Abstract:
:Percutaneous stent implantation has revolutionized the clinical treatment of occluded arteries. Nevertheless, there is still a large unmet need to prevent re-occlusion after implantation. Consequently, a niche exists for a cost-effective pre-clinical method of evaluating novel interventional devices in human models. Therefore, the development of a coronary model artery offers tremendous potential for the treatment of endothelial cell dysfunction and restenosis. As a first step, we employ tissue-engineering principles to examine the effect of stent deployment upon endothelial cells in a tubular in vitro system capable of replicating the coronary artery biomechanical environment. In particular, the cellular and molecular changes pertaining to inflammation, proliferation, and death were assessed after stent deployment. Real-time quantitative PCR demonstrated increased expression of genes encoding for E-Selectin, ICAM-1, and VCAM-1; markers associated with an inflammatory response in vivo. Further, an increase in the pro-apoptotic protein Bax was paralleled with a decrease in the anti-apoptotic protein Bcl-2; however, apoptotic morphology was not observed. Interestingly, transcription of c-fos increased, whereas Ki67 levels fell over the same period. One hypothesis is that these results are in response to the altered local hemodynamic environment induced by stent deployment. Most significantly, this study highlights the potential of a biomimetic hemodynamic bioreactor combined with a gene expression analysis to evaluate, with greater specificity, the performance and interaction of stents with the endothelial layer in a controlled environment.
journal_name
Ann Biomed Engjournal_title
Annals of biomedical engineeringauthors
Punchard MA,O'Cearbhaill ED,Mackle JN,McHugh PE,Smith TJ,Stenson-Cox C,Barron Vdoi
10.1007/s10439-009-9701-6subject
Has Abstractpub_date
2009-07-01 00:00:00pages
1322-30issue
7eissn
0090-6964issn
1573-9686journal_volume
37pub_type
杂志文章abstract::Microstructural characterization of cardiac tissue and its remodeling in disease is a crucial step in many basic research projects. We present a comprehensive approach for three-dimensional characterization of cardiac tissue at the submicrometer scale. We developed a compression-free mounting method as well as labelin...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-015-1465-6
更新日期:2016-05-01 00:00:00
abstract::Glaucoma is a common optic neuropathy characterized by retinal ganglion cell death. Elevated intraocular pressure (IOP), a key risk factor for glaucoma, leads to significant biomechanical deformation of optic nerve head (ONH) cells and tissues. ONH astrocytes respond to this deformation by transforming to a reactive, ...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-017-1967-5
更新日期:2018-02-01 00:00:00
abstract::The finite element method is employed to simulate two-dimensional (axisymmetric) drug diffusion from a finite drug reservoir into the skin. The numerical formulation is based on a general mathematical model for multicomponent nonlinear diffusion that takes into account the coupling effects between the different compon...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-005-5788-6
更新日期:2005-10-01 00:00:00
abstract::Articular cartilage is an avascular connective tissue responsible for bearing loads. Cell signaling plays a central role in cartilage homeostasis and tissue engineering by directing chondrocytes to synthesize/degrade the extracellular matrix or promote inflammatory responses. The aim of this paper was to investigate a...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-017-1964-8
更新日期:2018-02-01 00:00:00
abstract::Normalized maximal ventricular power (nPWRmax) is an index of cardiac function which measures the innate blood pumping ability, or contractility, of the left ventricle (LV), and its noninvasive assessment could prove useful in a variety of patients. nPWRmax is defined as the maximum instantaneous product of LV pressur...
journal_title:Annals of biomedical engineering
pub_type: 临床试验,杂志文章
doi:10.1114/1.1415530
更新日期:2001-11-01 00:00:00
abstract::In this study various blood rheological assumptions are numerically investigated for the hemodynamic properties of intra-stent flow. Non-newtonian blood properties have never been implemented in blood coronary stented flow investigation, although its effects appear essential for a correct estimation and distribution o...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-006-9123-7
更新日期:2006-08-01 00:00:00
abstract::Current induced in cultured cerebellar granule cells by the bath application of kainate (500 microM) was measured using the conventional patch-clamp technique. Two different kinds of responses were observed after the agonist perfusion. Some cells exhibited small inward whole-cell currents: 116 +/- 40 pA (7 cells) at a...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/BF02684186
更新日期:1997-05-01 00:00:00
abstract::A comparison was made between turbulence calculated by subtracting an ensemble average from the instantaneous velocity and calculations made with a high pass digital filter. Velocity was measured with a laser Doppler anemometer in vitro in the region of a normal porcine aortic valve and in patients with a hot film ane...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/BF02584215
更新日期:1983-01-01 00:00:00
abstract::In this study, cell-material adhesive strength and cellular mechanical properties were measured using atomic force microscopy (AFM) to track cell attachment and osteogenic differentiation. First, chitosan substrates were treated with simulated body fluid (SBF) for various periods, resulting in substrates with differen...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-014-1162-x
更新日期:2015-04-01 00:00:00
abstract::Ever-increasing demand for bone grafts necessitates the realization of clinical implementation of bone tissue engineered constructs. The predominant hurdle to implementation remains to be securing FDA approval, based on the lack of viable methods for the rigorous monitoring of said constructs. The study presented here...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-017-1937-y
更新日期:2018-01-01 00:00:00
abstract::Continuum-level finite element models (FEMs) of the humerus offer the ability to evaluate joint replacement designs preclinically; however, experimental validation of these models is critical to ensure accuracy. The objective of the current study was to quantify experimental full-field strain magnitudes within osteoar...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-020-02549-2
更新日期:2020-12-01 00:00:00
abstract::The applicability of a computer model, which relates the transmural mechanical distribution in the left ventricle (LV) to its global function at different loading conditions, was evaluated in patients with normal to near normal LV function undergoing cardiac catheterization. Left ventriculography and measurements of a...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/BF02364159
更新日期:1990-01-01 00:00:00
abstract::The effects of wave propagation phenomena, namely global reflection coefficient (gamma G[omega]) and pulse wave velocity (Cph), are studied in a model of the coupled left ventricle/arterial system. The left ventricle consists of a time-varying elastance, while the arterial system is modeled as a single, uniform, elast...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/BF02584479
更新日期:1995-11-01 00:00:00
abstract::The combination of gene therapy and chemotherapy has showed increased therapeutic efficacy in the treatment of cancers, but it is not well investigated about the actual coordination pattern between therapeutic gene and chemical drug. In this work, p53/BPEI-β-CD/AD-dox complex was fabricated and employed to investigate...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-016-1627-1
更新日期:2016-11-01 00:00:00
abstract::The material properties of normal cadaveric human cartilage in the ankle mortice (tibiotalar articulation) were evaluated to determine a possible etiologic mechanism of cartilage injury of the ankle when an obvious traumatic episode is not present. Using an automated indentation apparatus and the biphasic creep indent...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/BF02584467
更新日期:1995-09-01 00:00:00
abstract::We compare the influence of time-frequency methods on analysis of time-varying renal autoregulation properties. Particularly, we examine if detection probabilities are similar for amplitude and frequency modulation for a modulated simulation signal among five time-frequency approaches, and if time-varying changes in s...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-012-0625-1
更新日期:2013-01-01 00:00:00
abstract::Three-dimensional (3D) measurement of the spine can provide important information for functional, developmental, diagnostic, and treatment-effect evaluations. However, existing measurement techniques are either 2-dimensional, highly invasive, or involve a high radiation dose, prohibiting their widespread and repeated ...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-016-1599-1
更新日期:2016-10-01 00:00:00
abstract::This article presents a multi-scale computational model describing the transport of water vapor and heat within the human conducting airways and its interaction with cellular fluid transport kinetics. This tight coupling between the cell and the evaporative flux allows the periciliary liquid (PCL) depth to be investig...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-010-0111-6
更新日期:2010-12-01 00:00:00
abstract::Poor vascular homeostasis drives many clinical disorders including diabetes, arthritis, atherosclerosis, and peripheral artery disease. Local tissue ischemia resultant of insufficient blood flow is a potent stimulus for recruitment of endothelial progenitor cells (EPCs). This mobilization and homing is a multi-step pr...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章,评审
doi:10.1007/s10439-015-1400-x
更新日期:2015-10-01 00:00:00
abstract::High mechanical stress in atherosclerotic plaques at vulnerable sites, called critical stress, contributes to plaque rupture. The site of minimum fibrous cap (FC) thickness (FC(MIN)) and plaque shoulder are well-documented vulnerable sites. The inherent weakness of the FC material at the thinnest point increases the s...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-010-0078-3
更新日期:2010-10-01 00:00:00
abstract::The effects of training on a person's ability to perceive, interpret and utilize information presented via the tactile sense were examined by using a dual-channel electrocutaneous tracking approach. The electrocutaneous code studied was linear pulse rate encoding of information. The stimulus had a pulse width of 200 m...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/BF02367409
更新日期:1986-01-01 00:00:00
abstract::This experiment investigates the validity of six thermometers with different measuring sensors, operation and site of application, to estimate core temperature (Tc) in comparison to an ingestible thermometric sensor based on quartz crystal technology. Measurements were obtained before, during and after exercise in the...
journal_title:Annals of biomedical engineering
pub_type: 临床试验,杂志文章
doi:10.1007/s10439-018-02115-x
更新日期:2019-01-01 00:00:00
abstract::Traumatic falls are a prevalent and costly threat to elderly adults. Accurate risk assessment is necessary for reducing incidence of falls. The objective of this study was to test the feasibility of a balance impairment detection model using tasks of sample categorization and falls risk estimation. Model design includ...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-005-2867-7
更新日期:2005-06-01 00:00:00
abstract::The function of a chamber depends on its hydrodynamic properties: isometric pressures it can exert in the operating range of distensions, compliances in the operating range of distensions, and wall-displacement resistances in the operating range of distensions. Wall-displacement resistance is the departure of pressure...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/BF02368017
更新日期:1988-01-01 00:00:00
abstract::Radiation applied for therapy and diagnostics damages molecular/atomic couples of biotissues, bones being among them. As a result, electron peculiarities and mechanical behavior of the latter are altered. Correlation between strength of the irradiated bone and its electron features explored due to photo- and exoelectr...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章,评审
doi:10.1114/1.1424911
更新日期:2001-12-01 00:00:00
abstract::Thorax injuries mainly due to rib fractures have been associated with high rates of morbidity and mortality in motor vehicle crashes. Thoracic biomechanics has been studied extensively, but there are no robust biomechanical response targets for ribs that consider age, sex, body size, and vulnerability factors. The obj...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-020-02613-x
更新日期:2021-02-01 00:00:00
abstract::We attempted to estimate in living adherent epithelial alveolar cells, the degree of structural and mechanical heterogeneity by considering two individualized cytoskeleton components, i.e., a submembranous "cortical" cytoskeleton and a "deep" cytoskeleton (CSK). F-actin structure characterizing each CSK component was ...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1114/1.1616932
更新日期:2003-11-01 00:00:00
abstract::Defining the constituent regulatory molecules in tendon is critical to understanding the process of tendon repair and instructive to the development of novel treatment modalities. The purpose of this study is to define the structural, expressional, and mechanical changes in the tendon injury response, and elucidate th...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-013-0915-2
更新日期:2014-03-01 00:00:00
abstract::Electrical potentials in mechanically loaded bone have been implicated as signals in the bone remodeling cycle. Recently, interest has grown in exploiting this phenomenon to develop electrically active ceramics for implantation in hard tissue which may induce improved biological responses. Both polarized hydroxyapatit...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章,评审
doi:10.1007/s10439-010-9977-6
更新日期:2010-06-01 00:00:00
abstract::Three animal models were evaluated in this study involving head impacts of the rat, including the Marmarou drop-weight and two momentum-exchange techniques. In series 1, 36 Wistar rats were hit on the side of the free-moving head using Marmarou's 450 g impact mass at 4.4, 5.4, and 6.3 m/s. Head acceleration was measur...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-011-0386-2
更新日期:2012-01-01 00:00:00