Arterial luminal curvature and fibrous-cap thickness affect critical stress conditions within atherosclerotic plaque: an in vivo MRI-based 2D finite-element study.

Abstract:

:High mechanical stress in atherosclerotic plaques at vulnerable sites, called critical stress, contributes to plaque rupture. The site of minimum fibrous cap (FC) thickness (FC(MIN)) and plaque shoulder are well-documented vulnerable sites. The inherent weakness of the FC material at the thinnest point increases the stress, making it vulnerable, and it is the big curvature of the lumen contour over FC which may result in increased plaque stress. We aimed to assess critical stresses at FC(MIN) and the maximum lumen curvature over FC (LC(MAX)) and quantify the difference to see which vulnerable site had the highest critical stress and was, therefore, at highest risk of rupture. One hundred patients underwent high resolution carotid magnetic resonance (MR) imaging. We used 352 MR slices with delineated atherosclerotic components for the simulation study. Stresses at all the integral nodes along the lumen surface were calculated using the finite-element method. FC(MIN) and LC(MAX) were identified, and critical stresses at these sites were assessed and compared. Critical stress at FC(MIN) was significantly lower than that at LC(MAX) (median: 121.55 kPa; inter quartile range (IQR) = [60.70-180.32] kPa vs. 150.80 kPa; IQR = [91.39-235.75] kPa, p < 0.0001). If critical stress at FC(MIN) was only used, then the stress condition of 238 of 352 MR slices would be underestimated, while if the critical stress at LC(MAX) only was used, then 112 out of 352 would be underestimated. Stress analysis at FC(MIN) and LC(MAX) should be used for a refined mechanical risk assessment of atherosclerotic plaques, since material failure at either site may result in rupture.

journal_name

Ann Biomed Eng

authors

Teng Z,Sadat U,Li Z,Huang X,Zhu C,Young VE,Graves MJ,Gillard JH

doi

10.1007/s10439-010-0078-3

subject

Has Abstract

pub_date

2010-10-01 00:00:00

pages

3096-101

issue

10

eissn

0090-6964

issn

1573-9686

journal_volume

38

pub_type

杂志文章
  • Simulation of neutrophil deformation and transport in capillaries using newtonian and viscoelastic drop models.

    abstract::It is well known that neutrophils take much longer to traverse the pulmonary capillary bed than erythrocytes, and this is likely due to differences in the structure and rheology of the cells. In this study, we simulate the transit of a neutrophil in a capillary using a Newtonian drop model and a viscoelastic drop mode...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-007-9286-x

    authors: Zhou C,Yue P,Feng JJ

    更新日期:2007-05-01 00:00:00

  • Phenotype modulation in vascular tissue engineering using biochemical and mechanical stimulation.

    abstract::Biochemical stimulation was applied in combination with cyclic mechanical strain to engineered vascular constructs made of isolated smooth muscle cells in a three-dimensional (3D) collagen type 1 matrix. Platelet-derived growth factor (PDGF) and transforming growth factor beta (TGF-beta) were added exogenously to the ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1558031

    authors: Stegemann JP,Nerem RM

    更新日期:2003-04-01 00:00:00

  • Phonocardiographic signal analysis method using a modified hidden Markov model.

    abstract::Auscultation is an important diagnostic indicator for cardiovascular analysis. Heart sound classification and analysis play an important role in the auscultative diagnosis. This study uses a combination of Mel-frequency cepstral coefficient (MFCC) and hidden Markov model (HMM) to efficiently extract the features for p...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-006-9232-3

    authors: Wang P,Lim CS,Chauhan S,Foo JY,Anantharaman V

    更新日期:2007-03-01 00:00:00

  • 3D Printed Vascular Networks Enhance Viability in High-Volume Perfusion Bioreactor.

    abstract::There is a significant clinical need for engineered bone graft substitutes that can quickly, effectively, and safely repair large segmental bone defects. One emerging field of interest involves the growth of engineered bone tissue in vitro within bioreactors, the most promising of which are perfusion bioreactors. Usin...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-016-1662-y

    authors: Ball O,Nguyen BB,Placone JK,Fisher JP

    更新日期:2016-12-01 00:00:00

  • Constitutive modeling of rate-dependent stress-strain behavior of human liver in blunt impact loading.

    abstract::An understanding of the mechanical deformation behavior of the liver under high strain rate loading conditions could aid in the development of vehicle safety measures to reduce the occurrence of blunt liver injury. The purpose of this study was to develop a constitutive model of the stress-strain behavior of the human...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-008-9555-3

    authors: Sparks JL,Dupaix RB

    更新日期:2008-11-01 00:00:00

  • An Engineered Biomimetic MPER Peptide Vaccine Induces Weakly HIV Neutralizing Antibodies in Mice.

    abstract::A vaccine that induces broadly neutralizing antibodies (bnAbs) against the human immunodeficiency virus (HIV) would be instrumental in controlling the disease. The membrane proximal external region (MPER) peptide is an appealing antigen candidate since it is conserved and is the target of several human bnAbs, such as ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-019-02398-8

    authors: Shao S,Huang WC,Lin C,Hicar MD,LaBranche CC,Montefiori DC,Lovell JF

    更新日期:2020-07-01 00:00:00

  • Estrogen Preserves Pulsatile Pulmonary Arterial Hemodynamics in Pulmonary Arterial Hypertension.

    abstract::Pulmonary arterial hypertension (PAH) is caused by extensive pulmonary vascular remodeling that increases right ventricular (RV) afterload and leads to RV failure. PAH predominantly affects women; paradoxically, female PAH patients have better outcomes than men. The roles of estrogen in PAH remain controversial, which...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-016-1716-1

    authors: Liu A,Hacker T,Eickhoff JC,Chesler NC

    更新日期:2017-03-01 00:00:00

  • Degradation, bioactivity, and osteogenic potential of composites made of PLGA and two different sol-gel bioactive glasses.

    abstract::We have developed poly(L: -lactide-co-glycolide) (PLGA) based composites using sol-gel derived bioactive glasses (S-BG), previously described by our group, as composite components. Two different composite types were manufactured that contained either S2-high content silica S-BG, or A2-high content lime S-BG. The compo...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-011-0307-4

    authors: Pamula E,Kokoszka J,Cholewa-Kowalska K,Laczka M,Kantor L,Niedzwiedzki L,Reilly GC,Filipowska J,Madej W,Kolodziejczyk M,Tylko G,Osyczka AM

    更新日期:2011-08-01 00:00:00

  • Mechanics of a thin walled collapsible microtube.

    abstract::The purpose of this study is to measure the transmural pressure-cross sectional area relation of micro tubes (240 microns diameter) and to compare the measured perfusion pressure-flow relation with the pressure-flow relation calculated from the experimental pressure-cross sectional area relation. The microtubes are ma...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02368042

    authors: Sipkema P,Westerhof N

    更新日期:1989-01-01 00:00:00

  • Conductance method for the measurement of cross-sectional areas of the aorta.

    abstract::A modified conductance method to determine the cross-sectional areas (CSAs) of arteries in piglets was evaluated in vivo. The method utilized a conductance catheter having four electrodes. Between the outer electrodes an alternating current was applied and between the inner electrodes the induced voltage difference wa...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.219

    authors: Kornet L,Jansen JR,Gussenhoven EJ,Hardeman MR,Hoeks AP,Versprille A

    更新日期:1999-03-01 00:00:00

  • Tissue remodeling of rat pulmonary artery in hypoxic breathing. II. Course of change of mechanical properties.

    abstract::When cells and the matrix of a tissue remodel, the mechanical properties of the tissue do change. The mechanical properties are expressed by constitutive equations. In this article the remodeling of the constitutive equation of the pulmonary artery is studied. The remodeling was induced in a rat breathing a gas whose ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1380417

    authors: Huang W,Delgado-West D,Wu JT,Fung YC

    更新日期:2001-01-01 00:00:00

  • Cerebrovascular transmural pressure and autoregulation.

    abstract::The cerebral blood flow (CBF) response to changes in perfusion pressure mediated through decreases in arterial pressure, increases in cerebrospinal fluid (CSF) pressure and increases in jugular venous pressure was studied in anesthetized dogs. A preparation was developed in which each of the three relevant pressures c...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02584249

    authors: Wagner EM,Traystman RJ

    更新日期:1985-01-01 00:00:00

  • Breathing resistance and ultrafine particle deposition in nasal-laryngeal airways of a newborn, an infant, a child, and an adult.

    abstract::As a human grows from birth to adulthood, both airway anatomy and breathing conditions vary, altering the deposition rate and pattern of inhaled aerosols. However, deposition studies have typically focused on adult subjects, results of which may not be readily extrapolated to children. This study numerically evaluated...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-012-0603-7

    authors: Xi J,Berlinski A,Zhou Y,Greenberg B,Ou X

    更新日期:2012-12-01 00:00:00

  • Intelligent multichannel stimulator for the study of cardiac arrhythmias.

    abstract::An intelligent multichannel stimulator (IMS) has been designed and built for use in a cardiac research environment. The device is capable of measuring and responding to cardiac electrophysiological phenomena in real time with carefully timed and placed electrical stimuli. The system consists of 16 channels of sense/st...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1451077

    authors: Johnson PL,Newton JC,Rollins DL,Knisley SB,Ideker RE,Smith WM

    更新日期:2002-02-01 00:00:00

  • A new pulsatile flow visualization method using a photochromic dye with application to Doppler ultrasound.

    abstract::A nonintrusive method for the visualization of pulsatile flow velocity profiles is described. The method is based on the use of a photochromic dye that is added to the fluid being studied and a nitrogen laser which excites the dye producing a marker "line" whose movement can be photographed. A microcomputer is used as...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02584271

    authors: Poots K,Cobbold RS,Johnston KW,Appugliese R,Kassam M,Zuech PE,Hummel RL

    更新日期:1986-01-01 00:00:00

  • Accuracy of Functional and Predictive Methods to Calculate the Hip Joint Center in Young Non-pathologic Asymptomatic Adults with Dual Fluoroscopy as a Reference Standard.

    abstract::Predictions from biomechanical models of gait may be sensitive to joint center locations. Most often, the hip joint center (HJC) is derived from locations of reflective markers adhered to the skin. Here, predictive techniques use regression equations of pelvic anatomy to estimate the HJC, whereas functional methods tr...

    journal_title:Annals of biomedical engineering

    pub_type: 临床试验,杂志文章

    doi:10.1007/s10439-015-1522-1

    authors: Fiorentino NM,Kutschke MJ,Atkins PR,Foreman KB,Kapron AL,Anderson AE

    更新日期:2016-07-01 00:00:00

  • Transport Analysis of Engineered Liver Tissue Fabricated Using a Capsule-Based, Modular Approach.

    abstract::The bioinspired, microscale tissue engineering approach has emerged in recent years as a promising alternative to preformed scaffolds. Using this approach, complex tissues and organs can be efficiently engineered from microscale modules to replicate the intricate architecture and physiology of vascularized organs and ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-018-02192-y

    authors: Annamalai RT,Matthew HWT

    更新日期:2019-05-01 00:00:00

  • Integrated microfluidics platforms for investigating injury and regeneration of CNS axons.

    abstract::We describe the development of experimental platforms to quantify the regeneration of injured central nervous system (CNS) neurons by combining engineering technologies and primary neuronal cultures. Although the regeneration of CNS neurons is an important area of research, there are no currently available methods to ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/s10439-012-0515-6

    authors: Kim HJ,Park JW,Byun JH,Vahidi B,Rhee SW,Jeon NL

    更新日期:2012-06-01 00:00:00

  • Binary segmentation masks can improve intrasubject registration accuracy of bone structures in CT images.

    abstract::Registration of bone structures is a common problem in medical research as well as in clinical applications. Intrasubject rigid 3D monomodality registration of segmented bone structures of CT images and multimodality registration of muMR and segmented muCT bone images were performed with the multiresolution intensity-...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-9981-x

    authors: Museyko O,Eisa F,Hess A,Schett G,Kalender WA,Engelke K

    更新日期:2010-07-01 00:00:00

  • A preliminary physiologically based pharmacokinetic model for naphthalene and naphthalene oxide in mice and rats.

    abstract::Naphthalene is a toxicant with unusual species and tissue specificity that has been the subject of in vitro studies. We describe a preliminary physiologically based pharmacokinetic (PBPK) model for naphthalene constructed solely from in vitro data for comparison to animal data without the use of adjustable parameters....

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02667357

    authors: Sweeney LM,Shuler ML,Quick DJ,Babish JG

    更新日期:1996-03-01 00:00:00

  • Analytical Modelling of Natural Frequency of Tympanic Membrane as the Low-Frequency Limit of Hearing.

    abstract::We examine the low-frequency limit of hearing of the mammalian ear through the analytical modelling of the natural frequency of the tympanic membrane. The resulting equation of the natural frequency of the modelled tympanic membrane is numerically verified against previous theoretical studies, and is statistically val...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-019-02356-4

    authors: Jabaraj DJ

    更新日期:2020-01-01 00:00:00

  • Bioengineering the skin-implant interface: the use of regenerative therapies in implanted devices.

    abstract::This discussion and review article focuses on the possible use of regenerative techniques applied to the interfaces between skin and medical implants. As is widely known, the area of contact between an implant and the skin--the skin-implant interface--is prone to recurrent and persistent problems originated from the l...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/s10439-010-9937-1

    authors: Peramo A,Marcelo CL

    更新日期:2010-06-01 00:00:00

  • The transport profile of cytokines in epidermal equivalents subjected to mechanical loading.

    abstract::Pressure ulcer risk assessment might be optimized by incorporating the soft tissue reaction to mechanical loading in the currently used risk assessment scales. Cytokines, like IL-1alpha, IL-1RA, IL-8, and TNF-alpha, might be used to determine this tissue reaction, since they are released after 24 h of mechanical loadi...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-009-9652-y

    authors: Cornelissen LH,Bronneberg D,Bader DL,Baaijens FP,Oomens CW

    更新日期:2009-05-01 00:00:00

  • Contraction induced muscle injury: towards personalized training and recovery programs.

    abstract::Skeletal muscles can be injured by their own contractions. Such contraction-induced injury, often accompanied by delayed onset of muscle soreness, is a leading cause of the loss of mobility in the rapidly increasing population of elderly people. Unlike other types of muscle injuries which hurt almost exclusively those...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/s10439-014-1173-7

    authors: Givli S

    更新日期:2015-02-01 00:00:00

  • On the Impact of Intraluminal Thrombus Mechanical Behavior in AAA Passive Mechanics.

    abstract::Intraluminal thrombus (ILT) is a pseudo-tissue that develops from coagulated blood, and is found in most abdominal aortic aneurysms (AAAs) of clinically relevant size. A number of studies have suggested that ILT mechanical characteristics may be related to AAA risk of rupture, even though there is still great controve...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1267-x

    authors: Riveros F,Martufi G,Gasser TC,Rodriguez-Matas JF

    更新日期:2015-09-01 00:00:00

  • Low Impedance Carbon Adhesive Electrodes with Long Shelf Life.

    abstract::A novel electrocardiogram (ECG) electrode film is developed by mixing carbon black powder and a quaternary salt with a visco-elastic polymeric adhesive. Unlike traditional wet gel-based electrodes, carbon/salt/adhesive (CSA) electrodes should theoretically have an infinite shelf life as they do not dehydrate even afte...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1282-y

    authors: Posada-Quintero HF,Reyes BA,Burnham K,Pennace J,Chon KH

    更新日期:2015-10-01 00:00:00

  • Holographic interferometry: a critique of the technique and its potential for biomedical measurements.

    abstract::Double-exposure holographic interferometry is a contactless whole-field method. Dimensional changes are visualized as a series of interference fringes overlaid on the holographic image of the femur, where each fringe represents 0.316 micron (half the wavelength of the laser light) of motion. Interferograms for intact ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02364168

    authors: Ovryn B,Manley MT,Stern LS

    更新日期:1987-01-01 00:00:00

  • Mitral Valve Regurgitation with a Rotary Left Ventricular Assist Device: The Haemodynamic Effect of Inlet Cannulation Site and Speed Modulation.

    abstract::Mitral valve regurgitation (MVR) is common in patients receiving left ventricular assist device (LVAD) support, however the haemodynamic effect of MVR is not entirely clear. This study evaluated the haemodynamic effect of MVR with LVAD support and the influence of inflow cannulation site and LVAD speed modulation. Lef...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-016-1579-5

    authors: Gregory SD,Stevens MC,Wu EL,Pauls JP,Kleinheyer M,Fraser JF

    更新日期:2016-09-01 00:00:00

  • Chondrogenesis and integration of mesenchymal stem cells within an in vitro cartilage defect repair model.

    abstract::Integration of repair tissue is a key indicator of the long-term success of cell-based therapies for cartilage repair. The objective of this study was to compare the in vitro chondrogenic differentiation and integration of agarose hydrogels seeded with either chondrocytes or bone marrow-derived mesenchymal stem cells ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-009-9791-1

    authors: Vinardell T,Thorpe SD,Buckley CT,Kelly DJ

    更新日期:2009-12-01 00:00:00

  • Mechanisms of interstitial flow-induced remodeling of fibroblast-collagen cultures.

    abstract::Interstitial fluid flow, critical for macromolecular transport, was recently shown to drive fibroblast differentiation and perpendicular cell and matrix alignment in 3D collagen cultures. Here we explore the mechanisms underlying this flow-induced cell and collagen alignment. Cell and matrix alignment was assessed fro...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-005-9067-3

    authors: Ng CP,Swartz MA

    更新日期:2006-03-01 00:00:00