Accuracy of Functional and Predictive Methods to Calculate the Hip Joint Center in Young Non-pathologic Asymptomatic Adults with Dual Fluoroscopy as a Reference Standard.

Abstract:

:Predictions from biomechanical models of gait may be sensitive to joint center locations. Most often, the hip joint center (HJC) is derived from locations of reflective markers adhered to the skin. Here, predictive techniques use regression equations of pelvic anatomy to estimate the HJC, whereas functional methods track motion of markers placed at the pelvis and femur during a coordinated motion. Skin motion artifact may introduce errors in the estimate of HJC for both techniques. Quantifying the accuracy of these methods is an area of open investigation. In this study, we used dual fluoroscopy (DF) (a dynamic X-ray imaging technique) and three-dimensional reconstructions from computed tomography images, to measure HJC locations in vivo. Using dual fluoroscopy as the reference standard, we then assessed the accuracy of three predictive and two functional methods. Eleven non-pathologic subjects were imaged with DF and reflective skin marker motion capture. Additionally, DF-based solutions generated virtual markers placed on bony landmarks, which were input to the predictive and functional methods to determine if estimates of the HJC improved. Using skin markers, functional methods had better mean agreement with the HJC measured by DF (11.0 ± 3.3 mm) than predictive methods (18.1 ± 9.5 mm); estimates from functional and predictive methods improved when using the DF-based solutions (1.3 ± 0.9 and 17.5 ± 8.6 mm, respectively). The Harrington method was the best predictive technique using both skin markers (13.2 ± 6.5 mm) and DF-based solutions (10.6 ± 2.5 mm). The two functional methods had similar accuracy using skin makers (11.1 ± 3.6 and 10.8 ± 3.2 mm) and DF-based solutions (1.2 ± 0.8 and 1.4 ± 1.0 mm). Overall, functional methods were superior to predictive methods for HJC estimation. However, the improvements observed when using the DF-based solutions suggest that skin motion artifact is a large source of error for the functional methods.

journal_name

Ann Biomed Eng

authors

Fiorentino NM,Kutschke MJ,Atkins PR,Foreman KB,Kapron AL,Anderson AE

doi

10.1007/s10439-015-1522-1

subject

Has Abstract

pub_date

2016-07-01 00:00:00

pages

2168-80

issue

7

eissn

0090-6964

issn

1573-9686

pii

10.1007/s10439-015-1522-1

journal_volume

44

pub_type

临床试验,杂志文章
  • Geodesic based registration of sensor data and anatomical surface image data.

    abstract::This paper presents two related methods for registering an image of an anatomical object with data from sensors arranged on the object. One method is described with reference to a test case involving a rectangular electrode plaque disposed on a heart surface, which is imaged with MRI. Data from the electrodes is fused...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-007-9350-6

    authors: Hopenfeld B,Ashikaga H,McVeigh ER

    更新日期:2007-10-01 00:00:00

  • Quadratic phase coupling as a quantitative measure for the developing hippocampal formation.

    abstract::This paper presents the bispectral analysis of the ontogeny of the hippocampal EEG recorded from the dentate gyrus and CA1, the primary sites that generate theta (theta) rhythm. The hippocampal EEG was collected during the vigilance state of rapid eye movement (REM) sleep of freely moving rats at 15, 30 and 90 days of...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.43

    authors: Ning T,Bronzino JD

    更新日期:1998-07-01 00:00:00

  • Microvascular endothelial cells exhibit optimal aspect ratio for minimizing flow resistance.

    abstract::A recent analytical solution of the three-dimensional Stokes flow through a bumpy tube predicts that for a given bump area, there exists an optimal circumferential wavenumber which minimizes flow resistance. This study uses measurements of microvessel endothelial cell morphology to test whether this prediction holds i...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-008-9467-2

    authors: Sumagin R,Brown CW 3rd,Sarelius IH,King MR

    更新日期:2008-04-01 00:00:00

  • The impedance of a spherical monopolar electrode.

    abstract::The impedance of a monopolar electrode immersed in an environmental volume conductor consists of two parts; the impedance of the active electrode-electrolyte interface, and the resistance of the environmental conductor. Two studies were carried out to quantitate these components. First, impedance-frequency data were c...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02368609

    authors: Ragheb T,Riegle S,Geddes LA,Amin V

    更新日期:1992-01-01 00:00:00

  • Design and hydrodynamic evaluation of a novel pulsatile bioreactor for biologically active heart valves.

    abstract::Biologically active heart valves (tissue engineered and recellularized tissue-derived heart valves) have the potential to offer enhanced function when compared to current replacement value therapies since they can possibly remodel, and grow to meet the needs of the patient, and not require chronic medication. However,...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/b:abme.0000036640.11387.4b

    authors: Hildebrand DK,Wu ZJ,Mayer JE Jr,Sacks MS

    更新日期:2004-08-01 00:00:00

  • Phospholipids identified on the pericardium and their ability to impart boundary lubrication.

    abstract::Phospholipids have been identified by thin-layer chromatography in appreciable quantities in pericardial fluid taken from 12 dogs and found to include sphingomyelin and phosphatidylcholines, -ethanolamines, -inositols and -serines--the cholines predominating. The extracts, the synthetic surfactants and a mixture of sy...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02584258

    authors: Hills BA,Butler BD

    更新日期:1985-01-01 00:00:00

  • Evaluation of stochastic differential equation approximation of ion channel gating models.

    abstract::Fox and Lu derived an algorithm based on stochastic differential equations for approximating the kinetics of ion channel gating that is simpler and faster than "exact" algorithms for simulating Markov process models of channel gating. However, the approximation may not be sufficiently accurate to predict statistics of...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-009-9635-z

    authors: Bruce IC

    更新日期:2009-04-01 00:00:00

  • Digital processing of the current noise evoked by kainate in cerebellar granule cells.

    abstract::Current induced in cultured cerebellar granule cells by the bath application of kainate (500 microM) was measured using the conventional patch-clamp technique. Two different kinds of responses were observed after the agonist perfusion. Some cells exhibited small inward whole-cell currents: 116 +/- 40 pA (7 cells) at a...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02684186

    authors: Cavalcanti S,Zona C

    更新日期:1997-05-01 00:00:00

  • Prediction of hip fracture can be significantly improved by a single biomedical indicator.

    abstract::Femoral neck fractures are a relevant clinical and social problem. The aim of this study was to improve the prediction of patients at-risk of femoral neck fracture with respect to the current densitometric-based methods. In particular, finite element models were used to assess the prediction accuracy obtained by combi...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1495866

    authors: Testi D,Viceconti M,Cappello A,Gnudi S

    更新日期:2002-06-01 00:00:00

  • Multidirectional pelvic floor muscle strength measurement.

    abstract::Pelvic floor muscle (PFM) strength measurement provides useful information for the study of pelvic floor dysfunctions. Vaginal digital palpation, intravaginal pressure measurements, and the use of a dynamometric speculum represent currently available clinical methods for evaluating PFM strength. However, none of these...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-009-9728-8

    authors: Saleme CS,Rocha DN,Del Vecchio S,Silva Filho AL,Pinotti M

    更新日期:2009-08-01 00:00:00

  • Bioengineering the skin-implant interface: the use of regenerative therapies in implanted devices.

    abstract::This discussion and review article focuses on the possible use of regenerative techniques applied to the interfaces between skin and medical implants. As is widely known, the area of contact between an implant and the skin--the skin-implant interface--is prone to recurrent and persistent problems originated from the l...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/s10439-010-9937-1

    authors: Peramo A,Marcelo CL

    更新日期:2010-06-01 00:00:00

  • Noninvasive recovery of acinar anatomic information from CO2 expirograms.

    abstract::A numerical single path model of respiratory gas exchange with distributed alveolar gas sources was used to estimate the anatomical changes in small peripheral airways such as occur in chronic obstructive pulmonary diseases (COPD). A previous sensitivity analysis of the single path model showed that decreasing total a...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02368236

    authors: Schwardt JD,Neufeld GR,Baumgardner JE,Scherer PW

    更新日期:1994-05-01 00:00:00

  • Personalized Perioperative Multi-scale, Multi-physics Heart Simulation of Double Outlet Right Ventricle.

    abstract::For treatment of complex congenital heart disease, computer simulation using a three-dimensional heart model may help to improve outcomes by enabling detailed preoperative evaluations. However, no highly integrated model that accurately reproduces a patient's pathophysiology, which is required for this simulation has ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02488-y

    authors: Kariya T,Washio T,Okada JI,Nakagawa M,Watanabe M,Kadooka Y,Sano S,Nagai R,Sugiura S,Hisada T

    更新日期:2020-06-01 00:00:00

  • Sensitivity analysis of an image-based solid tumor computational model with heterogeneous vasculature and porosity.

    abstract::An MR image-based computational model of a murine KHT sarcoma is presented that allows the calculation of plasma fluid and solute transport within tissue. Such image-based models of solid tumors may be used to optimize patient-specific therapies. This model incorporates heterogeneous vasculature and tissue porosity to...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-011-0349-7

    authors: Pishko GL,Astary GW,Mareci TH,Sarntinoranont M

    更新日期:2011-09-01 00:00:00

  • Vascular remodeling in autogenous arterio-venous fistulas by MRI and CFD.

    abstract::Hemodynamic parameters play an important role in regulating vascular remodeling in arterio-venous fistula (AVF) maturation. Investigating the changes in hemodynamic parameters during AVF maturation is expected to improve our understanding of fistula failure, but very little data on actual temporal changes in human AVF...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-012-0703-4

    authors: Sigovan M,Rayz V,Gasper W,Alley HF,Owens CD,Saloner D

    更新日期:2013-04-01 00:00:00

  • Preparation of chitosan/hydroxyapatite substrates with controllable osteoconductivity tracked by AFM.

    abstract::In this study, cell-material adhesive strength and cellular mechanical properties were measured using atomic force microscopy (AFM) to track cell attachment and osteogenic differentiation. First, chitosan substrates were treated with simulated body fluid (SBF) for various periods, resulting in substrates with differen...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-014-1162-x

    authors: Ho MH,Li CH,Hsiao SW,Thien DV

    更新日期:2015-04-01 00:00:00

  • Simulated epicardial potential maps during paced activation reflect myocardial fibrous structure.

    abstract::Using a three-dimensional propagation model of the human ventricular myocardium, we studied the role of fibrous structure in generating epicardial potential maps. This model represents the myocardium as an anisotropic bidomain with an equal anisotropy ratio, and it incorporates a realistic representation of anatomical...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.73

    authors: Hren R,Nenonen J,Horácek BM

    更新日期:1998-11-01 00:00:00

  • Wall Shear Stress Topological Skeleton Independently Predicts Long-Term Restenosis After Carotid Bifurcation Endarterectomy.

    abstract::Wall Shear Stress (WSS) topological skeleton, composed by fixed points and the manifolds linking them, reflects the presence of blood flow features associated to adverse vascular response. However, the influence of WSS topological skeleton on vascular pathophysiology is still underexplored. This study aimed to identif...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02607-9

    authors: Morbiducci U,Mazzi V,Domanin M,De Nisco G,Vergara C,Steinman DA,Gallo D

    更新日期:2020-12-01 00:00:00

  • Osteochondral interface tissue engineering using macroscopic gradients of bioactive signals.

    abstract::Continuous gradients exist at osteochondral interfaces, which may be engineered by applying spatially patterned gradients of biological cues. In the present study, a protein-loaded microsphere-based scaffold fabrication strategy was applied to achieve spatially and temporally controlled delivery of bioactive signals i...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-0028-0

    authors: Dormer NH,Singh M,Wang L,Berkland CJ,Detamore MS

    更新日期:2010-06-01 00:00:00

  • A computerized mass spectrometer and flowmeter system for respiratory gas measurements.

    abstract::Instrumentation systems for breath-to-breath analysis of respiratory gas exchange have been faulted by phase lags between various flow and composition signals and by difficulties in gathering and processing large amounts of data. The system described here represents an attempt to overcome these problems. Phase delays ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02367493

    authors: Sodal IE,Swanson GD,Micco AJ,Sprague F,Ellis DG

    更新日期:1983-01-01 00:00:00

  • Distribution of internal strains around bony prominences in pigs.

    abstract::Deep tissue injury (DTI) is a type of pressure ulcer in which tissue breakdown initiates at the bone-muscle interface under intact skin. Excessive deformation in the soft tissue, particularly around bony prominences, is believed to be one of the causes leading to the development of DTI. The main goal of this study was...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-012-0539-y

    authors: Solis LR,Liggins AB,Seres P,Uwiera RR,Poppe NR,Pehowich E,Thompson RB,Mushahwar VK

    更新日期:2012-08-01 00:00:00

  • Shear stress distribution in the trabeculae of human vertebral bone.

    abstract::The statistical distribution of von Mises stress in the trabeculae of human vertebral cancellous bone was estimated using large-scale finite element models. The goal was to test the hypothesis that average trabecular von Mises stress is correlated to the maximum trabecular level von Mises stress. The hypothesis was pr...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1318928

    authors: Fyhrie DP,Hoshaw SJ,Hamid MS,Hou FJ

    更新日期:2000-01-01 00:00:00

  • Countercurrent extraction of sparingly soluble gases for membrane introduction mass spectrometry.

    abstract::Membrane introduction mass spectrometry has been applied to inert gas measurements in blood and tissue, but gases with low blood solubility are associated with reduced sensitivity. Countercurrent extraction of inert gases from a blood sample into a water carrier phase has the potential to extract most of the gas sampl...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02684170

    authors: Baumgardner JE,Neufeld GR

    更新日期:1997-09-01 00:00:00

  • Measurement of in vivo stress resultants in neurulation-stage amphibian embryos.

    abstract::In order to obtain the first quantitative measurements of the in vivo stresses in early-stage amphibian embryos, we developed a novel instrument that uses a pair of parallel wires that are glued to the surface of an embryo normal to the direction in which the stress is to be determined. When a slit is made parallel to...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-006-9250-1

    authors: Benko R,Brodland GW

    更新日期:2007-04-01 00:00:00

  • Mitral Valve Regurgitation with a Rotary Left Ventricular Assist Device: The Haemodynamic Effect of Inlet Cannulation Site and Speed Modulation.

    abstract::Mitral valve regurgitation (MVR) is common in patients receiving left ventricular assist device (LVAD) support, however the haemodynamic effect of MVR is not entirely clear. This study evaluated the haemodynamic effect of MVR with LVAD support and the influence of inflow cannulation site and LVAD speed modulation. Lef...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-016-1579-5

    authors: Gregory SD,Stevens MC,Wu EL,Pauls JP,Kleinheyer M,Fraser JF

    更新日期:2016-09-01 00:00:00

  • Probabilistic evaluation of predicted force sensitivity to muscle attachment and glenohumeral stability uncertainty.

    abstract::A major benefit of computational modeling in biomechanics research is its ability to estimate internal muscular demands given limited input information. However, several assumptions regarding model parameters and constraints may influence model outputs. This research evaluated the influence of model parameter variabil...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-014-1035-3

    authors: Chopp-Hurley JN,Langenderfer JE,Dickerson CR

    更新日期:2014-09-01 00:00:00

  • Parametric comparisons of intracranial mechanical responses from three validated finite element models of the human head.

    abstract::A number of human head finite element (FE) models have been developed from different research groups over the years to study the mechanisms of traumatic brain injury. These models can vary substantially in model features and parameters, making it important to evaluate whether simulation results from one model are read...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-013-0907-2

    authors: Ji S,Ghadyani H,Bolander RP,Beckwith JG,Ford JC,McAllister TW,Flashman LA,Paulsen KD,Ernstrom K,Jain S,Raman R,Zhang L,Greenwald RM

    更新日期:2014-01-01 00:00:00

  • Net change in periosteal strain during stance shift loading after surgery correlates to rapid de novo bone generation in critically sized defects.

    abstract::In an ovine femur model, proliferative woven bone fills critically sized defects enveloped by periosteum within 2 weeks of treatment with the one-stage bone-transport surgery. We hypothesize that mechanical loading modulates this process. Using high-definition optical strain measurements we determined prevailing perio...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-0242-9

    authors: McBride SH,Dolejs S,Brianza S,Knothe U,Knothe Tate ML

    更新日期:2011-05-01 00:00:00

  • Muscle-tendon model with length history-dependent activation-velocity coupling.

    abstract::We developed muscle-tendon models incorporating Hill-type structure and length-dependent coupling between activation and velocity. The models were evaluated in electrically stimulated cat soleus muscles. Dynamic model parameters were estimated by a nonlinear parameter estimation algorithm from input-output data obtain...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.93

    authors: Shue GH,Crago PE

    更新日期:1998-05-01 00:00:00

  • Strontium ranelate prevents bone loss in a rat model of localized muscle paralysis.

    abstract::Twenty-one 3.5-month-old female Sprague-Dawley rats were randomly assigned to three groups: BTX group, in which each rat received a single intramuscular injection of 2 U of Clostridium botulinum toxin (BTX) in the quadriceps femoris muscle of the right hind limb; BTX + SR group, in which each rat received a BTX inject...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-011-0406-2

    authors: Sheng ZF,Ma YL,Tong D,Fang DY,Liang QC,Liu LH,Zhang J,Liao EY

    更新日期:2012-03-01 00:00:00