixel-Based DXA-Derived Structural Properties Strongly Correlate with pQCT Measures at the One-Third Distal Femur Site.

    abstract::While bone mineral density has been traditionally used to quantify fracture risk for individuals with spinal cord injuries, recent studies are including engineering measurements such as section modulus and cross sectional moment of inertia. These are almost exclusively calculated by peripheral QCT scanners which, unli...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-017-1796-6

    authors: Baker AM,Wagner DW,Kiratli BJ,Beaupre GS

    更新日期:2017-05-01 00:00:00

  • Nanoparticle deposition onto biofilms.

    abstract::We develop a mathematical model of nanoparticles depositing onto and penetrating into a biofilm grown in a parallel-plate flow cell. We carry out deposition experiments in a flow cell to support the modeling. The modeling and the experiments are motivated by the potential use of polymer nanoparticles as part of a trea...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-012-0626-0

    authors: Miller JK,Neubig R,Clemons CB,Kreider KL,Wilber JP,Young GW,Ditto AJ,Yun YH,Milsted A,Badawy HT,Panzner MJ,Youngs WJ,Cannon CL

    更新日期:2013-01-01 00:00:00

  • Fatigue of Metallic Stents: From Clinical Evidence to Computational Analysis.

    abstract::The great success of stents in treating cardiovascular disease is actually undermined by their long-term fatigue failure. The high variability of stent failure incidence suggests that it is due to several correlated aspects, such as loading conditions, material properties, component design, surgical procedure, and pat...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1447-8

    authors: Auricchio F,Constantinescu A,Conti M,Scalet G

    更新日期:2016-02-01 00:00:00

  • 3D Printing of Calcium Phosphate Ceramics for Bone Tissue Engineering and Drug Delivery.

    abstract::Additive manufacturing, also known as 3D printing, has emerged over the past 3 decades as a disruptive technology for rapid prototyping and manufacturing. Vat polymerization, powder bed fusion, material extrusion, and binder jetting are distinct technologies of additive manufacturing, which have been used in a wide va...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/s10439-016-1678-3

    authors: Trombetta R,Inzana JA,Schwarz EM,Kates SL,Awad HA

    更新日期:2017-01-01 00:00:00

  • Electrophysiological modeling of fibroblasts and their interaction with myocytes.

    abstract::Experimental studies have shown that cardiac fibroblasts are electrically inexcitable, but can contribute to electrophysiology of myocardium in various manners. The aim of this computational study was to give insights in the electrophysiological role of fibroblasts and their interaction with myocytes. We developed a m...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-007-9405-8

    authors: Sachse FB,Moreno AP,Abildskov JA

    更新日期:2008-01-01 00:00:00

  • Intelligent self-tuning of PID control for the robotic testing system for human musculoskeletal joints test.

    abstract::In this paper, an intelligent proportional-integral-derivative (PID) control method is introduced to the robotic testing system for the biomechanical study of human musculoskeletal joints. For the testing system, the robot is a highly nonlinear and heavily coupled complicated system, and the human spinal specimen also...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1023/b:abme.0000030759.80354.e8

    authors: Tian L

    更新日期:2004-06-01 00:00:00

  • Digital processing of the current noise evoked by kainate in cerebellar granule cells.

    abstract::Current induced in cultured cerebellar granule cells by the bath application of kainate (500 microM) was measured using the conventional patch-clamp technique. Two different kinds of responses were observed after the agonist perfusion. Some cells exhibited small inward whole-cell currents: 116 +/- 40 pA (7 cells) at a...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02684186

    authors: Cavalcanti S,Zona C

    更新日期:1997-05-01 00:00:00

  • Sustained Efficacy and Arterial Drug Retention by a Fast Drug Eluting Cross-Linked Fatty Acid Coronary Stent Coating.

    abstract::The long held assumption that sustained drug elution from stent coatings over weeks to months is imperative for clinical efficacy has limited the choice for stent coating materials. We developed and evaluated an omega-3 fatty acid (O3FA) based stent coating that is 85% absorbed and elutes 97% of its Sirolimus analog (...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1435-z

    authors: Artzi N,Tzafriri AR,Faucher KM,Moodie G,Albergo T,Conroy S,Corbeil S,Martakos P,Virmani R,Edelman ER

    更新日期:2016-02-01 00:00:00

  • An artificial neural network approach to the predictive modeling of tensile force during renal suturing.

    abstract::Further understanding of the mechanical deformation and tear behavior of kidney during suturing helps to enhance surgical task execution that requires fine suture manipulation. This paper aims to develop a model to describe the relationship between the tensile force acting on suture line and the resulted kidney deform...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-012-0722-1

    authors: Yu D,Qing Y,Jianxun Z,Jun D

    更新日期:2013-04-01 00:00:00

  • Partial Bone Formation in Additive Manufactured Porous Implants Reduces Predicted Stress and Danger of Fatigue Failure.

    abstract::New porous implant designs made possible by additive manufacturing allow for increased osseointegration, potentially improving implant performance and longevity for patients that require massive bone implants. The aim of this study was to evaluate how implantation and the strain distribution in the implant affect the ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-019-02369-z

    authors: Cheong VS,Fromme P,Coathup MJ,Mumith A,Blunn GW

    更新日期:2020-01-01 00:00:00

  • Behavior of human mesenchymal stem cells in fibrin-based vascular tissue engineering constructs.

    abstract::A limitation of current tissue engineering vascular graft technology is the provision of an expandable, autologous cell source. By harnessing the multipotency of mesenchymal stem cells (MSC), it is hoped that functional vascular cells can be produced. To date, a range of 2D and 3D environments have been investigated f...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-9912-x

    authors: O'Cearbhaill ED,Murphy M,Barry F,McHugh PE,Barron V

    更新日期:2010-03-01 00:00:00

  • Effects of hydration and fixed charge density on fluid transport in charged hydrated soft tissues.

    abstract::The effects of tissue hydration and fixed charge density on hydraulic permeability and creep behavior of cartilaginous tissues have been investigated using the triphasic theory and finite element methods. The empirical model for hydraulic permeability of uncharged gels and Mackie and Meares (1955) model for ion diffus...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1615576

    authors: Gu WY,Yao H

    更新日期:2003-11-01 00:00:00

  • Use of pseudorandom noise in studies of auditory evoked potentials.

    abstract::The extent to which sensorineural systems such as the auditory system are nonlinear depends on the type of stimulus that is used, and the part of the system from which recordings are made. An estimate of the first-order Wiener kernel of the evoked response from the inferior colliculus to amplitude-modulated tones and ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02367379

    authors: Møller AR,Angelo RM

    更新日期:1988-01-01 00:00:00

  • Effects of Hollow Fiber Membrane Oscillation on an Artificial Lung.

    abstract::Gas transfer through hollow fiber membranes (HFMs) can be increased via fiber oscillation. Prior work, however, does not directly translate to present-day, full-scale artificial lungs. This in vitro study characterized the effects of HFM oscillations on oxygenation and hemolysis for a pediatric-sized HFM bundle. Effec...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-018-1995-9

    authors: Orizondo RA,Gino G,Sultzbach G,Madhani SP,Frankowski BJ,Federspiel WJ

    更新日期:2018-05-01 00:00:00

  • Skull flexure as a contributing factor in the mechanism of injury in the rat when exposed to a shock wave.

    abstract::The manner in which energy from an explosion is transmitted into the brain is currently a highly debated topic within the blast injury community. This study was conducted to investigate the injury biomechanics causing blast-related neurotrauma in the rat. Biomechanical responses of the rat head under shock wave loadin...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-011-0343-0

    authors: Bolander R,Mathie B,Bir C,Ritzel D,VandeVord P

    更新日期:2011-10-01 00:00:00

  • Mechanisms of interstitial flow-induced remodeling of fibroblast-collagen cultures.

    abstract::Interstitial fluid flow, critical for macromolecular transport, was recently shown to drive fibroblast differentiation and perpendicular cell and matrix alignment in 3D collagen cultures. Here we explore the mechanisms underlying this flow-induced cell and collagen alignment. Cell and matrix alignment was assessed fro...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-005-9067-3

    authors: Ng CP,Swartz MA

    更新日期:2006-03-01 00:00:00

  • Analog electrical model of the coronary circulation in case of multiple revascularizations.

    abstract::In this work, we propose an analog electrical model of the coronary circulation for patients with obstructive disease undergoing revascularization. In this clinical situation, the collateral circulation to the occluded artery is difficult to ascertain via preoperative measurements and well-developed collaterals might ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-008-9500-5

    authors: Maasrani M,Verhoye JP,Corbineau H,Drochon A

    更新日期:2008-07-01 00:00:00

  • Regional distribution of aerosol deposition in rat lungs using magnetic resonance imaging.

    abstract::The toxic or therapeutic effect of an inhaled aerosol is highly dependent upon the site and extent of deposition in the lung. A novel MRI-based method was used to quantify the spatial distribution of particles in the rat lung. Rats were exposed to 0.95 μm-diameter iron oxide particles in a controlled manner (N = 6) or...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-013-0745-2

    authors: Oakes JM,Scadeng M,Breen EC,Prisk GK,Darquenne C

    更新日期:2013-05-01 00:00:00

  • Aortic Valve Function Under Support of a Left Ventricular Assist Device: Continuous vs. Dynamic Speed Support.

    abstract::Continuous flow left ventricular devices (CF-LVADs) support the failing heart at a constant speed and alters the loads on the aortic valve. This may cause insufficiency in the aortic valve under long-term CF-LVAD support. The aim of this study is to assess the aortic valve function under varying speed CF-LVAD support....

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-014-1204-4

    authors: Bozkurt S,van de Vosse FN,Rutten MC

    更新日期:2015-08-01 00:00:00

  • Particle motion within in vitro models of stenosed internal carotid and left anterior descending coronary arteries.

    abstract::Asymmetric 75% and 95% area reduction, transparent Sylgard stenotic models were operated under internal carotid artery (ICA) [Womersley parameter, alpha=5.36, Re(mean) =213 and 180, respectively, and Re(peak)=734 and 410, respectively] and left anterior descending coronary artery (LAD) flow wave forms (alpha=2.65, Re(...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.131

    authors: Cao J,Rittgers SE

    更新日期:1998-03-01 00:00:00

  • The effects of anisotropy on the stress analyses of patient-specific abdominal aortic aneurysms.

    abstract::The local dilation of the infrarenal abdominal aorta, termed an abdominal aortic aneurysm (AAA), is often times asymptomatic and may eventually result in rupture-an event associated with a significant mortality rate. The estimation of in-vivo stresses within AAAs has been proposed as a useful tool to predict the likel...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-008-9490-3

    authors: Vande Geest JP,Schmidt DE,Sacks MS,Vorp DA

    更新日期:2008-06-01 00:00:00

  • Computational study of proteolysis-driven single cell migration in a three-dimensional matrix.

    abstract::Cell migration is a fundamental process that is crucial to a variety of physiological events. While traditional approaches have focused on two-dimensional (2D) systems, recent efforts have shifted to studying migration in three-dimensional (3D) matrices. A major distinction that has emerged is the increased importance...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-9970-0

    authors: Harjanto D,Zaman MH

    更新日期:2010-05-01 00:00:00

  • Biomechanical properties of esophagus during systemic treatment with epidermal growth factor in rats.

    abstract::The epidermal growth factor (EGF) is a growth factor with effects on many cell types and tissue. Morphometric and passive biomechanical properties were studied in isolated segments of the esophagus in 22 EGF-treated rats and 12 control rats. The rats were divided into groups with EGF treatment for 2, 4, 7, and 14 days...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1575758

    authors: Zhao J,Yang J,Vinter-Jensen L,Zhuang F,Gregersen H

    更新日期:2003-06-01 00:00:00

  • Influence of autoregressive model parameter uncertainty on spectral estimates of heart rate dynamics.

    abstract::Linear autoregressive (AR) model-based heart rate (HR) spectral analysis has been widely used to study HR dynamics. Owing to system and measurement noise, the parameters of an AR model have intrinsic statistical uncertainty. In this study, we evaluate how this AR parameter uncertainty can translate to uncertainty in H...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02368320

    authors: Christini DJ,Kulkarni A,Rao S,Stutman ER,Bennett FM,Hausdorff JM,Oriol N,Lutchen KR

    更新日期:1995-03-01 00:00:00

  • Simultaneous Measurement of Contraction and Calcium Transients in Stem Cell Derived Cardiomyocytes.

    abstract::Induced pluripotent stem cell derived cardiomyocytes (iPSC-CM) provide a powerful platform for disease modeling and drug development in vitro. Traditionally, electrophysiological methods or fluorescent dyes (e.g. calcium) have been used in their functional characterization. Recently, video microscopy has enabled non-i...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-017-1933-2

    authors: Ahola A,Pölönen RP,Aalto-Setälä K,Hyttinen J

    更新日期:2018-01-01 00:00:00

  • Quantitative Validation of a Human Body Finite Element Model Using Rigid Body Impacts.

    abstract::Validation is a critical step in finite element model (FEM) development. This study focuses on the validation of the Global Human Body Models Consortium full body average male occupant FEM in five localized loading regimes-a chest impact, a shoulder impact, a thoracoabdominal impact, an abdominal impact, and a pelvic ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1286-7

    authors: Vavalle NA,Davis ML,Stitzel JD,Gayzik FS

    更新日期:2015-09-01 00:00:00