Low Impedance Carbon Adhesive Electrodes with Long Shelf Life.

Abstract:

:A novel electrocardiogram (ECG) electrode film is developed by mixing carbon black powder and a quaternary salt with a visco-elastic polymeric adhesive. Unlike traditional wet gel-based electrodes, carbon/salt/adhesive (CSA) electrodes should theoretically have an infinite shelf life as they do not dehydrate even after a prolonged period of storage. The CSA electrodes are electrically activated for use through the process of electrophoresis. Specifically, the activation procedure involves sending a high voltage and current through the electrode, which results in significant reduction of impedance so that high fidelity ECG signals can be obtained. Using the activation procedure, the ideal concentration of carbon black powder in the mixture with the adhesive was examined. It was determined that the optimum concentration of carbon black which minimized post-activation impedance was 10%. Once the optimal carbon black powder concentration was determined, extensive signal analysis was performed to compare the performance of the CSA electrodes to the standard silver-silver chloride (Ag/AgCl) electrodes. As a part of data analysis, electrode-skin contact impedance of the CSA was measured and compared to the standard Ag/AgCl electrodes; we found consistently lower impedance for CSA electrodes. For quantitative data analysis, we simultaneously collected ECG data with CSA and Ag/AgCl electrodes from 17 healthy subjects. Heart rate variability (HRV) indices and ECG morphological waveforms were calculated to compare CSA and Ag/AgCl electrodes. Non-significant differences for most of the HRV indices between CSA and Ag/AgCl electrodes were found. Of the morphological waveform metrics consisting of R-wave peak amplitude, ST-segment elevation and QT interval, only the first index was found to be significantly different between the two media. The response of CSA electrodes to motion artifacts was also tested, and we found in general no difference in the quality of the ECG signal between the two media. Hence, given that CSA electrodes are expected to have a very long shelf-life, with potentially less cost associated with their fabrication, and have ECG signal dynamics nearly identical to those of Ag/AgCl, the new electrodes provide an attractive alternative for ECG measurements.

journal_name

Ann Biomed Eng

authors

Posada-Quintero HF,Reyes BA,Burnham K,Pennace J,Chon KH

doi

10.1007/s10439-015-1282-y

subject

Has Abstract

pub_date

2015-10-01 00:00:00

pages

2374-82

issue

10

eissn

0090-6964

issn

1573-9686

pii

10.1007/s10439-015-1282-y

journal_volume

43

pub_type

杂志文章
  • Flow visualization in mechanical heart valves: occluder rebound and cavitation potential.

    abstract::High density particle image velocimetry, with spatial resolution of O(1 mm), was used to measure the effect of occluder rebound on the flow field near a Bjork-Shiley Monostrut tilting-disk mitral valve. The ability to measure two velocity components over an entire plane simultaneously provides a very different insight...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.281

    authors: Kini V,Bachmann C,Fontaine A,Deutsch S,Tarbell JM

    更新日期:2000-04-01 00:00:00

  • Passive-dynamic ankle-foot orthoses substitute for ankle strength while causing adaptive gait strategies: a feasibility study.

    abstract::Bending stiffness of passive-dynamic ankle-foot orthoses (PD-AFOs) is a functional characteristic thought to restore lost ankle function due to weakened plantar flexors. However, lower extremity impairment profiles of patients are seldom limited to plantar flexion weakness, and PD-AFO characteristics often influence g...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-014-1067-8

    authors: Arch ES,Stanhope SJ

    更新日期:2015-02-01 00:00:00

  • Masquelet Technique: Effects of Spacer Material and Micro-topography on Factor Expression and Bone Regeneration.

    abstract::We and others have shown that changing surface characteristics of the spacer implanted during the first Masquelet stage alters some aspects of membrane development. Previously we demonstrated that titanium (TI) spacers create membranes that are better barriers to movement of solutes > 70 kDa in size than polymethyl me...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-018-02137-5

    authors: Toth Z,Roi M,Evans E,Watson JT,Nicolaou D,McBride-Gagyi S

    更新日期:2019-01-01 00:00:00

  • Importance of temperature and humidity in the measurement of pulmonary oxygen uptake per breath during anesthesia.

    abstract::Traditionally, measurement of pulmonary O2 uptake uses mass balance of N2 to correct for differences between inspired and expired volume (V) due to temperature (T) and relative humidity (RH). Often during anesthesia, N2 balance cannot be invoked due to high inspired O2 fraction (FIO2) or nonsteady state conditions. Th...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1312184

    authors: Breen PH

    更新日期:2000-09-01 00:00:00

  • A piconewton force transducer and its application to measurement of the bending stiffness of phospholipid membranes.

    abstract::The bending stiffness of a phospholipid bilayer (Kc) was measured by forming thin bilayer cylinders (tethers) from giant phospholipid vesicles. Based on the balance of forces, the tether force was expected to be proportional to the square root of the membrane tension, with a constant of proportionality containing Kc. ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02684228

    authors: Heinrich V,Waugh RE

    更新日期:1996-09-01 00:00:00

  • Role of Rac and Rho-GDI alpha in the frequency-dependent expression of h1-calponin in vascular smooth muscle cells under cyclic mechanical strain.

    abstract::Phenotype transformation of vascular smooth muscle cells (VSMCs) has been reported to be directly influenced by the frequency of mechanical strain. This study explored the effects of different frequencies of mechanical strain on expression of phenotype marker h1-calponin and the possible mechanism. VSMCs were subjecte...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-008-9521-0

    authors: Qu MJ,Liu B,Qi YX,Jiang ZL

    更新日期:2008-09-01 00:00:00

  • Functionalized biomicroelectromechanical systems sensors for force response study at local adhesion sites of single living cells on substrates.

    abstract::We present a method of measuring force response of a single living cell, attached to a substrate, in situ, by a functionalized microelectromechanical systems sensor that applies local deformation on the cell. The sensor is a single crystal silicon microcantilever beam with prescribed shape and geometry, and is coated ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1591189

    authors: Saif MT,Sager CR,Coyer S

    更新日期:2003-09-01 00:00:00

  • Finite element modeling of coupled diffusion with partitioning in transdermal drug delivery.

    abstract::The finite element method is employed to simulate two-dimensional (axisymmetric) drug diffusion from a finite drug reservoir into the skin. The numerical formulation is based on a general mathematical model for multicomponent nonlinear diffusion that takes into account the coupling effects between the different compon...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-005-5788-6

    authors: Rim JE,Pinsky PM,van Osdol WW

    更新日期:2005-10-01 00:00:00

  • Investigating the influence of haemodynamic stimuli on intracranial aneurysm inception.

    abstract::We propose a novel method to reconstruct the hypothetical geometry of the healthy vasculature prior to intracranial aneurysm (IA) formation: a Frenet frame is calculated along the skeletonization of the arterial geometry; upstream and downstream boundaries of the aneurysmal segment are expressed in terms of the local ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-013-0794-6

    authors: Chen H,Selimovic A,Thompson H,Chiarini A,Penrose J,Ventikos Y,Watton PN

    更新日期:2013-07-01 00:00:00

  • Modeling Human Volunteers in Multidirectional, Uni-axial Sled Tests Using a Finite Element Human Body Model.

    abstract::A goal of the Human Research Program at National Aeronautics and Space Administration (NASA) is to analyze and mitigate the risk of occupant injury due to dynamic loads. Experimental tests of human subjects and biofidelic anthropomorphic test devices provide valuable kinematic and kinetic data related to injury risk e...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-018-02147-3

    authors: Gaewsky JP,Jones DA,Ye X,Koya B,McNamara KP,Gayzik FS,Weaver AA,Putnam JB,Somers JT,Stitzel JD

    更新日期:2019-02-01 00:00:00

  • Countercurrent extraction of sparingly soluble gases for membrane introduction mass spectrometry.

    abstract::Membrane introduction mass spectrometry has been applied to inert gas measurements in blood and tissue, but gases with low blood solubility are associated with reduced sensitivity. Countercurrent extraction of inert gases from a blood sample into a water carrier phase has the potential to extract most of the gas sampl...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02684170

    authors: Baumgardner JE,Neufeld GR

    更新日期:1997-09-01 00:00:00

  • Interaction between high frequency jet ventilation and cardiovascular function.

    abstract::We have studied the interaction of high frequency jet ventilation with cardiovascular pressures and flows. Results in dogs show that the amplitude of all intrathoracic pressures and flows fluctuate with a frequency equal to the difference between the heart rate and ventilator rate. The magnitude of this amplitude vari...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02584287

    authors: Mitzner W,Gioia F,Weinmann GG,Robotham JL,Ehrlich W

    更新日期:1987-01-01 00:00:00

  • Mechanical behavior of excised canine visceral pleura.

    abstract::A computer-controlled optical electromechanical biaxial test system was employed to study the mechanical response of excised sheets of canine visceral pleura. Three classes of tests were performed: uniform biaxial stretching tests and tests in which the specimen was cyclically stretched along one axis while either the...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02367365

    authors: Humphrey JD,Vawter DL,Vito RP

    更新日期:1986-01-01 00:00:00

  • An experimental and numerical investigation of head dynamics due to stick impacts in girls' lacrosse.

    abstract::A method of investigating head acceleration and intracranial dynamics from stick impacts in girls' and women's lacrosse was developed using headform impact experiments and a finite element head model. Assessing the likelihood of head injury due to stick-head impacts is of interest in girls' and women's lacrosse due to...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-014-1091-8

    authors: Morse JD,Franck JA,Wilcox BJ,Crisco JJ,Franck C

    更新日期:2014-12-01 00:00:00

  • Cardiac Multi-detector CT Segmentation Based on Multiscale Directional Edge Detector and 3D Level Set.

    abstract::Extraction of the cardiac surfaces of interest from multi-detector computed tomographic (MDCT) data is a pre-requisite step for cardiac analysis, as well as for image guidance procedures. Most of the existing methods need manual corrections, which is time-consuming. We present a fully automatic segmentation technique ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,随机对照试验

    doi:10.1007/s10439-015-1422-4

    authors: Antunes S,Esposito A,Palmisano A,Colantoni C,Cerutti S,Rizzo G

    更新日期:2016-05-01 00:00:00

  • Fatigue of Metallic Stents: From Clinical Evidence to Computational Analysis.

    abstract::The great success of stents in treating cardiovascular disease is actually undermined by their long-term fatigue failure. The high variability of stent failure incidence suggests that it is due to several correlated aspects, such as loading conditions, material properties, component design, surgical procedure, and pat...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1447-8

    authors: Auricchio F,Constantinescu A,Conti M,Scalet G

    更新日期:2016-02-01 00:00:00

  • Fecobionics: A Novel Bionics Device for Studying Defecation.

    abstract::During defecation, solid, semisolid or liquid stools are eliminated via the anus in a complex physiological process. Up to 25% of the population are affected by anorectal disorders that are poorly recognized and treated. We developed a new bionics device, a simulated stool named Fecobionics, to replace several current...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-018-02149-1

    authors: Sun D,Huang Z,Zhuang Z,Ma Z,Man LK,Liao D,Gregersen H

    更新日期:2019-02-01 00:00:00

  • A COVID-19 Airway Management Innovation with Pragmatic Efficacy Evaluation: The Patient Particle Containment Chamber.

    abstract::The unique resource constraints, urgency, and virulence of the coronavirus disease 2019 pandemic has sparked immense innovation in the development of barrier devices to protect healthcare providers from infectious airborne particles generated by patients during airway management interventions. Of the existing devices,...

    journal_title:Annals of biomedical engineering

    pub_type: 社论

    doi:10.1007/s10439-020-02599-6

    authors: Maloney LM,Yang AH,Princi RA,Eichert AJ,Hébert DR,Kupec TV,Mertz AE,Vasyltsiv R,Vijaya Kumar TM,Walker GJ,Peralta EJ,Hoffman JL,Yin W,Page CR

    更新日期:2020-10-01 00:00:00

  • Skull flexure as a contributing factor in the mechanism of injury in the rat when exposed to a shock wave.

    abstract::The manner in which energy from an explosion is transmitted into the brain is currently a highly debated topic within the blast injury community. This study was conducted to investigate the injury biomechanics causing blast-related neurotrauma in the rat. Biomechanical responses of the rat head under shock wave loadin...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-011-0343-0

    authors: Bolander R,Mathie B,Bir C,Ritzel D,VandeVord P

    更新日期:2011-10-01 00:00:00

  • Pixel-Based DXA-Derived Structural Properties Strongly Correlate with pQCT Measures at the One-Third Distal Femur Site.

    abstract::While bone mineral density has been traditionally used to quantify fracture risk for individuals with spinal cord injuries, recent studies are including engineering measurements such as section modulus and cross sectional moment of inertia. These are almost exclusively calculated by peripheral QCT scanners which, unli...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-017-1796-6

    authors: Baker AM,Wagner DW,Kiratli BJ,Beaupre GS

    更新日期:2017-05-01 00:00:00

  • Intelligent self-tuning of PID control for the robotic testing system for human musculoskeletal joints test.

    abstract::In this paper, an intelligent proportional-integral-derivative (PID) control method is introduced to the robotic testing system for the biomechanical study of human musculoskeletal joints. For the testing system, the robot is a highly nonlinear and heavily coupled complicated system, and the human spinal specimen also...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1023/b:abme.0000030759.80354.e8

    authors: Tian L

    更新日期:2004-06-01 00:00:00

  • Chondrogenesis and integration of mesenchymal stem cells within an in vitro cartilage defect repair model.

    abstract::Integration of repair tissue is a key indicator of the long-term success of cell-based therapies for cartilage repair. The objective of this study was to compare the in vitro chondrogenic differentiation and integration of agarose hydrogels seeded with either chondrocytes or bone marrow-derived mesenchymal stem cells ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-009-9791-1

    authors: Vinardell T,Thorpe SD,Buckley CT,Kelly DJ

    更新日期:2009-12-01 00:00:00

  • Sensor Anchoring Improves the Correlation Between Intramuscular Pressure and Muscle Tension in a Rabbit Model.

    abstract::Intramuscular pressure (IMP) shows promise for estimating individual muscle tension in vivo. However, previous pressure measurements show high variability during isometric contraction and poor correlation with tension during dynamic contraction. We hypothesized that enhanced sensor anchoring/orientation would improve ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02633-7

    authors: O'Connor SM,Kaufman KR,Ward SR,Lieber RL

    更新日期:2021-02-01 00:00:00

  • An efficient technique for the numerical solution of the bidomain equations.

    abstract::Computing the numerical solution of the bidomain equations is widely accepted to be a significant computational challenge. In this study we extend a previously published semi-implicit numerical scheme with good stability properties that has been used to solve the bidomain equations (Whiteley, J.P. IEEE Trans. Biomed. ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-008-9513-0

    authors: Whiteley JP

    更新日期:2008-08-01 00:00:00

  • Effect of mechanical strain on solute diffusion in human TMJ discs: an electrical conductivity study.

    abstract::This study investigated the effect of mechanical strain on solute diffusion in human TMJ discs (mean cadaver age 77.8) using the electrical conductivity method. The electrical conductivity, as well as small ion diffusivity, of male and female TMJ discs was determined under three compressive strains. In the male group,...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-013-0840-4

    authors: Wright GJ,Kuo J,Shi C,Bacro TR,Slate EH,Yao H

    更新日期:2013-11-01 00:00:00

  • Analyzing trends in brain interface technology: a method to compare studies.

    abstract::Continued progress in the field of Brain Interface (BI) research has encouraged the rapid expansion of the BI community over the last two decades. As the number of BI researchers and organizations steadily increases, newer and more advanced technologies are constantly produced, evaluated, and reported. Though the BI c...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-005-9055-7

    authors: Jackson MM,Mason SG,Birch GE

    更新日期:2006-05-01 00:00:00

  • Personalized Perioperative Multi-scale, Multi-physics Heart Simulation of Double Outlet Right Ventricle.

    abstract::For treatment of complex congenital heart disease, computer simulation using a three-dimensional heart model may help to improve outcomes by enabling detailed preoperative evaluations. However, no highly integrated model that accurately reproduces a patient's pathophysiology, which is required for this simulation has ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02488-y

    authors: Kariya T,Washio T,Okada JI,Nakagawa M,Watanabe M,Kadooka Y,Sano S,Nagai R,Sugiura S,Hisada T

    更新日期:2020-06-01 00:00:00

  • Determination of mechanical properties of spatially heterogeneous breast tissue specimens using contact mode atomic force microscopy (AFM).

    abstract::This paper outlines a comprehensive parametric approach for quantifying mechanical properties of spatially heterogeneous thin biological specimens such as human breast tissue using contact-mode Atomic Force Microscopy. Using inverse finite element (FE) analysis of spherical nanoindentation, the force response from hyp...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-014-1057-x

    authors: Roy R,Desai JP

    更新日期:2014-09-01 00:00:00

  • Reproducing cardiac restitution properties using the Fenton-Karma membrane model.

    abstract::Modern models of cardiac membranes are often highly complex and computationally expensive, particularly when used in long simulations of spatially extended models of cardiac tissue. Therefore, there is a need for simpler membrane models that preserve the features of the complex models deemed important. This communicat...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-005-3948-3

    authors: Oliver RA,Krassowska W

    更新日期:2005-07-01 00:00:00

  • Bioengineering the skin-implant interface: the use of regenerative therapies in implanted devices.

    abstract::This discussion and review article focuses on the possible use of regenerative techniques applied to the interfaces between skin and medical implants. As is widely known, the area of contact between an implant and the skin--the skin-implant interface--is prone to recurrent and persistent problems originated from the l...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/s10439-010-9937-1

    authors: Peramo A,Marcelo CL

    更新日期:2010-06-01 00:00:00