Inverse parameter fitting of biological tissues: a response surface approach.

Abstract:

:In this paper, we present the application of a semi-global inverse method for determining material parameters of biological tissues. The approach is based on the successive response surface method, and is illustrated by fitting constitutive parameters to two nonlinear anisotropic constitutive equations, one for aortic sinus and aortic wall, the other for aortic valve tissue. Material test data for the aortic sinus consisted of two independent orthogonal uniaxial tests. Material test data for the aortic valve was obtained from a dynamic inflation test. In each case, a numerical simulation of the experiment was performed and predictions were compared to the real data. For the uniaxial test simulation, the experimental targets were force at a measured displacement. For the inflation test, the experimental targets were the three-dimensional coordinates of material markers at a given pressure. For both sets of tissues, predictions with converged parameters showed excellent agreement with the data, and we found that the method was able to consistently identify model parameters. We believe the method will find wide application in biomedical material characterization and in diagnostic imaging.

journal_name

Ann Biomed Eng

authors

Einstein DR,Freed AD,Stander N,Fata B,Vesely I

doi

10.1007/s10439-005-8338-3

subject

Has Abstract

pub_date

2005-12-01 00:00:00

pages

1819-30

issue

12

eissn

0090-6964

issn

1573-9686

journal_volume

33

pub_type

杂志文章
  • Developing a quantitative measurement system for assessing heterotopic ossification and monitoring the bioelectric metrics from electrically induced osseointegration in the residual limb of service members.

    abstract::Poor prosthetic fit is often the result of heterotopic ossification (HO), a frequent problem following blast injuries for returning service members. Osseointegration technology offers an advantage for individuals with significant HO and poor socket tolerance by using direct skeletal attachment of a prosthesis to the d...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-0050-2

    authors: Isaacson BM,Stinstra JG,MacLeod RS,Pasquina PF,Bloebaum RD

    更新日期:2010-09-01 00:00:00

  • Mathematical simulation of slowing of cardiac conduction velocity by elevated extracellular.

    abstract::We have studied the dependence of conduction velocity (theta) on extracellular potassium concentration ([K+]o) in a model of one-dimensional conduction using an idealized strand of human atrial cells. Elevated [K+]o in the 5-20 mM range shifts the resting potential (Vrest) in the depolarizing direction and reduces inp...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1308489

    authors: Nygren A,Giles WR

    更新日期:2000-08-01 00:00:00

  • Multifunctional FePt nanoparticles for radiation-guided targeting and imaging of cancer.

    abstract::A multifunctional FePt nanoparticle was developed that targets tumor microvasculature via "radiation-guided" peptides, and is detected by both near-infrared (NIR) fluorescence imaging and analytical mass spectrometry methods. Tumor specific binding was first measured by biotinylated peptide linked to fluorophore-conju...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-0219-8

    authors: Hariri G,Wellons MS,Morris WH 3rd,Lukehart CM,Hallahan DE

    更新日期:2011-03-01 00:00:00

  • A numerical implementation to predict residual strains from the homogeneous stress hypothesis with application to abdominal aortic aneurysms.

    abstract::Wall stress analysis of abdominal aortic aneurysm (AAA) is a promising method of identifying AAAs at high risk of rupture. However, neglecting residual strains (RS) in the load-free configuration of patient-specific finite element analysis models is a sever limitation that strongly affects the computed wall stresses. ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-013-0749-y

    authors: Polzer S,Bursa J,Gasser TC,Staffa R,Vlachovsky R

    更新日期:2013-07-01 00:00:00

  • Myofiber ellipticity as an explanation for transverse asymmetry of skeletal muscle diffusion MRI in vivo signal.

    abstract::Due to its unique non-invasive microstructure probing capabilities, diffusion tensor imaging (DTI) constitutes a valuable tool in the study of fiber orientation in skeletal muscles. By implementing a DTI sequence with judiciously chosen directional encoding to quantify in vivo the microarchitectural properties in the ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-009-9783-1

    authors: Karampinos DC,King KF,Sutton BP,Georgiadis JG

    更新日期:2009-12-01 00:00:00

  • Myofilament kinetics in isometric twitch dynamics.

    abstract::To better understand the relationship between kinetic processes of contraction and the dynamic features of an isometric twitch, studies were conducted using a mathematical model that included: (1) kinetics of cross bridge (XB) cycling; (2) kinetics of thin filament regulatory processes; (3) serial and feedback interac...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1366669

    authors: Campbell KB,Razumova MV,Kirkpatrick RD,Slinker BK

    更新日期:2001-05-01 00:00:00

  • Information systems approach to integrated responses in the respiratory control system.

    abstract::The appropriateness of integrated information systems to the description of integrated biological systems is discussed. An integrated information system in the physiology of the regulation of respiration is argued to be a structural mathematical model of the system and the relational data base, which it can compute. I...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02363292

    authors: Yamamoto WS

    更新日期:1983-01-01 00:00:00

  • Automatic Detection of Contracting Muscle Regions via the Deformation Field of Transverse Ultrasound Images: A Feasibility Study.

    abstract::Accurate identification of contracting muscles can help us to understand the muscle function in both physiological and pathological conditions. Conventional electromyography (EMG) have limited access to deep muscles, crosstalk, or instability in the recordings. Accordingly, a novel framework was developed to detect co...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02557-2

    authors: Zheng Y,Shin H,Kamper DG,Hu X

    更新日期:2021-01-01 00:00:00

  • Utilizing Atlas-Based Modeling to Predict Knee Joint Cartilage Degeneration: Data from the Osteoarthritis Initiative.

    abstract::Currently, there are no clinically available tools or applications which could predict osteoarthritis development. Some computational models have been presented to simulate cartilage degeneration, but they are not clinically feasible due to time required to build subject-specific knee models. Therefore, the objective ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-018-02184-y

    authors: Mononen ME,Liukkonen MK,Korhonen RK

    更新日期:2019-03-01 00:00:00

  • High-resolution measurement of the unsteady velocity field to evaluate blood damage induced by a mechanical heart valve.

    abstract::We investigate the potential of prosthetic heart valves to generate abnormal flow and stress patterns, which can contribute to platelet activation and lysis according to blood damage accumulation mechanisms. High-resolution velocity measurements of the unsteady flow field, obtained with a standard particle image veloc...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-011-0329-y

    authors: Bellofiore A,Quinlan NJ

    更新日期:2011-09-01 00:00:00

  • Parameter estimation for linear compartmental models--a sensitivity analysis approach.

    abstract::Linear compartmental models are useful, explanatory tools, that have been widely used to represent the dynamic behavior of complex biological systems. This paper addresses the problem of the numerical identification of such models, i.e., the estimation of the parameter values that will generate predictions closest to ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-009-9651-z

    authors: Juillet B,Bos C,Gaudichon C,Tomé D,Fouillet H

    更新日期:2009-05-01 00:00:00

  • A device for imposing cyclic strain to cells growing on implant alloys.

    abstract::The objective of this study was to develop a unique device for applying well-characterized cyclic, strain to cells growing on implant alloys. The device is based on the four-point bending principle and utilizes an electric motor, belt, and cam system to cyclically deflect a commercially pure titanium plate with cell c...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1529195

    authors: Winter LC,Gilbert JA,Elder SH,Bumgardner JD

    更新日期:2002-11-01 00:00:00

  • Predicting the responses of mechanoreceptor neurons to physiological inputs by nonlinear system identification.

    abstract::The nonlinear dynamic properties of action potential encoding were studied in mechanosensory neurons innervating the slits of a slit-sense organ in the tropical wandering spider, Cupiennius salei. The organ contains two types of neurons that are morphologically similar but have different dynamic properties. Type A neu...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1355278

    authors: French AS,Sekizawa SI,Höger U,Torkkeli PH

    更新日期:2001-03-01 00:00:00

  • An Integrated In Vitro-In Silico Approach for Silver Nanoparticle Dosimetry in Cell Cultures.

    abstract::Potential human and environmental hazards resulting from the exposure of living organisms to silver nanoparticles (Ag NPs) have been the subject of intensive discussion in the last decade. Despite the growing use of Ag NPs in biomedical applications, a quantification of the toxic effects as a function of the total sil...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02449-5

    authors: Poli D,Mattei G,Ucciferri N,Ahluwalia A

    更新日期:2020-04-01 00:00:00

  • Development of FRET assay into quantitative and high-throughput screening technology platforms for protein-protein interactions.

    abstract::Förster resonance energy transfer (FRET) technology has been widely used in biological and biomedical research and is a very powerful tool in elucidating protein interactions in many cellular processes. Ubiquitination and SUMOylation are multi-step cascade reactions, involving multiple enzymes and protein-protein inte...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-0225-x

    authors: Song Y,Madahar V,Liao J

    更新日期:2011-04-01 00:00:00

  • The effect of ultrasonic frequency upon enhanced killing of P. aeruginosa biofilms.

    abstract::It is widely recognized that the bacteria sequestered in a biofilm on a medical implant are much more resistant to antibiotics than their planktonic counterparts. Recent studies have shown that application of antibiotic along with low power ultrasound significantly increases the killing of planktonic bacteria by the a...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02738539

    authors: Qian Z,Sagers RD,Pitt WG

    更新日期:1997-01-01 00:00:00

  • Do Head Injury Biomechanics Predict Concussion Clinical Recovery in College American Football Players?

    abstract::Identifying the associations between head impact biomechanics and clinical recovery may inform better head impact monitoring procedures and identify athletes who may benefit from early treatments aimed to enhance recovery. The purpose of this study was to test whether head injury biomechanics are associated with clini...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02658-y

    authors: Mihalik JP,Chandran A,Powell JR,Roby PR,Guskiewicz KM,Stemper BD,Shah AS,Rowson S,Duma S,Harezlak J,Riggen L,Broglio SP,McAllister TW,McCrea M,CARE Consortium Investigators.

    更新日期:2020-11-01 00:00:00

  • Optimizing magnetic nanoparticle based thermal therapies within the physical limits of heating.

    abstract::Magnetic nanoparticle (mNP) based thermal therapies have demonstrated relevance in the clinic, but effective application requires an understanding of both its strengths and limitations. This study explores two critical limitations for clinical use: (1) maximizing localized mNP heating, while avoiding bulk heating due ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-012-0633-1

    authors: Etheridge ML,Bischof JC

    更新日期:2013-01-01 00:00:00

  • Optical vibrocardiography: a novel tool for the optical monitoring of cardiac activity.

    abstract::We present an optical non-contact method for heart beat monitoring, based on the measurement of chest wall movements induced by the pumping action of the heart, which is eligible as a surrogate of electrocardiogram (ECG) in assessing both cardiac rate and heart rate variability (HRV). The method is based on the optica...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-006-9202-9

    authors: Morbiducci U,Scalise L,De Melis M,Grigioni M

    更新日期:2007-01-01 00:00:00

  • Dual energy CT scanning for analysis of brain damage due to X-irradiation.

    abstract::Therapeutic irradiation is commonly used in the treatment of malignant brain tumors and has the potential to cause severe injury to normal tissues adjacent to a lesion. Computed tomography (CT) can be used not only to visualize tissue damage but to monitor the development of a lesion using advanced quantitative CT tec...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02410288

    authors: Russell LB,Fike JR,Cann CE,Süsskind C

    更新日期:1984-01-01 00:00:00

  • A review of approaches to mobility telemonitoring of the elderly in their living environment.

    abstract::Rapid technological advances have prompted the development of a wide range of telemonitoring systems to enable the prevention, early diagnosis and management, of chronic conditions. Remote monitoring can reduce the amount of recurring admissions to hospital, facilitate more efficient clinical visits with objective res...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/s10439-005-9068-2

    authors: Ní Scanaill C,Carew S,Barralon P,Noury N,Lyons D,Lyons GM

    更新日期:2006-04-01 00:00:00

  • The effect of head rotation on the geometry and hemodynamics of healthy vertebral arteries.

    abstract::The geometric and hemodynamic characteristics of the left and right vertebral arteries (LVA, RVA) of six healthy volunteers were investigated for the supine (S) and the prone position (P) a common sleeping posture with head rotation. MRI images were used to reconstruct the subject specific three-dimensional solid mode...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1340-5

    authors: Aristokleous N,Seimenis I,Georgiou GC,Nicolaides A,Anayiotos AS

    更新日期:2015-06-01 00:00:00

  • Nonlinear dynamics of microvascular blood flow.

    abstract::Kiani et al. (Kiani, M. F., A. R. Pries, L. L. Hsu, I. H. Sarelius, and G. R. Cokelet, Am. J. Physics. 266: H1822-H1828, 1994) suggested that blood velocity, hematocrit, and nodal pressures can oscillate spontaneously in large microvascular networks in the absence of biological control. This paper presents a model of ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1306346

    authors: Carr RT,Lacoin M

    更新日期:2000-06-01 00:00:00

  • Effect of extracellular potassium accumulation on muscle fiber conduction velocity: a simulation study.

    abstract::A progressive reduction in muscle fiber conduction velocity is typically observed during fatiguing muscle contraction. Although the exact causes of the conduction velocity decrease have not yet been fully established, increasing evidence suggests that changes in extracellular potassium concentration may be largely res...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-009-9756-4

    authors: Fortune E,Lowery MM

    更新日期:2009-10-01 00:00:00

  • A small angle light scattering device for planar connective tissue microstructural analysis.

    abstract::The planar fibrous connective tissues of the body are composed of a dense extracellular network of collagen and elastin fibers embedded in a ground matrix, and thus can be thought of as biocomposites. Thus, the quantification of fiber architecture is an important step in developing an understanding of the mechanics of...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02684845

    authors: Sacks MS,Smith DB,Hiester ED

    更新日期:1997-07-01 00:00:00

  • Osteoarthritis: Pathology, Mouse Models, and Nanoparticle Injectable Systems for Targeted Treatment.

    abstract::Osteoarthritis (OA) is a progressive, degenerative disease of articulating joints that not only affects the elderly, but also involves younger, more active individuals with prolonged participation in high physical-demand activities. Thus, effective therapies that are easy to adopt clinically are critical in limiting t...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/s10439-016-1600-z

    authors: Holyoak DT,Tian YF,van der Meulen MC,Singh A

    更新日期:2016-06-01 00:00:00

  • Effects of chamber shape and fiber orientation on relations between fiber dynamics and chamber dynamics.

    abstract::The function of a chamber depends on its hydrodynamic properties: isometric pressures it can exert in the operating range of distensions, compliances in the operating range of distensions, and wall-displacement resistances in the operating range of distensions. Wall-displacement resistance is the departure of pressure...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02368017

    authors: Regen DM

    更新日期:1988-01-01 00:00:00

  • Human saphenous vein coronary artery bypass graft morphology, geometry and hemodynamics.

    abstract::Coronary artery bypass graft (CABG) failure has been linked to graft hemodynamics, in particular wall shear stress. This study characterizes the morphology, geometry and wall shear stress patterns in human CABGs. The intimal thickness (IT) in 49 human saphenous vein CABGs was measured by digital light microscopy. The ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-005-1732-z

    authors: Leask RL,Butany J,Johnston KW,Ethier CR,Ojha M

    更新日期:2005-03-01 00:00:00

  • Bymixer provides on-line calibration of measurement of CO2 volume exhaled per breath.

    abstract::The measurement of CO2 volume exhaled per breath (VCO2.br) can be determined during anesthesia by the multiplication and integration of tidal flow (V) and PCO2. During side-stream capnometry, PCO2 must be advanced in time by transport delay (TD), the time to suction gas through the sampling tube. During ventilation, T...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02738547

    authors: Breen PH,Serina ER

    更新日期:1997-01-01 00:00:00

  • Microfluidics for mammalian cell chemotaxis.

    abstract::The emerging field of micro-technology has opened up new possibilities for exploring cellular chemotaxis in real space and time, and at single cell resolution. Chemotactic cells sense and move in response to chemical gradients and play important roles in a number of physiological and pathological processes, including ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/s10439-011-0489-9

    authors: Kim BJ,Wu M

    更新日期:2012-06-01 00:00:00