Sensitivity analysis of an image-based solid tumor computational model with heterogeneous vasculature and porosity.

Abstract:

:An MR image-based computational model of a murine KHT sarcoma is presented that allows the calculation of plasma fluid and solute transport within tissue. Such image-based models of solid tumors may be used to optimize patient-specific therapies. This model incorporates heterogeneous vasculature and tissue porosity to account for nonuniform perfusion of an MR-visible tracer, gadolinium-diethylenetriamine pentaacetic acid (Gd-DTPA). Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) was conducted following intravenous infusion of Gd-DTPA to provide 1 h of tracer-concentration distribution data within tissue. Early time points (19 min) were used to construct 3D K(trans) and porosity maps using a two-compartment model; tracer transport was predicted at later time points using a 3D porous media model. Model development involved selecting an arterial input function (AIF) and conducting a sensitivity analysis of model parameters (tissue, vascular, and initial estimation of solute concentration in plasma) to investigate the effects on transport for a specific tumor. The developed model was then used to predict transport in two additional tumors. The sensitivity analysis suggests that plasma fluid transport is more sensitive to parameter changes than solute transport due to the dominance of transvascular exchange. Gd-DTPA distribution was similar to experimental patterns, but differences in Gd-DTPA magnitude at later time points may result from inaccurate selection of AIF. Thus, accurate AIF estimation is important for later time point prediction of low molecular weight tracer or drug transport in smaller tumors.

journal_name

Ann Biomed Eng

authors

Pishko GL,Astary GW,Mareci TH,Sarntinoranont M

doi

10.1007/s10439-011-0349-7

subject

Has Abstract

pub_date

2011-09-01 00:00:00

pages

2360-73

issue

9

eissn

0090-6964

issn

1573-9686

journal_volume

39

pub_type

杂志文章
  • Arterial luminal curvature and fibrous-cap thickness affect critical stress conditions within atherosclerotic plaque: an in vivo MRI-based 2D finite-element study.

    abstract::High mechanical stress in atherosclerotic plaques at vulnerable sites, called critical stress, contributes to plaque rupture. The site of minimum fibrous cap (FC) thickness (FC(MIN)) and plaque shoulder are well-documented vulnerable sites. The inherent weakness of the FC material at the thinnest point increases the s...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-0078-3

    authors: Teng Z,Sadat U,Li Z,Huang X,Zhu C,Young VE,Graves MJ,Gillard JH

    更新日期:2010-10-01 00:00:00

  • The impedance of a spherical monopolar electrode.

    abstract::The impedance of a monopolar electrode immersed in an environmental volume conductor consists of two parts; the impedance of the active electrode-electrolyte interface, and the resistance of the environmental conductor. Two studies were carried out to quantitate these components. First, impedance-frequency data were c...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02368609

    authors: Ragheb T,Riegle S,Geddes LA,Amin V

    更新日期:1992-01-01 00:00:00

  • Chest Wall Kinematics Using Triangular Cosserat Point Elements in Healthy and Neuromuscular Subjects.

    abstract::Optoelectronic plethysmography (OEP) is a noninvasive method for assessing lung volume variations and the contributions of different anatomical compartments of the chest wall (CW) through measurements of the motion of markers attached to the CW surface. The present study proposes a new method for analyzing the local C...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-017-1840-6

    authors: Solav D,Meric H,Rubin MB,Pradon D,Lofaso F,Wolf A

    更新日期:2017-08-01 00:00:00

  • Redirection of neurite outgrowth by coupling chondroitin sulfate proteoglycans to polymer membranes.

    abstract::Upon nerve injury, the body creates an environment consisting of permissive and non-permissive cues that instruct the function of cells involved in nerve repair. Among other roles, the developing extracellular matrix (ECM) acts as an underlying substrate to guide the union of neurites extending from the proximal stump...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-014-0991-y

    authors: Man AJ,Leach JK,Bannerman P

    更新日期:2014-06-01 00:00:00

  • A Review of Material Degradation Modelling for the Analysis and Design of Bioabsorbable Stents.

    abstract::The field of percutaneous coronary intervention has witnessed many progressions over the last few decades, more recently with the advancement of fully degradable bioabsorbable stents. Bioabsorbable materials, such as metallic alloys and aliphatic polyesters, have the potential to yield stents which provide temporary s...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/s10439-015-1413-5

    authors: Boland EL,Shine R,Kelly N,Sweeney CA,McHugh PE

    更新日期:2016-02-01 00:00:00

  • Pixel-Based DXA-Derived Structural Properties Strongly Correlate with pQCT Measures at the One-Third Distal Femur Site.

    abstract::While bone mineral density has been traditionally used to quantify fracture risk for individuals with spinal cord injuries, recent studies are including engineering measurements such as section modulus and cross sectional moment of inertia. These are almost exclusively calculated by peripheral QCT scanners which, unli...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-017-1796-6

    authors: Baker AM,Wagner DW,Kiratli BJ,Beaupre GS

    更新日期:2017-05-01 00:00:00

  • Real-Time linux dynamic clamp: a fast and flexible way to construct virtual ion channels in living cells.

    abstract::We describe a system for real-time control of biological and other experiments. This device, based around the Real-Time Linux operating system, was tested specifically in the context of dynamic clamping, a demanding real-time task in which a computational system mimics the effects of nonlinear membrane conductances in...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1408929

    authors: Dorval AD,Christini DJ,White JA

    更新日期:2001-10-01 00:00:00

  • Stochastic system identification of skin properties: linear and wiener static nonlinear methods.

    abstract::Wiener static nonlinear system identification was used to study the linear dynamics and static nonlinearities in the response of skin and underlying tissue under indentation in vivo. A device capable of measuring the dynamic mechanical properties of bulk skin tissue was developed and it incorporates a custom-built Lor...

    journal_title:Annals of biomedical engineering

    pub_type: 临床试验,杂志文章

    doi:10.1007/s10439-012-0580-x

    authors: Chen Y,Hunter IW

    更新日期:2012-10-01 00:00:00

  • CareToy: Stimulation and Assessment of Preterm Infant's Activity Using a Novel Sensorized System.

    abstract::Early intervention programs aim at improving cognitive and motor outcomes of preterm infants. Intensive custom-tailored training activities are usually accompanied by assessment procedures, which have shortcomings, such as subjectivity, complex setups, and need for structured environments. A novel sensorized system, c...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-016-1669-4

    authors: Rihar A,Sgandurra G,Beani E,Cecchi F,Pašič J,Cioni G,Dario P,Mihelj M,Munih M

    更新日期:2016-12-01 00:00:00

  • Fatigue of Metallic Stents: From Clinical Evidence to Computational Analysis.

    abstract::The great success of stents in treating cardiovascular disease is actually undermined by their long-term fatigue failure. The high variability of stent failure incidence suggests that it is due to several correlated aspects, such as loading conditions, material properties, component design, surgical procedure, and pat...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1447-8

    authors: Auricchio F,Constantinescu A,Conti M,Scalet G

    更新日期:2016-02-01 00:00:00

  • Effects of tetraethylammonium on Kx channels and simulated light response in rod photoreceptors.

    abstract::Rod photoreceptors express a unique type of noninactivating potassium channels, Kx channels, which play an important role in setting the dark potential and participate in shaping the light response. Biophysical studies of Kx channels are limited. For example, the effects of a conventional blocker of potassium channels...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/b:abme.0000042230.99614.8d

    authors: Liu XD,Kourennyi DE

    更新日期:2004-10-01 00:00:00

  • Thermal analysis of the bone surface induced by laser radiation.

    abstract::High energy laser has emerged to be an important surgical tool in medical technology. However, the application of laser energy to drill or cut a bone is still in an experimental state. In order to estimate the adequacy of laser heating of bone surface and at the same time minimize the damage to the bone tissue, we dev...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02363565

    authors: Chen II,Saha S

    更新日期:1987-01-01 00:00:00

  • Electrophysiological modeling of fibroblasts and their interaction with myocytes.

    abstract::Experimental studies have shown that cardiac fibroblasts are electrically inexcitable, but can contribute to electrophysiology of myocardium in various manners. The aim of this computational study was to give insights in the electrophysiological role of fibroblasts and their interaction with myocytes. We developed a m...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-007-9405-8

    authors: Sachse FB,Moreno AP,Abildskov JA

    更新日期:2008-01-01 00:00:00

  • Holographic interferometry: a critique of the technique and its potential for biomedical measurements.

    abstract::Double-exposure holographic interferometry is a contactless whole-field method. Dimensional changes are visualized as a series of interference fringes overlaid on the holographic image of the femur, where each fringe represents 0.316 micron (half the wavelength of the laser light) of motion. Interferograms for intact ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02364168

    authors: Ovryn B,Manley MT,Stern LS

    更新日期:1987-01-01 00:00:00

  • Permeability analysis of neuroactive drugs through a dynamic microfluidic in vitro blood-brain barrier model.

    abstract::This paper presents the permeability analysis of neuroactive drugs and correlation with in vivo brain/plasma ratios in a dynamic microfluidic blood-brain barrier (BBB) model. Permeability of seven neuroactive drugs (Ethosuximide, Gabapentin, Sertraline, Sunitinib, Traxoprodil, Varenicline, PF-304014) and trans-endothe...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-014-1086-5

    authors: Booth R,Kim H

    更新日期:2014-12-01 00:00:00

  • Supraphysiological thermal injury in different human bladder carcinoma cell lines.

    abstract::Depending on the duration of exposure to supraphysiological temperatures, cellular proteins and organelles can suffer from structural alternations and irreversible denaturation, which may induce cell death. The thermotolerance of three human urinary bladder carcinoma cell lines, TSGH-8301, J82 and TCC-SUP (cytological...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-009-9773-3

    authors: Jen CP,Huang CT,Tsai CH

    更新日期:2009-11-01 00:00:00

  • Progression of abdominal aortic aneurysm towards rupture: refining clinical risk assessment using a fully coupled fluid-structure interaction method.

    abstract::Rupture of abdominal aortic aneurysm (AAA) is associated with high mortality rates. Risk of rupture is multi-factorial involving AAA geometric configuration, vessel tortuosity, and the presence of intraluminal pathology. Fluid structure interaction (FSI) simulations were conducted in patient based computed tomography ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-014-1224-0

    authors: Xenos M,Labropoulos N,Rambhia S,Alemu Y,Einav S,Tassiopoulos A,Sakalihasan N,Bluestein D

    更新日期:2015-01-01 00:00:00

  • Static magnetic fields promote osteoblast-like cells differentiation via increasing the membrane rigidity.

    abstract::The aim of this study was to test the differentiative effects of osteoblasts after treatment with a static magnetic field (SMF). MG63 osteoblast-like cells were exposed to a 0.4-T SMF. The differentiation markers were assessed by observing the changes in alkaline phosphatase activity and electron microscopy images. Me...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-007-9370-2

    authors: Chiu KH,Ou KL,Lee SY,Lin CT,Chang WJ,Chen CC,Huang HM

    更新日期:2007-11-01 00:00:00

  • Strength and electron features of irradiated bone.

    abstract::Radiation applied for therapy and diagnostics damages molecular/atomic couples of biotissues, bones being among them. As a result, electron peculiarities and mechanical behavior of the latter are altered. Correlation between strength of the irradiated bone and its electron features explored due to photo- and exoelectr...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1114/1.1424911

    authors: Dekhtyar Y

    更新日期:2001-12-01 00:00:00

  • Machine Learning Classification of Verified Head Impact Exposure Strengthens Associations with Brain Changes.

    abstract::Cumulative exposure to head impacts during contact sports can elicit potentially deleterious brain white matter alterations in young athletes. Head impact exposure is commonly quantified using wearable sensors; however, these sensors tend to overestimate the number of true head impacts that occur and may obfuscate pot...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02662-2

    authors: DiCesare CA,Green B,Yuan W,Diekfuss JA,Barber Foss KD,Dudley J,Qin Y,Wang P,Myer GD

    更新日期:2020-12-01 00:00:00

  • Electrically active bioceramics: a review of interfacial responses.

    abstract::Electrical potentials in mechanically loaded bone have been implicated as signals in the bone remodeling cycle. Recently, interest has grown in exploiting this phenomenon to develop electrically active ceramics for implantation in hard tissue which may induce improved biological responses. Both polarized hydroxyapatit...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/s10439-010-9977-6

    authors: Baxter FR,Bowen CR,Turner IG,Dent AC

    更新日期:2010-06-01 00:00:00

  • Impact of Pulmonary Venous Inflow on Cardiac Flow Simulations: Comparison with In Vivo 4D Flow MRI.

    abstract::Blood flow simulations are making their way into the clinic, and much attention is given to estimation of fractional flow reserve in coronary arteries. Intracardiac blood flow simulations also show promising results, and here the flow field is expected to depend on the pulmonary venous (PV) flow rates. In the absence ...

    journal_title:Annals of biomedical engineering

    pub_type: 临床试验,杂志文章

    doi:10.1007/s10439-018-02153-5

    authors: Lantz J,Gupta V,Henriksson L,Karlsson M,Persson A,Carlhäll CJ,Ebbers T

    更新日期:2019-02-01 00:00:00

  • Behavior of human mesenchymal stem cells in fibrin-based vascular tissue engineering constructs.

    abstract::A limitation of current tissue engineering vascular graft technology is the provision of an expandable, autologous cell source. By harnessing the multipotency of mesenchymal stem cells (MSC), it is hoped that functional vascular cells can be produced. To date, a range of 2D and 3D environments have been investigated f...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-9912-x

    authors: O'Cearbhaill ED,Murphy M,Barry F,McHugh PE,Barron V

    更新日期:2010-03-01 00:00:00

  • A Dual-Mode Bioreactor System for Tissue Engineered Vascular Models.

    abstract::In the past decades, vascular tissue engineering has made great strides towards bringing engineered vascular tissues to the clinics and, in parallel, obtaining in-lab tools for basic research. Herein, we propose the design of a novel dual-mode bioreactor, useful for the fabrication (construct mode) and in vitro stimul...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-017-1813-9

    authors: Bono N,Meghezi S,Soncini M,Piola M,Mantovani D,Fiore GB

    更新日期:2017-06-01 00:00:00

  • Simulated epicardial potential maps during paced activation reflect myocardial fibrous structure.

    abstract::Using a three-dimensional propagation model of the human ventricular myocardium, we studied the role of fibrous structure in generating epicardial potential maps. This model represents the myocardium as an anisotropic bidomain with an equal anisotropy ratio, and it incorporates a realistic representation of anatomical...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.73

    authors: Hren R,Nenonen J,Horácek BM

    更新日期:1998-11-01 00:00:00

  • Measurement of three-dimensional anisotropic diffusion by multiphoton fluorescence recovery after photobleaching.

    abstract::The multiphoton fluorescence recovery after photobleaching (MP-FRAP) technique has been developed to measure the three-dimensional (3D) solute diffusion within biological systems. However, current 3D MP-FRAP models are based on isotropic diffusion and spatial domain analysis. The 3D anisotropic diffusion and frequency...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-013-0939-7

    authors: Shi C,Cisewski SE,Bell PD,Yao H

    更新日期:2014-03-01 00:00:00

  • Effect of mechanical strain on solute diffusion in human TMJ discs: an electrical conductivity study.

    abstract::This study investigated the effect of mechanical strain on solute diffusion in human TMJ discs (mean cadaver age 77.8) using the electrical conductivity method. The electrical conductivity, as well as small ion diffusivity, of male and female TMJ discs was determined under three compressive strains. In the male group,...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-013-0840-4

    authors: Wright GJ,Kuo J,Shi C,Bacro TR,Slate EH,Yao H

    更新日期:2013-11-01 00:00:00

  • Selective stimulation of latissimus dorsi muscle for cardiac assist.

    abstract::The contractile power of the latissimus dorsi muscle (LDM) is used in skeletal muscle cardiac assist (SMCA) to augment the blood pumping ability of a failing heart. The LDM has three anatomically distinct, independently innervate segments-the transverse, oblique, and lateral. There are potential advantages to selectiv...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.164

    authors: Thompson DR,Michele JJ,Cheever EA,George DT

    更新日期:1999-01-01 00:00:00

  • BMP-2 gene modified canine bMSCs promote ectopic bone formation mediated by a nonviral PEI derivative.

    abstract::The study was to explore the effects of BMP-2 gene modified canine bone marrow stromal cells (bMSCs) mediated by a nonviral PEI derivative (GenEscort™ II) in promoting bone formation in vitro and in vivo. Canine bMSCs were cultured and transfected with plasmids containing bone morphogenetic protein-2 gene (pBMP-2) or ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-011-0276-7

    authors: Lü K,Zeng D,Zhang Y,Xia L,Xu L,Kaplan DL,Jiang X,Zhang F

    更新日期:2011-06-01 00:00:00

  • Gaussian pulse decomposition: an intuitive model of electrocardiogram waveforms.

    abstract::This study presents a novel approach to modeling the electrocardiogram (ECG): the Gaussian pulse decomposition. Constituent waves of the ECG are decomposed into and represented by Gaussian pulses using an iterative algorithm: the chip away decomposition (ChAD) algorithm. At each iteration, a nonlinear minimization met...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02648039

    authors: Suppappola S,Sun Y,Chiaramida SA

    更新日期:1997-03-01 00:00:00