A device for imposing cyclic strain to cells growing on implant alloys.

Abstract:

:The objective of this study was to develop a unique device for applying well-characterized cyclic, strain to cells growing on implant alloys. The device is based on the four-point bending principle and utilizes an electric motor, belt, and cam system to cyclically deflect a commercially pure titanium plate with cell culture wells in the middle of the plate. Analyses demonstrated that 182 +/- 3, 366 +/- 9, and 984 +/- 7 microstrain may be cyclically generated in culture areas from 0.5 to 10 Hz for up to 72 h. UMR-106 osteoblast-like cells growing on the titanium plate were subjected to these strain magnitudes at 1.5 Hz for periods of 4 or 24 h. Cells were checked for viability, total protein as a general indicator of cell number, and alkaline phosphatase activity (ALP) as an indicator of bone cell func-tion. Cells strained at 984 +/- 7 microstrain exhibited 21%-24% more protein but 45%-49% less ALP activity than cells strained at 182 +/- 2 or 366 +/- 9 microstrain. Decreased ALP activity may indicate impaired mineralization. Results indicate the device is suitable for applying known, cyclic strain to cells growing on implant alloys and evaluating cellular responses to strain while growing on implant alloys.

journal_name

Ann Biomed Eng

authors

Winter LC,Gilbert JA,Elder SH,Bumgardner JD

doi

10.1114/1.1529195

subject

Has Abstract

pub_date

2002-11-01 00:00:00

pages

1242-50

issue

10

eissn

0090-6964

issn

1573-9686

journal_volume

30

pub_type

杂志文章
  • Strength and electron features of irradiated bone.

    abstract::Radiation applied for therapy and diagnostics damages molecular/atomic couples of biotissues, bones being among them. As a result, electron peculiarities and mechanical behavior of the latter are altered. Correlation between strength of the irradiated bone and its electron features explored due to photo- and exoelectr...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1114/1.1424911

    authors: Dekhtyar Y

    更新日期:2001-12-01 00:00:00

  • Cerebrovascular transmural pressure and autoregulation.

    abstract::The cerebral blood flow (CBF) response to changes in perfusion pressure mediated through decreases in arterial pressure, increases in cerebrospinal fluid (CSF) pressure and increases in jugular venous pressure was studied in anesthetized dogs. A preparation was developed in which each of the three relevant pressures c...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02584249

    authors: Wagner EM,Traystman RJ

    更新日期:1985-01-01 00:00:00

  • Determination of mechanical properties of spatially heterogeneous breast tissue specimens using contact mode atomic force microscopy (AFM).

    abstract::This paper outlines a comprehensive parametric approach for quantifying mechanical properties of spatially heterogeneous thin biological specimens such as human breast tissue using contact-mode Atomic Force Microscopy. Using inverse finite element (FE) analysis of spherical nanoindentation, the force response from hyp...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-014-1057-x

    authors: Roy R,Desai JP

    更新日期:2014-09-01 00:00:00

  • Flow visualization in mechanical heart valves: occluder rebound and cavitation potential.

    abstract::High density particle image velocimetry, with spatial resolution of O(1 mm), was used to measure the effect of occluder rebound on the flow field near a Bjork-Shiley Monostrut tilting-disk mitral valve. The ability to measure two velocity components over an entire plane simultaneously provides a very different insight...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.281

    authors: Kini V,Bachmann C,Fontaine A,Deutsch S,Tarbell JM

    更新日期:2000-04-01 00:00:00

  • Spectral analysis of Doppler flow velocity signals: assessment of objectives, methods, and interpretation.

    abstract::The objective of this paper is to review the theoretical basis and clinical application of electrical impedance plethysmography in the noninvasive evaluation of peripheral arterial and venous disease. Theoretical, experimental and clinical studies have not demonstrated a direct relationship between electrical impedanc...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02410294

    authors: Zuech PE,Cobbold RS,Johnston KW,Kassam M

    更新日期:1984-01-01 00:00:00

  • Rat aortic smooth muscle cells contract in response to serum and its components in a calcium independent manner.

    abstract::Diluted serum provides a model of interstitial fluid that can be used to study the response of smooth muscle cells (SMCs) to interstitial flow. The effect of serum and some of its components on SMC contraction (area reduction) and intracellular calcium ([Ca2+]i) response were characterized in rat aortic SMC in vitro. ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-004-7820-7

    authors: Ainslie K,Shi ZD,Garanich JS,Tarbell JM

    更新日期:2004-12-01 00:00:00

  • Time-frequency approaches for the detection of interactions and temporal properties in renal autoregulation.

    abstract::We compare the influence of time-frequency methods on analysis of time-varying renal autoregulation properties. Particularly, we examine if detection probabilities are similar for amplitude and frequency modulation for a modulated simulation signal among five time-frequency approaches, and if time-varying changes in s...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-012-0625-1

    authors: Scully CG,Siu KL,Cupples WA,Braam B,Chon KH

    更新日期:2013-01-01 00:00:00

  • A reaction-diffusion model of basic fibroblast growth factor interactions with cell surface receptors.

    abstract::Basic fibroblast growth factor (FGF-2) is a potent angiogenic growth factor involved in the development of diseases such as cancer, atherosclerosis, and heart and limb ischemia, as well as normal wound healing and tissue development. Despite being one of the most heavily studied angiogenic growth factors, the binding ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1023/b:abme.0000030231.88326.78

    authors: Filion RJ,Popel AS

    更新日期:2004-05-01 00:00:00

  • High fidelity virtual stenting (HiFiVS) for intracranial aneurysm flow diversion: in vitro and in silico.

    abstract::A flow diverter (FD) is a flexible, densely braided stent-mesh device placed endoluminally across an intracranial aneurysm to induce its thrombotic occlusion. FD treatment planning using computational virtual stenting and flow simulation requires accurate representation of the expanded FD geometry. We have recently de...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-013-0808-4

    authors: Ma D,Dumont TM,Kosukegawa H,Ohta M,Yang X,Siddiqui AH,Meng H

    更新日期:2013-10-01 00:00:00

  • Direct Observation of Low Strain, High Rate Deformation of Cultured Brain Tissue During Primary Blast.

    abstract::The Veterans Health Administration determined that over 250,000 U.S. service members were diagnosed with a traumatic brain injury (TBI) between 2008 and 2018, of which a great proportion were due to blast exposure. Although the penetrating (secondary) and inertia-driven (tertiary) phases of blast-induced TBI (bTBI) ha...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-019-02437-4

    authors: Vogel EW 3rd,Panzer MB,Morales FN,Varghese N,Bass CR,Meaney DF,Morrison B 3rd

    更新日期:2020-04-01 00:00:00

  • Prediction of the biomechanical effects of compression therapy on deep veins using finite element modelling.

    abstract::Clinicians generally assume that Medical Compression Stockings (MCS) work by reducing vein luminal diameter and, in this way, help to prevent blood pooling. Conflicting results have been reported however in the case of lower leg deep veins which call into question this hypothesis. The purpose of this contribution is t...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-014-1121-6

    authors: Rohan PY,Badel P,Lun B,Rastel D,Avril S

    更新日期:2015-02-01 00:00:00

  • Effects of hydration and fixed charge density on fluid transport in charged hydrated soft tissues.

    abstract::The effects of tissue hydration and fixed charge density on hydraulic permeability and creep behavior of cartilaginous tissues have been investigated using the triphasic theory and finite element methods. The empirical model for hydraulic permeability of uncharged gels and Mackie and Meares (1955) model for ion diffus...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1615576

    authors: Gu WY,Yao H

    更新日期:2003-11-01 00:00:00

  • Sensor Anchoring Improves the Correlation Between Intramuscular Pressure and Muscle Tension in a Rabbit Model.

    abstract::Intramuscular pressure (IMP) shows promise for estimating individual muscle tension in vivo. However, previous pressure measurements show high variability during isometric contraction and poor correlation with tension during dynamic contraction. We hypothesized that enhanced sensor anchoring/orientation would improve ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02633-7

    authors: O'Connor SM,Kaufman KR,Ward SR,Lieber RL

    更新日期:2021-02-01 00:00:00

  • Digital processing of the current noise evoked by kainate in cerebellar granule cells.

    abstract::Current induced in cultured cerebellar granule cells by the bath application of kainate (500 microM) was measured using the conventional patch-clamp technique. Two different kinds of responses were observed after the agonist perfusion. Some cells exhibited small inward whole-cell currents: 116 +/- 40 pA (7 cells) at a...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02684186

    authors: Cavalcanti S,Zona C

    更新日期:1997-05-01 00:00:00

  • Modeling life.

    abstract::We seek to construct physical and mathematical models of life. Such models allow us to test our understanding of how living systems function and how they respond to human imposed stimuli. One system is a genomically and chemically complete model of a minimal cell. This cell is a hypothetical bacterium with the fewest ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/s10439-012-0567-7

    authors: Shuler ML

    更新日期:2012-07-01 00:00:00

  • Assessing the susceptibility to local buckling at the femoral neck cortex to age-related bone loss.

    abstract::Although it is known that long cortical bone structurally alter their area moment of inertia with age related bone loss maintaining their bending strength, the incidence of fragility fractures associated with cortical thinning still prevails. We hypothesize that cortical thinning with aging increases the local bucklin...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-009-9751-9

    authors: Lee T,Choi JB,Schafer BW,Segars WP,Eckstein F,Kuhn V,Beck TJ

    更新日期:2009-09-01 00:00:00

  • Estimating the parameter distributions of defibrillation shock efficacy curves in a large population.

    abstract::Defibrillation efficacy testing is a common procedure at defibrillator implantation, with the objective to ensure that each patient receives a system with adequate shock efficacy. In this study, defibrillation shock efficacy as a function of shock energy was modeled by a dose response relationship. The frequency distr...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-009-9890-z

    authors: Smits K,Virag N

    更新日期:2010-04-01 00:00:00

  • Influence of autoregressive model parameter uncertainty on spectral estimates of heart rate dynamics.

    abstract::Linear autoregressive (AR) model-based heart rate (HR) spectral analysis has been widely used to study HR dynamics. Owing to system and measurement noise, the parameters of an AR model have intrinsic statistical uncertainty. In this study, we evaluate how this AR parameter uncertainty can translate to uncertainty in H...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02368320

    authors: Christini DJ,Kulkarni A,Rao S,Stutman ER,Bennett FM,Hausdorff JM,Oriol N,Lutchen KR

    更新日期:1995-03-01 00:00:00

  • Antithrombotic Protein Filter Composed of Hybrid Tissue-Fabric Material has a Long Lifetime.

    abstract::There are recent reports of hybrid tissue-fabric materials with good performance-high biocompatibility and high mechanical strength. In this study, we demonstrate the capability of a hybrid material as a long-term filter for blood proteins. Polyester fabrics were implanted into rats to fabricate hybrid tissue-fabric m...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-016-1781-5

    authors: Inoue Y,Yokota T,Sekitani T,Kaneko A,Woo T,Kobayashi S,Shibuya T,Tanaka M,Kosukegawa H,Saito I,Isoyama T,Abe Y,Yambe T,Someya T,Sekino M

    更新日期:2017-05-01 00:00:00

  • Three-dimensional modeling and quantitative analysis of gap junction distributions in cardiac tissue.

    abstract::Gap junctions play a fundamental role in intercellular communication in cardiac tissue. Various types of heart disease including hypertrophy and ischemia are associated with alterations of the spatial arrangement of gap junctions. Previous studies applied two-dimensional optical and electron-microscopy to visualize ga...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-011-0369-3

    authors: Lackey DP,Carruth ED,Lasher RA,Boenisch J,Sachse FB,Hitchcock RW

    更新日期:2011-11-01 00:00:00

  • Stenosis Hemodynamics Disrupt the Endothelial Cell Glycocalyx by MMP Activity Creating a Proinflammatory Environment.

    abstract::Hemodynamic forces are known to be able to induce an inflammatory phenotype in endothelial cells (ECs). The EC glycocalyx (GCX) is a dynamic structure which is regulated in response to different stimuli and hypothesized as an important contributor to the mechanotransduction of wall shear stresses (WSS). In this work, ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-017-1846-0

    authors: Cooper S,McDonald K,Burkat D,Leask RL

    更新日期:2017-09-01 00:00:00

  • Multi-scale computational models of pro-angiogenic treatments in peripheral arterial disease.

    abstract::The induction of angiogenesis is a promising therapeutic strategy for the amelioration of peripheral arterial disease (PAD). This occlusive disease results in muscle ischemia, and neovascularization is a route to increasing the perfusion in the tissue. The vascular endothelial growth factor (VEGF) family of potent pro...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-007-9303-0

    authors: Mac Gabhann F,Ji JW,Popel AS

    更新日期:2007-06-01 00:00:00

  • Engineering structurally organized cartilage and bone tissues.

    abstract::The field of tissue engineering promises to deliver biological substitutes to repair or replace tissues in the body that have been injured or diseased. The clinical demand for musculoskeletal tissues is particularly high, especially for cartilage and bone defects. Although they are generally considered biologically si...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1023/b:abme.0000007799.60142.78

    authors: Sharma B,Elisseeff JH

    更新日期:2004-01-01 00:00:00

  • Pulsatile flow in tubes of elliptic cross sections.

    abstract::The compression of blood vessels by surrounding tissue is an important problem in hemodynamics, most prominently in studies relating to the heart. In this study we consider a long tube of elliptic cross section as an idealization of the geometry of a compressed blood vessel. An exact solution of the governing equation...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.106

    authors: Haslam M,Zamir M

    更新日期:1998-09-01 00:00:00

  • Interaction between high frequency jet ventilation and cardiovascular function.

    abstract::We have studied the interaction of high frequency jet ventilation with cardiovascular pressures and flows. Results in dogs show that the amplitude of all intrathoracic pressures and flows fluctuate with a frequency equal to the difference between the heart rate and ventilator rate. The magnitude of this amplitude vari...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02584287

    authors: Mitzner W,Gioia F,Weinmann GG,Robotham JL,Ehrlich W

    更新日期:1987-01-01 00:00:00

  • Do increased electrogastrographic frequencies always correspond to internal tachygastria?

    abstract::This study was undertaken to investigate the possible origin of some cutaneously recorded higher frequency electrogastrographic signals. Computer modeling of gastric electrical uncoupling was performed using previously described conoidal dipole model. Cutaneous electrogastrograms were simulated after uncoupling was in...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:

    authors: Mintchev MP,Bowes KL

    更新日期:1997-11-01 00:00:00

  • Theoretical study of the effects of vascular smooth muscle contraction on strain and stress distributions in arteries.

    abstract::To study the effects of smooth muscle contraction and relaxation on the strain and stress distribution in the vascular wall, a mathematical model was proposed. The artery was assumed to be a thick-walled orthotropic tube made of nonlinear, incompressible elastic material. Considering that the contraction of smooth mus...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.191

    authors: Rachev A,Hayashi K

    更新日期:1999-07-01 00:00:00

  • The Role of Synthetic Extracellular Matrices in Endothelial Progenitor Cell Homing for Treatment of Vascular Disease.

    abstract::Poor vascular homeostasis drives many clinical disorders including diabetes, arthritis, atherosclerosis, and peripheral artery disease. Local tissue ischemia resultant of insufficient blood flow is a potent stimulus for recruitment of endothelial progenitor cells (EPCs). This mobilization and homing is a multi-step pr...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/s10439-015-1400-x

    authors: Williams PA,Silva EA

    更新日期:2015-10-01 00:00:00

  • Characteristics of blood flow resistance under transverse vibration: red blood cell suspension in Dextran-40.

    abstract::Vibration under shear flow causes the reduction of flow resistance for shear-thinning fluids. The present study investigates the effect of vibration on the flow resistance of a nonaggregating red blood cell (RBC) suspension with a newly designed pressure-scanning capillary viscometer (PSCV). The PSCV was originally de...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1603751

    authors: Shin S,Ku Y,Suh JS,Moon SY,Jang JY

    更新日期:2003-10-01 00:00:00

  • Elastic properties of the composite outer hair cell wall.

    abstract::We propose a mathematical model for analyses of the elastic properties of the wall of the outer hair cell (OHC) in the inner ear. The model reflects the properties of the major components of the OHC wall: the subsurface cisternae, the cortical lattice, the plasma membrane, and the radial pillars. The wall is treated a...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.87

    authors: Spector AA,Brownell WE,Popel AS

    更新日期:1998-01-01 00:00:00