A general framework for characterizing studies of brain interface technology.

Abstract:

:The development of brain interface (BI) technology continues to attract researchers with a wide range of backgrounds and expertise. Though the BI community is committed to accurate and objective evaluation of methods, systems, and technology, the very diversity of the methods and terminology used in the field hinders understanding and impairs technology cross-fertilization and cross-group validation of findings. Underlying this dilemma is a lack of common perspective and language. As seen in our previous works in this area, our approach to remedy this problem is to propose language in the form of taxonomy and functional models. Our intent is to document and validate our best thinking in this area and publish a perspective that will stimulate discussion. We encourage others to do the same with the belief that focused discussion on language issues will accelerate the inherently slow natural evolution of language selection and thus alleviate related problems. In this work, we propose a theoretical framework for describing BI-technology-related studies. The proposed framework is based on the theoretical concepts and terminology from classical science, assistive technology development, human-computer interaction, and previous BI-related works. Using a representative set of studies from the literature, the proposed BI study framework was shown to be complete and appropriate perspective for thoroughly characterizing a BI study. We have also demonstrated that this BI study framework is useful for (1) objectively reviewing existing BI study designs and results, (2) comparing designs and results of multiple BI studies, (3) designing new studies or objectively reporting BI study results, and (4) facilitating intra- and inter-group communication and the education of new researchers. As such, it forms a sound and appropriate basis for community discussion.

journal_name

Ann Biomed Eng

authors

Mason SG,Jackson MM,Birch GE

doi

10.1007/s10439-005-7706-3

subject

Has Abstract

pub_date

2005-11-01 00:00:00

pages

1653-70

issue

11

eissn

0090-6964

issn

1573-9686

journal_volume

33

pub_type

杂志文章
  • Effect of cell-cell interactions on the observable strength of adhesion of sheets of cells.

    abstract::Previous research in cellular adhesion has focused primarily on studying isolated cells under conditions where cells do not interact with each other. However, in vivo cells form sheets where both cell-substratum and cell-cell interactions contribute to the overall adhesive behavior. Our understanding of how cell-cell ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.178

    authors: Peel MM,DiMilla PA

    更新日期:1999-03-01 00:00:00

  • Can molecular imaging enable personalized diagnostics? An example using magnetomotive photoacoustic imaging.

    abstract::The advantages of photoacoustic (PA) imaging, including low cost, non-ionizing operation, and sub-mm spatial resolution at centimeters depth, make it a promising modality to probe nanoparticle-targeted abnormalities in real time at cellular and molecular levels. However, detecting rare cell types in a heterogeneous ba...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/s10439-013-0901-8

    authors: O'Donnell M,Wei CW,Xia J,Pelivanov I,Jia C,Huang SW,Hu X,Gao X

    更新日期:2013-11-01 00:00:00

  • How crouch gait can dynamically induce stiff-knee gait.

    abstract::Children with cerebral palsy frequently experience foot dragging and tripping during walking due to a lack of adequate knee flexion in swing (stiff-knee gait). Stiff-knee gait is often accompanied by an overly flexed knee during stance (crouch gait). Studies on stiff-knee gait have mostly focused on excessive knee mus...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-9952-2

    authors: van der Krogt MM,Bregman DJ,Wisse M,Doorenbosch CA,Harlaar J,Collins SH

    更新日期:2010-04-01 00:00:00

  • Two-dimensional dynamic simulation of platelet activation during mechanical heart valve closure.

    abstract::A major drawback in the operation of mechanical heart valve prostheses is thrombus formation in the near valve region. Detailed flow analysis in this region during the valve closure phase is of interest in understanding the relationship between shear stress and platelet activation. A fixed-grid Cartesian mesh flow sol...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-006-9194-5

    authors: Krishnan S,Udaykumar HS,Marshall JS,Chandran KB

    更新日期:2006-10-01 00:00:00

  • Bimodal analysis of mammary epithelial cell migration in two dimensions.

    abstract::Cell migration paths of mammary epithelial cells (expressing different versions of the promigratory tyrosine kinase receptor Her2/Neu) were analyzed within a bimodal framework that is a generalization of the run-and-tumble description applicable to bacterial migration. The mammalian cell trajectories were segregated i...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-008-9592-y

    authors: Potdar AA,Lu J,Jeon J,Weaver AM,Cummings PT

    更新日期:2009-01-01 00:00:00

  • In vitro characterization of a compliant biodegradable scaffold with a novel bioreactor system.

    abstract::The influence of scaffold compliance on blood vessel tissue engineering remains unclear and compliance mismatch issues are important to an in vivo tissue-engineering approach. We have designed and constructed a modular bioreactor system that is capable of imparting pulsatile fluid flow while simultaneously measuring v...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-007-9304-z

    authors: Webb AR,Macrie BD,Ray AS,Russo JE,Siegel AM,Glucksberg MR,Ameer GA

    更新日期:2007-08-01 00:00:00

  • Creep deformation of the human trunk in response to prolonged and repetitive flexion: measuring and modeling the effect of external moment and flexion rate.

    abstract::While viscoelastic responses of isolated trunk soft tissues have been characterized in earlier studies, the effects of external loading and flexion rate on these responses in the intact human trunk are largely unknown. Two experiments were conducted to measure trunk viscoelastic behaviors, one involving prolonged flex...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-013-0797-3

    authors: Toosizadeh N,Nussbaum MA

    更新日期:2013-06-01 00:00:00

  • A fuzzy pattern recognition method to classify esophageal motility records.

    abstract::Analysis and classification of esophageal motility records were investigated using signal processing and fuzzy-set pattern recognition techniques. A set of parameters has been extracted from the raw records and has previously been used as characterizing features. Improvements to these procedures were obtained by extra...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02368227

    authors: Abou-Chadi FE,Ezzat FA,Sif el-Din AA

    更新日期:1994-01-01 00:00:00

  • Length-Change Patterns of the Collateral Ligaments During Functional Activities After Total Knee Arthroplasty.

    abstract::This study aimed to quantify the elongation patterns of the collateral ligaments following TKA during functional activities of daily living. Using mobile video-fluoroscopy to capture radiographic images of the knee in a group of six patients, each with an ultra-congruent knee implant, tibiofemoral kinematics were reco...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02459-3

    authors: Hosseini Nasab SH,Smith CR,Schütz P,Damm P,Trepczynski A,List R,Taylor WR

    更新日期:2020-04-01 00:00:00

  • Regional distribution of aerosol deposition in rat lungs using magnetic resonance imaging.

    abstract::The toxic or therapeutic effect of an inhaled aerosol is highly dependent upon the site and extent of deposition in the lung. A novel MRI-based method was used to quantify the spatial distribution of particles in the rat lung. Rats were exposed to 0.95 μm-diameter iron oxide particles in a controlled manner (N = 6) or...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-013-0745-2

    authors: Oakes JM,Scadeng M,Breen EC,Prisk GK,Darquenne C

    更新日期:2013-05-01 00:00:00

  • Dual energy CT scanning for analysis of brain damage due to X-irradiation.

    abstract::Therapeutic irradiation is commonly used in the treatment of malignant brain tumors and has the potential to cause severe injury to normal tissues adjacent to a lesion. Computed tomography (CT) can be used not only to visualize tissue damage but to monitor the development of a lesion using advanced quantitative CT tec...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02410288

    authors: Russell LB,Fike JR,Cann CE,Süsskind C

    更新日期:1984-01-01 00:00:00

  • Magnetic (eddy-current) electroventilation in the dog.

    abstract::Magnetic (eddy-current) stimulation of the inspiratory motor nerves in the neck of the anesthetized dog was achieved. Using a 10-turn coil wound around the base of the neck and a train of pulses (25/s), inspiration was produced by tetanic contraction of the inspiratory muscles. The volume of air inspired increased wit...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02368176

    authors: Geddes LA,Mouchawar G,Bourland JD,ElAbbady T,Nyenhuis J

    更新日期:1993-05-01 00:00:00

  • Masquelet Technique: Effects of Spacer Material and Micro-topography on Factor Expression and Bone Regeneration.

    abstract::We and others have shown that changing surface characteristics of the spacer implanted during the first Masquelet stage alters some aspects of membrane development. Previously we demonstrated that titanium (TI) spacers create membranes that are better barriers to movement of solutes > 70 kDa in size than polymethyl me...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-018-02137-5

    authors: Toth Z,Roi M,Evans E,Watson JT,Nicolaou D,McBride-Gagyi S

    更新日期:2019-01-01 00:00:00

  • Developments and Control of Biocompatible Conducting Polymer for Intracorporeal Continuum Robots.

    abstract::Dexterity of robots is highly required when it comes to integration for medical applications. Major efforts have been conducted to increase the dexterity at the distal parts of medical robots. This paper reports on developments toward integrating biocompatible conducting polymers (CP) into inherently dexterous concent...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-018-2038-2

    authors: Chikhaoui MT,Benouhiba A,Rougeot P,Rabenorosoa K,Ouisse M,Andreff N

    更新日期:2018-10-01 00:00:00

  • Pulsatile flow in tubes of elliptic cross sections.

    abstract::The compression of blood vessels by surrounding tissue is an important problem in hemodynamics, most prominently in studies relating to the heart. In this study we consider a long tube of elliptic cross section as an idealization of the geometry of a compressed blood vessel. An exact solution of the governing equation...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.106

    authors: Haslam M,Zamir M

    更新日期:1998-09-01 00:00:00

  • Flow visualization in mechanical heart valves: occluder rebound and cavitation potential.

    abstract::High density particle image velocimetry, with spatial resolution of O(1 mm), was used to measure the effect of occluder rebound on the flow field near a Bjork-Shiley Monostrut tilting-disk mitral valve. The ability to measure two velocity components over an entire plane simultaneously provides a very different insight...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.281

    authors: Kini V,Bachmann C,Fontaine A,Deutsch S,Tarbell JM

    更新日期:2000-04-01 00:00:00

  • Contourlet-based features for computerized tumor detection in capsule endoscopy images.

    abstract::This article presents a computer-aided detection system for capsule endoscopy (CE) images using contourlet-based color textural features to recognize tumors in the digestive tract. As tumor exhibits rich information in color texture, a novel color texture feature based on contourlet transform is proposed to describe c...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-011-0380-8

    authors: Li B,Meng MQ

    更新日期:2011-12-01 00:00:00

  • Quasiperiodic circus movement in a loop model of cardiac tissue: multistability and low dimensional equivalence.

    abstract::This paper discusses the dynamics of the circus movement around a one-dimensional continuous and uniform loop of model cardiac cells. The membrane ionic currents are represented by a modified Beeler-Reuter formulation. The description of the quasiperiodic regimes initiated in a previous paper is completed and their eq...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1289458

    authors: Vinet A

    更新日期:2000-07-01 00:00:00

  • Tauberian-prony feature extraction technique for esophageal motility patterns.

    abstract::For the esophageal contractile activity recorded during swallowing, a feature extraction scheme has been developed. It recognizes the time, duration, and amplitudes of local peaks for each peristaltic wave. The method is based on the Tauberian approximation for modeling waveforms as a sum of identically shaped pulses ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02367607

    authors: Abou-Chadi FE,Ezzat FA,Gad-Elhak N,Sif el-Din AA

    更新日期:1993-03-01 00:00:00

  • Rat aortic smooth muscle cells contract in response to serum and its components in a calcium independent manner.

    abstract::Diluted serum provides a model of interstitial fluid that can be used to study the response of smooth muscle cells (SMCs) to interstitial flow. The effect of serum and some of its components on SMC contraction (area reduction) and intracellular calcium ([Ca2+]i) response were characterized in rat aortic SMC in vitro. ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-004-7820-7

    authors: Ainslie K,Shi ZD,Garanich JS,Tarbell JM

    更新日期:2004-12-01 00:00:00

  • A Wearable Magnet-Based System to Assess Activity and Joint Flexion in Humans and Large Animals.

    abstract::Functional outcomes, such as joint flexion and gait, are important indicators of efficacy in musculoskeletal research. Current technologies that objectively assess these parameters, including visual tracking systems and force plates, are challenging to deploy in long-term translational and clinical studies. To that en...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-018-2105-8

    authors: Qu F,Stoeckl BD,Gebhard PM,Hullfish TJ,Baxter JR,Mauck RL

    更新日期:2018-12-01 00:00:00

  • An evaluation of population D-optimal designs via pharmacokinetic simulations.

    abstract::One goal of large scale clinical trials is to determine how a drug is processed by, and cleared from, the human body [i.e., its pharmacokinetic (PK) properties] and how these PK properties differ between individuals in a population (i.e., its population PK properties). Due to the high cost of these studies and the lim...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1533074

    authors: Hooker AC,Foracchia M,Dodds MG,Vicini P

    更新日期:2003-01-01 00:00:00

  • Cellularized microcarriers as adhesive building blocks for fabrication of tubular tissue constructs.

    abstract::To meet demands of vascular reconstruction, there is a need for prosthetic alternatives to natural blood vessels. Here we explored a new conduit fabrication approach. Macroporous, gelatin microcarriers laden with human umbilical vein endothelial cells and aortic smooth muscle cells were dispensed into tubular agarose ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-013-0883-6

    authors: Twal WO,Klatt SC,Harikrishnan K,Gerges E,Cooley MA,Trusk TC,Zhou B,Gabr MG,Shazly T,Lessner SM,Markwald RR,Argraves WS

    更新日期:2014-07-01 00:00:00

  • MEG connectivity analysis in patients with Alzheimer's disease using cross mutual information and spectral coherence.

    abstract::Alzheimer's disease (AD) is an irreversible brain disorder which represents the most common form of dementia in western countries. An early and accurate diagnosis of AD would enable to develop new strategies for managing the disease; however, nowadays there is no single test that can accurately predict the development...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-0155-7

    authors: Alonso JF,Poza J,Mañanas MA,Romero S,Fernández A,Hornero R

    更新日期:2011-01-01 00:00:00

  • In-Vitro Detection of Small Isolated Cartilage Defects: Intravascular Ultrasound Vs. Optical Coherence Tomography.

    abstract::This experimental work focused on the sensor selection for the development of a needle-like instrument to treat small isolated cartilage defects with hydrogels. The aim was to identify the most accurate and sensitive imaging method to determine the location and size of defects compared to a gold standard (µCT). Only i...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-018-2073-z

    authors: Horeman T,Buiter EC,Pouran B,Stijntjes M,Dankelman J,Tuijthof GJM

    更新日期:2018-11-01 00:00:00

  • Static magnetic fields promote osteoblast-like cells differentiation via increasing the membrane rigidity.

    abstract::The aim of this study was to test the differentiative effects of osteoblasts after treatment with a static magnetic field (SMF). MG63 osteoblast-like cells were exposed to a 0.4-T SMF. The differentiation markers were assessed by observing the changes in alkaline phosphatase activity and electron microscopy images. Me...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-007-9370-2

    authors: Chiu KH,Ou KL,Lee SY,Lin CT,Chang WJ,Chen CC,Huang HM

    更新日期:2007-11-01 00:00:00

  • Effect of Drilling Techniques on Microcracks and Pull-Out Strength of Cortical Screw Fixed in Human Tibia: An In-Vitro Study.

    abstract::The strength between the cortical screw and bone following an orthopaedic implant surgery is an important determinant for the success of osteosynthesis. An excessive axial cutting force during drilling produces microcracks in the bone surface, resulting in reduced strength between the screw and bone, resulting in loos...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02565-2

    authors: Singh RP,Gupta V,Pandey PM,Mridha AR

    更新日期:2021-01-01 00:00:00

  • User customization of the feature generator of an asynchronous brain interface.

    abstract::A study that customizes the feature generator parameters of an asynchronous Brain Interface (BI) is discussed. The goal is to detect the presence of a certain pattern, in the ongoing EEG, associated with a specific movement and to improve the system's performance. Results of this study show that customization mostly b...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-006-9097-5

    authors: Bashashati A,Fatourechi M,Ward RK,Birch GE

    更新日期:2006-06-01 00:00:00

  • Simultaneous Measurement of Contraction and Calcium Transients in Stem Cell Derived Cardiomyocytes.

    abstract::Induced pluripotent stem cell derived cardiomyocytes (iPSC-CM) provide a powerful platform for disease modeling and drug development in vitro. Traditionally, electrophysiological methods or fluorescent dyes (e.g. calcium) have been used in their functional characterization. Recently, video microscopy has enabled non-i...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-017-1933-2

    authors: Ahola A,Pölönen RP,Aalto-Setälä K,Hyttinen J

    更新日期:2018-01-01 00:00:00

  • Electrically active bioceramics: a review of interfacial responses.

    abstract::Electrical potentials in mechanically loaded bone have been implicated as signals in the bone remodeling cycle. Recently, interest has grown in exploiting this phenomenon to develop electrically active ceramics for implantation in hard tissue which may induce improved biological responses. Both polarized hydroxyapatit...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/s10439-010-9977-6

    authors: Baxter FR,Bowen CR,Turner IG,Dent AC

    更新日期:2010-06-01 00:00:00