Evaluation of human endothelial cells post stent deployment in a cardiovascular simulator in vitro.

Abstract:

:Percutaneous stent implantation has revolutionized the clinical treatment of occluded arteries. Nevertheless, there is still a large unmet need to prevent re-occlusion after implantation. Consequently, a niche exists for a cost-effective pre-clinical method of evaluating novel interventional devices in human models. Therefore, the development of a coronary model artery offers tremendous potential for the treatment of endothelial cell dysfunction and restenosis. As a first step, we employ tissue-engineering principles to examine the effect of stent deployment upon endothelial cells in a tubular in vitro system capable of replicating the coronary artery biomechanical environment. In particular, the cellular and molecular changes pertaining to inflammation, proliferation, and death were assessed after stent deployment. Real-time quantitative PCR demonstrated increased expression of genes encoding for E-Selectin, ICAM-1, and VCAM-1; markers associated with an inflammatory response in vivo. Further, an increase in the pro-apoptotic protein Bax was paralleled with a decrease in the anti-apoptotic protein Bcl-2; however, apoptotic morphology was not observed. Interestingly, transcription of c-fos increased, whereas Ki67 levels fell over the same period. One hypothesis is that these results are in response to the altered local hemodynamic environment induced by stent deployment. Most significantly, this study highlights the potential of a biomimetic hemodynamic bioreactor combined with a gene expression analysis to evaluate, with greater specificity, the performance and interaction of stents with the endothelial layer in a controlled environment.

journal_name

Ann Biomed Eng

authors

Punchard MA,O'Cearbhaill ED,Mackle JN,McHugh PE,Smith TJ,Stenson-Cox C,Barron V

doi

10.1007/s10439-009-9701-6

subject

Has Abstract

pub_date

2009-07-01 00:00:00

pages

1322-30

issue

7

eissn

0090-6964

issn

1573-9686

journal_volume

37

pub_type

杂志文章
  • Analyzing Remodeling of Cardiac Tissue: A Comprehensive Approach Based on Confocal Microscopy and 3D Reconstructions.

    abstract::Microstructural characterization of cardiac tissue and its remodeling in disease is a crucial step in many basic research projects. We present a comprehensive approach for three-dimensional characterization of cardiac tissue at the submicrometer scale. We developed a compression-free mounting method as well as labelin...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1465-6

    authors: Seidel T,Edelmann JC,Sachse FB

    更新日期:2016-05-01 00:00:00

  • Development of a Platform for Studying 3D Astrocyte Mechanobiology: Compression of Astrocytes in Collagen Gels.

    abstract::Glaucoma is a common optic neuropathy characterized by retinal ganglion cell death. Elevated intraocular pressure (IOP), a key risk factor for glaucoma, leads to significant biomechanical deformation of optic nerve head (ONH) cells and tissues. ONH astrocytes respond to this deformation by transforming to a reactive, ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-017-1967-5

    authors: Mulvihill JJE,Raykin J,Snider EJ,Schildmeyer LA,Zaman I,Platt MO,Kelly DJ,Ethier CR

    更新日期:2018-02-01 00:00:00

  • Finite element modeling of coupled diffusion with partitioning in transdermal drug delivery.

    abstract::The finite element method is employed to simulate two-dimensional (axisymmetric) drug diffusion from a finite drug reservoir into the skin. The numerical formulation is based on a general mathematical model for multicomponent nonlinear diffusion that takes into account the coupling effects between the different compon...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-005-5788-6

    authors: Rim JE,Pinsky PM,van Osdol WW

    更新日期:2005-10-01 00:00:00

  • Cue-Signal-Response Analysis in 3D Chondrocyte Scaffolds with Anabolic Stimuli.

    abstract::Articular cartilage is an avascular connective tissue responsible for bearing loads. Cell signaling plays a central role in cartilage homeostasis and tissue engineering by directing chondrocytes to synthesize/degrade the extracellular matrix or promote inflammatory responses. The aim of this paper was to investigate a...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-017-1964-8

    authors: Neidlin M,Korcari A,Macheras G,Alexopoulos LG

    更新日期:2018-02-01 00:00:00

  • Assessment of ventricular contractility during cardiac magnetic resonance imaging examinations using normalized maximal ventricular power.

    abstract::Normalized maximal ventricular power (nPWRmax) is an index of cardiac function which measures the innate blood pumping ability, or contractility, of the left ventricle (LV), and its noninvasive assessment could prove useful in a variety of patients. nPWRmax is defined as the maximum instantaneous product of LV pressur...

    journal_title:Annals of biomedical engineering

    pub_type: 临床试验,杂志文章

    doi:10.1114/1.1415530

    authors: Setser RM,Sayre K,Flacke S,Chia J,Lunn K,Lorenz CH

    更新日期:2001-11-01 00:00:00

  • Computational approach to estimating the effects of blood properties on changes in intra-stent flow.

    abstract::In this study various blood rheological assumptions are numerically investigated for the hemodynamic properties of intra-stent flow. Non-newtonian blood properties have never been implemented in blood coronary stented flow investigation, although its effects appear essential for a correct estimation and distribution o...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-006-9123-7

    authors: Benard N,Perrault R,Coisne D

    更新日期:2006-08-01 00:00:00

  • Digital processing of the current noise evoked by kainate in cerebellar granule cells.

    abstract::Current induced in cultured cerebellar granule cells by the bath application of kainate (500 microM) was measured using the conventional patch-clamp technique. Two different kinds of responses were observed after the agonist perfusion. Some cells exhibited small inward whole-cell currents: 116 +/- 40 pA (7 cells) at a...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02684186

    authors: Cavalcanti S,Zona C

    更新日期:1997-05-01 00:00:00

  • An experimental evaluation of the use of an ensemble average for the calculation of turbulence in pulsatile flow.

    abstract::A comparison was made between turbulence calculated by subtracting an ensemble average from the instantaneous velocity and calculations made with a high pass digital filter. Velocity was measured with a laser Doppler anemometer in vitro in the region of a normal porcine aortic valve and in patients with a hot film ane...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02584215

    authors: Walburn FJ,Sabbah HN,Stein PD

    更新日期:1983-01-01 00:00:00

  • Preparation of chitosan/hydroxyapatite substrates with controllable osteoconductivity tracked by AFM.

    abstract::In this study, cell-material adhesive strength and cellular mechanical properties were measured using atomic force microscopy (AFM) to track cell attachment and osteogenic differentiation. First, chitosan substrates were treated with simulated body fluid (SBF) for various periods, resulting in substrates with differen...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-014-1162-x

    authors: Ho MH,Li CH,Hsiao SW,Thien DV

    更新日期:2015-04-01 00:00:00

  • Monitoring Bone Tissue Engineered (BTE) Constructs Based on the Shifting Metabolism of Differentiating Stem Cells.

    abstract::Ever-increasing demand for bone grafts necessitates the realization of clinical implementation of bone tissue engineered constructs. The predominant hurdle to implementation remains to be securing FDA approval, based on the lack of viable methods for the rigorous monitoring of said constructs. The study presented here...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-017-1937-y

    authors: Simmons AD,Sikavitsas VI

    更新日期:2018-01-01 00:00:00

  • The Application of Digital Volume Correlation (DVC) to Evaluate Strain Predictions Generated by Finite Element Models of the Osteoarthritic Humeral Head.

    abstract::Continuum-level finite element models (FEMs) of the humerus offer the ability to evaluate joint replacement designs preclinically; however, experimental validation of these models is critical to ensure accuracy. The objective of the current study was to quantify experimental full-field strain magnitudes within osteoar...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02549-2

    authors: Kusins J,Knowles N,Columbus M,Oliviero S,Dall'Ara E,Athwal GS,Ferreira LM

    更新日期:2020-12-01 00:00:00

  • Analysis and prediction of left ventricular performance under load changes during cardiac catheterization.

    abstract::The applicability of a computer model, which relates the transmural mechanical distribution in the left ventricle (LV) to its global function at different loading conditions, was evaluated in patients with normal to near normal LV function undergoing cardiac catheterization. Left ventriculography and measurements of a...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02364159

    authors: Abboud L,Beyar R,Battler A,Rat M,Cohen A,Sideman S

    更新日期:1990-01-01 00:00:00

  • Arterial wave propagation phenomena, ventricular work, and power dissipation.

    abstract::The effects of wave propagation phenomena, namely global reflection coefficient (gamma G[omega]) and pulse wave velocity (Cph), are studied in a model of the coupled left ventricle/arterial system. The left ventricle consists of a time-varying elastance, while the arterial system is modeled as a single, uniform, elast...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02584479

    authors: Berger DS,Li JK,Noordergraaf A

    更新日期:1995-11-01 00:00:00

  • Investigation of the Sequential Actions of Doxorubicin and p53 on Tumor Cell Growth Via Branched Polyethylenimine-β-cyclodextrin Conjugates.

    abstract::The combination of gene therapy and chemotherapy has showed increased therapeutic efficacy in the treatment of cancers, but it is not well investigated about the actual coordination pattern between therapeutic gene and chemical drug. In this work, p53/BPEI-β-CD/AD-dox complex was fabricated and employed to investigate...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-016-1627-1

    authors: Xie B,Peng J,Wang S,Zhang X,Nie H

    更新日期:2016-11-01 00:00:00

  • Biomechanical topography of human ankle cartilage.

    abstract::The material properties of normal cadaveric human cartilage in the ankle mortice (tibiotalar articulation) were evaluated to determine a possible etiologic mechanism of cartilage injury of the ankle when an obvious traumatic episode is not present. Using an automated indentation apparatus and the biphasic creep indent...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02584467

    authors: Athanasiou KA,Niederauer GG,Schenck RC Jr

    更新日期:1995-09-01 00:00:00

  • Time-frequency approaches for the detection of interactions and temporal properties in renal autoregulation.

    abstract::We compare the influence of time-frequency methods on analysis of time-varying renal autoregulation properties. Particularly, we examine if detection probabilities are similar for amplitude and frequency modulation for a modulated simulation signal among five time-frequency approaches, and if time-varying changes in s...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-012-0625-1

    authors: Scully CG,Siu KL,Cupples WA,Braam B,Chon KH

    更新日期:2013-01-01 00:00:00

  • Hierarchical CT to Ultrasound Registration of the Lumbar Spine: A Comparison with Other Registration Methods.

    abstract::Three-dimensional (3D) measurement of the spine can provide important information for functional, developmental, diagnostic, and treatment-effect evaluations. However, existing measurement techniques are either 2-dimensional, highly invasive, or involve a high radiation dose, prohibiting their widespread and repeated ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-016-1599-1

    authors: Koo TK,Kwok WE

    更新日期:2016-10-01 00:00:00

  • The role of airway epithelium in replenishment of evaporated airway surface liquid from the human conducting airways.

    abstract::This article presents a multi-scale computational model describing the transport of water vapor and heat within the human conducting airways and its interaction with cellular fluid transport kinetics. This tight coupling between the cell and the evaporative flux allows the periciliary liquid (PCL) depth to be investig...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-0111-6

    authors: Warren NJ,Crampin EJ,Tawhai MH

    更新日期:2010-12-01 00:00:00

  • The Role of Synthetic Extracellular Matrices in Endothelial Progenitor Cell Homing for Treatment of Vascular Disease.

    abstract::Poor vascular homeostasis drives many clinical disorders including diabetes, arthritis, atherosclerosis, and peripheral artery disease. Local tissue ischemia resultant of insufficient blood flow is a potent stimulus for recruitment of endothelial progenitor cells (EPCs). This mobilization and homing is a multi-step pr...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/s10439-015-1400-x

    authors: Williams PA,Silva EA

    更新日期:2015-10-01 00:00:00

  • Arterial luminal curvature and fibrous-cap thickness affect critical stress conditions within atherosclerotic plaque: an in vivo MRI-based 2D finite-element study.

    abstract::High mechanical stress in atherosclerotic plaques at vulnerable sites, called critical stress, contributes to plaque rupture. The site of minimum fibrous cap (FC) thickness (FC(MIN)) and plaque shoulder are well-documented vulnerable sites. The inherent weakness of the FC material at the thinnest point increases the s...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-0078-3

    authors: Teng Z,Sadat U,Li Z,Huang X,Zhu C,Young VE,Graves MJ,Gillard JH

    更新日期:2010-10-01 00:00:00

  • Effects of training on human tracking of electrocutaneous signals.

    abstract::The effects of training on a person's ability to perceive, interpret and utilize information presented via the tactile sense were examined by using a dual-channel electrocutaneous tracking approach. The electrocutaneous code studied was linear pulse rate encoding of information. The stimulus had a pulse width of 200 m...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02367409

    authors: Szeto AY,Chung YM

    更新日期:1986-01-01 00:00:00

  • Validity of Skin, Oral and Tympanic Temperatures During Exercise in the Heat: Effects of Wind and Sweat.

    abstract::This experiment investigates the validity of six thermometers with different measuring sensors, operation and site of application, to estimate core temperature (Tc) in comparison to an ingestible thermometric sensor based on quartz crystal technology. Measurements were obtained before, during and after exercise in the...

    journal_title:Annals of biomedical engineering

    pub_type: 临床试验,杂志文章

    doi:10.1007/s10439-018-02115-x

    authors: Morán-Navarro R,Courel-Ibáñez J,Martínez-Cava A,Conesa-Ros E,Sánchez-Pay A,Mora-Rodriguez R,Pallarés JG

    更新日期:2019-01-01 00:00:00

  • A model for detecting balance impairment and estimating falls risk in the elderly.

    abstract::Traumatic falls are a prevalent and costly threat to elderly adults. Accurate risk assessment is necessary for reducing incidence of falls. The objective of this study was to test the feasibility of a balance impairment detection model using tasks of sample categorization and falls risk estimation. Model design includ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-005-2867-7

    authors: Hahn ME,Chou LS

    更新日期:2005-06-01 00:00:00

  • Effects of chamber shape and fiber orientation on relations between fiber dynamics and chamber dynamics.

    abstract::The function of a chamber depends on its hydrodynamic properties: isometric pressures it can exert in the operating range of distensions, compliances in the operating range of distensions, and wall-displacement resistances in the operating range of distensions. Wall-displacement resistance is the departure of pressure...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02368017

    authors: Regen DM

    更新日期:1988-01-01 00:00:00

  • Strength and electron features of irradiated bone.

    abstract::Radiation applied for therapy and diagnostics damages molecular/atomic couples of biotissues, bones being among them. As a result, electron peculiarities and mechanical behavior of the latter are altered. Correlation between strength of the irradiated bone and its electron features explored due to photo- and exoelectr...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1114/1.1424911

    authors: Dekhtyar Y

    更新日期:2001-12-01 00:00:00

  • Biomechanical Response Targets of Adult Human Ribs in Frontal Impacts.

    abstract::Thorax injuries mainly due to rib fractures have been associated with high rates of morbidity and mortality in motor vehicle crashes. Thoracic biomechanics has been studied extensively, but there are no robust biomechanical response targets for ribs that consider age, sex, body size, and vulnerability factors. The obj...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02613-x

    authors: Kang YS,Kwon HJ,Stammen J,Moorhouse K,Agnew AM

    更新日期:2021-02-01 00:00:00

  • Partitioning of cortical and deep cytoskeleton responses from transient magnetic bead twisting.

    abstract::We attempted to estimate in living adherent epithelial alveolar cells, the degree of structural and mechanical heterogeneity by considering two individualized cytoskeleton components, i.e., a submembranous "cortical" cytoskeleton and a "deep" cytoskeleton (CSK). F-actin structure characterizing each CSK component was ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1616932

    authors: Laurent VM,Fodil R,Cañadas P,Féréol S,Louis B,Planus E,Isabey D

    更新日期:2003-11-01 00:00:00

  • The tendon injury response is influenced by decorin and biglycan.

    abstract::Defining the constituent regulatory molecules in tendon is critical to understanding the process of tendon repair and instructive to the development of novel treatment modalities. The purpose of this study is to define the structural, expressional, and mechanical changes in the tendon injury response, and elucidate th...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-013-0915-2

    authors: Dunkman AA,Buckley MR,Mienaltowski MJ,Adams SM,Thomas SJ,Satchell L,Kumar A,Pathmanathan L,Beason DP,Iozzo RV,Birk DE,Soslowsky LJ

    更新日期:2014-03-01 00:00:00

  • Electrically active bioceramics: a review of interfacial responses.

    abstract::Electrical potentials in mechanically loaded bone have been implicated as signals in the bone remodeling cycle. Recently, interest has grown in exploiting this phenomenon to develop electrically active ceramics for implantation in hard tissue which may induce improved biological responses. Both polarized hydroxyapatit...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/s10439-010-9977-6

    authors: Baxter FR,Bowen CR,Turner IG,Dent AC

    更新日期:2010-06-01 00:00:00

  • Evaluation of three animal models for concussion and serious brain injury.

    abstract::Three animal models were evaluated in this study involving head impacts of the rat, including the Marmarou drop-weight and two momentum-exchange techniques. In series 1, 36 Wistar rats were hit on the side of the free-moving head using Marmarou's 450 g impact mass at 4.4, 5.4, and 6.3 m/s. Head acceleration was measur...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-011-0386-2

    authors: Viano DC,Hamberger A,Bolouri H,Säljö A

    更新日期:2012-01-01 00:00:00