Modulation of rod photoreceptor potassium Kx current by divalent cations.

Abstract:

:Similarities between photoreceptor Kx channels and EAG and KCNQ channels suggest that the Kx channel may be related to one or both of these families of potassium channels. To provide a basis for further comparison of these channels, as well as to reveal the role of zinc (endogenously present in photoreceptors) in Kx channel modulation, we studied the effects of divalent cations on activation and kinetic properties of the noninactivating potassium current, I(Kx), in salamander rod photoreceptors. We found that divalent cations slowed the activation of I(Kx) and shifted its activation curve to positive potentials, effects attributable to surface charge screening. The effect of zinc on I(Kx) kinetics was considerably stronger than that expected from the activation curve shift alone. None of the divalent ions studied changed the monoexponential nature of I(Kx) activation. A simple model of a rod photoreceptor was created using NEURON software. In the model, zinc accelerated and sharpened the light response, broadening the frequency response of rod photoreceptors. Our results show that although the overall effects of divalent cations are in part due to surface charge screening effects, zinc also induced a specific change in I(Kx) activation kinetics, and this action profoundly alters rod response properties.

journal_name

Ann Biomed Eng

authors

Kourennyi DE,Liu X,Barnes S

doi

10.1114/1.1521415

subject

Has Abstract

pub_date

2002-01-01 00:00:00

pages

1196-203

issue

9

eissn

0090-6964

issn

1573-9686

journal_volume

30

pub_type

杂志文章
  • Zonal uniformity in mechanical properties of the chondrocyte pericellular matrix: micropipette aspiration of canine chondrons isolated by cartilage homogenization.

    abstract::The pericellular matrix (PCM) is a region of tissue that surrounds chondrocytes in articular cartilage and together with the enclosed cells is termed the chondron. Previous studies suggest that the mechanical properties of the PCM, relative to those of the chondrocyte and the extracellular matrix (ECM), may significan...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-005-4479-7

    authors: Guilak F,Alexopoulos LG,Haider MA,Ting-Beall HP,Setton LA

    更新日期:2005-10-01 00:00:00

  • Two methods for calculating the responses of photoreceptors to moving objects.

    abstract::The responses of photoreceptor cells to moving stimuli are crucial to understanding motion detection in visual systems. However, these responses are not well characterized quantitatively because they result from a combination of spatial optical behavior in the lens systems with temporal behavior in the phototransducti...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.58

    authors: Korenberg MJ,Juusola M,French AS

    更新日期:1998-03-01 00:00:00

  • Predictive Virtual Patient Modelling of Mechanical Ventilation: Impact of Recruitment Function.

    abstract::Mechanical ventilation is a life-support therapy for intensive care patients suffering from respiratory failure. To reduce the current rate of ventilator-induced lung injury requires ventilator settings that are patient-, time-, and disease-specific. A common lung protective strategy is to optimise the level of positi...

    journal_title:Annals of biomedical engineering

    pub_type: 临床试验,杂志文章

    doi:10.1007/s10439-019-02253-w

    authors: Morton SE,Knopp JL,Chase JG,Möller K,Docherty P,Shaw GM,Tawhai M

    更新日期:2019-07-01 00:00:00

  • Differential changes in the molecular stability of collagen from the pulmonary and aortic valves during the fetal-to-neonatal transition.

    abstract::During the fetal-to-neonatal transition, transvalvular pressures (TVPs) on the aortic and pulmonary valves change dramatically-but differently for each valve. We have examined changes in the molecular stability and crosslinking of collagen during this transition. Aortic and pulmonary valves were harvested from fetal a...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-0061-z

    authors: Aldous IG,Lee JM,Wells SM

    更新日期:2010-09-01 00:00:00

  • Kinematic analysis of the human temporomandibular joint.

    abstract::A kinematic analysis of the temporomandibular joint (TMJ) is developed to determine the range of motion of the mandible during normal opening and during special motions required for arthroscopic surgery. The translation of the mandible is restricted by the constraint of the ligaments. By accounting for the maximum all...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02368648

    authors: Kang QS,Updike DP,Salathe EP

    更新日期:1993-11-01 00:00:00

  • Nanoparticle deposition onto biofilms.

    abstract::We develop a mathematical model of nanoparticles depositing onto and penetrating into a biofilm grown in a parallel-plate flow cell. We carry out deposition experiments in a flow cell to support the modeling. The modeling and the experiments are motivated by the potential use of polymer nanoparticles as part of a trea...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-012-0626-0

    authors: Miller JK,Neubig R,Clemons CB,Kreider KL,Wilber JP,Young GW,Ditto AJ,Yun YH,Milsted A,Badawy HT,Panzner MJ,Youngs WJ,Cannon CL

    更新日期:2013-01-01 00:00:00

  • Use of pseudorandom noise in studies of auditory evoked potentials.

    abstract::The extent to which sensorineural systems such as the auditory system are nonlinear depends on the type of stimulus that is used, and the part of the system from which recordings are made. An estimate of the first-order Wiener kernel of the evoked response from the inferior colliculus to amplitude-modulated tones and ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02367379

    authors: Møller AR,Angelo RM

    更新日期:1988-01-01 00:00:00

  • Computational Modelling of Multi-folded Balloon Delivery Systems for Coronary Artery Stenting: Insights into Patient-Specific Stent Malapposition.

    abstract::Despite the clinical effectiveness of coronary artery stenting, percutaneous coronary intervention or "stenting" is not free of complications. Stent malapposition (SM) is a common feature of "stenting" particularly in challenging anatomy, such as that characterized by long, tortuous and bifurcated segments. SM is an i...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-014-1237-8

    authors: Ragkousis GE,Curzen N,Bressloff NW

    更新日期:2015-08-01 00:00:00

  • Sensitivity of indentation testing to step-off edges and interface integrity in cartilage repair.

    abstract::Step-off edges and tissue interfaces are prevalent in cartilage injury such as after intra-articular fracture and reduction, and in focal defects and surgical repair procedures such as osteochondral graft implantation. It would be useful to assess the function of injured or donor tissues near such step-off edges and t...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1023/b:abme.0000017553.01798.12

    authors: Bae WC,Law AW,Amiel D,Sah RL

    更新日期:2004-03-01 00:00:00

  • Prediction of hip fracture can be significantly improved by a single biomedical indicator.

    abstract::Femoral neck fractures are a relevant clinical and social problem. The aim of this study was to improve the prediction of patients at-risk of femoral neck fracture with respect to the current densitometric-based methods. In particular, finite element models were used to assess the prediction accuracy obtained by combi...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1495866

    authors: Testi D,Viceconti M,Cappello A,Gnudi S

    更新日期:2002-06-01 00:00:00

  • Acoustic Emissions as a Non-invasive Biomarker of the Structural Health of the Knee.

    abstract::The longitudinal assessment of joint health is a long-standing issue in the management of musculoskeletal injuries. The acoustic emissions (AEs) produced by joint articulation could serve as a biomarker for joint health assessment, but their use has been limited by a lack of mechanistic understanding of their creation...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-019-02333-x

    authors: Whittingslow DC,Jeong HK,Ganti VG,Kirkpatrick NJ,Kogler GF,Inan OT

    更新日期:2020-01-01 00:00:00

  • Influence of autoregressive model parameter uncertainty on spectral estimates of heart rate dynamics.

    abstract::Linear autoregressive (AR) model-based heart rate (HR) spectral analysis has been widely used to study HR dynamics. Owing to system and measurement noise, the parameters of an AR model have intrinsic statistical uncertainty. In this study, we evaluate how this AR parameter uncertainty can translate to uncertainty in H...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02368320

    authors: Christini DJ,Kulkarni A,Rao S,Stutman ER,Bennett FM,Hausdorff JM,Oriol N,Lutchen KR

    更新日期:1995-03-01 00:00:00

  • A single equivalent moving dipole model: an efficient approach for localizing sites of origin of ventricular electrical activation.

    abstract::We propose a new method for guiding catheter ablation procedures to abolish sites of origin of arrhythmias. This method models both cardiac electrical activity and current pulses delivered from the tip of the ablation catheter with a single equivalent moving dipole (SEMD). The SEMD parameters are obtained from analysi...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1567281

    authors: Armoundas AA,Feldman AB,Mukkamala R,Cohen RJ

    更新日期:2003-05-01 00:00:00

  • Soft 3D-Printed Phantom of the Human Kidney with Collecting System.

    abstract::Organ models are used for planning and simulation of operations, developing new surgical instruments, and training purposes. There is a substantial demand for in vitro organ phantoms, especially in urological surgery. Animal models and existing simulator systems poorly mimic the detailed morphology and the physical pr...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-016-1757-5

    authors: Adams F,Qiu T,Mark A,Fritz B,Kramer L,Schlager D,Wetterauer U,Miernik A,Fischer P

    更新日期:2017-04-01 00:00:00

  • Shear stress distribution in the trabeculae of human vertebral bone.

    abstract::The statistical distribution of von Mises stress in the trabeculae of human vertebral cancellous bone was estimated using large-scale finite element models. The goal was to test the hypothesis that average trabecular von Mises stress is correlated to the maximum trabecular level von Mises stress. The hypothesis was pr...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1318928

    authors: Fyhrie DP,Hoshaw SJ,Hamid MS,Hou FJ

    更新日期:2000-01-01 00:00:00

  • A COVID-19 Airway Management Innovation with Pragmatic Efficacy Evaluation: The Patient Particle Containment Chamber.

    abstract::The unique resource constraints, urgency, and virulence of the coronavirus disease 2019 pandemic has sparked immense innovation in the development of barrier devices to protect healthcare providers from infectious airborne particles generated by patients during airway management interventions. Of the existing devices,...

    journal_title:Annals of biomedical engineering

    pub_type: 社论

    doi:10.1007/s10439-020-02599-6

    authors: Maloney LM,Yang AH,Princi RA,Eichert AJ,Hébert DR,Kupec TV,Mertz AE,Vasyltsiv R,Vijaya Kumar TM,Walker GJ,Peralta EJ,Hoffman JL,Yin W,Page CR

    更新日期:2020-10-01 00:00:00

  • Functional augmentation of naturally-derived materials for tissue regeneration.

    abstract::Tissue engineering strategies have utilized a wide spectrum of synthetic and naturally-derived scaffold materials. Synthetic scaffolds are better defined and offer the ability to precisely and reproducibly control their properties, while naturally-derived scaffolds typically have inherent biological and structural pro...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/s10439-014-1192-4

    authors: Allen AB,Priddy LB,Li MT,Guldberg RE

    更新日期:2015-03-01 00:00:00

  • Analysis of electrically induced reentrant circuits in a sheet of myocardium.

    abstract::Understanding the complex spatiotemporal dynamics of action potential propagation in the heart during arrhythmia is exceedingly difficult. This study applies nonlinear dynamics tools to simplify this task. Using the results of a simulation of an electrical induction of reentry in a sheet of myocardium represented as a...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1581289

    authors: Larson C,Dragnev L,Trayanova N

    更新日期:2003-07-01 00:00:00

  • An artificial neural network approach to the predictive modeling of tensile force during renal suturing.

    abstract::Further understanding of the mechanical deformation and tear behavior of kidney during suturing helps to enhance surgical task execution that requires fine suture manipulation. This paper aims to develop a model to describe the relationship between the tensile force acting on suture line and the resulted kidney deform...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-012-0722-1

    authors: Yu D,Qing Y,Jianxun Z,Jun D

    更新日期:2013-04-01 00:00:00

  • Static magnetic fields promote osteoblast-like cells differentiation via increasing the membrane rigidity.

    abstract::The aim of this study was to test the differentiative effects of osteoblasts after treatment with a static magnetic field (SMF). MG63 osteoblast-like cells were exposed to a 0.4-T SMF. The differentiation markers were assessed by observing the changes in alkaline phosphatase activity and electron microscopy images. Me...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-007-9370-2

    authors: Chiu KH,Ou KL,Lee SY,Lin CT,Chang WJ,Chen CC,Huang HM

    更新日期:2007-11-01 00:00:00

  • Correction to: A High-Precision and Miniature Fiber Bragg Grating-Based Force Sensor for Tissue Palpation During Minimally Invasive Surgery.

    abstract::The second equation in the section "Definition of Objective Functions and Constraints" was corrected to fix a mismatch between the PDF and HTML versions of the article. ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,已发布勘误

    doi:10.1007/s10439-019-02413-y

    authors: Lv C,Wang S,Shi C

    更新日期:2020-01-01 00:00:00

  • Transport Analysis of Engineered Liver Tissue Fabricated Using a Capsule-Based, Modular Approach.

    abstract::The bioinspired, microscale tissue engineering approach has emerged in recent years as a promising alternative to preformed scaffolds. Using this approach, complex tissues and organs can be efficiently engineered from microscale modules to replicate the intricate architecture and physiology of vascularized organs and ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-018-02192-y

    authors: Annamalai RT,Matthew HWT

    更新日期:2019-05-01 00:00:00

  • An SSVEP-actuated brain computer interface using phase-tagged flickering sequences: a cursor system.

    abstract::This study presents a new steady-state visual evoked potential (SSVEP)-based brain computer interface (BCI). SSVEPs, induced by phase-tagged flashes in eight light emitting diodes (LEDs), were used to control four cursor movements (up, right, down, and left) and four button functions (on, off, right-, and left-clicks)...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-9964-y

    authors: Lee PL,Sie JJ,Liu YJ,Wu CH,Lee MH,Shu CH,Li PH,Sun CW,Shyu KK

    更新日期:2010-07-01 00:00:00

  • A review of approaches to mobility telemonitoring of the elderly in their living environment.

    abstract::Rapid technological advances have prompted the development of a wide range of telemonitoring systems to enable the prevention, early diagnosis and management, of chronic conditions. Remote monitoring can reduce the amount of recurring admissions to hospital, facilitate more efficient clinical visits with objective res...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/s10439-005-9068-2

    authors: Ní Scanaill C,Carew S,Barralon P,Noury N,Lyons D,Lyons GM

    更新日期:2006-04-01 00:00:00

  • An evaluation of population D-optimal designs via pharmacokinetic simulations.

    abstract::One goal of large scale clinical trials is to determine how a drug is processed by, and cleared from, the human body [i.e., its pharmacokinetic (PK) properties] and how these PK properties differ between individuals in a population (i.e., its population PK properties). Due to the high cost of these studies and the lim...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1533074

    authors: Hooker AC,Foracchia M,Dodds MG,Vicini P

    更新日期:2003-01-01 00:00:00

  • The pressure-volume relation in the left ventricle and the pump function of the heart.

    abstract::The concept of body force (force per unit volume) is introduced to account for the effect of the force generated in the radial direction by the active state of the myocardium in an elastic model of the left ventricle represented as a thick-walled cylinder contracting symmetrically. Experimental evidence for the validi...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02368077

    authors: Shoucri RM

    更新日期:1991-01-01 00:00:00

  • Rat aortic smooth muscle cells contract in response to serum and its components in a calcium independent manner.

    abstract::Diluted serum provides a model of interstitial fluid that can be used to study the response of smooth muscle cells (SMCs) to interstitial flow. The effect of serum and some of its components on SMC contraction (area reduction) and intracellular calcium ([Ca2+]i) response were characterized in rat aortic SMC in vitro. ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-004-7820-7

    authors: Ainslie K,Shi ZD,Garanich JS,Tarbell JM

    更新日期:2004-12-01 00:00:00

  • The Role of Synthetic Extracellular Matrices in Endothelial Progenitor Cell Homing for Treatment of Vascular Disease.

    abstract::Poor vascular homeostasis drives many clinical disorders including diabetes, arthritis, atherosclerosis, and peripheral artery disease. Local tissue ischemia resultant of insufficient blood flow is a potent stimulus for recruitment of endothelial progenitor cells (EPCs). This mobilization and homing is a multi-step pr...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/s10439-015-1400-x

    authors: Williams PA,Silva EA

    更新日期:2015-10-01 00:00:00

  • Geodesic based registration of sensor data and anatomical surface image data.

    abstract::This paper presents two related methods for registering an image of an anatomical object with data from sensors arranged on the object. One method is described with reference to a test case involving a rectangular electrode plaque disposed on a heart surface, which is imaged with MRI. Data from the electrodes is fused...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-007-9350-6

    authors: Hopenfeld B,Ashikaga H,McVeigh ER

    更新日期:2007-10-01 00:00:00

  • Real-Time linux dynamic clamp: a fast and flexible way to construct virtual ion channels in living cells.

    abstract::We describe a system for real-time control of biological and other experiments. This device, based around the Real-Time Linux operating system, was tested specifically in the context of dynamic clamping, a demanding real-time task in which a computational system mimics the effects of nonlinear membrane conductances in...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1408929

    authors: Dorval AD,Christini DJ,White JA

    更新日期:2001-10-01 00:00:00