Arterial wave propagation phenomena, ventricular work, and power dissipation.

Abstract:

:The effects of wave propagation phenomena, namely global reflection coefficient (gamma G[omega]) and pulse wave velocity (Cph), are studied in a model of the coupled left ventricle/arterial system. The left ventricle consists of a time-varying elastance, while the arterial system is modeled as a single, uniform, elastic tube terminating in a complex load. Manipulation of model parameters allowed for the precise control of gamma G(omega) and Cph independent of each other, peripheral resistance, and characteristic impedance. Reduction of gamma G(omega) and Cph were achieved through increases in load compliance and tube compliance, respectively. The equations describing the system were solved for left ventricular and aortic pressures and aortic flow. From these, stroke volume (SV), left ventricular stroke work (SW), and steady (Ws), oscillatory (Wo), and total power dissipation (Wt) in the arterial system were calculated. An index of arterial system efficiency was the ratio Wo/Wt (%Wo), with lower values indicating higher efficiency. Reduction of gamma G(omega) yielded initial increases in Ws, while Wo increased for the entire range of gamma G(omega), resulting in increased %Wo. This reduced efficiency is imposed on the ventricle, resulting in increased SW without increased SV. On the other hand, decreased Cph yielded in a steady increase in Ws and a biphasic response in Wo, resulting in reduced %Wo for most of the range of reduced Cph. These results suggest that differential effects on arterial system efficiency can result from reductions of gamma G(omega) and Cph. In terms of compliance, changes in arterial compliance can have different effects on efficiency, depending on where the compliance change takes place. Reasons for these results are suggested, and the role of distributed compliances is raised as a new problem.

journal_name

Ann Biomed Eng

authors

Berger DS,Li JK,Noordergraaf A

doi

10.1007/BF02584479

subject

Has Abstract

pub_date

1995-11-01 00:00:00

pages

804-11

issue

6

eissn

0090-6964

issn

1573-9686

journal_volume

23

pub_type

杂志文章
  • Do Head Injury Biomechanics Predict Concussion Clinical Recovery in College American Football Players?

    abstract::Identifying the associations between head impact biomechanics and clinical recovery may inform better head impact monitoring procedures and identify athletes who may benefit from early treatments aimed to enhance recovery. The purpose of this study was to test whether head injury biomechanics are associated with clini...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02658-y

    authors: Mihalik JP,Chandran A,Powell JR,Roby PR,Guskiewicz KM,Stemper BD,Shah AS,Rowson S,Duma S,Harezlak J,Riggen L,Broglio SP,McAllister TW,McCrea M,CARE Consortium Investigators.

    更新日期:2020-11-01 00:00:00

  • Optical Metabolic Imaging for Assessment of Radiation-Induced Injury to Rat Kidney and Mitigation by Lisinopril.

    abstract::The kidney is one of the most radiosensitive organs; it is the primary dose-limiting organ in radiotherapies for upper abdominal cancers. The role of mitochondrial redox state in the development and treatment of renal radiation injury, however, remains ill-defined. This study utilizes 3D optical cryo-imaging to quanti...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-019-02255-8

    authors: Mehrvar S,la Cour MF,Medhora M,Camara AKS,Ranji M

    更新日期:2019-07-01 00:00:00

  • A novel method for visualization of entire coronary arterial tree.

    abstract::The complexity of the coronary circulation especially in the deep layers largely evades experimental investigations. Hence, virtual/computational models depicting structure-function relation of the entire coronary vasculature including the deep layer are imperative. In order to interpret such anatomically based models...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-007-9278-x

    authors: Wischgoll T,Meyer J,Kaimovitz B,Lanir Y,Kassab GS

    更新日期:2007-05-01 00:00:00

  • Parameter estimation for linear compartmental models--a sensitivity analysis approach.

    abstract::Linear compartmental models are useful, explanatory tools, that have been widely used to represent the dynamic behavior of complex biological systems. This paper addresses the problem of the numerical identification of such models, i.e., the estimation of the parameter values that will generate predictions closest to ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-009-9651-z

    authors: Juillet B,Bos C,Gaudichon C,Tomé D,Fouillet H

    更新日期:2009-05-01 00:00:00

  • MEG connectivity analysis in patients with Alzheimer's disease using cross mutual information and spectral coherence.

    abstract::Alzheimer's disease (AD) is an irreversible brain disorder which represents the most common form of dementia in western countries. An early and accurate diagnosis of AD would enable to develop new strategies for managing the disease; however, nowadays there is no single test that can accurately predict the development...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-0155-7

    authors: Alonso JF,Poza J,Mañanas MA,Romero S,Fernández A,Hornero R

    更新日期:2011-01-01 00:00:00

  • The Effects of 4%Fe on the Performance of Pure Zinc as Biodegradable Implant Material.

    abstract::The efforts to develop structural materials for biodegradable metal implants have lately shifted their focus from Magnesium and Iron base alloys towards Zinc. This was mainly due to the accelerated corrosion rate of Mg that is accompanied by hydrogen gas evolution, formation of voluminous iron oxide products with redu...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-019-02245-w

    authors: Kafri A,Ovadia S,Yosafovich-Doitch G,Aghion E

    更新日期:2019-06-01 00:00:00

  • Phonocardiographic signal analysis method using a modified hidden Markov model.

    abstract::Auscultation is an important diagnostic indicator for cardiovascular analysis. Heart sound classification and analysis play an important role in the auscultative diagnosis. This study uses a combination of Mel-frequency cepstral coefficient (MFCC) and hidden Markov model (HMM) to efficiently extract the features for p...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-006-9232-3

    authors: Wang P,Lim CS,Chauhan S,Foo JY,Anantharaman V

    更新日期:2007-03-01 00:00:00

  • Full-Length Recombinant Human Proteoglycan 4 Interacts with Hyaluronan to Provide Cartilage Boundary Lubrication.

    abstract::Proteoglycan 4 (PRG4) is a mucin-like glycoprotein present in synovial fluid and at the surface of articular cartilage. The objectives of this study were to (1) assess the articular cartilage surface adsorption and in vitro cartilage boundary lubricating ability of full-length recombinant human PRG4 (rhPRG4), and (2) ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1390-8

    authors: Abubacker S,Dorosz SG,Ponjevic D,Jay GD,Matyas JR,Schmidt TA

    更新日期:2016-04-01 00:00:00

  • A computerized mass spectrometer and flowmeter system for respiratory gas measurements.

    abstract::Instrumentation systems for breath-to-breath analysis of respiratory gas exchange have been faulted by phase lags between various flow and composition signals and by difficulties in gathering and processing large amounts of data. The system described here represents an attempt to overcome these problems. Phase delays ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02367493

    authors: Sodal IE,Swanson GD,Micco AJ,Sprague F,Ellis DG

    更新日期:1983-01-01 00:00:00

  • Simultaneous regulation of hemodynamic and anesthetic states: a simulation study.

    abstract::A model predictive control strategy to simultaneously regulate hemodynamic and anesthetic variables in critical care patients is presented. A nonlinear canine circulatory model, which has been used to study the effect of inotropic and vasoactive drugs on hemodynamic variables, has been extended to include propofol pha...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.255

    authors: Rao RR,Bequette BW,Roy RJ

    更新日期:2000-01-01 00:00:00

  • In Silico Ventilation Within the Dose-Volume is Predictive of Lung Function Post-radiation Therapy in Patients with Lung Cancer.

    abstract::Lung cancer is a leading cause of death worldwide. Radiation therapy (RT) is one method to treat this disease. A common side effect of RT for lung cancer is radiation-induced lung damage (RILD) which leads to loss of lung function. RILD often compounds pre-existing smoking-related regional lung function impairment. It...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02697-5

    authors: Dong Y,Kumar H,Tawhai M,Veiga C,Szmul A,Landau D,McClelland J,Lao L,Burrowes KS

    更新日期:2020-11-30 00:00:00

  • An artificial neural network approach to the predictive modeling of tensile force during renal suturing.

    abstract::Further understanding of the mechanical deformation and tear behavior of kidney during suturing helps to enhance surgical task execution that requires fine suture manipulation. This paper aims to develop a model to describe the relationship between the tensile force acting on suture line and the resulted kidney deform...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-012-0722-1

    authors: Yu D,Qing Y,Jianxun Z,Jun D

    更新日期:2013-04-01 00:00:00

  • Cue-Signal-Response Analysis in 3D Chondrocyte Scaffolds with Anabolic Stimuli.

    abstract::Articular cartilage is an avascular connective tissue responsible for bearing loads. Cell signaling plays a central role in cartilage homeostasis and tissue engineering by directing chondrocytes to synthesize/degrade the extracellular matrix or promote inflammatory responses. The aim of this paper was to investigate a...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-017-1964-8

    authors: Neidlin M,Korcari A,Macheras G,Alexopoulos LG

    更新日期:2018-02-01 00:00:00

  • Geodesic based registration of sensor data and anatomical surface image data.

    abstract::This paper presents two related methods for registering an image of an anatomical object with data from sensors arranged on the object. One method is described with reference to a test case involving a rectangular electrode plaque disposed on a heart surface, which is imaged with MRI. Data from the electrodes is fused...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-007-9350-6

    authors: Hopenfeld B,Ashikaga H,McVeigh ER

    更新日期:2007-10-01 00:00:00

  • A review of approaches to mobility telemonitoring of the elderly in their living environment.

    abstract::Rapid technological advances have prompted the development of a wide range of telemonitoring systems to enable the prevention, early diagnosis and management, of chronic conditions. Remote monitoring can reduce the amount of recurring admissions to hospital, facilitate more efficient clinical visits with objective res...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/s10439-005-9068-2

    authors: Ní Scanaill C,Carew S,Barralon P,Noury N,Lyons D,Lyons GM

    更新日期:2006-04-01 00:00:00

  • Bymixer provides on-line calibration of measurement of CO2 volume exhaled per breath.

    abstract::The measurement of CO2 volume exhaled per breath (VCO2.br) can be determined during anesthesia by the multiplication and integration of tidal flow (V) and PCO2. During side-stream capnometry, PCO2 must be advanced in time by transport delay (TD), the time to suction gas through the sampling tube. During ventilation, T...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02738547

    authors: Breen PH,Serina ER

    更新日期:1997-01-01 00:00:00

  • Measurement of three-dimensional anisotropic diffusion by multiphoton fluorescence recovery after photobleaching.

    abstract::The multiphoton fluorescence recovery after photobleaching (MP-FRAP) technique has been developed to measure the three-dimensional (3D) solute diffusion within biological systems. However, current 3D MP-FRAP models are based on isotropic diffusion and spatial domain analysis. The 3D anisotropic diffusion and frequency...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-013-0939-7

    authors: Shi C,Cisewski SE,Bell PD,Yao H

    更新日期:2014-03-01 00:00:00

  • A mediated glucose biosensor incorporated with reverse iontophoresis function for noninvasive glucose monitoring.

    abstract::The objective of this study was to develop a ferrocene mediated glucose biosensor for reverse iontophoresis. An amperometric ferrocene mediated glucose biosensor based on a three electrodes planar configuration was constructed using screen printing technique. Different combinations of glucose oxidase and ferrocene loa...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-9918-4

    authors: Ching CT,Sun TP,Huang SH,Shieh HL,Chen CY

    更新日期:2010-04-01 00:00:00

  • Superparamagnetic iron oxide is suitable to label tendon stem cells and track them in vivo with MR imaging.

    abstract::Tendon stem cells (TSCs) may be used to effectively repair or regenerate injured tendons. However, the fates of TSCs once implanted in vivo remain unclear. This study was aimed to determine the feasibility of labeling TSCs with super-paramagnetic iron oxide (SPIO) nano-particles to track TSCs in vivo using MRI. Rabbit...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-013-0802-x

    authors: Yang Y,Zhang J,Qian Y,Dong S,Huang H,Boada FE,Fu FH,Wang JH

    更新日期:2013-10-01 00:00:00

  • A microcomputer oxygen control system for ventilatory therapy.

    abstract::A computer-based feedback system has been developed to adjust the concentration of oxygen in the inspired gas of a patient under artificial respiration. The system uses a proportional plus integral controller and feedback of arterial oxygen saturation to adjust the inspired oxygen fraction. The effectiveness of the co...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02368173

    authors: Tehrani FT

    更新日期:1992-01-01 00:00:00

  • Tensile strain as a regulator of mesenchymal stem cell osteogenesis.

    abstract::A role for mechanical stimulation in the control of cell fate has been proposed and mechanical conditioning of mesenchymal stem cells (MSCs) is of interest in directing MSC behavior for tissue engineering applications. This study investigates strain-induced differentiation and proliferation of MSCs, and investigates t...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-9979-4

    authors: Kearney EM,Farrell E,Prendergast PJ,Campbell VA

    更新日期:2010-05-01 00:00:00

  • Multi-molecular gradients of permissive and inhibitory cues direct neurite outgrowth.

    abstract::Correct development of neuronal tracts requires the coordination of multiple permissive and inhibitory signals. By generating an in vitro microenvironment using soft lithography and microfluidic techniques, multiple guidance cues can be presented in a spatially defined way. Here we evaluated how neurites of dorsal roo...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-008-9486-z

    authors: Li GN,Liu J,Hoffman-Kim D

    更新日期:2008-06-01 00:00:00

  • High-resolution measurement of the unsteady velocity field to evaluate blood damage induced by a mechanical heart valve.

    abstract::We investigate the potential of prosthetic heart valves to generate abnormal flow and stress patterns, which can contribute to platelet activation and lysis according to blood damage accumulation mechanisms. High-resolution velocity measurements of the unsteady flow field, obtained with a standard particle image veloc...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-011-0329-y

    authors: Bellofiore A,Quinlan NJ

    更新日期:2011-09-01 00:00:00

  • Body Anthropometry and Bone Strength Conjointly Determine the Risk of Hip Fracture in a Sideways Fall.

    abstract::We hypothesize that variations of body anthropometry, conjointly with the bone strength, determine the risk of hip fracture. To test the hypothesis, we compared, in a simulated sideways fall, the hip impact energy to the energy needed to fracture the femur. Ten femurs from elderly donors were tested using a novel drop...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02682-y

    authors: Palanca M,Perilli E,Martelli S

    更新日期:2020-11-12 00:00:00

  • A computational study of the effect of false vocal folds on glottal flow and vocal fold vibration during phonation.

    abstract::The false vocal folds are believed to be components of the acoustic filter that is responsible for shaping the voice. However, the effects of false vocal folds on the vocal fold vibration and the glottal aerodynamic during phonation remain unclear. This effect has implications for computational modeling of phonation a...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-008-9630-9

    authors: Zheng X,Bielamowicz S,Luo H,Mittal R

    更新日期:2009-03-01 00:00:00

  • Particle motion within in vitro models of stenosed internal carotid and left anterior descending coronary arteries.

    abstract::Asymmetric 75% and 95% area reduction, transparent Sylgard stenotic models were operated under internal carotid artery (ICA) [Womersley parameter, alpha=5.36, Re(mean) =213 and 180, respectively, and Re(peak)=734 and 410, respectively] and left anterior descending coronary artery (LAD) flow wave forms (alpha=2.65, Re(...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.131

    authors: Cao J,Rittgers SE

    更新日期:1998-03-01 00:00:00

  • Lensfree optofluidic microscopy and tomography.

    abstract::Microfluidic devices aim at miniaturizing, automating, and lowering the cost of chemical and biological sample manipulation and detection, hence creating new opportunities for lab-on-a-chip platforms. Recently, optofluidic devices have also emerged where optics is used to enhance the functionality and the performance ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/s10439-011-0385-3

    authors: Bishara W,Isikman SO,Ozcan A

    更新日期:2012-02-01 00:00:00

  • In vitro temperature map of cardiac ablation demonstrates the effect of flow on lesion development.

    abstract::This paper presents an in vitro temperature mapping study of bovine cardiac tissue during radiofrequency ablation. The objectives were to: (i) develop a technique for measuring the spatial and temporal temperature distribution in the tissue and in the blood during ablation, and (ii) use the temperature measurements to...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1310218

    authors: Jain MK,Wolf PD

    更新日期:2000-09-01 00:00:00

  • Bimodal analysis of mammary epithelial cell migration in two dimensions.

    abstract::Cell migration paths of mammary epithelial cells (expressing different versions of the promigratory tyrosine kinase receptor Her2/Neu) were analyzed within a bimodal framework that is a generalization of the run-and-tumble description applicable to bacterial migration. The mammalian cell trajectories were segregated i...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-008-9592-y

    authors: Potdar AA,Lu J,Jeon J,Weaver AM,Cummings PT

    更新日期:2009-01-01 00:00:00

  • Enhancement of stent-induced thromboembolism by residual stenoses: contribution of hemodynamics.

    abstract::In vitro stent-induced thromboembolism was altered by the presence of residual stenoses placed upstream or placed upstream and downstream of the stent. Heparinized (3 micro/ml) bovine blood was gravity fed through a conduit with a deployed coronary stent. Embolism was continuously monitored using a light-scattering mi...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.243

    authors: Sukavaneshvar S,Rosa GM,Solen KA

    更新日期:2000-02-01 00:00:00