Can molecular imaging enable personalized diagnostics? An example using magnetomotive photoacoustic imaging.

Abstract:

:The advantages of photoacoustic (PA) imaging, including low cost, non-ionizing operation, and sub-mm spatial resolution at centimeters depth, make it a promising modality to probe nanoparticle-targeted abnormalities in real time at cellular and molecular levels. However, detecting rare cell types in a heterogeneous background with strong optical scattering and absorption remains a big challenge. For example, differentiating circulating tumor cells in vivo (typically fewer than 10 cells/mL for an active tumor) among billions of erythrocytes in the blood is nearly impossible. In this paper, a newly developed technique, magnetomotive photoacoustic (mmPA) imaging, which can greatly increase the sensitivity and specificity of sensing targeted cells or molecular interactions, is reviewed. Its primary advantage is suppression of background signals through magnetic enrichment/manipulation with simultaneous PA detection of magnetic contrast agent targeted objects. Results from phantom and in vitro studies demonstrate the capability of mmPA imaging to differentiate regions targeted with magnetic nanoparticles from the background, and to trap and sensitively detect targeted cells at a concentration of a single cell per milliliter in a flow system mimicking a human peripheral artery. This technique provides an example of the ways in which molecular imaging can potentially enable robust molecular diagnosis and treatment, and accelerate the translation of molecular medicine into the clinic.

journal_name

Ann Biomed Eng

authors

O'Donnell M,Wei CW,Xia J,Pelivanov I,Jia C,Huang SW,Hu X,Gao X

doi

10.1007/s10439-013-0901-8

subject

Has Abstract

pub_date

2013-11-01 00:00:00

pages

2237-47

issue

11

eissn

0090-6964

issn

1573-9686

journal_volume

41

pub_type

杂志文章,评审
  • Dynamics of cardiac period responses after prolonged vagal stimulation in the dog.

    abstract::In 12 dogs anesthetised with alpha-chloralose and urethane, and beta-adrenergic blocked with propranolol, the cervical vagi were stimulated for 60 seconds with supramaximal constant current pulses at frequencies between 2.0 and 10 Hz. The time course of the recovery of the cardiac period response, after cessation of v...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02584303

    authors: Celler BG,Lovell NH

    更新日期:1991-01-01 00:00:00

  • Nanoparticle-Mediated TGF-β Release from Microribbon-Based Hydrogels Accelerates Stem Cell-Based Cartilage Formation In Vivo.

    abstract::Conventional nanoporous hydrogels often lead to slow cartilage deposition by MSCs in 3D due to physical constraints and requirement for degradation. Our group has recently reported macroporous gelatin microribbon (μRB) hydrogels, which substantially accelerate MSC-based cartilage formation in vitro compared to convent...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02522-z

    authors: Barati D,Gegg C,Yang F

    更新日期:2020-07-01 00:00:00

  • Measurement of Strain in Cardiac Myocytes at Micrometer Scale Based on Rapid Scanning Confocal Microscopy and Non-Rigid Image Registration.

    abstract::Measurement of cell shortening is an important technique for assessment of physiology and pathophysiology of cardiac myocytes. Many types of heart disease are associated with decreased myocyte shortening, which is commonly caused by structural and functional remodeling. Here, we present a new approach for local measur...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-016-1593-7

    authors: Lichter J,Li H,Sachse FB

    更新日期:2016-10-01 00:00:00

  • Analysis of the longitudinal and radial resistivity measurements of the nerve trunk.

    abstract::Of the many models of peripheral nerve in the literature, essentially all have relied on experimentally derived values for the anisotropic resistivity of the nerve bundle interstitial space. This paper is a comprehensive mathematical analysis of the most referenced experiment for the longitudinal and radial resistivit...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02368054

    authors: Altman KW,Plonsey R

    更新日期:1989-01-01 00:00:00

  • On the Compressibility of Arterial Tissue.

    abstract::Arterial tissue is commonly assumed to be incompressible. While this assumption is convenient for both experimentalists and theorists, the compressibility of arterial tissue has not been rigorously investigated. In the current study we present an experimental-computational methodology to determine the compressibility ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1417-1

    authors: Nolan DR,McGarry JP

    更新日期:2016-04-01 00:00:00

  • The tendon injury response is influenced by decorin and biglycan.

    abstract::Defining the constituent regulatory molecules in tendon is critical to understanding the process of tendon repair and instructive to the development of novel treatment modalities. The purpose of this study is to define the structural, expressional, and mechanical changes in the tendon injury response, and elucidate th...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-013-0915-2

    authors: Dunkman AA,Buckley MR,Mienaltowski MJ,Adams SM,Thomas SJ,Satchell L,Kumar A,Pathmanathan L,Beason DP,Iozzo RV,Birk DE,Soslowsky LJ

    更新日期:2014-03-01 00:00:00

  • Simultaneous Measurement of Contraction and Calcium Transients in Stem Cell Derived Cardiomyocytes.

    abstract::Induced pluripotent stem cell derived cardiomyocytes (iPSC-CM) provide a powerful platform for disease modeling and drug development in vitro. Traditionally, electrophysiological methods or fluorescent dyes (e.g. calcium) have been used in their functional characterization. Recently, video microscopy has enabled non-i...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-017-1933-2

    authors: Ahola A,Pölönen RP,Aalto-Setälä K,Hyttinen J

    更新日期:2018-01-01 00:00:00

  • Changes of flow characteristics by stenting in aneurysm models: influence of aneurysm geometry and stent porosity.

    abstract::An endovascular technique using a stent has been developed and successfully applied in the treatment of wide neck aneurysms. A stent can facilitate thrombosis in the aneurysm pouch while maintaining biocompatible passage of the parent artery. Insertion of the stent changes the flow characteristics inside the aneurysm ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1500406

    authors: Rhee K,Han MH,Cha SH

    更新日期:2002-07-01 00:00:00

  • Progression of abdominal aortic aneurysm towards rupture: refining clinical risk assessment using a fully coupled fluid-structure interaction method.

    abstract::Rupture of abdominal aortic aneurysm (AAA) is associated with high mortality rates. Risk of rupture is multi-factorial involving AAA geometric configuration, vessel tortuosity, and the presence of intraluminal pathology. Fluid structure interaction (FSI) simulations were conducted in patient based computed tomography ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-014-1224-0

    authors: Xenos M,Labropoulos N,Rambhia S,Alemu Y,Einav S,Tassiopoulos A,Sakalihasan N,Bluestein D

    更新日期:2015-01-01 00:00:00

  • Electrical impedance cardiography using artificial neural networks.

    abstract::This study evaluates the use of artificial neural networks to estimate stroke volume from pre-processed, thoracic impedance plethysmograph signals from 20 healthy subjects. Standard back-propagation was used to train the networks, with Doppler stroke volume estimates as the desired output. The trained networks were th...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.47

    authors: Mulavara AP,Timmons WD,Nair MS,Gupta V,Kumar AA,Taylor BC

    更新日期:1998-07-01 00:00:00

  • Distribution of internal strains around bony prominences in pigs.

    abstract::Deep tissue injury (DTI) is a type of pressure ulcer in which tissue breakdown initiates at the bone-muscle interface under intact skin. Excessive deformation in the soft tissue, particularly around bony prominences, is believed to be one of the causes leading to the development of DTI. The main goal of this study was...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-012-0539-y

    authors: Solis LR,Liggins AB,Seres P,Uwiera RR,Poppe NR,Pehowich E,Thompson RB,Mushahwar VK

    更新日期:2012-08-01 00:00:00

  • Characterizing the variability of system kernel and input estimates.

    abstract::The identification of the input to, or kernels of, a system using nonparametric representations and least-squares estimation is becoming increasingly popular. Nonparametric representations avoid making a priori assumptions about the input or having detailed knowledge about the system, and only need to guarantee known ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.110

    authors: Verotta D

    更新日期:1998-09-01 00:00:00

  • Effect of Drilling Techniques on Microcracks and Pull-Out Strength of Cortical Screw Fixed in Human Tibia: An In-Vitro Study.

    abstract::The strength between the cortical screw and bone following an orthopaedic implant surgery is an important determinant for the success of osteosynthesis. An excessive axial cutting force during drilling produces microcracks in the bone surface, resulting in reduced strength between the screw and bone, resulting in loos...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02565-2

    authors: Singh RP,Gupta V,Pandey PM,Mridha AR

    更新日期:2021-01-01 00:00:00

  • Intrinsic oscillations and discharge regularity of units in the dorsal cochlear nucleus (DCN) of the barbiturate anesthetized gerbil.

    abstract::Spike discharge patterns showing intrinsic oscillations (IOs) have been reported in units in the dorsal cochlear nucleus (DCN) of the decerebrate cat. These oscillations are related to the regularity of a unit's discharge rate and may be important for pitch perception. A DCN unit's regularity can be affected by severa...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.96

    authors: Gdowski GT,Voigt HF

    更新日期:1998-05-01 00:00:00

  • Signaling in the motility responses of the human neutrophil.

    abstract::The neutrophil has developed into one of the most efficient vertebrate motile cells. It migrates through tissues, where it encounters multiple chemoattractant signals with complex spatial and temporal characteristics. The directional movement of the neutrophil is signaled by the binding of chemoattractants and chemoki...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1114/1.1477446

    authors: Zhelev DV,Alteraifi A

    更新日期:2002-03-01 00:00:00

  • Multi-scale computational models of pro-angiogenic treatments in peripheral arterial disease.

    abstract::The induction of angiogenesis is a promising therapeutic strategy for the amelioration of peripheral arterial disease (PAD). This occlusive disease results in muscle ischemia, and neovascularization is a route to increasing the perfusion in the tissue. The vascular endothelial growth factor (VEGF) family of potent pro...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-007-9303-0

    authors: Mac Gabhann F,Ji JW,Popel AS

    更新日期:2007-06-01 00:00:00

  • Genetics of energetics: transcriptional responses in cardiac metabolism.

    abstract::Recent evidence suggests that energy substrate metabolism forms the link between gene expression and contractile function of the heart. This hypothesis draws on three seemingly unconnected observations, made in 1941 by three different investigators. The first gave rise to the concept of the dynamic nature of body cons...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1114/1.1312187

    authors: Taegtmeyer H

    更新日期:2000-08-01 00:00:00

  • Phospholipids identified on the pericardium and their ability to impart boundary lubrication.

    abstract::Phospholipids have been identified by thin-layer chromatography in appreciable quantities in pericardial fluid taken from 12 dogs and found to include sphingomyelin and phosphatidylcholines, -ethanolamines, -inositols and -serines--the cholines predominating. The extracts, the synthetic surfactants and a mixture of sy...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02584258

    authors: Hills BA,Butler BD

    更新日期:1985-01-01 00:00:00

  • Retinal vascular permeability determined by dual-tracer fluorescence angiography.

    abstract::Diabetic retinopathy is the leading cause of blindness in working age individuals in the United States. Breakdown of the blood-retinal barrier is one of the earliest events in the progression of diabetic retinopathy. Ideally, therapeutic measures would be directed at this early stage, but there are few sensitive, quan...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1385809

    authors: Russ PK,Gaylord GM,Haselton FR

    更新日期:2001-08-01 00:00:00

  • Measurement of three-dimensional anisotropic diffusion by multiphoton fluorescence recovery after photobleaching.

    abstract::The multiphoton fluorescence recovery after photobleaching (MP-FRAP) technique has been developed to measure the three-dimensional (3D) solute diffusion within biological systems. However, current 3D MP-FRAP models are based on isotropic diffusion and spatial domain analysis. The 3D anisotropic diffusion and frequency...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-013-0939-7

    authors: Shi C,Cisewski SE,Bell PD,Yao H

    更新日期:2014-03-01 00:00:00

  • Left-right asymmetry of visual evoked potentials in brain-damaged patients: a mathematical model and experimental results.

    abstract::The left-right asymmetry in the potential amplitude on the scalp was studied in poststroke patients by using flash visual evoked potential (VEP) and a numerical two-dimensional model of the head. The left-right asymmetry of the VEP was measured in three patients after thrombosis, in one after hemorrhage, and in one he...

    journal_title:Annals of biomedical engineering

    pub_type: 临床试验,杂志文章

    doi:10.1007/BF02770997

    authors: Abboud S,Bar L,Rosenfeld M,Ring H,Glass I

    更新日期:1996-01-01 00:00:00

  • An Integrated In Vitro-In Silico Approach for Silver Nanoparticle Dosimetry in Cell Cultures.

    abstract::Potential human and environmental hazards resulting from the exposure of living organisms to silver nanoparticles (Ag NPs) have been the subject of intensive discussion in the last decade. Despite the growing use of Ag NPs in biomedical applications, a quantification of the toxic effects as a function of the total sil...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02449-5

    authors: Poli D,Mattei G,Ucciferri N,Ahluwalia A

    更新日期:2020-04-01 00:00:00

  • Behavior of human mesenchymal stem cells in fibrin-based vascular tissue engineering constructs.

    abstract::A limitation of current tissue engineering vascular graft technology is the provision of an expandable, autologous cell source. By harnessing the multipotency of mesenchymal stem cells (MSC), it is hoped that functional vascular cells can be produced. To date, a range of 2D and 3D environments have been investigated f...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-9912-x

    authors: O'Cearbhaill ED,Murphy M,Barry F,McHugh PE,Barron V

    更新日期:2010-03-01 00:00:00

  • The Effects of 4%Fe on the Performance of Pure Zinc as Biodegradable Implant Material.

    abstract::The efforts to develop structural materials for biodegradable metal implants have lately shifted their focus from Magnesium and Iron base alloys towards Zinc. This was mainly due to the accelerated corrosion rate of Mg that is accompanied by hydrogen gas evolution, formation of voluminous iron oxide products with redu...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-019-02245-w

    authors: Kafri A,Ovadia S,Yosafovich-Doitch G,Aghion E

    更新日期:2019-06-01 00:00:00

  • Nanoscale intracellular organization and functional architecture mediating cellular behavior.

    abstract::Cells function based on a complex set of interactions that control pathways resulting in ultimate cell fates including proliferation, differentiation, and apoptosis. The inter-workings of this immensely dense network of intracellular molecules are influenced by more than random protein and nucleic acid distribution wh...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/s10439-005-9008-1

    authors: LeDuc PP,Bellin RR

    更新日期:2006-01-01 00:00:00

  • Assessment of daily-life reaching performance after stroke.

    abstract::For an optimal guidance of the rehabilitation therapy of stroke patients in an in-home setting, objective, and patient-specific performance assessment of arm movements is needed. In this study, metrics of hand movement relative to the pelvis and the sternum were estimated in 13 stroke subjects using a full body ambula...

    journal_title:Annals of biomedical engineering

    pub_type: 临床试验,杂志文章

    doi:10.1007/s10439-014-1198-y

    authors: van Meulen FB,Reenalda J,Buurke JH,Veltink PH

    更新日期:2015-02-01 00:00:00

  • Electrospinning of nanocomposite fibrillar tubular and flat scaffolds with controlled fiber orientation.

    abstract::Electrospinning was used in innovative electrospinning rigs to obtain tubular and flat fibrous structures with controlled fiber orientation with the aim to be used as scaffolds for biomedical applications, more specifically in the tissue engineering of vascular and orthopedic grafts. Gelatine and hydroxyapatite (HA)-g...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-011-0350-1

    authors: Salifu AA,Nury BD,Lekakou C

    更新日期:2011-10-01 00:00:00

  • Blood pressure measurement in noise intensive environments using adaptive interference cancellation.

    abstract::The traditional auscultatory technique and current methodologies for measuring human blood pressure are limited when used in situations where extreme vibration or acoustic noise is present. In this study, human subjects were used to establish the effectiveness of a novel adaptive blood pressure monitoring (ABPM) syste...

    journal_title:Annals of biomedical engineering

    pub_type: 临床试验,杂志文章

    doi:10.1114/1.1481051

    authors: Pinto L,Dhanantwari A,Wong W,Stergiopoulos S,Maris M

    更新日期:2002-05-01 00:00:00

  • The Application of Digital Volume Correlation (DVC) to Evaluate Strain Predictions Generated by Finite Element Models of the Osteoarthritic Humeral Head.

    abstract::Continuum-level finite element models (FEMs) of the humerus offer the ability to evaluate joint replacement designs preclinically; however, experimental validation of these models is critical to ensure accuracy. The objective of the current study was to quantify experimental full-field strain magnitudes within osteoar...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02549-2

    authors: Kusins J,Knowles N,Columbus M,Oliviero S,Dall'Ara E,Athwal GS,Ferreira LM

    更新日期:2020-12-01 00:00:00

  • Hierarchical CT to Ultrasound Registration of the Lumbar Spine: A Comparison with Other Registration Methods.

    abstract::Three-dimensional (3D) measurement of the spine can provide important information for functional, developmental, diagnostic, and treatment-effect evaluations. However, existing measurement techniques are either 2-dimensional, highly invasive, or involve a high radiation dose, prohibiting their widespread and repeated ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-016-1599-1

    authors: Koo TK,Kwok WE

    更新日期:2016-10-01 00:00:00