Error mechanisms of the oscillometric fixed-ratio blood pressure measurement method.

Abstract:

:The oscillometric fixed-ratio method is widely employed for non-invasive measurement of systolic and diastolic pressures (SP and DP) but is heuristic and prone to error. We investigated the accuracy of this method using an established mathematical model of oscillometry. First, to determine which factors materially affect the errors of the method, we applied a thorough parametric sensitivity analysis to the model. Then, to assess the impact of the significant parameters, we examined the errors over a physiologically relevant range of those parameters. The main findings of this model-based error analysis of the fixed-ratio method are that: (1) SP and DP errors drastically increase as the brachial artery stiffens over the zero trans-mural pressure regime; (2) SP and DP become overestimated and underestimated, respectively, as pulse pressure (PP) declines; (3) the impact of PP on SP and DP errors is more obvious as the brachial artery stiffens over the zero trans-mural pressure regime; and (4) SP and DP errors can be as large as 58 mmHg. Our final and main contribution is a comprehensive explanation of the mechanisms for these errors. This study may have important implications when using the fixed-ratio method, particularly in subjects with arterial disease.

journal_name

Ann Biomed Eng

authors

Liu J,Hahn JO,Mukkamala R

doi

10.1007/s10439-012-0700-7

subject

Has Abstract

pub_date

2013-03-01 00:00:00

pages

587-97

issue

3

eissn

0090-6964

issn

1573-9686

journal_volume

41

pub_type

杂志文章
  • Computational tools for quantitative breast morphometry based on 3D scans.

    abstract::Quantitative analysis of breast morphometry is critical to breast plastic surgery. Recently, three-dimensional (3D) photography has emerged as a strong new alternative for breast morphometry analysis in comparison to other existing techniques. 3D photography enables the capture of the entire breast surface topology vi...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-9971-z

    authors: Chen D,Chittajallu DR,Passalis G,Kakadiaris IA

    更新日期:2010-05-01 00:00:00

  • Micro-computed tomography based computational fluid dynamics for the determination of shear stresses in scaffolds within a perfusion bioreactor.

    abstract::Perfusion bioreactors are known to exert shear stresses on cultured cells, leading to cell differentiation and enhanced extracellular matrix deposition on scaffolds. The influence of the scaffold's porous microstructure is investigated for a polycaprolactone (PCL) scaffold with a regular microarchitecture and a silk f...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-014-0981-0

    authors: Zermatten E,Vetsch JR,Ruffoni D,Hofmann S,Müller R,Steinfeld A

    更新日期:2014-05-01 00:00:00

  • Continuous and noninvasive blood pressure measurement: a novel modeling methodology of the relationship between blood pressure and pulse wave velocity.

    abstract::In this paper, we aim to establish a new mathematical model that relates pulse wave velocity (PWV) to blood pressure (BP) for continuous and noninvasive BP measurement. For the first time, we derive an ordinary differential equation (ODE) expressing the fundamental relation between BP, elastic modulus G and PWV. The g...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-009-9759-1

    authors: Chen Y,Wen C,Tao G,Bi M,Li G

    更新日期:2009-11-01 00:00:00

  • An Integrated In Vitro-In Silico Approach for Silver Nanoparticle Dosimetry in Cell Cultures.

    abstract::Potential human and environmental hazards resulting from the exposure of living organisms to silver nanoparticles (Ag NPs) have been the subject of intensive discussion in the last decade. Despite the growing use of Ag NPs in biomedical applications, a quantification of the toxic effects as a function of the total sil...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02449-5

    authors: Poli D,Mattei G,Ucciferri N,Ahluwalia A

    更新日期:2020-04-01 00:00:00

  • In vitro characterization of a compliant biodegradable scaffold with a novel bioreactor system.

    abstract::The influence of scaffold compliance on blood vessel tissue engineering remains unclear and compliance mismatch issues are important to an in vivo tissue-engineering approach. We have designed and constructed a modular bioreactor system that is capable of imparting pulsatile fluid flow while simultaneously measuring v...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-007-9304-z

    authors: Webb AR,Macrie BD,Ray AS,Russo JE,Siegel AM,Glucksberg MR,Ameer GA

    更新日期:2007-08-01 00:00:00

  • The effect of strain rate on the viscoelastic response of aortic valve tissue: a direct-fit approach.

    abstract::Knowledge of strain-rate sensitivity of soft tissue viscoelastic and nonlinear elastic properties is important for accurate predictions of biomechanical behavior and for quantitative assessment of the effects of disease or surgical/pharmaceutical intervention. Soft tissues are known to exhibit mild rate sensitivity, b...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1023/b:abme.0000012742.01261.b0

    authors: Doehring TC,Carew EO,Vesely I

    更新日期:2004-02-01 00:00:00

  • Analog electrical model of the coronary circulation in case of multiple revascularizations.

    abstract::In this work, we propose an analog electrical model of the coronary circulation for patients with obstructive disease undergoing revascularization. In this clinical situation, the collateral circulation to the occluded artery is difficult to ascertain via preoperative measurements and well-developed collaterals might ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-008-9500-5

    authors: Maasrani M,Verhoye JP,Corbineau H,Drochon A

    更新日期:2008-07-01 00:00:00

  • Dynamics of cardiac period responses after prolonged vagal stimulation in the dog.

    abstract::In 12 dogs anesthetised with alpha-chloralose and urethane, and beta-adrenergic blocked with propranolol, the cervical vagi were stimulated for 60 seconds with supramaximal constant current pulses at frequencies between 2.0 and 10 Hz. The time course of the recovery of the cardiac period response, after cessation of v...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02584303

    authors: Celler BG,Lovell NH

    更新日期:1991-01-01 00:00:00

  • Transport Analysis of Engineered Liver Tissue Fabricated Using a Capsule-Based, Modular Approach.

    abstract::The bioinspired, microscale tissue engineering approach has emerged in recent years as a promising alternative to preformed scaffolds. Using this approach, complex tissues and organs can be efficiently engineered from microscale modules to replicate the intricate architecture and physiology of vascularized organs and ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-018-02192-y

    authors: Annamalai RT,Matthew HWT

    更新日期:2019-05-01 00:00:00

  • A novel method for visualization of entire coronary arterial tree.

    abstract::The complexity of the coronary circulation especially in the deep layers largely evades experimental investigations. Hence, virtual/computational models depicting structure-function relation of the entire coronary vasculature including the deep layer are imperative. In order to interpret such anatomically based models...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-007-9278-x

    authors: Wischgoll T,Meyer J,Kaimovitz B,Lanir Y,Kassab GS

    更新日期:2007-05-01 00:00:00

  • Dynamics of revolution time variability in cycling pattern: voluntary intent can alter the long-range autocorrelations.

    abstract::Long-range dependency has been found in most rhythmic motor signals. The origin of this property is unknown and largely debated. There is a controversy on the influence of voluntary control induced by requiring a pre-determined pace such as asking subjects to step to a metronome. We studied the cycle duration variabil...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,随机对照试验

    doi:10.1007/s10439-013-0834-2

    authors: Warlop TB,Bollens B,Crevecoeur F,Detrembleur C,Lejeune TM

    更新日期:2013-08-01 00:00:00

  • Native, living tissues as cell seeded scaffolds.

    abstract::Much effort is expended in developing biomimetic scaffolds that provide the micro-architecture of native tissue with appropriate cellular niches. Such scaffolds are often seeded with progenitor cells to generate engineered replacements for diseased or damaged tissues. An alternative approach relies on biology, rather ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/s10439-014-1174-6

    authors: Evans CH

    更新日期:2015-03-01 00:00:00

  • A visualization-based analysis method for multiparameter models of capillary tissue-exchange.

    abstract::In order to successfully use a model for parameter identification, it must be carefully analyzed. Current analysis methods, however, are ad hoc and provide only partial information. We extended these methods through the application of stacked dimensions, a scientific visualization method. The end result of our extensi...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02771001

    authors: Bosan S,Harris TR

    更新日期:1996-01-01 00:00:00

  • Modeling Human Volunteers in Multidirectional, Uni-axial Sled Tests Using a Finite Element Human Body Model.

    abstract::A goal of the Human Research Program at National Aeronautics and Space Administration (NASA) is to analyze and mitigate the risk of occupant injury due to dynamic loads. Experimental tests of human subjects and biofidelic anthropomorphic test devices provide valuable kinematic and kinetic data related to injury risk e...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-018-02147-3

    authors: Gaewsky JP,Jones DA,Ye X,Koya B,McNamara KP,Gayzik FS,Weaver AA,Putnam JB,Somers JT,Stitzel JD

    更新日期:2019-02-01 00:00:00

  • CareToy: Stimulation and Assessment of Preterm Infant's Activity Using a Novel Sensorized System.

    abstract::Early intervention programs aim at improving cognitive and motor outcomes of preterm infants. Intensive custom-tailored training activities are usually accompanied by assessment procedures, which have shortcomings, such as subjectivity, complex setups, and need for structured environments. A novel sensorized system, c...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-016-1669-4

    authors: Rihar A,Sgandurra G,Beani E,Cecchi F,Pašič J,Cioni G,Dario P,Mihelj M,Munih M

    更新日期:2016-12-01 00:00:00

  • Partial Bone Formation in Additive Manufactured Porous Implants Reduces Predicted Stress and Danger of Fatigue Failure.

    abstract::New porous implant designs made possible by additive manufacturing allow for increased osseointegration, potentially improving implant performance and longevity for patients that require massive bone implants. The aim of this study was to evaluate how implantation and the strain distribution in the implant affect the ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-019-02369-z

    authors: Cheong VS,Fromme P,Coathup MJ,Mumith A,Blunn GW

    更新日期:2020-01-01 00:00:00

  • A mediated glucose biosensor incorporated with reverse iontophoresis function for noninvasive glucose monitoring.

    abstract::The objective of this study was to develop a ferrocene mediated glucose biosensor for reverse iontophoresis. An amperometric ferrocene mediated glucose biosensor based on a three electrodes planar configuration was constructed using screen printing technique. Different combinations of glucose oxidase and ferrocene loa...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-9918-4

    authors: Ching CT,Sun TP,Huang SH,Shieh HL,Chen CY

    更新日期:2010-04-01 00:00:00

  • Geometric and flow features of type B aortic dissection: initial findings and comparison of medically treated and stented cases.

    abstract::Uncomplicated acute type B aortic dissections are usually treated medically, but they can become acutely complicated by rapid expansion, rupture and malperfusion syndromes and in the longer term by chronic dilatation and aortic aneurysm formation. The objective of this study is to use computational fluid dynamics reco...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-014-1075-8

    authors: Cheng Z,Wood NB,Gibbs RG,Xu XY

    更新日期:2015-01-01 00:00:00

  • Quantification of rigidity in Parkinson's disease.

    abstract::In this paper, a new method for quantification of rigidity in elbow joint of Parkinsonian patients is introduced. One of the most known syndromes in Parkinson's disease (PD) is increased passive stiffness in muscles, which leads to rigidity in joints. Clinical evaluation of stiffness in wrist and/or elbow, commonly us...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-007-9379-6

    authors: Sepehri B,Esteki A,Ebrahimi-Takamjani E,Shahidi GA,Khamseh F,Moinodin M

    更新日期:2007-12-01 00:00:00

  • Low-Profile Electromagnetic Field Sensors in the Measurement and Modelling of Three-Dimensional Jaw Kinematics and Occlusal Loading.

    abstract::Dynamic occlusal loading during mastication is clinically relevant in the design and functional assessment of dental restorations and removable dentures, and in evaluating temporomandibular joint dysfunction. The aim of this study was to develop a modelling framework to evaluate subject-specific dynamic occlusal loadi...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02688-6

    authors: Woodford SC,Robinson DL,Edelmann C,Mehl A,Röhrle O,Vee Sin Lee P,Ackland DC

    更新日期:2021-01-06 00:00:00

  • Two methods for calculating the responses of photoreceptors to moving objects.

    abstract::The responses of photoreceptor cells to moving stimuli are crucial to understanding motion detection in visual systems. However, these responses are not well characterized quantitatively because they result from a combination of spatial optical behavior in the lens systems with temporal behavior in the phototransducti...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.58

    authors: Korenberg MJ,Juusola M,French AS

    更新日期:1998-03-01 00:00:00

  • Blood pressure measurement in noise intensive environments using adaptive interference cancellation.

    abstract::The traditional auscultatory technique and current methodologies for measuring human blood pressure are limited when used in situations where extreme vibration or acoustic noise is present. In this study, human subjects were used to establish the effectiveness of a novel adaptive blood pressure monitoring (ABPM) syste...

    journal_title:Annals of biomedical engineering

    pub_type: 临床试验,杂志文章

    doi:10.1114/1.1481051

    authors: Pinto L,Dhanantwari A,Wong W,Stergiopoulos S,Maris M

    更新日期:2002-05-01 00:00:00

  • Population-Based Bone Strain During Physical Activity: A Novel Method Demonstrated for the Human Femur.

    abstract::Statistical methods are increasingly used in biomechanics for studying bone geometry, bone density distribution and function in the population. However, relating population-based bone variation to strain during activity is computationally challenging. Here, we describe a new method for calculating strain in a populati...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02483-3

    authors: Ziaeipoor H,Taylor M,Martelli S

    更新日期:2020-06-01 00:00:00

  • Antithrombotic Protein Filter Composed of Hybrid Tissue-Fabric Material has a Long Lifetime.

    abstract::There are recent reports of hybrid tissue-fabric materials with good performance-high biocompatibility and high mechanical strength. In this study, we demonstrate the capability of a hybrid material as a long-term filter for blood proteins. Polyester fabrics were implanted into rats to fabricate hybrid tissue-fabric m...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-016-1781-5

    authors: Inoue Y,Yokota T,Sekitani T,Kaneko A,Woo T,Kobayashi S,Shibuya T,Tanaka M,Kosukegawa H,Saito I,Isoyama T,Abe Y,Yambe T,Someya T,Sekino M

    更新日期:2017-05-01 00:00:00

  • Countercurrent extraction of sparingly soluble gases for membrane introduction mass spectrometry.

    abstract::Membrane introduction mass spectrometry has been applied to inert gas measurements in blood and tissue, but gases with low blood solubility are associated with reduced sensitivity. Countercurrent extraction of inert gases from a blood sample into a water carrier phase has the potential to extract most of the gas sampl...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02684170

    authors: Baumgardner JE,Neufeld GR

    更新日期:1997-09-01 00:00:00

  • Off-line and on-line stress detection through processing of the pupil diameter signal.

    abstract::The pupil diameter (PD), controlled by the autonomic nervous system, seems to provide a strong indication of affective arousal, as found by previous research, but it has not been investigated fully yet. In this study, new approaches based on monitoring and processing the PD signal for off-line and on-line "relaxation"...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-013-0880-9

    authors: Ren P,Barreto A,Huang J,Gao Y,Ortega FR,Adjouadi M

    更新日期:2014-01-01 00:00:00

  • Nanoparticle deposition onto biofilms.

    abstract::We develop a mathematical model of nanoparticles depositing onto and penetrating into a biofilm grown in a parallel-plate flow cell. We carry out deposition experiments in a flow cell to support the modeling. The modeling and the experiments are motivated by the potential use of polymer nanoparticles as part of a trea...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-012-0626-0

    authors: Miller JK,Neubig R,Clemons CB,Kreider KL,Wilber JP,Young GW,Ditto AJ,Yun YH,Milsted A,Badawy HT,Panzner MJ,Youngs WJ,Cannon CL

    更新日期:2013-01-01 00:00:00

  • Kinematic analysis of the human temporomandibular joint.

    abstract::A kinematic analysis of the temporomandibular joint (TMJ) is developed to determine the range of motion of the mandible during normal opening and during special motions required for arthroscopic surgery. The translation of the mandible is restricted by the constraint of the ligaments. By accounting for the maximum all...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02368648

    authors: Kang QS,Updike DP,Salathe EP

    更新日期:1993-11-01 00:00:00

  • Investigating the influence of haemodynamic stimuli on intracranial aneurysm inception.

    abstract::We propose a novel method to reconstruct the hypothetical geometry of the healthy vasculature prior to intracranial aneurysm (IA) formation: a Frenet frame is calculated along the skeletonization of the arterial geometry; upstream and downstream boundaries of the aneurysmal segment are expressed in terms of the local ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-013-0794-6

    authors: Chen H,Selimovic A,Thompson H,Chiarini A,Penrose J,Ventikos Y,Watton PN

    更新日期:2013-07-01 00:00:00

  • Analysis of electrically induced reentrant circuits in a sheet of myocardium.

    abstract::Understanding the complex spatiotemporal dynamics of action potential propagation in the heart during arrhythmia is exceedingly difficult. This study applies nonlinear dynamics tools to simplify this task. Using the results of a simulation of an electrical induction of reentry in a sheet of myocardium represented as a...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1581289

    authors: Larson C,Dragnev L,Trayanova N

    更新日期:2003-07-01 00:00:00