Personalized Perioperative Multi-scale, Multi-physics Heart Simulation of Double Outlet Right Ventricle.

Abstract:

:For treatment of complex congenital heart disease, computer simulation using a three-dimensional heart model may help to improve outcomes by enabling detailed preoperative evaluations. However, no highly integrated model that accurately reproduces a patient's pathophysiology, which is required for this simulation has been reported. We modelled a case of complex congenital heart disease, double outlet right ventricle with ventricular septal defect and atrial septal defect. From preoperative computed tomography images, finite element meshes of the heart and torso were created, and cell model of cardiac electrophysiology and sarcomere dynamics was implemented. The parameter values of the heart model were adjusted to reproduce the patient's electrocardiogram and haemodynamics recorded preoperatively. Two options of in silico surgery were performed using this heart model, and the resulting changes in performance were examined. Preoperative and postoperative simulations showed good agreement with clinical records including haemodynamics and measured oxyhaemoglobin saturations. The use of a detailed sarcomere model also enabled comparison of energetic efficiency between the two surgical options. A novel in silico model of congenital heart disease that integrates molecular models of cardiac function successfully reproduces the observed pathophysiology. The simulation of postoperative state by in silico surgeries can help guide clinical decision-making.

journal_name

Ann Biomed Eng

authors

Kariya T,Washio T,Okada JI,Nakagawa M,Watanabe M,Kadooka Y,Sano S,Nagai R,Sugiura S,Hisada T

doi

10.1007/s10439-020-02488-y

subject

Has Abstract

pub_date

2020-06-01 00:00:00

pages

1740-1750

issue

6

eissn

0090-6964

issn

1573-9686

pii

10.1007/s10439-020-02488-y

journal_volume

48

pub_type

杂志文章
  • Fetal Transcatheter Trileaflet Heart Valve Hemodynamics: Implications of Scaling on Valve Mechanics and Turbulence.

    abstract::The scarcity of data available on the best approach for pulmonary fetal valve replacement or implantation necessitate an investigation on whether practices using adult transcatheter valves could be translated to fetal applications. The objective of this study is to evaluate the hemodynamic characteristics and the turb...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02475-3

    authors: Hatoum H,Gooden S,Heitkemper M,Blum KM,Zakko J,Bocks M,Yi T,Wu YL,Wang Y,Breuer CK,Dasi LP

    更新日期:2020-06-01 00:00:00

  • Validation of Shoulder Response of Human Body Finite-Element Model (GHBMC) Under Whole Body Lateral Impact Condition.

    abstract::In previous shoulder impact studies, the 50th-percentile male GHBMC human body finite-element model was shown to have good biofidelity regarding impact force, but under-predicted shoulder deflection by 80% compared to those observed in the experiment. The goal of this study was to validate the response of the GHBMC M5...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1546-6

    authors: Park G,Kim T,Panzer MB,Crandall JR

    更新日期:2016-08-01 00:00:00

  • Interstitial stress and fluid pressure within a growing tumor.

    abstract::A solid tumor is composed of a population of cells that is expanding as a result of cell division. With dense cell packing, the solid matrix of the interstitial tissue is subject to residual stress. In addition, elevated interstitial fluid pressure (IFP) has been reported by researchers for a number of solid tumors. T...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1554923

    authors: Sarntinoranont M,Rooney F,Ferrari M

    更新日期:2003-03-01 00:00:00

  • Electrical impedance cardiography using artificial neural networks.

    abstract::This study evaluates the use of artificial neural networks to estimate stroke volume from pre-processed, thoracic impedance plethysmograph signals from 20 healthy subjects. Standard back-propagation was used to train the networks, with Doppler stroke volume estimates as the desired output. The trained networks were th...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.47

    authors: Mulavara AP,Timmons WD,Nair MS,Gupta V,Kumar AA,Taylor BC

    更新日期:1998-07-01 00:00:00

  • Customised Selection of the Haptic Design in C-Loop Intraocular Lenses Based on Deep Learning.

    abstract::In order to increase the probability of having a successful cataract post-surgery, the customisation of the haptic design of the intraocular lens (IOL) according to the characteristics of the patient is recommended. In this study, we present two prediction models based on deep neural networks (DNNs). One is capable of...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02636-4

    authors: Cabeza-Gil I,Ríos-Ruiz I,Calvo B

    更新日期:2020-12-01 00:00:00

  • Binary segmentation masks can improve intrasubject registration accuracy of bone structures in CT images.

    abstract::Registration of bone structures is a common problem in medical research as well as in clinical applications. Intrasubject rigid 3D monomodality registration of segmented bone structures of CT images and multimodality registration of muMR and segmented muCT bone images were performed with the multiresolution intensity-...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-9981-x

    authors: Museyko O,Eisa F,Hess A,Schett G,Kalender WA,Engelke K

    更新日期:2010-07-01 00:00:00

  • A Novel Apparatus for the Multifaceted Evaluation of Arterial Function Through Transmural Pressure Manipulation.

    abstract::A novel apparatus for the multifaceted evaluation of artery function was developed. It measures endothelial and smooth muscle functions and the pressure-strain elastic modulus (E p). A rigid airtight chamber with an ultrasound probe was attached to the upper arm to manipulate the transmural pressure of the brachial ar...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-017-1810-z

    authors: Yaguchi T,Cong Y,Shimo K,Kurokawa T,Sugita S,Nagayama K,Masuda H,Matsumoto T

    更新日期:2017-06-01 00:00:00

  • Low Impedance Carbon Adhesive Electrodes with Long Shelf Life.

    abstract::A novel electrocardiogram (ECG) electrode film is developed by mixing carbon black powder and a quaternary salt with a visco-elastic polymeric adhesive. Unlike traditional wet gel-based electrodes, carbon/salt/adhesive (CSA) electrodes should theoretically have an infinite shelf life as they do not dehydrate even afte...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1282-y

    authors: Posada-Quintero HF,Reyes BA,Burnham K,Pennace J,Chon KH

    更新日期:2015-10-01 00:00:00

  • Automatic Model Generation Framework for Computational Simulation of Cochlear Implantation.

    abstract::Recent developments in computational modeling of cochlear implantation are promising to study in silico the performance of the implant before surgery. However, creating a complete computational model of the patient's anatomy while including an external device geometry remains challenging. To address such a challenge, ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1541-y

    authors: Mangado N,Ceresa M,Duchateau N,Kjer HM,Vera S,Dejea Velardo H,Mistrik P,Paulsen RR,Fagertun J,Noailly J,Piella G,González Ballester MÁ

    更新日期:2016-08-01 00:00:00

  • Concussion Risk Between Individual Football Players: Survival Analysis of Recurrent Events and Non-events.

    abstract::Concussion tolerance and head impact exposure are highly variable among football players. Recent findings highlight that head impact data analyses need to be performed at the subject level. In this paper, we describe a method of characterizing concussion risk between individuals using a new survival analysis technique...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02675-x

    authors: Rowson S,Campolettano ET,Duma SM,Stemper B,Shah A,Harezlak J,Riggen L,Mihalik JP,Brooks A,Cameron KL,Svoboda SJ,Houston MN,McAllister T,Broglio S,McCrea M

    更新日期:2020-11-01 00:00:00

  • Fluid flow-induced calcium response in early or late differentiated osteoclasts.

    abstract::Intracellular calcium oscillation caused by receptor activator of nuclear factor kappa-B ligand has been demonstrated to promote the differentiation of osteoclasts. Osteoclasts are recruited on the surface of trabeculae, and are exposed to fluid flow caused by the deformation of the bone matrix. However, the roles of ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-012-0554-z

    authors: Li P,Hu M,Sun S,Zhang Y,Gao Y,Long M,Huo B,Zhang D

    更新日期:2012-09-01 00:00:00

  • Are DXA/aBMD and QCT/FEA Stiffness and Strength Estimates Sensitive to Sex and Age?

    abstract::Dual X-ray absorptiometry (DXA) measures areal bone mineral density (aBMD) by simplifying a complex 3D bone structure to a 2D projection and is not equally effective for explaining fracture strength in women and men. Unlike DXA, subject-specific quantitative computed tomography-based finite element analysis (QCT/FEA) ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-017-1914-5

    authors: Rezaei A,Giambini H,Rossman T,Carlson KD,Yaszemski MJ,Lu L,Dragomir-Daescu D

    更新日期:2017-12-01 00:00:00

  • Parameter estimation for linear compartmental models--a sensitivity analysis approach.

    abstract::Linear compartmental models are useful, explanatory tools, that have been widely used to represent the dynamic behavior of complex biological systems. This paper addresses the problem of the numerical identification of such models, i.e., the estimation of the parameter values that will generate predictions closest to ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-009-9651-z

    authors: Juillet B,Bos C,Gaudichon C,Tomé D,Fouillet H

    更新日期:2009-05-01 00:00:00

  • Spectral analysis of Doppler flow velocity signals: assessment of objectives, methods, and interpretation.

    abstract::The objective of this paper is to review the theoretical basis and clinical application of electrical impedance plethysmography in the noninvasive evaluation of peripheral arterial and venous disease. Theoretical, experimental and clinical studies have not demonstrated a direct relationship between electrical impedanc...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02410294

    authors: Zuech PE,Cobbold RS,Johnston KW,Kassam M

    更新日期:1984-01-01 00:00:00

  • Conductance method for the measurement of cross-sectional areas of the aorta.

    abstract::A modified conductance method to determine the cross-sectional areas (CSAs) of arteries in piglets was evaluated in vivo. The method utilized a conductance catheter having four electrodes. Between the outer electrodes an alternating current was applied and between the inner electrodes the induced voltage difference wa...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.219

    authors: Kornet L,Jansen JR,Gussenhoven EJ,Hardeman MR,Hoeks AP,Versprille A

    更新日期:1999-03-01 00:00:00

  • Zonal uniformity in mechanical properties of the chondrocyte pericellular matrix: micropipette aspiration of canine chondrons isolated by cartilage homogenization.

    abstract::The pericellular matrix (PCM) is a region of tissue that surrounds chondrocytes in articular cartilage and together with the enclosed cells is termed the chondron. Previous studies suggest that the mechanical properties of the PCM, relative to those of the chondrocyte and the extracellular matrix (ECM), may significan...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-005-4479-7

    authors: Guilak F,Alexopoulos LG,Haider MA,Ting-Beall HP,Setton LA

    更新日期:2005-10-01 00:00:00

  • Tumor anti-angiogenic gene therapy with microencapsulated recombinant CHO cells.

    abstract::Microencapsulation of recombinant cells is a novel promising approach to tumor therapy in which therapeutic protein is sustainable and long-term delivered by microencapsulated cells. The semi-permeable membrane of microcapsule can protect cell from host's immune rejection, increase the chemical stability of therapeuti...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-007-9255-4

    authors: Zhang Y,Wang W,Zhou J,Yu W,Zhang X,Guo X,Ma X

    更新日期:2007-04-01 00:00:00

  • Micro-flow visualization of red blood cell-enhanced platelet concentration at sudden expansion.

    abstract::Microscopic steps and crevices are inevitable features within prosthetic blood-contacting devices. This study aimed to elucidate the thrombogenicity of the associated microscopic flow features by studying the transport of fluorescent platelet-sized particles in a suspension of red blood cells (RBCs) flowing through a ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-008-9494-z

    authors: Zhao R,Marhefka JN,Shu F,Hund SJ,Kameneva MV,Antaki JF

    更新日期:2008-07-01 00:00:00

  • An artificial neural network approach to the predictive modeling of tensile force during renal suturing.

    abstract::Further understanding of the mechanical deformation and tear behavior of kidney during suturing helps to enhance surgical task execution that requires fine suture manipulation. This paper aims to develop a model to describe the relationship between the tensile force acting on suture line and the resulted kidney deform...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-012-0722-1

    authors: Yu D,Qing Y,Jianxun Z,Jun D

    更新日期:2013-04-01 00:00:00

  • Phospholipids identified on the pericardium and their ability to impart boundary lubrication.

    abstract::Phospholipids have been identified by thin-layer chromatography in appreciable quantities in pericardial fluid taken from 12 dogs and found to include sphingomyelin and phosphatidylcholines, -ethanolamines, -inositols and -serines--the cholines predominating. The extracts, the synthetic surfactants and a mixture of sy...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02584258

    authors: Hills BA,Butler BD

    更新日期:1985-01-01 00:00:00

  • Biased cell migration of fibroblasts exhibiting contact guidance in oriented collagen gels.

    abstract::We present here the first quantitative correlation for cell contact guidance in an oriented fibrillar network in terms of biased cell migration. The correlation is between the anisotropic cell diffusion parameter, DA = Dx/Dy, and the collagen gel birefringence, delta n, a measure of axially biased collagen fibril orie...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02368241

    authors: Dickinson RB,Guido S,Tranquillo RT

    更新日期:1994-07-01 00:00:00

  • Gaussian pulse decomposition: an intuitive model of electrocardiogram waveforms.

    abstract::This study presents a novel approach to modeling the electrocardiogram (ECG): the Gaussian pulse decomposition. Constituent waves of the ECG are decomposed into and represented by Gaussian pulses using an iterative algorithm: the chip away decomposition (ChAD) algorithm. At each iteration, a nonlinear minimization met...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02648039

    authors: Suppappola S,Sun Y,Chiaramida SA

    更新日期:1997-03-01 00:00:00

  • Changes of flow characteristics by stenting in aneurysm models: influence of aneurysm geometry and stent porosity.

    abstract::An endovascular technique using a stent has been developed and successfully applied in the treatment of wide neck aneurysms. A stent can facilitate thrombosis in the aneurysm pouch while maintaining biocompatible passage of the parent artery. Insertion of the stent changes the flow characteristics inside the aneurysm ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1500406

    authors: Rhee K,Han MH,Cha SH

    更新日期:2002-07-01 00:00:00

  • A single equivalent moving dipole model: an efficient approach for localizing sites of origin of ventricular electrical activation.

    abstract::We propose a new method for guiding catheter ablation procedures to abolish sites of origin of arrhythmias. This method models both cardiac electrical activity and current pulses delivered from the tip of the ablation catheter with a single equivalent moving dipole (SEMD). The SEMD parameters are obtained from analysi...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1567281

    authors: Armoundas AA,Feldman AB,Mukkamala R,Cohen RJ

    更新日期:2003-05-01 00:00:00

  • High fidelity virtual stenting (HiFiVS) for intracranial aneurysm flow diversion: in vitro and in silico.

    abstract::A flow diverter (FD) is a flexible, densely braided stent-mesh device placed endoluminally across an intracranial aneurysm to induce its thrombotic occlusion. FD treatment planning using computational virtual stenting and flow simulation requires accurate representation of the expanded FD geometry. We have recently de...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-013-0808-4

    authors: Ma D,Dumont TM,Kosukegawa H,Ohta M,Yang X,Siddiqui AH,Meng H

    更新日期:2013-10-01 00:00:00

  • Constitutive modeling of rate-dependent stress-strain behavior of human liver in blunt impact loading.

    abstract::An understanding of the mechanical deformation behavior of the liver under high strain rate loading conditions could aid in the development of vehicle safety measures to reduce the occurrence of blunt liver injury. The purpose of this study was to develop a constitutive model of the stress-strain behavior of the human...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-008-9555-3

    authors: Sparks JL,Dupaix RB

    更新日期:2008-11-01 00:00:00

  • Mechanics Reveals the Biological Trigger in Wrinkly Fingers.

    abstract::Fingertips wrinkle due to long exposure to water. The biological reason for this morphological change is unclear and still not fully understood. There are two main hypotheses for the underlying mechanism of fingertip wrinkling: the 'shrink' model (in which the wrinkling is driven by the contraction of the lower layers...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-016-1764-6

    authors: Sáez P,Zöllner AM

    更新日期:2017-04-01 00:00:00

  • In vitro temperature map of cardiac ablation demonstrates the effect of flow on lesion development.

    abstract::This paper presents an in vitro temperature mapping study of bovine cardiac tissue during radiofrequency ablation. The objectives were to: (i) develop a technique for measuring the spatial and temporal temperature distribution in the tissue and in the blood during ablation, and (ii) use the temperature measurements to...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1310218

    authors: Jain MK,Wolf PD

    更新日期:2000-09-01 00:00:00

  • Hemodynamic Influence on Smooth Muscle Cell Kinetics and Phenotype During Early Vein Graft Adaptation.

    abstract::Pathologic vascular adaptation following local injury is the primary driver for accelerated intimal hyperplasia and an occlusive phenotype. Smooth muscle cell (SMC) proliferation within the wall, and migration into the developing intima, is a major component of this remodeling response. The primary objective in the cu...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-016-1725-0

    authors: Klein B,Destephens A,Dumeny L,Hu Q,He Y,O'Malley K,Jiang Z,Tran-Son-Tay R,Berceli S

    更新日期:2017-03-01 00:00:00

  • Computational approach to estimating the effects of blood properties on changes in intra-stent flow.

    abstract::In this study various blood rheological assumptions are numerically investigated for the hemodynamic properties of intra-stent flow. Non-newtonian blood properties have never been implemented in blood coronary stented flow investigation, although its effects appear essential for a correct estimation and distribution o...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-006-9123-7

    authors: Benard N,Perrault R,Coisne D

    更新日期:2006-08-01 00:00:00