Validation of Shoulder Response of Human Body Finite-Element Model (GHBMC) Under Whole Body Lateral Impact Condition.

Abstract:

:In previous shoulder impact studies, the 50th-percentile male GHBMC human body finite-element model was shown to have good biofidelity regarding impact force, but under-predicted shoulder deflection by 80% compared to those observed in the experiment. The goal of this study was to validate the response of the GHBMC M50 model by focusing on three-dimensional shoulder kinematics under a whole-body lateral impact condition. Five modifications, focused on material properties and modeling techniques, were introduced into the model and a supplementary sensitivity analysis was done to determine the influence of each modification to the biomechanical response of the body. The modified model predicted substantially improved shoulder response and peak shoulder deflection within 10% of the observed experimental data, and showed good correlation in the scapula kinematics on sagittal and transverse planes. The improvement in the biofidelity of the shoulder region was mainly due to the modifications of material properties of muscle, the acromioclavicular joint, and the attachment region between the pectoralis major and ribs. Predictions of rib fracture and chest deflection were also improved because of these modifications.

journal_name

Ann Biomed Eng

authors

Park G,Kim T,Panzer MB,Crandall JR

doi

10.1007/s10439-015-1546-6

subject

Has Abstract

pub_date

2016-08-01 00:00:00

pages

2558-2576

issue

8

eissn

0090-6964

issn

1573-9686

pii

10.1007/s10439-015-1546-6

journal_volume

44

pub_type

杂志文章
  • Design and hydrodynamic evaluation of a novel pulsatile bioreactor for biologically active heart valves.

    abstract::Biologically active heart valves (tissue engineered and recellularized tissue-derived heart valves) have the potential to offer enhanced function when compared to current replacement value therapies since they can possibly remodel, and grow to meet the needs of the patient, and not require chronic medication. However,...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/b:abme.0000036640.11387.4b

    authors: Hildebrand DK,Wu ZJ,Mayer JE Jr,Sacks MS

    更新日期:2004-08-01 00:00:00

  • A Novel Parameter for Predicting Arterial Fusion and Cutting in Finite Element Models.

    abstract::Current efforts to evaluate the performance of laparoscopic arterial fusion devices are limited to costly, time consuming, empirical studies. Thus, a finite element (FE) model, with the ability to predict device performance would improve device design and reduce development time and costs. This study introduces a mode...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-016-1588-4

    authors: Fankell DP,Kramer E,Cezo J,Taylor KD,Ferguson VL,Rentschler ME

    更新日期:2016-11-01 00:00:00

  • High fidelity virtual stenting (HiFiVS) for intracranial aneurysm flow diversion: in vitro and in silico.

    abstract::A flow diverter (FD) is a flexible, densely braided stent-mesh device placed endoluminally across an intracranial aneurysm to induce its thrombotic occlusion. FD treatment planning using computational virtual stenting and flow simulation requires accurate representation of the expanded FD geometry. We have recently de...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-013-0808-4

    authors: Ma D,Dumont TM,Kosukegawa H,Ohta M,Yang X,Siddiqui AH,Meng H

    更新日期:2013-10-01 00:00:00

  • Effect of Subject-Specific Vertebral Position and Head and Neck Size on Calculation of Spine Musculoskeletal Moments.

    abstract::Spine musculoskeletal models used to estimate loads and displacements require many simplifying assumptions. We examined how assumptions about subject size and vertebral positions can affect the model outcomes. Head and neck models were developed to represent 30 subjects (15 males and 15 females) in neutral posture and...

    journal_title:Annals of biomedical engineering

    pub_type: 临床试验,杂志文章

    doi:10.1007/s10439-018-2084-9

    authors: Vasavada AN,Hughes E,Nevins DD,Monda SM,Lin DC

    更新日期:2018-11-01 00:00:00

  • MEG connectivity analysis in patients with Alzheimer's disease using cross mutual information and spectral coherence.

    abstract::Alzheimer's disease (AD) is an irreversible brain disorder which represents the most common form of dementia in western countries. An early and accurate diagnosis of AD would enable to develop new strategies for managing the disease; however, nowadays there is no single test that can accurately predict the development...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-0155-7

    authors: Alonso JF,Poza J,Mañanas MA,Romero S,Fernández A,Hornero R

    更新日期:2011-01-01 00:00:00

  • Micro-computed tomography based computational fluid dynamics for the determination of shear stresses in scaffolds within a perfusion bioreactor.

    abstract::Perfusion bioreactors are known to exert shear stresses on cultured cells, leading to cell differentiation and enhanced extracellular matrix deposition on scaffolds. The influence of the scaffold's porous microstructure is investigated for a polycaprolactone (PCL) scaffold with a regular microarchitecture and a silk f...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-014-0981-0

    authors: Zermatten E,Vetsch JR,Ruffoni D,Hofmann S,Müller R,Steinfeld A

    更新日期:2014-05-01 00:00:00

  • Biofluid mechanics of special organs and the issue of system control. Sixth International Bio-Fluid Mechanics Symposium and Workshop, March 28-30, 2008 Pasadena, California.

    abstract::In the field of fluid flow within the human body, focus has been placed on the transportation of blood in the systemic circulation since the discovery of that system; but, other fluids and fluid flow phenomena pervade the body. Some of the most fascinating fluid flow phenomena within the human body involve fluids othe...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-9902-z

    authors: Zamir M,Moore JE Jr,Fujioka H,Gaver DP 3rd

    更新日期:2010-03-01 00:00:00

  • Personalized Perioperative Multi-scale, Multi-physics Heart Simulation of Double Outlet Right Ventricle.

    abstract::For treatment of complex congenital heart disease, computer simulation using a three-dimensional heart model may help to improve outcomes by enabling detailed preoperative evaluations. However, no highly integrated model that accurately reproduces a patient's pathophysiology, which is required for this simulation has ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02488-y

    authors: Kariya T,Washio T,Okada JI,Nakagawa M,Watanabe M,Kadooka Y,Sano S,Nagai R,Sugiura S,Hisada T

    更新日期:2020-06-01 00:00:00

  • Off-line and on-line stress detection through processing of the pupil diameter signal.

    abstract::The pupil diameter (PD), controlled by the autonomic nervous system, seems to provide a strong indication of affective arousal, as found by previous research, but it has not been investigated fully yet. In this study, new approaches based on monitoring and processing the PD signal for off-line and on-line "relaxation"...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-013-0880-9

    authors: Ren P,Barreto A,Huang J,Gao Y,Ortega FR,Adjouadi M

    更新日期:2014-01-01 00:00:00

  • Models of flow-induced loading on blood cells in laminar and turbulent flow, with application to cardiovascular device flow.

    abstract::Viscous shear stress and Reynolds stress are often used to predict hemolysis and thrombosis due to flow-induced stress on blood elements in cardiovascular devices. These macroscopic stresses are distinct from the true stress on an individual cell, which is determined by the local microscale flow field. In this paper t...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-007-9308-8

    authors: Quinlan NJ,Dooley PN

    更新日期:2007-08-01 00:00:00

  • Two methods for recommending bat weights.

    abstract::Baseball players swung very light and very heavy bats through our instrument and the speed of the bat was recorded. These data were used to make mathematical models for each person. Then these models were coupled with equations of physics for bat-ball collisions to compute the Ideal Bat Weight for each individual. How...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02584443

    authors: Bahill AT,Freitas MM

    更新日期:1995-07-01 00:00:00

  • Fecobionics: A Novel Bionics Device for Studying Defecation.

    abstract::During defecation, solid, semisolid or liquid stools are eliminated via the anus in a complex physiological process. Up to 25% of the population are affected by anorectal disorders that are poorly recognized and treated. We developed a new bionics device, a simulated stool named Fecobionics, to replace several current...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-018-02149-1

    authors: Sun D,Huang Z,Zhuang Z,Ma Z,Man LK,Liao D,Gregersen H

    更新日期:2019-02-01 00:00:00

  • Motile Dendritic Cells Sense and Respond to Substrate Geometry.

    abstract::Dendritic cell (DC) migration is required for efficient presentation of antigen to T cells and the initiation of an adaptive immune response. In spite of its importance, many aspects of DC migration have not been characterized. DCs encounter a variety of environments with different stiffness and geometry, but the effe...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-018-2041-7

    authors: Bendell AC,Anderson N,Blumenthal D,Williamson EK,Chen CS,Burkhardt JK,Hammer DA

    更新日期:2018-09-01 00:00:00

  • A Fluorescence Sensing Method with Reduced DNA Typing and Low-Cost Instrumentation for Detection of Sample Tampering Cases in Urinalysis.

    abstract::This work presents a method to unequivocally detect urine sample tampering in cases where integrity of the sample needs to be verified prior to urinalysis. The technique involves the detection of distinct patterns of a triplex short tandem repeats system in DNA extracted from human urine. The analysis is realized with...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-019-02386-y

    authors: Pires NMM,Dong T,Yang Z,Santos SMB

    更新日期:2020-02-01 00:00:00

  • An in vitro study of the hinge and near-field forward flow dynamics of the St. Jude Medical Regent bileaflet mechanical heart valve.

    abstract::The most widely implanted prosthetic valve is the mechanical bileaflet. Recent clinical experiences suggest that some designs are more prone to thromboembolic episodes than others. This study evaluated the hinge flow and near-field forward flow of the new St. Jude Medical Regent bileaflet mechanical heart valve. Laser...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.297

    authors: Ellis JT,Travis BR,Yoganathan AP

    更新日期:2000-05-01 00:00:00

  • Optimization of pulse train duration for the electrical stimulation of a skeletal muscle ventricle in the dog.

    abstract::The optimal means of electrically stimulating a skeletal muscle to contract around a fluid-filled pouch (i.e., a skeletal muscle ventricle [SMV]) has not been determined. A SMV was made from the latissimus dorsi muscle in five dogs and the rectus abdominis muscle in five dogs, and each SMV was electrically stimulated ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02364611

    authors: Badylak SF,Wessale JE,Geddes LA,Janas W

    更新日期:1990-01-01 00:00:00

  • Mitral Valve Regurgitation with a Rotary Left Ventricular Assist Device: The Haemodynamic Effect of Inlet Cannulation Site and Speed Modulation.

    abstract::Mitral valve regurgitation (MVR) is common in patients receiving left ventricular assist device (LVAD) support, however the haemodynamic effect of MVR is not entirely clear. This study evaluated the haemodynamic effect of MVR with LVAD support and the influence of inflow cannulation site and LVAD speed modulation. Lef...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-016-1579-5

    authors: Gregory SD,Stevens MC,Wu EL,Pauls JP,Kleinheyer M,Fraser JF

    更新日期:2016-09-01 00:00:00

  • Error mechanisms of the oscillometric fixed-ratio blood pressure measurement method.

    abstract::The oscillometric fixed-ratio method is widely employed for non-invasive measurement of systolic and diastolic pressures (SP and DP) but is heuristic and prone to error. We investigated the accuracy of this method using an established mathematical model of oscillometry. First, to determine which factors materially aff...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-012-0700-7

    authors: Liu J,Hahn JO,Mukkamala R

    更新日期:2013-03-01 00:00:00

  • Fractal character of pulmonary microvascular permeability.

    abstract::The pulmonary microvasculature offers a heterogeneous barrier to the motion of large solutes as they pass between blood and lymph. While this barrier has been approximated by a few discrete pathways or by statistical ensembles of many pathways, these descriptions only partly capture the structural and functional prope...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02368425

    authors: McNamee JE

    更新日期:1990-01-01 00:00:00

  • Biomechanical Challenges to Polymeric Biodegradable Stents.

    abstract::Biodegradable implants have demonstrated clinical success in simple applications (e.g., absorbable sutures) and have shown great potential in many other areas of interventional medicine, such as localized drug delivery, engineered tissue scaffolding, and structural implants. For endovascular stenting and musculoskelet...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1477-2

    authors: Soares JS,Moore JE Jr

    更新日期:2016-02-01 00:00:00

  • Electrophysiological modeling of fibroblasts and their interaction with myocytes.

    abstract::Experimental studies have shown that cardiac fibroblasts are electrically inexcitable, but can contribute to electrophysiology of myocardium in various manners. The aim of this computational study was to give insights in the electrophysiological role of fibroblasts and their interaction with myocytes. We developed a m...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-007-9405-8

    authors: Sachse FB,Moreno AP,Abildskov JA

    更新日期:2008-01-01 00:00:00

  • Stress relaxation preconditioning of porcine aortic valves.

    abstract::In uniaxial tensile testing, load preconditioning is used to generate repeatable load/elongation curves and set a "reference state" for subsequent tensile tests. We have observed however, that for porcine aortic valve (PAV) tissues, preconditioning does not lead to repeatable stress relaxation curves. We thus investig...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1023/b:abme.0000019176.49650.19

    authors: Carew EO,Garg A,Barber JE,Vesely I

    更新日期:2004-04-01 00:00:00

  • Countercurrent extraction of sparingly soluble gases for membrane introduction mass spectrometry.

    abstract::Membrane introduction mass spectrometry has been applied to inert gas measurements in blood and tissue, but gases with low blood solubility are associated with reduced sensitivity. Countercurrent extraction of inert gases from a blood sample into a water carrier phase has the potential to extract most of the gas sampl...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02684170

    authors: Baumgardner JE,Neufeld GR

    更新日期:1997-09-01 00:00:00

  • A preliminary physiologically based pharmacokinetic model for naphthalene and naphthalene oxide in mice and rats.

    abstract::Naphthalene is a toxicant with unusual species and tissue specificity that has been the subject of in vitro studies. We describe a preliminary physiologically based pharmacokinetic (PBPK) model for naphthalene constructed solely from in vitro data for comparison to animal data without the use of adjustable parameters....

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02667357

    authors: Sweeney LM,Shuler ML,Quick DJ,Babish JG

    更新日期:1996-03-01 00:00:00

  • Low Impedance Carbon Adhesive Electrodes with Long Shelf Life.

    abstract::A novel electrocardiogram (ECG) electrode film is developed by mixing carbon black powder and a quaternary salt with a visco-elastic polymeric adhesive. Unlike traditional wet gel-based electrodes, carbon/salt/adhesive (CSA) electrodes should theoretically have an infinite shelf life as they do not dehydrate even afte...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1282-y

    authors: Posada-Quintero HF,Reyes BA,Burnham K,Pennace J,Chon KH

    更新日期:2015-10-01 00:00:00

  • Simulation of two-dimensional anisotropic cardiac reentry: effects of the wavelength on the reentry characteristics.

    abstract::A two-dimensional sheet model was used to study the dynamics of reentry around a zone of functional block. The sheet is a set of parallel, continuous, and uniform cables, transversely interconnected by a brick-wall arrangement of fixed resistors. In accord with experimental observations on cardiac tissue, longitudinal...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02368286

    authors: Leon LJ,Roberge FA,Vinet A

    更新日期:1994-11-01 00:00:00

  • Body Anthropometry and Bone Strength Conjointly Determine the Risk of Hip Fracture in a Sideways Fall.

    abstract::We hypothesize that variations of body anthropometry, conjointly with the bone strength, determine the risk of hip fracture. To test the hypothesis, we compared, in a simulated sideways fall, the hip impact energy to the energy needed to fracture the femur. Ten femurs from elderly donors were tested using a novel drop...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02682-y

    authors: Palanca M,Perilli E,Martelli S

    更新日期:2020-11-12 00:00:00

  • A Novel High-Resolution Method for the Respiration Rate and Breathing Waveforms Remote Monitoring.

    abstract::A search for robust noninvasive methods permitting to discern the respiration subtle peculiarities in mammals is a topical issue. A novel approach called "sorption-enhanced infrared thermography" (SEIRT), helping to solve this problem, is described. Its benefits spring from the integration of the infrared thermography...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-018-2018-6

    authors: Vainer BG

    更新日期:2018-07-01 00:00:00

  • Evaluation of three animal models for concussion and serious brain injury.

    abstract::Three animal models were evaluated in this study involving head impacts of the rat, including the Marmarou drop-weight and two momentum-exchange techniques. In series 1, 36 Wistar rats were hit on the side of the free-moving head using Marmarou's 450 g impact mass at 4.4, 5.4, and 6.3 m/s. Head acceleration was measur...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-011-0386-2

    authors: Viano DC,Hamberger A,Bolouri H,Säljö A

    更新日期:2012-01-01 00:00:00

  • Optimizing magnetic nanoparticle based thermal therapies within the physical limits of heating.

    abstract::Magnetic nanoparticle (mNP) based thermal therapies have demonstrated relevance in the clinic, but effective application requires an understanding of both its strengths and limitations. This study explores two critical limitations for clinical use: (1) maximizing localized mNP heating, while avoiding bulk heating due ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-012-0633-1

    authors: Etheridge ML,Bischof JC

    更新日期:2013-01-01 00:00:00