Abstract:
:Blunt carotid artery injuries occur in 0.3% of blunt injured patients and may lead to devastating neurological consequences. However, arterial mechanics leading to internal layer subfailure have not been quantified. Twenty-two human carotid artery segments and 18 porcine thoracic aorta segments were opened to expose the intimal side and longitudinally distracted to failure. Porcine aortas were a geometrically accurate model of human carotid arteries. Internal layer subfailures were identified using videography and correlated with mechanical data. Ninety-three percent (93%) of vessels demonstrated subfailure prior to catastrophic failure. All subfailures occurred on the intimal surface. Initial subfailure occurred at 79% of the stress and 85% of the strain to catastrophic failure in younger porcine specimens, compared to 44% and 60%, respectively, in older human specimens. In most cases, multiple subfailures occurred prior to catastrophic failure. Due to limitations in human specimen quality (age, prior storage), young and fresh porcine aorta specimens are likely a more accurate model of clinical blunt carotid artery injuries. Present results indicate that vessels are acutely capable of maintaining physiologic function following initial subfailure. Delayed symptomatology commonly associated with blunt arterial injuries is explained by this mechanics-based and experimentally quantified onset of subcatastrophic failure.
journal_name
Ann Biomed Engjournal_title
Annals of biomedical engineeringauthors
Stemper BD,Yoganandan N,Sinson GP,Gennarelli TA,Stineman MR,Pintar FAdoi
10.1007/s10439-006-9229-ysubject
Has Abstractpub_date
2007-02-01 00:00:00pages
285-91issue
2eissn
0090-6964issn
1573-9686journal_volume
35pub_type
杂志文章abstract::Static and dynamic components of the stretch reflex were studied in elbow flexors of 13 hemiparetic brain-injured individuals. Constant-velocity joint rotations were applied to the elbow, and the resulting stretch reflex torque and electromyographic responses were recorded in the biceps brachii and brachioradialis mus...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1114/1.1359496
更新日期:2001-04-01 00:00:00
abstract::In this paper, we present the application of a semi-global inverse method for determining material parameters of biological tissues. The approach is based on the successive response surface method, and is illustrated by fitting constitutive parameters to two nonlinear anisotropic constitutive equations, one for aortic...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-005-8338-3
更新日期:2005-12-01 00:00:00
abstract::This article presents a computer-aided detection system for capsule endoscopy (CE) images using contourlet-based color textural features to recognize tumors in the digestive tract. As tumor exhibits rich information in color texture, a novel color texture feature based on contourlet transform is proposed to describe c...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-011-0380-8
更新日期:2011-12-01 00:00:00
abstract::Biochemical stimulation was applied in combination with cyclic mechanical strain to engineered vascular constructs made of isolated smooth muscle cells in a three-dimensional (3D) collagen type 1 matrix. Platelet-derived growth factor (PDGF) and transforming growth factor beta (TGF-beta) were added exogenously to the ...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1114/1.1558031
更新日期:2003-04-01 00:00:00
abstract::Continuous flow left ventricular devices (CF-LVADs) support the failing heart at a constant speed and alters the loads on the aortic valve. This may cause insufficiency in the aortic valve under long-term CF-LVAD support. The aim of this study is to assess the aortic valve function under varying speed CF-LVAD support....
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-014-1204-4
更新日期:2015-08-01 00:00:00
abstract::Wall stress analysis of abdominal aortic aneurysm (AAA) is a promising method of identifying AAAs at high risk of rupture. However, neglecting residual strains (RS) in the load-free configuration of patient-specific finite element analysis models is a sever limitation that strongly affects the computed wall stresses. ...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-013-0749-y
更新日期:2013-07-01 00:00:00
abstract::The field of percutaneous coronary intervention has witnessed many progressions over the last few decades, more recently with the advancement of fully degradable bioabsorbable stents. Bioabsorbable materials, such as metallic alloys and aliphatic polyesters, have the potential to yield stents which provide temporary s...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章,评审
doi:10.1007/s10439-015-1413-5
更新日期:2016-02-01 00:00:00
abstract::Development of increasingly complex integrated cellular systems will be a major challenge for the next decade and beyond, as we apply the knowledge gained from the sub-disciplines of regenerative medicine, synthetic biology, micro-fabrication and nanotechnology, systems biology, and developmental biology. In this pros...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章,评审
doi:10.1007/s10439-013-0902-7
更新日期:2014-02-01 00:00:00
abstract::Upon nerve injury, the body creates an environment consisting of permissive and non-permissive cues that instruct the function of cells involved in nerve repair. Among other roles, the developing extracellular matrix (ECM) acts as an underlying substrate to guide the union of neurites extending from the proximal stump...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-014-0991-y
更新日期:2014-06-01 00:00:00
abstract::Point cathodal stimulation of cardiac tissue was shown previously to produce both a dog-bone shaped virtual cathode transverse to the muscle fibers and two longitudinal virtual anodes. We hypothesize that virtual anodes can cause a region of delayed activation, separating two regions of early activation caused by the ...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1114/1.1326029
更新日期:2000-11-01 00:00:00
abstract::A comparison was made between turbulence calculated by subtracting an ensemble average from the instantaneous velocity and calculations made with a high pass digital filter. Velocity was measured with a laser Doppler anemometer in vitro in the region of a normal porcine aortic valve and in patients with a hot film ane...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/BF02584215
更新日期:1983-01-01 00:00:00
abstract::The long held assumption that sustained drug elution from stent coatings over weeks to months is imperative for clinical efficacy has limited the choice for stent coating materials. We developed and evaluated an omega-3 fatty acid (O3FA) based stent coating that is 85% absorbed and elutes 97% of its Sirolimus analog (...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-015-1435-z
更新日期:2016-02-01 00:00:00
abstract::The great success of stents in treating cardiovascular disease is actually undermined by their long-term fatigue failure. The high variability of stent failure incidence suggests that it is due to several correlated aspects, such as loading conditions, material properties, component design, surgical procedure, and pat...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-015-1447-8
更新日期:2016-02-01 00:00:00
abstract::We have studied the interaction of high frequency jet ventilation with cardiovascular pressures and flows. Results in dogs show that the amplitude of all intrathoracic pressures and flows fluctuate with a frequency equal to the difference between the heart rate and ventilator rate. The magnitude of this amplitude vari...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/BF02584287
更新日期:1987-01-01 00:00:00
abstract::Impedance cardiography has not achieved popularity in the Intensive Care Unit (ICU) to date probably because of the limitations in technique and interpretation associated with the altered physiology of critically ill patients, and also because of interference from other machinery in the ICU. The current climate of que...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/BF02368068
更新日期:1989-01-01 00:00:00
abstract::The blood-brain barrier (BBB) is a major obstacle for drug delivery to the brain. To seek for in vitro BBB models that are more accessible than animals for investigating drug transport across the BBB, we compared four in vitro cultured cell models: endothelial monoculture (bEnd3 cell line), coculture of bEnd3 and prim...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-010-0023-5
更新日期:2010-08-01 00:00:00
abstract::We describe a model for the Compound Action Currents (CACs) and Compound Action Potentials (CAPs) produced by a peripheral nerve bundle in vitro. The Single Fiber Action Currents (SFACs) and the extracellular Single Fiber Action Potentials (SFAPs) are calculated using a generalized volume conduction model. Frequency-d...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/BF02368460
更新日期:1991-01-01 00:00:00
abstract::New porous implant designs made possible by additive manufacturing allow for increased osseointegration, potentially improving implant performance and longevity for patients that require massive bone implants. The aim of this study was to evaluate how implantation and the strain distribution in the implant affect the ...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-019-02369-z
更新日期:2020-01-01 00:00:00
abstract::We propose a multifrequency energy transmission scheme for annular phased arrays in deep-body hyperthermia. The problem of frequency dependent resonance effects reported in hyperthermia phantom calibration studies, leading to skewed energy deposition patterns and unwanted energy maxima (hot spots), is addressed by com...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1114/1.1430749
更新日期:2002-01-01 00:00:00
abstract::The development of brain interface (BI) technology continues to attract researchers with a wide range of backgrounds and expertise. Though the BI community is committed to accurate and objective evaluation of methods, systems, and technology, the very diversity of the methods and terminology used in the field hinders ...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-005-7706-3
更新日期:2005-11-01 00:00:00
abstract::Current efforts to evaluate the performance of laparoscopic arterial fusion devices are limited to costly, time consuming, empirical studies. Thus, a finite element (FE) model, with the ability to predict device performance would improve device design and reduce development time and costs. This study introduces a mode...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-016-1588-4
更新日期:2016-11-01 00:00:00
abstract::Coronary artery bypass graft (CABG) failure has been linked to graft hemodynamics, in particular wall shear stress. This study characterizes the morphology, geometry and wall shear stress patterns in human CABGs. The intimal thickness (IT) in 49 human saphenous vein CABGs was measured by digital light microscopy. The ...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-005-1732-z
更新日期:2005-03-01 00:00:00
abstract::In an ovine femur model, proliferative woven bone fills critically sized defects enveloped by periosteum within 2 weeks of treatment with the one-stage bone-transport surgery. We hypothesize that mechanical loading modulates this process. Using high-definition optical strain measurements we determined prevailing perio...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-010-0242-9
更新日期:2011-05-01 00:00:00
abstract::Rupture of abdominal aortic aneurysm (AAA) is associated with high mortality rates. Risk of rupture is multi-factorial involving AAA geometric configuration, vessel tortuosity, and the presence of intraluminal pathology. Fluid structure interaction (FSI) simulations were conducted in patient based computed tomography ...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-014-1224-0
更新日期:2015-01-01 00:00:00
abstract::The geometric and hemodynamic characteristics of the left and right vertebral arteries (LVA, RVA) of six healthy volunteers were investigated for the supine (S) and the prone position (P) a common sleeping posture with head rotation. MRI images were used to reconstruct the subject specific three-dimensional solid mode...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-015-1340-5
更新日期:2015-06-01 00:00:00
abstract::Finite element analysis is a powerful tool for investigating the biomechanics of atherosclerosis and has thereby provided an improved understanding of acute myocardial infarction. Structural analysis of arterial walls is traditionally performed using geometry contours derived from histology. In this paper we demonstra...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1114/b:abme.0000049034.75368.4a
更新日期:2004-11-01 00:00:00
abstract::Vascular diseases are an increasing health issue, and common alloplastic, allogenic or autologous vascular grafts show frequent complications. The aim of this study is to develop an acellular, xenogenic bypass-graft from a bovine carotid artery (BAC) using detergent-based protocols. We compared decellularization with ...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-017-1892-7
更新日期:2017-11-01 00:00:00
abstract::While considerable efforts have been expended to develop snore-driven markers for detecting obstructive sleep apnea (OSA), there is little emphasis on the relationship between the human upper airway (UA) dimensions and the attributes of snores. This paper aims to investigate the acoustical and perceptual impacts of ch...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-009-9745-7
更新日期:2009-09-01 00:00:00
abstract::Modern models of cardiac membranes are often highly complex and computationally expensive, particularly when used in long simulations of spatially extended models of cardiac tissue. Therefore, there is a need for simpler membrane models that preserve the features of the complex models deemed important. This communicat...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-005-3948-3
更新日期:2005-07-01 00:00:00
abstract::Twenty-one 3.5-month-old female Sprague-Dawley rats were randomly assigned to three groups: BTX group, in which each rat received a single intramuscular injection of 2 U of Clostridium botulinum toxin (BTX) in the quadriceps femoris muscle of the right hind limb; BTX + SR group, in which each rat received a BTX inject...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-011-0406-2
更新日期:2012-03-01 00:00:00