Chest Wall Kinematics Using Triangular Cosserat Point Elements in Healthy and Neuromuscular Subjects.

Abstract:

:Optoelectronic plethysmography (OEP) is a noninvasive method for assessing lung volume variations and the contributions of different anatomical compartments of the chest wall (CW) through measurements of the motion of markers attached to the CW surface. The present study proposes a new method for analyzing the local CW kinematics from OEP measurements based on the kinematics of triangular Cosserat point elements (TCPEs). 52 reflective markers were placed on the anterior CW to create a mesh of 78 triangles according to an anatomical model. Each triangle was characterized by a TCPE and its kinematics was described using four time-variant scalar TCPE parameters. The total CW volume ([Formula: see text]) and the contributions of its six compartments were also estimated, using the same markers. The method was evaluated using measurements of ten healthy subjects, nine patients with Pompe disease, and ten patients with Duchenne muscular dystrophy (DMD), during spontaneous breathing (SB) and vital capacity maneuvers (VC) in the supine position. TCPE parameters and compartmental volumes were compared with [Formula: see text] by computing the phase angles [Formula: see text] (for SB) and the correlation r (for VC) between them. Analysis of [Formula: see text] and r of the outward translation parameter [Formula: see text] of each TCPE revealed that for healthy subjects it provided similar results to those obtained by compartmental volumes, whereas for the neuromuscular patients the TCPE method was capable of detecting local asynchronous and paradoxical movements also in cases where they were undistinguished by volumes. Therefore, the TCPE approach provides additional information to OEP that may enhance its clinical evaluation capabilities.

journal_name

Ann Biomed Eng

authors

Solav D,Meric H,Rubin MB,Pradon D,Lofaso F,Wolf A

doi

10.1007/s10439-017-1840-6

subject

Has Abstract

pub_date

2017-08-01 00:00:00

pages

1963-1973

issue

8

eissn

0090-6964

issn

1573-9686

pii

10.1007/s10439-017-1840-6

journal_volume

45

pub_type

杂志文章
  • A long-memory model of motor learning in the saccadic system: a regime-switching approach.

    abstract::Maintenance of movement accuracy relies on motor learning, by which prior errors guide future behavior. One aspect of this learning process involves the accurate generation of predictions of movement outcome. These predictions can, for example, drive anticipatory movements during a predictive-saccade task. Predictive ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-012-0669-2

    authors: Wong AL,Shelhamer M

    更新日期:2013-08-01 00:00:00

  • Selective stimulation of latissimus dorsi muscle for cardiac assist.

    abstract::The contractile power of the latissimus dorsi muscle (LDM) is used in skeletal muscle cardiac assist (SMCA) to augment the blood pumping ability of a failing heart. The LDM has three anatomically distinct, independently innervate segments-the transverse, oblique, and lateral. There are potential advantages to selectiv...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.164

    authors: Thompson DR,Michele JJ,Cheever EA,George DT

    更新日期:1999-01-01 00:00:00

  • Cue-Signal-Response Analysis in 3D Chondrocyte Scaffolds with Anabolic Stimuli.

    abstract::Articular cartilage is an avascular connective tissue responsible for bearing loads. Cell signaling plays a central role in cartilage homeostasis and tissue engineering by directing chondrocytes to synthesize/degrade the extracellular matrix or promote inflammatory responses. The aim of this paper was to investigate a...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-017-1964-8

    authors: Neidlin M,Korcari A,Macheras G,Alexopoulos LG

    更新日期:2018-02-01 00:00:00

  • A numerical implementation to predict residual strains from the homogeneous stress hypothesis with application to abdominal aortic aneurysms.

    abstract::Wall stress analysis of abdominal aortic aneurysm (AAA) is a promising method of identifying AAAs at high risk of rupture. However, neglecting residual strains (RS) in the load-free configuration of patient-specific finite element analysis models is a sever limitation that strongly affects the computed wall stresses. ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-013-0749-y

    authors: Polzer S,Bursa J,Gasser TC,Staffa R,Vlachovsky R

    更新日期:2013-07-01 00:00:00

  • Stochasticity in membrane-localized "ligand-receptor-G protein" binding: consequences for leukocyte movement behavior.

    abstract::The signal that governs the chemotactic response of mammalian white blood cells and tissue cells arises from membrane-localized binding events involving chemotactic factor ligands and receptors and G proteins. Fluctuations in this signal have been traditionally attributed to significant "noise" in receptor-ligand bind...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02584427

    authors: Moghe PV,Tranquillo RT

    更新日期:1995-05-01 00:00:00

  • Developing a quantitative measurement system for assessing heterotopic ossification and monitoring the bioelectric metrics from electrically induced osseointegration in the residual limb of service members.

    abstract::Poor prosthetic fit is often the result of heterotopic ossification (HO), a frequent problem following blast injuries for returning service members. Osseointegration technology offers an advantage for individuals with significant HO and poor socket tolerance by using direct skeletal attachment of a prosthesis to the d...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-0050-2

    authors: Isaacson BM,Stinstra JG,MacLeod RS,Pasquina PF,Bloebaum RD

    更新日期:2010-09-01 00:00:00

  • Why, When, Who, What, How, and Where for Trainees Writing Literature Review Articles.

    abstract::Literature review articles provide a valuable mechanism for remaining informed amidst an ever-increasing body of scientific work. Condensing current advances into this disseminatable form is a critical activity for any research trainee. To systematize this multifaceted process, we present the "why, when, who, what, ho...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-019-02290-5

    authors: Koons GL,Schenke-Layland K,Mikos AG

    更新日期:2019-11-01 00:00:00

  • Phospholipids identified on the pericardium and their ability to impart boundary lubrication.

    abstract::Phospholipids have been identified by thin-layer chromatography in appreciable quantities in pericardial fluid taken from 12 dogs and found to include sphingomyelin and phosphatidylcholines, -ethanolamines, -inositols and -serines--the cholines predominating. The extracts, the synthetic surfactants and a mixture of sy...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02584258

    authors: Hills BA,Butler BD

    更新日期:1985-01-01 00:00:00

  • A Conceivable Mechanism Responsible for the Synergy of High and Low Voltage Irreversible Electroporation Pulses.

    abstract::Irreversible electroporation (IRE), is a new non-thermal tissue ablation technology in which brief high electric field pulses are delivered across the target tissue to induce cell death by irreversible permeabilization of the cell membrane. A deficiency of conventional IRE is that the ablation zone is relatively small...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-019-02258-5

    authors: Lv Y,Yao C,Rubinsky B

    更新日期:2019-07-01 00:00:00

  • The air-conditioning capacity of the human nose.

    abstract::The nose is the front line defender of the respiratory system. Unsteady simulations in three-dimensional models have been developed to study transport patterns in the human nose and its overall air-conditioning capacity. The results suggested that the healthy nose can efficiently provide about 90% of the heat and the ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-005-2513-4

    authors: Naftali S,Rosenfeld M,Wolf M,Elad D

    更新日期:2005-04-01 00:00:00

  • Tensile strain as a regulator of mesenchymal stem cell osteogenesis.

    abstract::A role for mechanical stimulation in the control of cell fate has been proposed and mechanical conditioning of mesenchymal stem cells (MSCs) is of interest in directing MSC behavior for tissue engineering applications. This study investigates strain-induced differentiation and proliferation of MSCs, and investigates t...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-9979-4

    authors: Kearney EM,Farrell E,Prendergast PJ,Campbell VA

    更新日期:2010-05-01 00:00:00

  • Distribution of internal strains around bony prominences in pigs.

    abstract::Deep tissue injury (DTI) is a type of pressure ulcer in which tissue breakdown initiates at the bone-muscle interface under intact skin. Excessive deformation in the soft tissue, particularly around bony prominences, is believed to be one of the causes leading to the development of DTI. The main goal of this study was...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-012-0539-y

    authors: Solis LR,Liggins AB,Seres P,Uwiera RR,Poppe NR,Pehowich E,Thompson RB,Mushahwar VK

    更新日期:2012-08-01 00:00:00

  • Sharing best practices in teaching biomedical engineering design.

    abstract::In an effort to share best practices in undergraduate engineering design education, we describe the origin, evolution and the current status of the undergraduate biomedical engineering design team program at Johns Hopkins University. Specifically, we describe the program and judge the quality of the pedagogy by relati...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-013-0781-y

    authors: Allen RH,Acharya S,Jancuk C,Shoukas AA

    更新日期:2013-09-01 00:00:00

  • Simultaneous regulation of hemodynamic and anesthetic states: a simulation study.

    abstract::A model predictive control strategy to simultaneously regulate hemodynamic and anesthetic variables in critical care patients is presented. A nonlinear canine circulatory model, which has been used to study the effect of inotropic and vasoactive drugs on hemodynamic variables, has been extended to include propofol pha...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.255

    authors: Rao RR,Bequette BW,Roy RJ

    更新日期:2000-01-01 00:00:00

  • Do increased electrogastrographic frequencies always correspond to internal tachygastria?

    abstract::This study was undertaken to investigate the possible origin of some cutaneously recorded higher frequency electrogastrographic signals. Computer modeling of gastric electrical uncoupling was performed using previously described conoidal dipole model. Cutaneous electrogastrograms were simulated after uncoupling was in...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:

    authors: Mintchev MP,Bowes KL

    更新日期:1997-11-01 00:00:00

  • Detergent-Based Decellularization of Bovine Carotid Arteries for Vascular Tissue Engineering.

    abstract::Vascular diseases are an increasing health issue, and common alloplastic, allogenic or autologous vascular grafts show frequent complications. The aim of this study is to develop an acellular, xenogenic bypass-graft from a bovine carotid artery (BAC) using detergent-based protocols. We compared decellularization with ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-017-1892-7

    authors: Daugs A,Hutzler B,Meinke M,Schmitz C,Lehmann N,Markhoff A,Bloch O

    更新日期:2017-11-01 00:00:00

  • Pixel-Based DXA-Derived Structural Properties Strongly Correlate with pQCT Measures at the One-Third Distal Femur Site.

    abstract::While bone mineral density has been traditionally used to quantify fracture risk for individuals with spinal cord injuries, recent studies are including engineering measurements such as section modulus and cross sectional moment of inertia. These are almost exclusively calculated by peripheral QCT scanners which, unli...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-017-1796-6

    authors: Baker AM,Wagner DW,Kiratli BJ,Beaupre GS

    更新日期:2017-05-01 00:00:00

  • The effect of visual and sensory performance on head impact biomechanics in college football players.

    abstract::The development of prevention strategies is critical to address the rising prevalence of sport-related concussions. Visual and sensory performance may influence an individual's ability to interpret environmental cues, anticipate opponents' actions, and create appropriate motor responses limiting the severity of an imp...

    journal_title:Annals of biomedical engineering

    pub_type: 临床试验,杂志文章

    doi:10.1007/s10439-013-0881-8

    authors: Harpham JA,Mihalik JP,Littleton AC,Frank BS,Guskiewicz KM

    更新日期:2014-01-01 00:00:00

  • Error mechanisms of the oscillometric fixed-ratio blood pressure measurement method.

    abstract::The oscillometric fixed-ratio method is widely employed for non-invasive measurement of systolic and diastolic pressures (SP and DP) but is heuristic and prone to error. We investigated the accuracy of this method using an established mathematical model of oscillometry. First, to determine which factors materially aff...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-012-0700-7

    authors: Liu J,Hahn JO,Mukkamala R

    更新日期:2013-03-01 00:00:00

  • Reinforcement of Mono- and Bi-layer Poly(Ethylene Glycol) Hydrogels with a Fibrous Collagen Scaffold.

    abstract::Biomaterial-based tissue engineering strategies hold great promise for osteochondral tissue repair. Yet significant challenges remain in joining highly dissimilar materials to achieve a biomimetic, mechanically robust design for repairing interfaces between soft tissue and bone. This study sought to improve interfacia...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1337-0

    authors: Kinneberg KR,Nelson A,Stender ME,Aziz AH,Mozdzen LC,Harley BA,Bryant SJ,Ferguson VL

    更新日期:2015-11-01 00:00:00

  • Cellularized microcarriers as adhesive building blocks for fabrication of tubular tissue constructs.

    abstract::To meet demands of vascular reconstruction, there is a need for prosthetic alternatives to natural blood vessels. Here we explored a new conduit fabrication approach. Macroporous, gelatin microcarriers laden with human umbilical vein endothelial cells and aortic smooth muscle cells were dispensed into tubular agarose ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-013-0883-6

    authors: Twal WO,Klatt SC,Harikrishnan K,Gerges E,Cooley MA,Trusk TC,Zhou B,Gabr MG,Shazly T,Lessner SM,Markwald RR,Argraves WS

    更新日期:2014-07-01 00:00:00

  • The current status and future directions of impedance cardiography in ICU.

    abstract::Impedance cardiography has not achieved popularity in the Intensive Care Unit (ICU) to date probably because of the limitations in technique and interpretation associated with the altered physiology of critically ill patients, and also because of interference from other machinery in the ICU. The current climate of que...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02368068

    authors: Fuller H,Raskob G,ter Keurs H,Hull R

    更新日期:1989-01-01 00:00:00

  • Human lumbar spine creep during cyclic and static flexion: creep rate, biomechanics, and facet joint capsule strain.

    abstract::There is a high incidence of low back pain (LBP) associated with occupations requiring sustained and/or repetitive lumbar flexion (SLF and RLF, respectively), which cause creep of the viscoelastic tissues. The purpose of this study was to determine the effect of creep on lumbar biomechanics and facet joint capsule (FJ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-005-1742-x

    authors: Little JS,Khalsa PS

    更新日期:2005-03-01 00:00:00

  • Partial Bone Formation in Additive Manufactured Porous Implants Reduces Predicted Stress and Danger of Fatigue Failure.

    abstract::New porous implant designs made possible by additive manufacturing allow for increased osseointegration, potentially improving implant performance and longevity for patients that require massive bone implants. The aim of this study was to evaluate how implantation and the strain distribution in the implant affect the ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-019-02369-z

    authors: Cheong VS,Fromme P,Coathup MJ,Mumith A,Blunn GW

    更新日期:2020-01-01 00:00:00

  • Fractal character of pulmonary microvascular permeability.

    abstract::The pulmonary microvasculature offers a heterogeneous barrier to the motion of large solutes as they pass between blood and lymph. While this barrier has been approximated by a few discrete pathways or by statistical ensembles of many pathways, these descriptions only partly capture the structural and functional prope...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02368425

    authors: McNamee JE

    更新日期:1990-01-01 00:00:00

  • The tendon injury response is influenced by decorin and biglycan.

    abstract::Defining the constituent regulatory molecules in tendon is critical to understanding the process of tendon repair and instructive to the development of novel treatment modalities. The purpose of this study is to define the structural, expressional, and mechanical changes in the tendon injury response, and elucidate th...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-013-0915-2

    authors: Dunkman AA,Buckley MR,Mienaltowski MJ,Adams SM,Thomas SJ,Satchell L,Kumar A,Pathmanathan L,Beason DP,Iozzo RV,Birk DE,Soslowsky LJ

    更新日期:2014-03-01 00:00:00

  • A physical model describing the mechanism for formation of gas microbubbles in patients with mitral mechanical heart valves.

    abstract::This study was aimed at developing a physical model, supported by experimental observations, to describe the formation and growth of microbubbles seen in patients with mitral mechanical heart valves (MHV). This phenomenon, often referred to as high intensity transient signals (HITS), appears as bright, intense, high-v...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.231

    authors: Rambod E,Beizaie M,Shusser M,Milo S,Gharib M

    更新日期:1999-11-01 00:00:00

  • Mechanical analysis of atherosclerotic plaques based on optical coherence tomography.

    abstract::Finite element analysis is a powerful tool for investigating the biomechanics of atherosclerosis and has thereby provided an improved understanding of acute myocardial infarction. Structural analysis of arterial walls is traditionally performed using geometry contours derived from histology. In this paper we demonstra...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/b:abme.0000049034.75368.4a

    authors: Chau AH,Chan RC,Shishkov M,MacNeill B,Iftimia N,Tearney GJ,Kamm RD,Bouma BE,Kaazempur-Mofrad MR

    更新日期:2004-11-01 00:00:00

  • Development of gradient descent adaptive algorithms to remove common mode artifact for improvement of cardiovascular signal quality.

    abstract:BACKGROUND:Common-mode noise degrades cardiovascular signal quality and diminishes measurement accuracy. Filtering to remove noise components in the frequency domain often distorts the signal. METHOD:Two adaptive noise canceling (ANC) algorithms were tested to adjust weighted reference signals for optimal subtraction ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-007-9294-x

    authors: Ciaccio EJ,Micheli-Tzanakou E

    更新日期:2007-07-01 00:00:00

  • Development of a device for measuring adherence of skin grafts to the wound surface.

    abstract::Adherence of a biological graft to the wound surface is the most important factor influencing the ultimate success of graft viability. A machine has been developed to test the adherence of biological graft materials to a substrate such as a wound surface. The peeling mode, which yields reproducible quantitative measur...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02368164

    authors: Dong C,Mead E,Skalak R,Fung YC,Debes JC,Zapata-Sirvent RL,Andree C,Greenleaf G,Cooper M,Hansbrough JF

    更新日期:1993-01-01 00:00:00