Osteoarthritis: Pathology, Mouse Models, and Nanoparticle Injectable Systems for Targeted Treatment.

Abstract:

:Osteoarthritis (OA) is a progressive, degenerative disease of articulating joints that not only affects the elderly, but also involves younger, more active individuals with prolonged participation in high physical-demand activities. Thus, effective therapies that are easy to adopt clinically are critical in limiting the societal burden associated with OA. This review is focused on intra-articular injectable regimens and provides a comprehensive look at existing in vivo models of OA that might be suitable for developing, testing, and finding a cure for OA by intra-articular injections. We first discuss the pathology, molecular mechanisms responsible for the initiation and progression of OA, and challenges associated with disease-specific targeting of OA. We proceed to discuss available animal models of OA and provide a detailed perspective on the use of mouse models in studies of experimental OA. We finally provide a closer look at intra-articular injectable treatments for OA, focusing on biomaterials-based nanoparticles, and provide a comprehensive overview of the various nanometer-size ranges studied.

journal_name

Ann Biomed Eng

authors

Holyoak DT,Tian YF,van der Meulen MC,Singh A

doi

10.1007/s10439-016-1600-z

subject

Has Abstract

pub_date

2016-06-01 00:00:00

pages

2062-75

issue

6

eissn

0090-6964

issn

1573-9686

pii

10.1007/s10439-016-1600-z

journal_volume

44

pub_type

杂志文章,评审
  • Models of flow-induced loading on blood cells in laminar and turbulent flow, with application to cardiovascular device flow.

    abstract::Viscous shear stress and Reynolds stress are often used to predict hemolysis and thrombosis due to flow-induced stress on blood elements in cardiovascular devices. These macroscopic stresses are distinct from the true stress on an individual cell, which is determined by the local microscale flow field. In this paper t...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-007-9308-8

    authors: Quinlan NJ,Dooley PN

    更新日期:2007-08-01 00:00:00

  • Superparamagnetic iron oxide is suitable to label tendon stem cells and track them in vivo with MR imaging.

    abstract::Tendon stem cells (TSCs) may be used to effectively repair or regenerate injured tendons. However, the fates of TSCs once implanted in vivo remain unclear. This study was aimed to determine the feasibility of labeling TSCs with super-paramagnetic iron oxide (SPIO) nano-particles to track TSCs in vivo using MRI. Rabbit...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-013-0802-x

    authors: Yang Y,Zhang J,Qian Y,Dong S,Huang H,Boada FE,Fu FH,Wang JH

    更新日期:2013-10-01 00:00:00

  • Modeling the instantaneous pressure-volume relation of the left ventricle: a comparison of six models.

    abstract::Simulations are useful to study the heart's ability to generate flow and the interaction between contractility and loading conditions. The left ventricular pressure-volume (PV) relation has been shown to be nonlinear, but it is unknown whether a linear model is accurate enough for simulations. Six models were fitted t...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-009-9742-x

    authors: Lankhaar JW,Rövekamp FA,Steendijk P,Faes TJ,Westerhof BE,Kind T,Vonk-Noordegraaf A,Westerhof N

    更新日期:2009-09-01 00:00:00

  • Arterial wave propagation phenomena, ventricular work, and power dissipation.

    abstract::The effects of wave propagation phenomena, namely global reflection coefficient (gamma G[omega]) and pulse wave velocity (Cph), are studied in a model of the coupled left ventricle/arterial system. The left ventricle consists of a time-varying elastance, while the arterial system is modeled as a single, uniform, elast...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02584479

    authors: Berger DS,Li JK,Noordergraaf A

    更新日期:1995-11-01 00:00:00

  • Analog electrical model of the coronary circulation in case of multiple revascularizations.

    abstract::In this work, we propose an analog electrical model of the coronary circulation for patients with obstructive disease undergoing revascularization. In this clinical situation, the collateral circulation to the occluded artery is difficult to ascertain via preoperative measurements and well-developed collaterals might ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-008-9500-5

    authors: Maasrani M,Verhoye JP,Corbineau H,Drochon A

    更新日期:2008-07-01 00:00:00

  • Modeling Human Volunteers in Multidirectional, Uni-axial Sled Tests Using a Finite Element Human Body Model.

    abstract::A goal of the Human Research Program at National Aeronautics and Space Administration (NASA) is to analyze and mitigate the risk of occupant injury due to dynamic loads. Experimental tests of human subjects and biofidelic anthropomorphic test devices provide valuable kinematic and kinetic data related to injury risk e...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-018-02147-3

    authors: Gaewsky JP,Jones DA,Ye X,Koya B,McNamara KP,Gayzik FS,Weaver AA,Putnam JB,Somers JT,Stitzel JD

    更新日期:2019-02-01 00:00:00

  • Nonlinear dynamics of microvascular blood flow.

    abstract::Kiani et al. (Kiani, M. F., A. R. Pries, L. L. Hsu, I. H. Sarelius, and G. R. Cokelet, Am. J. Physics. 266: H1822-H1828, 1994) suggested that blood velocity, hematocrit, and nodal pressures can oscillate spontaneously in large microvascular networks in the absence of biological control. This paper presents a model of ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1306346

    authors: Carr RT,Lacoin M

    更新日期:2000-06-01 00:00:00

  • Effects of training on human tracking of electrocutaneous signals.

    abstract::The effects of training on a person's ability to perceive, interpret and utilize information presented via the tactile sense were examined by using a dual-channel electrocutaneous tracking approach. The electrocutaneous code studied was linear pulse rate encoding of information. The stimulus had a pulse width of 200 m...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02367409

    authors: Szeto AY,Chung YM

    更新日期:1986-01-01 00:00:00

  • Development of a device for measuring adherence of skin grafts to the wound surface.

    abstract::Adherence of a biological graft to the wound surface is the most important factor influencing the ultimate success of graft viability. A machine has been developed to test the adherence of biological graft materials to a substrate such as a wound surface. The peeling mode, which yields reproducible quantitative measur...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02368164

    authors: Dong C,Mead E,Skalak R,Fung YC,Debes JC,Zapata-Sirvent RL,Andree C,Greenleaf G,Cooper M,Hansbrough JF

    更新日期:1993-01-01 00:00:00

  • Fetal Transcatheter Trileaflet Heart Valve Hemodynamics: Implications of Scaling on Valve Mechanics and Turbulence.

    abstract::The scarcity of data available on the best approach for pulmonary fetal valve replacement or implantation necessitate an investigation on whether practices using adult transcatheter valves could be translated to fetal applications. The objective of this study is to evaluate the hemodynamic characteristics and the turb...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02475-3

    authors: Hatoum H,Gooden S,Heitkemper M,Blum KM,Zakko J,Bocks M,Yi T,Wu YL,Wang Y,Breuer CK,Dasi LP

    更新日期:2020-06-01 00:00:00

  • Osteochondral interface tissue engineering using macroscopic gradients of bioactive signals.

    abstract::Continuous gradients exist at osteochondral interfaces, which may be engineered by applying spatially patterned gradients of biological cues. In the present study, a protein-loaded microsphere-based scaffold fabrication strategy was applied to achieve spatially and temporally controlled delivery of bioactive signals i...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-0028-0

    authors: Dormer NH,Singh M,Wang L,Berkland CJ,Detamore MS

    更新日期:2010-06-01 00:00:00

  • Muscle-tendon model with length history-dependent activation-velocity coupling.

    abstract::We developed muscle-tendon models incorporating Hill-type structure and length-dependent coupling between activation and velocity. The models were evaluated in electrically stimulated cat soleus muscles. Dynamic model parameters were estimated by a nonlinear parameter estimation algorithm from input-output data obtain...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.93

    authors: Shue GH,Crago PE

    更新日期:1998-05-01 00:00:00

  • In situ Microrheological Determination of Neutrophil Stiffening Following Adhesion in a Model Capillary.

    abstract::There has been considerable debate on the relative importance of biochemical stimuli and mechanical deformation in neutrophil adhesion in lung capillaries, a process observed following bacterial infection in the body. In contrast to venules, where the vessel diameter is larger than the leukocyte diameter (6-9 microm) ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-008-9437-8

    authors: Pai A,Sundd P,Tees DF

    更新日期:2008-04-01 00:00:00

  • In vitro characterization of a compliant biodegradable scaffold with a novel bioreactor system.

    abstract::The influence of scaffold compliance on blood vessel tissue engineering remains unclear and compliance mismatch issues are important to an in vivo tissue-engineering approach. We have designed and constructed a modular bioreactor system that is capable of imparting pulsatile fluid flow while simultaneously measuring v...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-007-9304-z

    authors: Webb AR,Macrie BD,Ray AS,Russo JE,Siegel AM,Glucksberg MR,Ameer GA

    更新日期:2007-08-01 00:00:00

  • The Role of Synthetic Extracellular Matrices in Endothelial Progenitor Cell Homing for Treatment of Vascular Disease.

    abstract::Poor vascular homeostasis drives many clinical disorders including diabetes, arthritis, atherosclerosis, and peripheral artery disease. Local tissue ischemia resultant of insufficient blood flow is a potent stimulus for recruitment of endothelial progenitor cells (EPCs). This mobilization and homing is a multi-step pr...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/s10439-015-1400-x

    authors: Williams PA,Silva EA

    更新日期:2015-10-01 00:00:00

  • Investigating the relationship between fetus EEG, respiratory, and blood pressure signals during maturation using wavelet transform.

    abstract::In this study, we introduce the fast wavelet transform as a method for characterizing maturational changes in electrocortical activity, respiratory activity, and blood pressure in fetal lambs in early (110-122 days), mid (123-135 days), and late (136-144 days) third trimester (term 145 days). Each recording was 2 hr i...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02584457

    authors: Akay M,Szeto HH

    更新日期:1995-09-01 00:00:00

  • Developing a quantitative measurement system for assessing heterotopic ossification and monitoring the bioelectric metrics from electrically induced osseointegration in the residual limb of service members.

    abstract::Poor prosthetic fit is often the result of heterotopic ossification (HO), a frequent problem following blast injuries for returning service members. Osseointegration technology offers an advantage for individuals with significant HO and poor socket tolerance by using direct skeletal attachment of a prosthesis to the d...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-0050-2

    authors: Isaacson BM,Stinstra JG,MacLeod RS,Pasquina PF,Bloebaum RD

    更新日期:2010-09-01 00:00:00

  • Population-Based Bone Strain During Physical Activity: A Novel Method Demonstrated for the Human Femur.

    abstract::Statistical methods are increasingly used in biomechanics for studying bone geometry, bone density distribution and function in the population. However, relating population-based bone variation to strain during activity is computationally challenging. Here, we describe a new method for calculating strain in a populati...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02483-3

    authors: Ziaeipoor H,Taylor M,Martelli S

    更新日期:2020-06-01 00:00:00

  • Velocity measurements within confined turbulent jets: application to cardiovalvular regurgitation.

    abstract::An expression for centerline mean velocity distributions for circular and noncircular confined turbulent jets has been obtained by assuming self-preservation of flow downstream of the jet potential core. It was assumed that the velocity decay was not only dependent on the streamwise distance x in terms of x/d, as in t...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:

    authors: Liu H,Winoto SH,Shah DA

    更新日期:1997-11-01 00:00:00

  • Computational study of fluid mechanical disturbance induced by endovascular stents.

    abstract::Arterial restenosis following stent deployment may be influenced by the local flow environment within and around the stent. We have used computational fluid dynamics to investigate the flow field in the vicinity of model stents positioned within straight and curved vessels. Our simulations have revealed the presence o...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-005-2499-y

    authors: Seo T,Schachter LG,Barakat AI

    更新日期:2005-04-01 00:00:00

  • Computational study of proteolysis-driven single cell migration in a three-dimensional matrix.

    abstract::Cell migration is a fundamental process that is crucial to a variety of physiological events. While traditional approaches have focused on two-dimensional (2D) systems, recent efforts have shifted to studying migration in three-dimensional (3D) matrices. A major distinction that has emerged is the increased importance...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-9970-0

    authors: Harjanto D,Zaman MH

    更新日期:2010-05-01 00:00:00

  • Integration of clinical data collected at different times for virtual surgery in single ventricle patients: a case study.

    abstract::Newborns with single ventricle physiology are usually palliated with a multi-staged procedure. When cardiovascular complications e.g., collateral vessel formation occur during the inter-stage periods, further treatments are required. An 8-month-old patient, who underwent second stage (i.e., bi-directional Glenn, BDG) ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-014-1113-6

    authors: Corsini C,Baker C,Baretta A,Biglino G,Hlavacek AM,Hsia TY,Kung E,Marsden A,Migliavacca F,Vignon-Clementel I,Pennati G,Modeling of Congenital Hearts Alliance (MOCHA) Investigators.

    更新日期:2015-06-01 00:00:00

  • Error mechanisms of the oscillometric fixed-ratio blood pressure measurement method.

    abstract::The oscillometric fixed-ratio method is widely employed for non-invasive measurement of systolic and diastolic pressures (SP and DP) but is heuristic and prone to error. We investigated the accuracy of this method using an established mathematical model of oscillometry. First, to determine which factors materially aff...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-012-0700-7

    authors: Liu J,Hahn JO,Mukkamala R

    更新日期:2013-03-01 00:00:00

  • Countercurrent extraction of sparingly soluble gases for membrane introduction mass spectrometry.

    abstract::Membrane introduction mass spectrometry has been applied to inert gas measurements in blood and tissue, but gases with low blood solubility are associated with reduced sensitivity. Countercurrent extraction of inert gases from a blood sample into a water carrier phase has the potential to extract most of the gas sampl...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02684170

    authors: Baumgardner JE,Neufeld GR

    更新日期:1997-09-01 00:00:00

  • A device for imposing cyclic strain to cells growing on implant alloys.

    abstract::The objective of this study was to develop a unique device for applying well-characterized cyclic, strain to cells growing on implant alloys. The device is based on the four-point bending principle and utilizes an electric motor, belt, and cam system to cyclically deflect a commercially pure titanium plate with cell c...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1529195

    authors: Winter LC,Gilbert JA,Elder SH,Bumgardner JD

    更新日期:2002-11-01 00:00:00

  • Automatic Model Generation Framework for Computational Simulation of Cochlear Implantation.

    abstract::Recent developments in computational modeling of cochlear implantation are promising to study in silico the performance of the implant before surgery. However, creating a complete computational model of the patient's anatomy while including an external device geometry remains challenging. To address such a challenge, ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1541-y

    authors: Mangado N,Ceresa M,Duchateau N,Kjer HM,Vera S,Dejea Velardo H,Mistrik P,Paulsen RR,Fagertun J,Noailly J,Piella G,González Ballester MÁ

    更新日期:2016-08-01 00:00:00

  • Nonequilibrium facilitated transport of carbon dioxide in bicarbonate and bovine albumin solutions.

    abstract::The nonlinear diffusion-reaction equations describing the nonequilibrium transport of CO2 through flat layers of complex but homogeneous aqueous media were solved by an approximate analytical method called the "Combined Damköhler Number" (CDN) technique. Unlike other approximate analytical solutions, the CDN technique...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02484468

    authors: Hoofd LJ,Tong RR,Stroeve P

    更新日期:1986-01-01 00:00:00

  • Electrically active bioceramics: a review of interfacial responses.

    abstract::Electrical potentials in mechanically loaded bone have been implicated as signals in the bone remodeling cycle. Recently, interest has grown in exploiting this phenomenon to develop electrically active ceramics for implantation in hard tissue which may induce improved biological responses. Both polarized hydroxyapatit...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/s10439-010-9977-6

    authors: Baxter FR,Bowen CR,Turner IG,Dent AC

    更新日期:2010-06-01 00:00:00

  • Quantification of rigidity in Parkinson's disease.

    abstract::In this paper, a new method for quantification of rigidity in elbow joint of Parkinsonian patients is introduced. One of the most known syndromes in Parkinson's disease (PD) is increased passive stiffness in muscles, which leads to rigidity in joints. Clinical evaluation of stiffness in wrist and/or elbow, commonly us...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-007-9379-6

    authors: Sepehri B,Esteki A,Ebrahimi-Takamjani E,Shahidi GA,Khamseh F,Moinodin M

    更新日期:2007-12-01 00:00:00

  • Emerging Brain Morphologies from Axonal Elongation.

    abstract::Understanding the characteristic morphology of our brain remains a challenging, yet important task in human evolution, developmental biology, and neurosciences. Mathematical modeling shapes our understanding of cortical folding and provides functional relations between cortical wavelength, thickness, and stiffness. Ye...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1312-9

    authors: Holland MA,Miller KE,Kuhl E

    更新日期:2015-07-01 00:00:00