Mechanical analysis of atherosclerotic plaques based on optical coherence tomography.

Abstract:

:Finite element analysis is a powerful tool for investigating the biomechanics of atherosclerosis and has thereby provided an improved understanding of acute myocardial infarction. Structural analysis of arterial walls is traditionally performed using geometry contours derived from histology. In this paper we demonstrate the first use of a new imaging technique, optical coherence tomography (OCT), as a basis for finite element analysis. There are two primary benefits of OCT relative to histology: 1) imaging is performed without excessive tissue handling, providing a more realistic geometry than histology and avoiding structural artifacts common to histologic processing, and 2) OCT imaging can be performed in vivo, making it possible to study disease progression and the effect of therapeutic treatments in animal models and living patients. Patterns of mechanical stress and strain distributions computed from finite element analysis based on OCT were compared with those from modeling based on "gold standard" histology. Our results indicate that vascular structure and composition determined by OCT provides an adequate basis for investigating the biomechanical factors relevant to atherosclerosis and acute myocardial infarction.

journal_name

Ann Biomed Eng

authors

Chau AH,Chan RC,Shishkov M,MacNeill B,Iftimia N,Tearney GJ,Kamm RD,Bouma BE,Kaazempur-Mofrad MR

doi

10.1114/b:abme.0000049034.75368.4a

subject

Has Abstract

pub_date

2004-11-01 00:00:00

pages

1494-503

issue

11

eissn

0090-6964

issn

1573-9686

journal_volume

32

pub_type

杂志文章
  • Optimization of pulse train duration for the electrical stimulation of a skeletal muscle ventricle in the dog.

    abstract::The optimal means of electrically stimulating a skeletal muscle to contract around a fluid-filled pouch (i.e., a skeletal muscle ventricle [SMV]) has not been determined. A SMV was made from the latissimus dorsi muscle in five dogs and the rectus abdominis muscle in five dogs, and each SMV was electrically stimulated ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02364611

    authors: Badylak SF,Wessale JE,Geddes LA,Janas W

    更新日期:1990-01-01 00:00:00

  • Hydraulic Conductivity of Smooth Muscle Cell-Initiated Arterial Cocultures.

    abstract::The purpose of the study was to examine the effects of arterial coculture conditions on the transport properties of several in vitro endothelial cell (EC)-smooth muscle cell (SMC)-porous filter constructs in which SMC were grown to confluence first and then EC were inoculated. This order of culturing simulates the env...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1421-5

    authors: Mathura RA,Russell-Puleri S,Cancel LM,Tarbell JM

    更新日期:2016-05-01 00:00:00

  • Stress relaxation preconditioning of porcine aortic valves.

    abstract::In uniaxial tensile testing, load preconditioning is used to generate repeatable load/elongation curves and set a "reference state" for subsequent tensile tests. We have observed however, that for porcine aortic valve (PAV) tissues, preconditioning does not lead to repeatable stress relaxation curves. We thus investig...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1023/b:abme.0000019176.49650.19

    authors: Carew EO,Garg A,Barber JE,Vesely I

    更新日期:2004-04-01 00:00:00

  • Simulation of neutrophil deformation and transport in capillaries using newtonian and viscoelastic drop models.

    abstract::It is well known that neutrophils take much longer to traverse the pulmonary capillary bed than erythrocytes, and this is likely due to differences in the structure and rheology of the cells. In this study, we simulate the transit of a neutrophil in a capillary using a Newtonian drop model and a viscoelastic drop mode...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-007-9286-x

    authors: Zhou C,Yue P,Feng JJ

    更新日期:2007-05-01 00:00:00

  • Cardiac Multi-detector CT Segmentation Based on Multiscale Directional Edge Detector and 3D Level Set.

    abstract::Extraction of the cardiac surfaces of interest from multi-detector computed tomographic (MDCT) data is a pre-requisite step for cardiac analysis, as well as for image guidance procedures. Most of the existing methods need manual corrections, which is time-consuming. We present a fully automatic segmentation technique ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,随机对照试验

    doi:10.1007/s10439-015-1422-4

    authors: Antunes S,Esposito A,Palmisano A,Colantoni C,Cerutti S,Rizzo G

    更新日期:2016-05-01 00:00:00

  • Cue-Signal-Response Analysis in 3D Chondrocyte Scaffolds with Anabolic Stimuli.

    abstract::Articular cartilage is an avascular connective tissue responsible for bearing loads. Cell signaling plays a central role in cartilage homeostasis and tissue engineering by directing chondrocytes to synthesize/degrade the extracellular matrix or promote inflammatory responses. The aim of this paper was to investigate a...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-017-1964-8

    authors: Neidlin M,Korcari A,Macheras G,Alexopoulos LG

    更新日期:2018-02-01 00:00:00

  • The role of nanomedicine in growing tissues.

    abstract::Nanomedicine (a division of nanotechnology) is an interdisciplinary research field incorporating biology, chemistry, engineering and medicine with the intention to improve disease prevention, diagnosis, and treatment. Specifically, there have been great strides made in using nanomedicine to enhance the functions of ce...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/s10439-009-9722-1

    authors: Chun YW,Webster TJ

    更新日期:2009-10-01 00:00:00

  • Rapid platelet accumulation leading to thrombotic occlusion.

    abstract::Platelet thrombosis under arterial conditions remains a large clinical problem. Previous in vitro experiments have concentrated on early adherence without thrombotic occlusion. We have developed a controllable hemodynamic system that creates intravascular thrombosis to occlusion. Lightly heparinized (3.5 USP units/mL)...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-011-0296-3

    authors: Para A,Bark D,Lin A,Ku D

    更新日期:2011-07-01 00:00:00

  • Contraction induced muscle injury: towards personalized training and recovery programs.

    abstract::Skeletal muscles can be injured by their own contractions. Such contraction-induced injury, often accompanied by delayed onset of muscle soreness, is a leading cause of the loss of mobility in the rapidly increasing population of elderly people. Unlike other types of muscle injuries which hurt almost exclusively those...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/s10439-014-1173-7

    authors: Givli S

    更新日期:2015-02-01 00:00:00

  • Automatic Model Generation Framework for Computational Simulation of Cochlear Implantation.

    abstract::Recent developments in computational modeling of cochlear implantation are promising to study in silico the performance of the implant before surgery. However, creating a complete computational model of the patient's anatomy while including an external device geometry remains challenging. To address such a challenge, ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1541-y

    authors: Mangado N,Ceresa M,Duchateau N,Kjer HM,Vera S,Dejea Velardo H,Mistrik P,Paulsen RR,Fagertun J,Noailly J,Piella G,González Ballester MÁ

    更新日期:2016-08-01 00:00:00

  • Influence of autoregressive model parameter uncertainty on spectral estimates of heart rate dynamics.

    abstract::Linear autoregressive (AR) model-based heart rate (HR) spectral analysis has been widely used to study HR dynamics. Owing to system and measurement noise, the parameters of an AR model have intrinsic statistical uncertainty. In this study, we evaluate how this AR parameter uncertainty can translate to uncertainty in H...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02368320

    authors: Christini DJ,Kulkarni A,Rao S,Stutman ER,Bennett FM,Hausdorff JM,Oriol N,Lutchen KR

    更新日期:1995-03-01 00:00:00

  • Detergent-Based Decellularization of Bovine Carotid Arteries for Vascular Tissue Engineering.

    abstract::Vascular diseases are an increasing health issue, and common alloplastic, allogenic or autologous vascular grafts show frequent complications. The aim of this study is to develop an acellular, xenogenic bypass-graft from a bovine carotid artery (BAC) using detergent-based protocols. We compared decellularization with ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-017-1892-7

    authors: Daugs A,Hutzler B,Meinke M,Schmitz C,Lehmann N,Markhoff A,Bloch O

    更新日期:2017-11-01 00:00:00

  • Surfactant properties differentially influence intravascular gas embolism mechanics.

    abstract::Gas bubble motion in a blood vessel causes temporal and spatial gradients of shear stress at the cell surface lining the vessel wall as the bubble approaches the cell, moves over it and passes it by. Rapid reversals occur in the sign of the shear stress imparted to the cell surface during this motion. These may result...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-0120-5

    authors: Swaminathan TN,Ayyaswamy PS,Eckmann DM

    更新日期:2010-12-01 00:00:00

  • In situ Microrheological Determination of Neutrophil Stiffening Following Adhesion in a Model Capillary.

    abstract::There has been considerable debate on the relative importance of biochemical stimuli and mechanical deformation in neutrophil adhesion in lung capillaries, a process observed following bacterial infection in the body. In contrast to venules, where the vessel diameter is larger than the leukocyte diameter (6-9 microm) ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-008-9437-8

    authors: Pai A,Sundd P,Tees DF

    更新日期:2008-04-01 00:00:00

  • A fuzzy pattern recognition method to classify esophageal motility records.

    abstract::Analysis and classification of esophageal motility records were investigated using signal processing and fuzzy-set pattern recognition techniques. A set of parameters has been extracted from the raw records and has previously been used as characterizing features. Improvements to these procedures were obtained by extra...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02368227

    authors: Abou-Chadi FE,Ezzat FA,Sif el-Din AA

    更新日期:1994-01-01 00:00:00

  • Human saphenous vein coronary artery bypass graft morphology, geometry and hemodynamics.

    abstract::Coronary artery bypass graft (CABG) failure has been linked to graft hemodynamics, in particular wall shear stress. This study characterizes the morphology, geometry and wall shear stress patterns in human CABGs. The intimal thickness (IT) in 49 human saphenous vein CABGs was measured by digital light microscopy. The ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-005-1732-z

    authors: Leask RL,Butany J,Johnston KW,Ethier CR,Ojha M

    更新日期:2005-03-01 00:00:00

  • An optimization algorithm for human joint angle time-history generation using external force data.

    abstract::A mathematical model is presented that estimates joint kinematics and kinetics using measured external resultant loads and readily available parameters. The musculo-skeletal system was represented by a planar three degrees of freedom open kinematic chain. Information extraction was limited to the flexion-extension fun...

    journal_title:Annals of biomedical engineering

    pub_type: 临床试验,杂志文章

    doi:10.1023/b:abme.0000030241.26857.75

    authors: Mazzà C,Cappozzo A

    更新日期:2004-05-01 00:00:00

  • Genetics of energetics: transcriptional responses in cardiac metabolism.

    abstract::Recent evidence suggests that energy substrate metabolism forms the link between gene expression and contractile function of the heart. This hypothesis draws on three seemingly unconnected observations, made in 1941 by three different investigators. The first gave rise to the concept of the dynamic nature of body cons...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1114/1.1312187

    authors: Taegtmeyer H

    更新日期:2000-08-01 00:00:00

  • Cellular and Nuclear Alignment Analysis for Determining Epithelial Cell Chirality.

    abstract::Left-right (LR) asymmetry is a biologically conserved property in living organisms that can be observed in the asymmetrical arrangement of organs and tissues and in tissue morphogenesis, such as the directional looping of the gastrointestinal tract and heart. The expression of LR asymmetry in embryonic tissues can be ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1431-3

    authors: Raymond MJ Jr,Ray P,Kaur G,Singh AV,Wan LQ

    更新日期:2016-05-01 00:00:00

  • Lensfree optofluidic microscopy and tomography.

    abstract::Microfluidic devices aim at miniaturizing, automating, and lowering the cost of chemical and biological sample manipulation and detection, hence creating new opportunities for lab-on-a-chip platforms. Recently, optofluidic devices have also emerged where optics is used to enhance the functionality and the performance ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/s10439-011-0385-3

    authors: Bishara W,Isikman SO,Ozcan A

    更新日期:2012-02-01 00:00:00

  • Geometric and flow features of type B aortic dissection: initial findings and comparison of medically treated and stented cases.

    abstract::Uncomplicated acute type B aortic dissections are usually treated medically, but they can become acutely complicated by rapid expansion, rupture and malperfusion syndromes and in the longer term by chronic dilatation and aortic aneurysm formation. The objective of this study is to use computational fluid dynamics reco...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-014-1075-8

    authors: Cheng Z,Wood NB,Gibbs RG,Xu XY

    更新日期:2015-01-01 00:00:00

  • Behavior of human mesenchymal stem cells in fibrin-based vascular tissue engineering constructs.

    abstract::A limitation of current tissue engineering vascular graft technology is the provision of an expandable, autologous cell source. By harnessing the multipotency of mesenchymal stem cells (MSC), it is hoped that functional vascular cells can be produced. To date, a range of 2D and 3D environments have been investigated f...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-9912-x

    authors: O'Cearbhaill ED,Murphy M,Barry F,McHugh PE,Barron V

    更新日期:2010-03-01 00:00:00

  • A general framework for characterizing studies of brain interface technology.

    abstract::The development of brain interface (BI) technology continues to attract researchers with a wide range of backgrounds and expertise. Though the BI community is committed to accurate and objective evaluation of methods, systems, and technology, the very diversity of the methods and terminology used in the field hinders ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-005-7706-3

    authors: Mason SG,Jackson MM,Birch GE

    更新日期:2005-11-01 00:00:00

  • Resistances and compliances of a compartmental model of the cerebrovascular system.

    abstract::A lumped parameter compartmental model for the nonsteady flow of the cerebrovascular fluid is constructed. The model assumes constant resistances that relate fluid flux to pressure gradients, and compliances between compartments that relate fluid accumulation to rate of pressure changes. Resistances are evaluated by u...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02364270

    authors: Sorek S,Bear J,Karni Z

    更新日期:1989-01-01 00:00:00

  • Effect of extracellular potassium accumulation on muscle fiber conduction velocity: a simulation study.

    abstract::A progressive reduction in muscle fiber conduction velocity is typically observed during fatiguing muscle contraction. Although the exact causes of the conduction velocity decrease have not yet been fully established, increasing evidence suggests that changes in extracellular potassium concentration may be largely res...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-009-9756-4

    authors: Fortune E,Lowery MM

    更新日期:2009-10-01 00:00:00

  • CareToy: Stimulation and Assessment of Preterm Infant's Activity Using a Novel Sensorized System.

    abstract::Early intervention programs aim at improving cognitive and motor outcomes of preterm infants. Intensive custom-tailored training activities are usually accompanied by assessment procedures, which have shortcomings, such as subjectivity, complex setups, and need for structured environments. A novel sensorized system, c...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-016-1669-4

    authors: Rihar A,Sgandurra G,Beani E,Cecchi F,Pašič J,Cioni G,Dario P,Mihelj M,Munih M

    更新日期:2016-12-01 00:00:00

  • A piconewton force transducer and its application to measurement of the bending stiffness of phospholipid membranes.

    abstract::The bending stiffness of a phospholipid bilayer (Kc) was measured by forming thin bilayer cylinders (tethers) from giant phospholipid vesicles. Based on the balance of forces, the tether force was expected to be proportional to the square root of the membrane tension, with a constant of proportionality containing Kc. ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02684228

    authors: Heinrich V,Waugh RE

    更新日期:1996-09-01 00:00:00

  • Dual energy CT scanning for analysis of brain damage due to X-irradiation.

    abstract::Therapeutic irradiation is commonly used in the treatment of malignant brain tumors and has the potential to cause severe injury to normal tissues adjacent to a lesion. Computed tomography (CT) can be used not only to visualize tissue damage but to monitor the development of a lesion using advanced quantitative CT tec...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02410288

    authors: Russell LB,Fike JR,Cann CE,Süsskind C

    更新日期:1984-01-01 00:00:00

  • Do Head Injury Biomechanics Predict Concussion Clinical Recovery in College American Football Players?

    abstract::Identifying the associations between head impact biomechanics and clinical recovery may inform better head impact monitoring procedures and identify athletes who may benefit from early treatments aimed to enhance recovery. The purpose of this study was to test whether head injury biomechanics are associated with clini...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02658-y

    authors: Mihalik JP,Chandran A,Powell JR,Roby PR,Guskiewicz KM,Stemper BD,Shah AS,Rowson S,Duma S,Harezlak J,Riggen L,Broglio SP,McAllister TW,McCrea M,CARE Consortium Investigators.

    更新日期:2020-11-01 00:00:00

  • Nanoparticle deposition onto biofilms.

    abstract::We develop a mathematical model of nanoparticles depositing onto and penetrating into a biofilm grown in a parallel-plate flow cell. We carry out deposition experiments in a flow cell to support the modeling. The modeling and the experiments are motivated by the potential use of polymer nanoparticles as part of a trea...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-012-0626-0

    authors: Miller JK,Neubig R,Clemons CB,Kreider KL,Wilber JP,Young GW,Ditto AJ,Yun YH,Milsted A,Badawy HT,Panzner MJ,Youngs WJ,Cannon CL

    更新日期:2013-01-01 00:00:00