Dynamics of revolution time variability in cycling pattern: voluntary intent can alter the long-range autocorrelations.

Abstract:

:Long-range dependency has been found in most rhythmic motor signals. The origin of this property is unknown and largely debated. There is a controversy on the influence of voluntary control induced by requiring a pre-determined pace such as asking subjects to step to a metronome. We studied the cycle duration variability of 15 men pedaling on an ergometer at free pace and at an imposed pace (60 rpm). Revolution time was determined based on accelerometer signals (sample frequency 512 Hz). Revolution time variability was assessed by coefficient of variation (CV). The presence of long-range autocorrelations was based on scaling properties of the series variability (Hurst exponent) and the shape of the power spectral density (α exponent). Mean revolution time was significantly lower at freely chosen cadence, while values of CV were similar between both sessions. Long-range autocorrelations were highlighted in all series of cycling patterns. However, Hurst and α exponents were significantly lower at imposed cadence. This study demonstrates the presence of long-range autocorrelations during cycling and that voluntary intent can modulate the interdependency between consecutive cycles. Therefore, cycling may constitute a powerful paradigm to investigate the influence of central control mechanisms on the long-range interdependency characterizing rhythmic motor tasks.

journal_name

Ann Biomed Eng

authors

Warlop TB,Bollens B,Crevecoeur F,Detrembleur C,Lejeune TM

doi

10.1007/s10439-013-0834-2

subject

Has Abstract

pub_date

2013-08-01 00:00:00

pages

1604-12

issue

8

eissn

0090-6964

issn

1573-9686

journal_volume

41

pub_type

杂志文章,随机对照试验
  • Validity of Skin, Oral and Tympanic Temperatures During Exercise in the Heat: Effects of Wind and Sweat.

    abstract::This experiment investigates the validity of six thermometers with different measuring sensors, operation and site of application, to estimate core temperature (Tc) in comparison to an ingestible thermometric sensor based on quartz crystal technology. Measurements were obtained before, during and after exercise in the...

    journal_title:Annals of biomedical engineering

    pub_type: 临床试验,杂志文章

    doi:10.1007/s10439-018-02115-x

    authors: Morán-Navarro R,Courel-Ibáñez J,Martínez-Cava A,Conesa-Ros E,Sánchez-Pay A,Mora-Rodriguez R,Pallarés JG

    更新日期:2019-01-01 00:00:00

  • Developments and Control of Biocompatible Conducting Polymer for Intracorporeal Continuum Robots.

    abstract::Dexterity of robots is highly required when it comes to integration for medical applications. Major efforts have been conducted to increase the dexterity at the distal parts of medical robots. This paper reports on developments toward integrating biocompatible conducting polymers (CP) into inherently dexterous concent...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-018-2038-2

    authors: Chikhaoui MT,Benouhiba A,Rougeot P,Rabenorosoa K,Ouisse M,Andreff N

    更新日期:2018-10-01 00:00:00

  • Sharing best practices in teaching biomedical engineering design.

    abstract::In an effort to share best practices in undergraduate engineering design education, we describe the origin, evolution and the current status of the undergraduate biomedical engineering design team program at Johns Hopkins University. Specifically, we describe the program and judge the quality of the pedagogy by relati...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-013-0781-y

    authors: Allen RH,Acharya S,Jancuk C,Shoukas AA

    更新日期:2013-09-01 00:00:00

  • Tensile strain as a regulator of mesenchymal stem cell osteogenesis.

    abstract::A role for mechanical stimulation in the control of cell fate has been proposed and mechanical conditioning of mesenchymal stem cells (MSCs) is of interest in directing MSC behavior for tissue engineering applications. This study investigates strain-induced differentiation and proliferation of MSCs, and investigates t...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-9979-4

    authors: Kearney EM,Farrell E,Prendergast PJ,Campbell VA

    更新日期:2010-05-01 00:00:00

  • Error mechanisms of the oscillometric fixed-ratio blood pressure measurement method.

    abstract::The oscillometric fixed-ratio method is widely employed for non-invasive measurement of systolic and diastolic pressures (SP and DP) but is heuristic and prone to error. We investigated the accuracy of this method using an established mathematical model of oscillometry. First, to determine which factors materially aff...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-012-0700-7

    authors: Liu J,Hahn JO,Mukkamala R

    更新日期:2013-03-01 00:00:00

  • The Impact of Anti-tumor Agents on ER-Positive MCF-7 and HER2-Positive SKBR-3 Breast Cancer Cells Biomechanics.

    abstract::Studying human cancer from a biomechanical perspective may contribute to pathogenesis understanding which leads to the malignancy. In this study, biomechanics of suspended and adhered breast cancer cells were investigated via the micropipette aspiration method with special emphasis on comparing the cell stiffness and ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-019-02284-3

    authors: Metsiou DN,Siatis KE,Giannopoulou E,Papachristou DJ,Kalofonos HP,Koutras A,Athanassiou G

    更新日期:2019-08-01 00:00:00

  • Rat aortic smooth muscle cells contract in response to serum and its components in a calcium independent manner.

    abstract::Diluted serum provides a model of interstitial fluid that can be used to study the response of smooth muscle cells (SMCs) to interstitial flow. The effect of serum and some of its components on SMC contraction (area reduction) and intracellular calcium ([Ca2+]i) response were characterized in rat aortic SMC in vitro. ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-004-7820-7

    authors: Ainslie K,Shi ZD,Garanich JS,Tarbell JM

    更新日期:2004-12-01 00:00:00

  • Carbachol-induced volume adaptation in mouse bladder and length adaptation via rhythmic contraction in rabbit detrusor.

    abstract::The length-tension (L-T) relationships in rabbit detrusor smooth muscle (DSM) are similar to those in vascular and airway smooth muscles and exhibit short-term length adaptation characterized by L-T curves that shift along the length axis as a function of activation and strain history. In contrast to skeletal muscle, ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-012-0590-8

    authors: Speich JE,Wilson CW,Almasri AM,Southern JB,Klausner AP,Ratz PH

    更新日期:2012-10-01 00:00:00

  • Micro-flow visualization of red blood cell-enhanced platelet concentration at sudden expansion.

    abstract::Microscopic steps and crevices are inevitable features within prosthetic blood-contacting devices. This study aimed to elucidate the thrombogenicity of the associated microscopic flow features by studying the transport of fluorescent platelet-sized particles in a suspension of red blood cells (RBCs) flowing through a ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-008-9494-z

    authors: Zhao R,Marhefka JN,Shu F,Hund SJ,Kameneva MV,Antaki JF

    更新日期:2008-07-01 00:00:00

  • Design considerations for a microfluidic device to quantify the platelet adhesion to collagen at physiological shear rates.

    abstract::Accurate assessment of blood platelet function is essential in understanding thrombus formation which plays a central role in cardiovascular disease. Parallel plate flow chambers have been widely used as they allow for platelet adhesion on a collagen surface at physiologically relevant fluid mechanical forces. Standar...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-009-9708-z

    authors: Sarvepalli DP,Schmidtke DW,Nollert MU

    更新日期:2009-07-01 00:00:00

  • Cue-Signal-Response Analysis in 3D Chondrocyte Scaffolds with Anabolic Stimuli.

    abstract::Articular cartilage is an avascular connective tissue responsible for bearing loads. Cell signaling plays a central role in cartilage homeostasis and tissue engineering by directing chondrocytes to synthesize/degrade the extracellular matrix or promote inflammatory responses. The aim of this paper was to investigate a...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-017-1964-8

    authors: Neidlin M,Korcari A,Macheras G,Alexopoulos LG

    更新日期:2018-02-01 00:00:00

  • Transport Analysis of Engineered Liver Tissue Fabricated Using a Capsule-Based, Modular Approach.

    abstract::The bioinspired, microscale tissue engineering approach has emerged in recent years as a promising alternative to preformed scaffolds. Using this approach, complex tissues and organs can be efficiently engineered from microscale modules to replicate the intricate architecture and physiology of vascularized organs and ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-018-02192-y

    authors: Annamalai RT,Matthew HWT

    更新日期:2019-05-01 00:00:00

  • A single equivalent moving dipole model: an efficient approach for localizing sites of origin of ventricular electrical activation.

    abstract::We propose a new method for guiding catheter ablation procedures to abolish sites of origin of arrhythmias. This method models both cardiac electrical activity and current pulses delivered from the tip of the ablation catheter with a single equivalent moving dipole (SEMD). The SEMD parameters are obtained from analysi...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1567281

    authors: Armoundas AA,Feldman AB,Mukkamala R,Cohen RJ

    更新日期:2003-05-01 00:00:00

  • Computer modeling of red blood cell rheology in the microcirculation: a brief overview.

    abstract::One of the major functions of the cardiovascular system is to deliver blood to the microcirculation where exchange of mass and energy can take place. In the present article, we will provide an overview of the state-of-the-art computational methods for modeling of red blood cell (RBC) rheology and dynamics in the micro...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-005-8776-y

    authors: Cristini V,Kassab GS

    更新日期:2005-12-01 00:00:00

  • Sensor Anchoring Improves the Correlation Between Intramuscular Pressure and Muscle Tension in a Rabbit Model.

    abstract::Intramuscular pressure (IMP) shows promise for estimating individual muscle tension in vivo. However, previous pressure measurements show high variability during isometric contraction and poor correlation with tension during dynamic contraction. We hypothesized that enhanced sensor anchoring/orientation would improve ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02633-7

    authors: O'Connor SM,Kaufman KR,Ward SR,Lieber RL

    更新日期:2021-02-01 00:00:00

  • Acoustic Emissions as a Non-invasive Biomarker of the Structural Health of the Knee.

    abstract::The longitudinal assessment of joint health is a long-standing issue in the management of musculoskeletal injuries. The acoustic emissions (AEs) produced by joint articulation could serve as a biomarker for joint health assessment, but their use has been limited by a lack of mechanistic understanding of their creation...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-019-02333-x

    authors: Whittingslow DC,Jeong HK,Ganti VG,Kirkpatrick NJ,Kogler GF,Inan OT

    更新日期:2020-01-01 00:00:00

  • Utilizing Atlas-Based Modeling to Predict Knee Joint Cartilage Degeneration: Data from the Osteoarthritis Initiative.

    abstract::Currently, there are no clinically available tools or applications which could predict osteoarthritis development. Some computational models have been presented to simulate cartilage degeneration, but they are not clinically feasible due to time required to build subject-specific knee models. Therefore, the objective ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-018-02184-y

    authors: Mononen ME,Liukkonen MK,Korhonen RK

    更新日期:2019-03-01 00:00:00

  • Fabrication and mechanical evaluation of anatomically-inspired quasilaminate hydrogel structures with layer-specific formulations.

    abstract::A major tissue engineering challenge is the creation of multilaminate scaffolds with layer-specific mechanical properties representative of native tissues, such as heart valve leaflets, blood vessels, and cartilage. For this purpose, poly(ethylene glycol) diacrylate (PEGDA) hydrogels are attractive materials due to th...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-012-0666-5

    authors: Tseng H,Cuchiara ML,Durst CA,Cuchiara MP,Lin CJ,West JL,Grande-Allen KJ

    更新日期:2013-02-01 00:00:00

  • A physical model describing the mechanism for formation of gas microbubbles in patients with mitral mechanical heart valves.

    abstract::This study was aimed at developing a physical model, supported by experimental observations, to describe the formation and growth of microbubbles seen in patients with mitral mechanical heart valves (MHV). This phenomenon, often referred to as high intensity transient signals (HITS), appears as bright, intense, high-v...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.231

    authors: Rambod E,Beizaie M,Shusser M,Milo S,Gharib M

    更新日期:1999-11-01 00:00:00

  • Insulin minimal model indexes and secretion: proper handling of uncertainty by a Bayesian approach.

    abstract::The identification of the insulin minimal model (MM) for the estimation of insulin secretion rate (ISR) and physiological indexes (e.g. beta-cell sensitivity) requires the knowledge of C-peptide (CP) kinetics. The four parameters of the two-compartment model of CP kinetics in a given individual can be derived either f...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1023/b:abme.0000032465.75888.91

    authors: Magni P,Sparacino G,Bellazzi R,Toffolo GM,Cobelli C

    更新日期:2004-07-01 00:00:00

  • MUlti-Dimensional Spline-Based Estimator (MUSE) for motion estimation: algorithm development and initial results.

    abstract::Image registration and motion estimation play central roles in many fields, including RADAR, SONAR, light microscopy, and medical imaging. Because of its central significance, estimator accuracy, precision, and computational cost are of critical importance. We have previously presented a highly accurate, spline-based ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-008-9564-2

    authors: Viola F,Coe RL,Owen K,Guenther DA,Walker WF

    更新日期:2008-12-01 00:00:00

  • Hemodynamic energy dissipation in the cardiovascular system: generalized theoretical analysis on disease states.

    abstract:BACKGROUND:We present a fundamental theoretical framework for analysis of energy dissipation in any component of the circulatory system and formulate the full energy budget for both venous and arterial circulations. New indices allowing disease-specific subject-to-subject comparisons and disease-to-disease hemodynamic ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-009-9650-0

    authors: Dasi LP,Pekkan K,de Zelicourt D,Sundareswaran KS,Krishnankutty R,Delnido PJ,Yoganathan AP

    更新日期:2009-04-01 00:00:00

  • The effect of blood flow on the material properties of bone.

    abstract::This project was undertaken to establish if the integral circulation had any effects upon the mechanical behavior of bone. The influence of blood flow in the rabbit tibia on the strain induced at the bone surface when under load was assessed. Recordings were taken from three adult and three immature New Zealand White ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02390377

    authors: McDonald F,Pitt Ford TR

    更新日期:1994-03-01 00:00:00

  • Modeling of Experimental Atherosclerotic Plaque Delamination.

    abstract::A cohesive zone model (CZM) approach is applied to simulate atherosclerotic plaque delamination experiments in mouse abdominal aorta specimens. A three-dimensional finite element model is developed for the experiments. The aortic wall is treated as a fiber-reinforced, highly deformable, incompressible material, and th...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1357-9

    authors: Leng X,Chen X,Deng X,Sutton MA,Lessner SM

    更新日期:2015-12-01 00:00:00

  • Left-right asymmetry of visual evoked potentials in brain-damaged patients: a mathematical model and experimental results.

    abstract::The left-right asymmetry in the potential amplitude on the scalp was studied in poststroke patients by using flash visual evoked potential (VEP) and a numerical two-dimensional model of the head. The left-right asymmetry of the VEP was measured in three patients after thrombosis, in one after hemorrhage, and in one he...

    journal_title:Annals of biomedical engineering

    pub_type: 临床试验,杂志文章

    doi:10.1007/BF02770997

    authors: Abboud S,Bar L,Rosenfeld M,Ring H,Glass I

    更新日期:1996-01-01 00:00:00

  • Micro-computed tomography based computational fluid dynamics for the determination of shear stresses in scaffolds within a perfusion bioreactor.

    abstract::Perfusion bioreactors are known to exert shear stresses on cultured cells, leading to cell differentiation and enhanced extracellular matrix deposition on scaffolds. The influence of the scaffold's porous microstructure is investigated for a polycaprolactone (PCL) scaffold with a regular microarchitecture and a silk f...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-014-0981-0

    authors: Zermatten E,Vetsch JR,Ruffoni D,Hofmann S,Müller R,Steinfeld A

    更新日期:2014-05-01 00:00:00

  • Study on tumor microvasculature damage induced by alternate cooling and heating.

    abstract::Tumor vasculature damage induced by various thermal treatments has been studied in vivo via laser confocal microscopy. Murine mammary carcinoma 4T1 was implanted in the nude mice dorsal skin fold window chamber. The implanted tumor was treated by alternate cooling and heating. Results showed that the treatment was muc...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-008-9511-2

    authors: Shen Y,Liu P,Zhang A,Xu LX

    更新日期:2008-08-01 00:00:00

  • Assessing the susceptibility to local buckling at the femoral neck cortex to age-related bone loss.

    abstract::Although it is known that long cortical bone structurally alter their area moment of inertia with age related bone loss maintaining their bending strength, the incidence of fragility fractures associated with cortical thinning still prevails. We hypothesize that cortical thinning with aging increases the local bucklin...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-009-9751-9

    authors: Lee T,Choi JB,Schafer BW,Segars WP,Eckstein F,Kuhn V,Beck TJ

    更新日期:2009-09-01 00:00:00

  • A finite volume method for modeling discontinuous electrical activation in cardiac tissue.

    abstract::This paper describes a finite volume method for modeling electrical activation in a sample of cardiac tissue using the bidomain equations. Microstructural features to the level of cleavage planes between sheets of myocardial fibers in the tissue are explicitly represented. The key features of this implementation compa...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-005-1434-6

    authors: Trew M,Le Grice I,Smaill B,Pullan A

    更新日期:2005-05-01 00:00:00

  • Net change in periosteal strain during stance shift loading after surgery correlates to rapid de novo bone generation in critically sized defects.

    abstract::In an ovine femur model, proliferative woven bone fills critically sized defects enveloped by periosteum within 2 weeks of treatment with the one-stage bone-transport surgery. We hypothesize that mechanical loading modulates this process. Using high-definition optical strain measurements we determined prevailing perio...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-0242-9

    authors: McBride SH,Dolejs S,Brianza S,Knothe U,Knothe Tate ML

    更新日期:2011-05-01 00:00:00