Abstract:
:To meet demands of vascular reconstruction, there is a need for prosthetic alternatives to natural blood vessels. Here we explored a new conduit fabrication approach. Macroporous, gelatin microcarriers laden with human umbilical vein endothelial cells and aortic smooth muscle cells were dispensed into tubular agarose molds and found to adhere to form living tubular tissues. The ability of cellularized microcarriers to adhere to one another involved cellular and extracellular matrix bridging that included the formation of epithelium-like cell layers lining the lumenal and ablumenal surfaces of the constructs and the deposition of collagen and elastin fibers. The tubular tissues behaved as elastic solids, with a uniaxial mechanical response that is qualitatively similar to that of native vascular tissues and consistent with their elastin and collagen composition. Linearized measures of the mechanical response of the fabricated tubular tissues at both low and high strains were observed to increase with duration of static culture, with no significant loss of stiffness following decellularization. The findings highlight the utility of cellularized macroporous gelatin microcarriers as self-adhering building blocks for the fabrication of living tubular structures.
journal_name
Ann Biomed Engjournal_title
Annals of biomedical engineeringauthors
Twal WO,Klatt SC,Harikrishnan K,Gerges E,Cooley MA,Trusk TC,Zhou B,Gabr MG,Shazly T,Lessner SM,Markwald RR,Argraves WSdoi
10.1007/s10439-013-0883-6subject
Has Abstractpub_date
2014-07-01 00:00:00pages
1470-81issue
7eissn
0090-6964issn
1573-9686journal_volume
42pub_type
杂志文章abstract::We hypothesize that variations of body anthropometry, conjointly with the bone strength, determine the risk of hip fracture. To test the hypothesis, we compared, in a simulated sideways fall, the hip impact energy to the energy needed to fracture the femur. Ten femurs from elderly donors were tested using a novel drop...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-020-02682-y
更新日期:2020-11-12 00:00:00
abstract::We compare the influence of time-frequency methods on analysis of time-varying renal autoregulation properties. Particularly, we examine if detection probabilities are similar for amplitude and frequency modulation for a modulated simulation signal among five time-frequency approaches, and if time-varying changes in s...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-012-0625-1
更新日期:2013-01-01 00:00:00
abstract::Wall stress analysis of abdominal aortic aneurysm (AAA) is a promising method of identifying AAAs at high risk of rupture. However, neglecting residual strains (RS) in the load-free configuration of patient-specific finite element analysis models is a sever limitation that strongly affects the computed wall stresses. ...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-013-0749-y
更新日期:2013-07-01 00:00:00
abstract::While bone mineral density has been traditionally used to quantify fracture risk for individuals with spinal cord injuries, recent studies are including engineering measurements such as section modulus and cross sectional moment of inertia. These are almost exclusively calculated by peripheral QCT scanners which, unli...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-017-1796-6
更新日期:2017-05-01 00:00:00
abstract::In an ovine femur model, proliferative woven bone fills critically sized defects enveloped by periosteum within 2 weeks of treatment with the one-stage bone-transport surgery. We hypothesize that mechanical loading modulates this process. Using high-definition optical strain measurements we determined prevailing perio...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-010-0242-9
更新日期:2011-05-01 00:00:00
abstract::Coronary artery bypass graft (CABG) failure has been linked to graft hemodynamics, in particular wall shear stress. This study characterizes the morphology, geometry and wall shear stress patterns in human CABGs. The intimal thickness (IT) in 49 human saphenous vein CABGs was measured by digital light microscopy. The ...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-005-1732-z
更新日期:2005-03-01 00:00:00
abstract::Poor prosthetic fit is often the result of heterotopic ossification (HO), a frequent problem following blast injuries for returning service members. Osseointegration technology offers an advantage for individuals with significant HO and poor socket tolerance by using direct skeletal attachment of a prosthesis to the d...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-010-0050-2
更新日期:2010-09-01 00:00:00
abstract::Traditionally, measurement of pulmonary O2 uptake uses mass balance of N2 to correct for differences between inspired and expired volume (V) due to temperature (T) and relative humidity (RH). Often during anesthesia, N2 balance cannot be invoked due to high inspired O2 fraction (FIO2) or nonsteady state conditions. Th...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1114/1.1312184
更新日期:2000-09-01 00:00:00
abstract::Lung cancer patients often suffer from severe airway stenosis, the symptoms of which can be relieved by the implantation of stents. Different respiratory stents are commercially available, but the impact of their mechanical performance on tissue responses is not well understood. Two novel laser-cut and hand-braided ni...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-019-02278-1
更新日期:2019-08-01 00:00:00
abstract::Cardiac MRI (CMR) techniques offer non-invasive visualizations of cardiac morphology and function. However, imaging can be time-consuming and complex. Seismocardiography (SCG) measures physical vibrations transmitted through the chest from the beating heart and pulsatile blood flow. SCG signals can be acquired quickly...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-020-02491-3
更新日期:2020-06-01 00:00:00
abstract::Defibrillation efficacy testing is a common procedure at defibrillator implantation, with the objective to ensure that each patient receives a system with adequate shock efficacy. In this study, defibrillation shock efficacy as a function of shock energy was modeled by a dose response relationship. The frequency distr...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-009-9890-z
更新日期:2010-04-01 00:00:00
abstract::Magnetic nanoparticle (mNP) based thermal therapies have demonstrated relevance in the clinic, but effective application requires an understanding of both its strengths and limitations. This study explores two critical limitations for clinical use: (1) maximizing localized mNP heating, while avoiding bulk heating due ...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-012-0633-1
更新日期:2013-01-01 00:00:00
abstract::The unique resource constraints, urgency, and virulence of the coronavirus disease 2019 pandemic has sparked immense innovation in the development of barrier devices to protect healthcare providers from infectious airborne particles generated by patients during airway management interventions. Of the existing devices,...
journal_title:Annals of biomedical engineering
pub_type: 社论
doi:10.1007/s10439-020-02599-6
更新日期:2020-10-01 00:00:00
abstract::Maintenance of movement accuracy relies on motor learning, by which prior errors guide future behavior. One aspect of this learning process involves the accurate generation of predictions of movement outcome. These predictions can, for example, drive anticipatory movements during a predictive-saccade task. Predictive ...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-012-0669-2
更新日期:2013-08-01 00:00:00
abstract::We present a method for the localized statistical discrimination of class populations based on the Karhunen-Loève and Fukunaga-Koontz transforms. These transforms provide features that model the variance of a sample distribution. The spatial series of a 196 channel epicardial electrogram recording from an arrythmogeni...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/BF02367084
更新日期:1994-09-01 00:00:00
abstract::Classically, the primary tool for quantifying the dynamics of vergence and other eye movements has been the main sequence. The main sequence is a plot of peak velocity versus response amplitude and is particularly useful for comparing the dynamics of a large number of eye movements over a range of response amplitudes....
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1114/1.162
更新日期:1999-05-01 00:00:00
abstract::Currently, autologous cartilage provides the gold standard for auricular reconstruction. However, synthetic biomaterials offer a number of advantages for ear reconstruction including decreased donor site morbidity and earlier surgery. Critical to implant success is the material's mechanical properties as this affects ...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-016-1688-1
更新日期:2016-12-01 00:00:00
abstract::This paper presents an in vitro temperature mapping study of bovine cardiac tissue during radiofrequency ablation. The objectives were to: (i) develop a technique for measuring the spatial and temporal temperature distribution in the tissue and in the blood during ablation, and (ii) use the temperature measurements to...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1114/1.1310218
更新日期:2000-09-01 00:00:00
abstract::Calcium phosphate ceramics have been widely used for filling bone defects to aid in the regeneration of new bone tissue. Addition of osteogenic cells to porous ceramic scaffolds may accelerate the bone repair process. This study demonstrates the feasibility of culturing marrow stromal cells (MSCs) on porous biphasic c...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-005-5536-y
更新日期:2005-09-01 00:00:00
abstract::We develop a mathematical model of nanoparticles depositing onto and penetrating into a biofilm grown in a parallel-plate flow cell. We carry out deposition experiments in a flow cell to support the modeling. The modeling and the experiments are motivated by the potential use of polymer nanoparticles as part of a trea...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-012-0626-0
更新日期:2013-01-01 00:00:00
abstract::The nose is the front line defender of the respiratory system. Unsteady simulations in three-dimensional models have been developed to study transport patterns in the human nose and its overall air-conditioning capacity. The results suggested that the healthy nose can efficiently provide about 90% of the heat and the ...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-005-2513-4
更新日期:2005-04-01 00:00:00
abstract::A study that customizes the feature generator parameters of an asynchronous Brain Interface (BI) is discussed. The goal is to detect the presence of a certain pattern, in the ongoing EEG, associated with a specific movement and to improve the system's performance. Results of this study show that customization mostly b...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-006-9097-5
更新日期:2006-06-01 00:00:00
abstract::We attempted to estimate in living adherent epithelial alveolar cells, the degree of structural and mechanical heterogeneity by considering two individualized cytoskeleton components, i.e., a submembranous "cortical" cytoskeleton and a "deep" cytoskeleton (CSK). F-actin structure characterizing each CSK component was ...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1114/1.1616932
更新日期:2003-11-01 00:00:00
abstract::The study was to explore the effects of BMP-2 gene modified canine bone marrow stromal cells (bMSCs) mediated by a nonviral PEI derivative (GenEscort™ II) in promoting bone formation in vitro and in vivo. Canine bMSCs were cultured and transfected with plasmids containing bone morphogenetic protein-2 gene (pBMP-2) or ...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-011-0276-7
更新日期:2011-06-01 00:00:00
abstract::A computer-controlled optical electromechanical biaxial test system was employed to study the mechanical response of excised sheets of canine visceral pleura. Three classes of tests were performed: uniform biaxial stretching tests and tests in which the specimen was cyclically stretched along one axis while either the...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/BF02367365
更新日期:1986-01-01 00:00:00
abstract::Recently, we reported that tethering and rolling of neutrophils in shear flow over a substrate of E-selectin signals activation of beta 2-integrins and firm adhesion via an intracellular signaling pathway involving phosphorylation of p38 MAP kinase. In the current study the objective was to examine the molecular mecha...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1114/1.1511240
更新日期:2002-09-01 00:00:00
abstract::In this work, we propose an analog electrical model of the coronary circulation for patients with obstructive disease undergoing revascularization. In this clinical situation, the collateral circulation to the occluded artery is difficult to ascertain via preoperative measurements and well-developed collaterals might ...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-008-9500-5
更新日期:2008-07-01 00:00:00
abstract::Linear autoregressive (AR) model-based heart rate (HR) spectral analysis has been widely used to study HR dynamics. Owing to system and measurement noise, the parameters of an AR model have intrinsic statistical uncertainty. In this study, we evaluate how this AR parameter uncertainty can translate to uncertainty in H...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/BF02368320
更新日期:1995-03-01 00:00:00
abstract::Crowding can substantially affect the transition of a protein between its native (N) and unfolded (U) states via volume exclusion effects. Also, it influences considerably the aggregation (A) of unfolded proteins. To examine the details, we developed an approach for computing the kinetic rates of the process N <--> U ...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-005-5780-8
更新日期:2005-08-01 00:00:00
abstract::Poor vascular homeostasis drives many clinical disorders including diabetes, arthritis, atherosclerosis, and peripheral artery disease. Local tissue ischemia resultant of insufficient blood flow is a potent stimulus for recruitment of endothelial progenitor cells (EPCs). This mobilization and homing is a multi-step pr...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章,评审
doi:10.1007/s10439-015-1400-x
更新日期:2015-10-01 00:00:00