Permeability of endothelial and astrocyte cocultures: in vitro blood-brain barrier models for drug delivery studies.

Abstract:

:The blood-brain barrier (BBB) is a major obstacle for drug delivery to the brain. To seek for in vitro BBB models that are more accessible than animals for investigating drug transport across the BBB, we compared four in vitro cultured cell models: endothelial monoculture (bEnd3 cell line), coculture of bEnd3 and primary rat astrocytes (coculture), coculture with collagen type I and IV mixture, and coculture with Matrigel. The expression of the BBB tight junction proteins in these in vitro models was assessed using RT-PCR and immunofluorescence. We also quantified the hydraulic conductivity (L (p)), transendothelial electrical resistance (TER) and diffusive solute permeability (P) of these models to three solutes: TAMRA, Dextran 10K and Dextran 70K. Our results show that L (p) and P of the endothelial monoculture and coculture models are not different from each other. Compared with in vivo permeability data from rat pial microvessels, P of the endothelial monoculture and coculture models are not significantly different from in vivo data for Dextran 70K, but they are 2-4 times higher for TAMRA and Dextran 10K. This suggests that the endothelial monoculture and all of the coculture models are fairly good models for studying the transport of relatively large solutes across the BBB.

journal_name

Ann Biomed Eng

authors

Li G,Simon MJ,Cancel LM,Shi ZD,Ji X,Tarbell JM,Morrison B 3rd,Fu BM

doi

10.1007/s10439-010-0023-5

subject

Has Abstract

pub_date

2010-08-01 00:00:00

pages

2499-511

issue

8

eissn

0090-6964

issn

1573-9686

journal_volume

38

pub_type

杂志文章
  • Effects of crowding on the thermal stability of heterogeneous protein solutions.

    abstract::Crowding can substantially affect the transition of a protein between its native (N) and unfolded (U) states via volume exclusion effects. Also, it influences considerably the aggregation (A) of unfolded proteins. To examine the details, we developed an approach for computing the kinetic rates of the process N <--> U ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-005-5780-8

    authors: Despa F,Orgill DP,Lee RC

    更新日期:2005-08-01 00:00:00

  • Insulin minimal model indexes and secretion: proper handling of uncertainty by a Bayesian approach.

    abstract::The identification of the insulin minimal model (MM) for the estimation of insulin secretion rate (ISR) and physiological indexes (e.g. beta-cell sensitivity) requires the knowledge of C-peptide (CP) kinetics. The four parameters of the two-compartment model of CP kinetics in a given individual can be derived either f...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1023/b:abme.0000032465.75888.91

    authors: Magni P,Sparacino G,Bellazzi R,Toffolo GM,Cobelli C

    更新日期:2004-07-01 00:00:00

  • Sensor Anchoring Improves the Correlation Between Intramuscular Pressure and Muscle Tension in a Rabbit Model.

    abstract::Intramuscular pressure (IMP) shows promise for estimating individual muscle tension in vivo. However, previous pressure measurements show high variability during isometric contraction and poor correlation with tension during dynamic contraction. We hypothesized that enhanced sensor anchoring/orientation would improve ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02633-7

    authors: O'Connor SM,Kaufman KR,Ward SR,Lieber RL

    更新日期:2021-02-01 00:00:00

  • Intrinsic oscillations and discharge regularity of units in the dorsal cochlear nucleus (DCN) of the barbiturate anesthetized gerbil.

    abstract::Spike discharge patterns showing intrinsic oscillations (IOs) have been reported in units in the dorsal cochlear nucleus (DCN) of the decerebrate cat. These oscillations are related to the regularity of a unit's discharge rate and may be important for pitch perception. A DCN unit's regularity can be affected by severa...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.96

    authors: Gdowski GT,Voigt HF

    更新日期:1998-05-01 00:00:00

  • L-selectin shear thresholding modulates leukocyte secondary capture.

    abstract::Transient homotypic adhesions between flowing leukocytes and those previously adherent on the vessel wall has been proposed to amplify the accumulation of leukocytes at sites of inflammation. While adhesion of leukocytes to the vessel wall (primary capture) is mediated primarily by P-selectin on the endothelium and P-...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-008-9468-1

    authors: Paschall CD,Lawrence MB

    更新日期:2008-04-01 00:00:00

  • Thermal analysis of the bone surface induced by laser radiation.

    abstract::High energy laser has emerged to be an important surgical tool in medical technology. However, the application of laser energy to drill or cut a bone is still in an experimental state. In order to estimate the adequacy of laser heating of bone surface and at the same time minimize the damage to the bone tissue, we dev...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02363565

    authors: Chen II,Saha S

    更新日期:1987-01-01 00:00:00

  • Effects of Chemically Doped Bioactive Borate Glass on Neuron Regrowth and Regeneration.

    abstract::Peripheral nerve injuries present challenges to regeneration. Currently, the gold standard for nerve repair is an autograft that results in another region of the body suffering nerve damage. Previously, bioactive borate glass (BBG) has been studied in clinical trials to treat patients with non-healing wounds, and we h...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-016-1689-0

    authors: Gupta B,Papke JB,Mohammadkhah A,Day DE,Harkins AB

    更新日期:2016-12-01 00:00:00

  • An Engineered Biomimetic MPER Peptide Vaccine Induces Weakly HIV Neutralizing Antibodies in Mice.

    abstract::A vaccine that induces broadly neutralizing antibodies (bnAbs) against the human immunodeficiency virus (HIV) would be instrumental in controlling the disease. The membrane proximal external region (MPER) peptide is an appealing antigen candidate since it is conserved and is the target of several human bnAbs, such as ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-019-02398-8

    authors: Shao S,Huang WC,Lin C,Hicar MD,LaBranche CC,Montefiori DC,Lovell JF

    更新日期:2020-07-01 00:00:00

  • Antithrombotic Protein Filter Composed of Hybrid Tissue-Fabric Material has a Long Lifetime.

    abstract::There are recent reports of hybrid tissue-fabric materials with good performance-high biocompatibility and high mechanical strength. In this study, we demonstrate the capability of a hybrid material as a long-term filter for blood proteins. Polyester fabrics were implanted into rats to fabricate hybrid tissue-fabric m...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-016-1781-5

    authors: Inoue Y,Yokota T,Sekitani T,Kaneko A,Woo T,Kobayashi S,Shibuya T,Tanaka M,Kosukegawa H,Saito I,Isoyama T,Abe Y,Yambe T,Someya T,Sekino M

    更新日期:2017-05-01 00:00:00

  • Bioreactors for development of tissue engineered heart valves.

    abstract::Millions of people worldwide are diagnosed each year with valvular heart disease, resulting in hundreds of thousands of valve replacement operations. Prosthetic valve replacements are designed to correct narrowing or backflow through the valvular orifice. Although commonly used, these therapies have serious disadvanta...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/s10439-010-0148-6

    authors: Berry JL,Steen JA,Koudy Williams J,Jordan JE,Atala A,Yoo JJ

    更新日期:2010-11-01 00:00:00

  • Probabilistic evaluation of predicted force sensitivity to muscle attachment and glenohumeral stability uncertainty.

    abstract::A major benefit of computational modeling in biomechanics research is its ability to estimate internal muscular demands given limited input information. However, several assumptions regarding model parameters and constraints may influence model outputs. This research evaluated the influence of model parameter variabil...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-014-1035-3

    authors: Chopp-Hurley JN,Langenderfer JE,Dickerson CR

    更新日期:2014-09-01 00:00:00

  • Contraction induced muscle injury: towards personalized training and recovery programs.

    abstract::Skeletal muscles can be injured by their own contractions. Such contraction-induced injury, often accompanied by delayed onset of muscle soreness, is a leading cause of the loss of mobility in the rapidly increasing population of elderly people. Unlike other types of muscle injuries which hurt almost exclusively those...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/s10439-014-1173-7

    authors: Givli S

    更新日期:2015-02-01 00:00:00

  • Fecobionics: A Novel Bionics Device for Studying Defecation.

    abstract::During defecation, solid, semisolid or liquid stools are eliminated via the anus in a complex physiological process. Up to 25% of the population are affected by anorectal disorders that are poorly recognized and treated. We developed a new bionics device, a simulated stool named Fecobionics, to replace several current...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-018-02149-1

    authors: Sun D,Huang Z,Zhuang Z,Ma Z,Man LK,Liao D,Gregersen H

    更新日期:2019-02-01 00:00:00

  • Tumor anti-angiogenic gene therapy with microencapsulated recombinant CHO cells.

    abstract::Microencapsulation of recombinant cells is a novel promising approach to tumor therapy in which therapeutic protein is sustainable and long-term delivered by microencapsulated cells. The semi-permeable membrane of microcapsule can protect cell from host's immune rejection, increase the chemical stability of therapeuti...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-007-9255-4

    authors: Zhang Y,Wang W,Zhou J,Yu W,Zhang X,Guo X,Ma X

    更新日期:2007-04-01 00:00:00

  • A review of the role of the partial pressure of carbon dioxide in mechanically loaded tissues: the canary in the cage singing in tune with the pressure ulcer mantra.

    abstract::Pressure ulcers (PUs) can occur in any situations where people are subjected to non-uniform distribution of pressure over a prolonged period. They can have devastating effects on the patients' well-being and in extreme conditions can prove fatal. In addition to traditional wisdom implicating mechanically induced ischa...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/s10439-014-1233-z

    authors: Mirtaheri P,Gjøvaag T,Worsley PR,Bader DL

    更新日期:2015-02-01 00:00:00

  • Investigation of the Sequential Actions of Doxorubicin and p53 on Tumor Cell Growth Via Branched Polyethylenimine-β-cyclodextrin Conjugates.

    abstract::The combination of gene therapy and chemotherapy has showed increased therapeutic efficacy in the treatment of cancers, but it is not well investigated about the actual coordination pattern between therapeutic gene and chemical drug. In this work, p53/BPEI-β-CD/AD-dox complex was fabricated and employed to investigate...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-016-1627-1

    authors: Xie B,Peng J,Wang S,Zhang X,Nie H

    更新日期:2016-11-01 00:00:00

  • Parameter estimation for linear compartmental models--a sensitivity analysis approach.

    abstract::Linear compartmental models are useful, explanatory tools, that have been widely used to represent the dynamic behavior of complex biological systems. This paper addresses the problem of the numerical identification of such models, i.e., the estimation of the parameter values that will generate predictions closest to ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-009-9651-z

    authors: Juillet B,Bos C,Gaudichon C,Tomé D,Fouillet H

    更新日期:2009-05-01 00:00:00

  • A computer reconstruction of the entire coronary arterial tree based on detailed morphometric data.

    abstract::A rigorous analysis of blood flow must be based on the branching pattern and vascular geometry of the full vascular circuit of interest. It is experimentally difficult to reconstruct the entire vascular circuit of any organ because of the enormity of the vessels. The objective of the present study was to develop a nov...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-005-5758-z

    authors: Mittal N,Zhou Y,Ung S,Linares C,Molloi S,Kassab GS

    更新日期:2005-08-01 00:00:00

  • Hemodynamic Influence on Smooth Muscle Cell Kinetics and Phenotype During Early Vein Graft Adaptation.

    abstract::Pathologic vascular adaptation following local injury is the primary driver for accelerated intimal hyperplasia and an occlusive phenotype. Smooth muscle cell (SMC) proliferation within the wall, and migration into the developing intima, is a major component of this remodeling response. The primary objective in the cu...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-016-1725-0

    authors: Klein B,Destephens A,Dumeny L,Hu Q,He Y,O'Malley K,Jiang Z,Tran-Son-Tay R,Berceli S

    更新日期:2017-03-01 00:00:00

  • Numerical validation of MR-measurement-integrated simulation of blood flow in a cerebral aneurysm.

    abstract::This study proposes magnetic resonance (MR)-measurement-integrated (MR-MI) simulation, in which the difference between the computed velocity field and the phase-contrast MRI measurement data is fed back to the numerical simulation. The computational accuracy and the fundamental characteristics, such as steady characte...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-009-9689-y

    authors: Funamoto K,Suzuki Y,Hayase T,Kosugi T,Isoda H

    更新日期:2009-06-01 00:00:00

  • A numerical implementation to predict residual strains from the homogeneous stress hypothesis with application to abdominal aortic aneurysms.

    abstract::Wall stress analysis of abdominal aortic aneurysm (AAA) is a promising method of identifying AAAs at high risk of rupture. However, neglecting residual strains (RS) in the load-free configuration of patient-specific finite element analysis models is a sever limitation that strongly affects the computed wall stresses. ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-013-0749-y

    authors: Polzer S,Bursa J,Gasser TC,Staffa R,Vlachovsky R

    更新日期:2013-07-01 00:00:00

  • Contourlet-based features for computerized tumor detection in capsule endoscopy images.

    abstract::This article presents a computer-aided detection system for capsule endoscopy (CE) images using contourlet-based color textural features to recognize tumors in the digestive tract. As tumor exhibits rich information in color texture, a novel color texture feature based on contourlet transform is proposed to describe c...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-011-0380-8

    authors: Li B,Meng MQ

    更新日期:2011-12-01 00:00:00

  • Analysis of electrically induced reentrant circuits in a sheet of myocardium.

    abstract::Understanding the complex spatiotemporal dynamics of action potential propagation in the heart during arrhythmia is exceedingly difficult. This study applies nonlinear dynamics tools to simplify this task. Using the results of a simulation of an electrical induction of reentry in a sheet of myocardium represented as a...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1581289

    authors: Larson C,Dragnev L,Trayanova N

    更新日期:2003-07-01 00:00:00

  • Influence of different presentations of oscillometric data on automatic determination of systolic and diastolic pressures.

    abstract::Most non-invasive blood pressure measurements are based on either the auscultatory or the oscillometric technique. In this study, we performed an extensive analysis of the signals, i.e., responses of a microphone implanted in the cuff and pressure changes in the cuff, which can be recorded during such measurements. We...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-009-9853-4

    authors: Jazbinsek V,Luznik J,Mieke S,Trontelj Z

    更新日期:2010-03-01 00:00:00

  • Information systems approach to integrated responses in the respiratory control system.

    abstract::The appropriateness of integrated information systems to the description of integrated biological systems is discussed. An integrated information system in the physiology of the regulation of respiration is argued to be a structural mathematical model of the system and the relational data base, which it can compute. I...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02363292

    authors: Yamamoto WS

    更新日期:1983-01-01 00:00:00

  • Net change in periosteal strain during stance shift loading after surgery correlates to rapid de novo bone generation in critically sized defects.

    abstract::In an ovine femur model, proliferative woven bone fills critically sized defects enveloped by periosteum within 2 weeks of treatment with the one-stage bone-transport surgery. We hypothesize that mechanical loading modulates this process. Using high-definition optical strain measurements we determined prevailing perio...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-0242-9

    authors: McBride SH,Dolejs S,Brianza S,Knothe U,Knothe Tate ML

    更新日期:2011-05-01 00:00:00

  • Modulation of rod photoreceptor potassium Kx current by divalent cations.

    abstract::Similarities between photoreceptor Kx channels and EAG and KCNQ channels suggest that the Kx channel may be related to one or both of these families of potassium channels. To provide a basis for further comparison of these channels, as well as to reveal the role of zinc (endogenously present in photoreceptors) in Kx c...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1521415

    authors: Kourennyi DE,Liu X,Barnes S

    更新日期:2002-01-01 00:00:00

  • Sensitivity of indentation testing to step-off edges and interface integrity in cartilage repair.

    abstract::Step-off edges and tissue interfaces are prevalent in cartilage injury such as after intra-articular fracture and reduction, and in focal defects and surgical repair procedures such as osteochondral graft implantation. It would be useful to assess the function of injured or donor tissues near such step-off edges and t...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1023/b:abme.0000017553.01798.12

    authors: Bae WC,Law AW,Amiel D,Sah RL

    更新日期:2004-03-01 00:00:00

  • Nanoparticle-Mediated TGF-β Release from Microribbon-Based Hydrogels Accelerates Stem Cell-Based Cartilage Formation In Vivo.

    abstract::Conventional nanoporous hydrogels often lead to slow cartilage deposition by MSCs in 3D due to physical constraints and requirement for degradation. Our group has recently reported macroporous gelatin microribbon (μRB) hydrogels, which substantially accelerate MSC-based cartilage formation in vitro compared to convent...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02522-z

    authors: Barati D,Gegg C,Yang F

    更新日期:2020-07-01 00:00:00

  • Computational study of fluid mechanical disturbance induced by endovascular stents.

    abstract::Arterial restenosis following stent deployment may be influenced by the local flow environment within and around the stent. We have used computational fluid dynamics to investigate the flow field in the vicinity of model stents positioned within straight and curved vessels. Our simulations have revealed the presence o...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-005-2499-y

    authors: Seo T,Schachter LG,Barakat AI

    更新日期:2005-04-01 00:00:00