Role of upper airway dimensions in snore production: acoustical and perceptual findings.

Abstract:

:While considerable efforts have been expended to develop snore-driven markers for detecting obstructive sleep apnea (OSA), there is little emphasis on the relationship between the human upper airway (UA) dimensions and the attributes of snores. This paper aims to investigate the acoustical and perceptual impacts of changing the cross-sectional areas (CSA) of the pharynx and oral cavity on the production of snores. Synthetic snores were generated based on the source-filter theory, whereas natural snores were recorded from 40 snorers during nocturnal polysomnography. First formant frequency (F1), spectral peak frequency (PF), and psychoacoustic metrics (loudness, sharpness, roughness, fluctuation strength, and annoyance) of CSA perturbations were examined, completed with diagnostic appraisal of F1 and PF for single- and mixed-gender groupings using the receiver operating characteristic curve analysis. Results show that (1) narrowing the pharyngeal airway consistently increases F1, but not for PF; and (2) altering the airway dimensions yield no considerable differences in perception of snore sounds, but indirectly affect the psychoacoustics by changing the dynamics of snore source flow. Diagnostic outcomes for all groupings (p-value < 0.0001) demonstrate that F1 is more capable of distinguishing apneic and benign snorers than PF due to the close association of F1 with the UA anatomical structures. Correlation exists between the UA anatomy and the properties of snores; there is a promising future for developing snore-driven screening tools for OSA.

journal_name

Ann Biomed Eng

authors

Ng AK,Koh TS,Baey E,Puvanendran K

doi

10.1007/s10439-009-9745-7

subject

Has Abstract

pub_date

2009-09-01 00:00:00

pages

1807-17

issue

9

eissn

0090-6964

issn

1573-9686

journal_volume

37

pub_type

杂志文章
  • Intracellular trafficking considerations in the development of natural ligand-drug molecular conjugates for cancer.

    abstract::Overexpressed receptors, characteristic of many cancers, have been targeted by various researchers to achieve a more specific treatment for cancer. A common approach is to use the natural ligand for the overexpressed receptor as a cancer-targeting agent which can deliver a chemically or genetically conjugated toxic mo...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/s10439-011-0280-y

    authors: Yoon DJ,Liu CT,Quinlan DS,Nafisi PM,Kamei DT

    更新日期:2011-04-01 00:00:00

  • Length-Change Patterns of the Collateral Ligaments During Functional Activities After Total Knee Arthroplasty.

    abstract::This study aimed to quantify the elongation patterns of the collateral ligaments following TKA during functional activities of daily living. Using mobile video-fluoroscopy to capture radiographic images of the knee in a group of six patients, each with an ultra-congruent knee implant, tibiofemoral kinematics were reco...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02459-3

    authors: Hosseini Nasab SH,Smith CR,Schütz P,Damm P,Trepczynski A,List R,Taylor WR

    更新日期:2020-04-01 00:00:00

  • In vitro, time-resolved PIV comparison of the effect of stent design on wall shear stress.

    abstract::The effect of stent design on wall shear stress (WSS) and oscillatory shear index (OSI) was studied in vitro using time-resolved digital particle image velocimetry (DPIV). Four drug-eluting stents [XIENCE V (Abbott Vascular), TAXUS Liberté (Boston Scientific), Endeavor (Medtronic), and Cypher (J&J Cordis)] and a bare-...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-009-9697-y

    authors: Charonko J,Karri S,Schmieg J,Prabhu S,Vlachos P

    更新日期:2009-07-01 00:00:00

  • Creep deformation of the human trunk in response to prolonged and repetitive flexion: measuring and modeling the effect of external moment and flexion rate.

    abstract::While viscoelastic responses of isolated trunk soft tissues have been characterized in earlier studies, the effects of external loading and flexion rate on these responses in the intact human trunk are largely unknown. Two experiments were conducted to measure trunk viscoelastic behaviors, one involving prolonged flex...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-013-0797-3

    authors: Toosizadeh N,Nussbaum MA

    更新日期:2013-06-01 00:00:00

  • Electrospinning of nanocomposite fibrillar tubular and flat scaffolds with controlled fiber orientation.

    abstract::Electrospinning was used in innovative electrospinning rigs to obtain tubular and flat fibrous structures with controlled fiber orientation with the aim to be used as scaffolds for biomedical applications, more specifically in the tissue engineering of vascular and orthopedic grafts. Gelatine and hydroxyapatite (HA)-g...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-011-0350-1

    authors: Salifu AA,Nury BD,Lekakou C

    更新日期:2011-10-01 00:00:00

  • Generalized sensitivity functions in physiological system identification.

    abstract::Parameters of physiological models are commonly associated in an input-output experiment with a specific pattern of the system response. This association is often made on an intuitive basis by traditional sensitivity analysis, i.e., by inspecting the variations of model output trajectories with respect to parameter va...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.207

    authors: Thomaseth K,Cobelli C

    更新日期:1999-09-01 00:00:00

  • Reinforcement of Mono- and Bi-layer Poly(Ethylene Glycol) Hydrogels with a Fibrous Collagen Scaffold.

    abstract::Biomaterial-based tissue engineering strategies hold great promise for osteochondral tissue repair. Yet significant challenges remain in joining highly dissimilar materials to achieve a biomimetic, mechanically robust design for repairing interfaces between soft tissue and bone. This study sought to improve interfacia...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1337-0

    authors: Kinneberg KR,Nelson A,Stender ME,Aziz AH,Mozdzen LC,Harley BA,Bryant SJ,Ferguson VL

    更新日期:2015-11-01 00:00:00

  • A novel approach to track fetal movement using multi-sensor magnetocardiographic recordings.

    abstract::Changes in fetal magnetocardiographic (fMCG) signals are indicators for fetal body movement. We propose a novel approach to reliably extract fetal body movements based on the field strength of the fMCG signal independent of its frequency. After attenuating the maternal MCG, we use a Hilbert transform approach to ident...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-0231-z

    authors: Govindan RB,Vairavan S,Ulusar UD,Wilson JD,McKelvey SS,Preissl H,Eswaran H

    更新日期:2011-03-01 00:00:00

  • User customization of the feature generator of an asynchronous brain interface.

    abstract::A study that customizes the feature generator parameters of an asynchronous Brain Interface (BI) is discussed. The goal is to detect the presence of a certain pattern, in the ongoing EEG, associated with a specific movement and to improve the system's performance. Results of this study show that customization mostly b...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-006-9097-5

    authors: Bashashati A,Fatourechi M,Ward RK,Birch GE

    更新日期:2006-06-01 00:00:00

  • Numerical validation of MR-measurement-integrated simulation of blood flow in a cerebral aneurysm.

    abstract::This study proposes magnetic resonance (MR)-measurement-integrated (MR-MI) simulation, in which the difference between the computed velocity field and the phase-contrast MRI measurement data is fed back to the numerical simulation. The computational accuracy and the fundamental characteristics, such as steady characte...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-009-9689-y

    authors: Funamoto K,Suzuki Y,Hayase T,Kosugi T,Isoda H

    更新日期:2009-06-01 00:00:00

  • Accuracy of Functional and Predictive Methods to Calculate the Hip Joint Center in Young Non-pathologic Asymptomatic Adults with Dual Fluoroscopy as a Reference Standard.

    abstract::Predictions from biomechanical models of gait may be sensitive to joint center locations. Most often, the hip joint center (HJC) is derived from locations of reflective markers adhered to the skin. Here, predictive techniques use regression equations of pelvic anatomy to estimate the HJC, whereas functional methods tr...

    journal_title:Annals of biomedical engineering

    pub_type: 临床试验,杂志文章

    doi:10.1007/s10439-015-1522-1

    authors: Fiorentino NM,Kutschke MJ,Atkins PR,Foreman KB,Kapron AL,Anderson AE

    更新日期:2016-07-01 00:00:00

  • Impact of Pulmonary Venous Inflow on Cardiac Flow Simulations: Comparison with In Vivo 4D Flow MRI.

    abstract::Blood flow simulations are making their way into the clinic, and much attention is given to estimation of fractional flow reserve in coronary arteries. Intracardiac blood flow simulations also show promising results, and here the flow field is expected to depend on the pulmonary venous (PV) flow rates. In the absence ...

    journal_title:Annals of biomedical engineering

    pub_type: 临床试验,杂志文章

    doi:10.1007/s10439-018-02153-5

    authors: Lantz J,Gupta V,Henriksson L,Karlsson M,Persson A,Carlhäll CJ,Ebbers T

    更新日期:2019-02-01 00:00:00

  • Development of a Platform for Studying 3D Astrocyte Mechanobiology: Compression of Astrocytes in Collagen Gels.

    abstract::Glaucoma is a common optic neuropathy characterized by retinal ganglion cell death. Elevated intraocular pressure (IOP), a key risk factor for glaucoma, leads to significant biomechanical deformation of optic nerve head (ONH) cells and tissues. ONH astrocytes respond to this deformation by transforming to a reactive, ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-017-1967-5

    authors: Mulvihill JJE,Raykin J,Snider EJ,Schildmeyer LA,Zaman I,Platt MO,Kelly DJ,Ethier CR

    更新日期:2018-02-01 00:00:00

  • A Fluorescence Sensing Method with Reduced DNA Typing and Low-Cost Instrumentation for Detection of Sample Tampering Cases in Urinalysis.

    abstract::This work presents a method to unequivocally detect urine sample tampering in cases where integrity of the sample needs to be verified prior to urinalysis. The technique involves the detection of distinct patterns of a triplex short tandem repeats system in DNA extracted from human urine. The analysis is realized with...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-019-02386-y

    authors: Pires NMM,Dong T,Yang Z,Santos SMB

    更新日期:2020-02-01 00:00:00

  • In vitro temperature map of cardiac ablation demonstrates the effect of flow on lesion development.

    abstract::This paper presents an in vitro temperature mapping study of bovine cardiac tissue during radiofrequency ablation. The objectives were to: (i) develop a technique for measuring the spatial and temporal temperature distribution in the tissue and in the blood during ablation, and (ii) use the temperature measurements to...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1310218

    authors: Jain MK,Wolf PD

    更新日期:2000-09-01 00:00:00

  • Computational tools for quantitative breast morphometry based on 3D scans.

    abstract::Quantitative analysis of breast morphometry is critical to breast plastic surgery. Recently, three-dimensional (3D) photography has emerged as a strong new alternative for breast morphometry analysis in comparison to other existing techniques. 3D photography enables the capture of the entire breast surface topology vi...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-9971-z

    authors: Chen D,Chittajallu DR,Passalis G,Kakadiaris IA

    更新日期:2010-05-01 00:00:00

  • The effect of blood flow on the material properties of bone.

    abstract::This project was undertaken to establish if the integral circulation had any effects upon the mechanical behavior of bone. The influence of blood flow in the rabbit tibia on the strain induced at the bone surface when under load was assessed. Recordings were taken from three adult and three immature New Zealand White ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02390377

    authors: McDonald F,Pitt Ford TR

    更新日期:1994-03-01 00:00:00

  • Prediction of hip fracture can be significantly improved by a single biomedical indicator.

    abstract::Femoral neck fractures are a relevant clinical and social problem. The aim of this study was to improve the prediction of patients at-risk of femoral neck fracture with respect to the current densitometric-based methods. In particular, finite element models were used to assess the prediction accuracy obtained by combi...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1495866

    authors: Testi D,Viceconti M,Cappello A,Gnudi S

    更新日期:2002-06-01 00:00:00

  • Regional distribution of aerosol deposition in rat lungs using magnetic resonance imaging.

    abstract::The toxic or therapeutic effect of an inhaled aerosol is highly dependent upon the site and extent of deposition in the lung. A novel MRI-based method was used to quantify the spatial distribution of particles in the rat lung. Rats were exposed to 0.95 μm-diameter iron oxide particles in a controlled manner (N = 6) or...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-013-0745-2

    authors: Oakes JM,Scadeng M,Breen EC,Prisk GK,Darquenne C

    更新日期:2013-05-01 00:00:00

  • Validation of Shoulder Response of Human Body Finite-Element Model (GHBMC) Under Whole Body Lateral Impact Condition.

    abstract::In previous shoulder impact studies, the 50th-percentile male GHBMC human body finite-element model was shown to have good biofidelity regarding impact force, but under-predicted shoulder deflection by 80% compared to those observed in the experiment. The goal of this study was to validate the response of the GHBMC M5...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1546-6

    authors: Park G,Kim T,Panzer MB,Crandall JR

    更新日期:2016-08-01 00:00:00

  • An artificial neural network approach to the predictive modeling of tensile force during renal suturing.

    abstract::Further understanding of the mechanical deformation and tear behavior of kidney during suturing helps to enhance surgical task execution that requires fine suture manipulation. This paper aims to develop a model to describe the relationship between the tensile force acting on suture line and the resulted kidney deform...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-012-0722-1

    authors: Yu D,Qing Y,Jianxun Z,Jun D

    更新日期:2013-04-01 00:00:00

  • Hydraulic Conductivity of Smooth Muscle Cell-Initiated Arterial Cocultures.

    abstract::The purpose of the study was to examine the effects of arterial coculture conditions on the transport properties of several in vitro endothelial cell (EC)-smooth muscle cell (SMC)-porous filter constructs in which SMC were grown to confluence first and then EC were inoculated. This order of culturing simulates the env...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1421-5

    authors: Mathura RA,Russell-Puleri S,Cancel LM,Tarbell JM

    更新日期:2016-05-01 00:00:00

  • A COVID-19 Airway Management Innovation with Pragmatic Efficacy Evaluation: The Patient Particle Containment Chamber.

    abstract::The unique resource constraints, urgency, and virulence of the coronavirus disease 2019 pandemic has sparked immense innovation in the development of barrier devices to protect healthcare providers from infectious airborne particles generated by patients during airway management interventions. Of the existing devices,...

    journal_title:Annals of biomedical engineering

    pub_type: 社论

    doi:10.1007/s10439-020-02599-6

    authors: Maloney LM,Yang AH,Princi RA,Eichert AJ,Hébert DR,Kupec TV,Mertz AE,Vasyltsiv R,Vijaya Kumar TM,Walker GJ,Peralta EJ,Hoffman JL,Yin W,Page CR

    更新日期:2020-10-01 00:00:00

  • A review of the role of the partial pressure of carbon dioxide in mechanically loaded tissues: the canary in the cage singing in tune with the pressure ulcer mantra.

    abstract::Pressure ulcers (PUs) can occur in any situations where people are subjected to non-uniform distribution of pressure over a prolonged period. They can have devastating effects on the patients' well-being and in extreme conditions can prove fatal. In addition to traditional wisdom implicating mechanically induced ischa...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/s10439-014-1233-z

    authors: Mirtaheri P,Gjøvaag T,Worsley PR,Bader DL

    更新日期:2015-02-01 00:00:00

  • On the Compressibility of Arterial Tissue.

    abstract::Arterial tissue is commonly assumed to be incompressible. While this assumption is convenient for both experimentalists and theorists, the compressibility of arterial tissue has not been rigorously investigated. In the current study we present an experimental-computational methodology to determine the compressibility ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1417-1

    authors: Nolan DR,McGarry JP

    更新日期:2016-04-01 00:00:00

  • Fluid shifts due to microgravity and their effects on bone: a review of current knowledge.

    abstract::Bone loss during long-term space flight is potentially a significant problem. Bone mineral density measurements show that bone is lost at a rate of about 1% per month from the lumbar spine, and 1.5% per month from the hip. Bone density changes are not uniform throughout the skeleton, and there is accumulating evidence...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/s10439-005-8967-6

    authors: McCarthy ID

    更新日期:2005-01-01 00:00:00

  • Fluid dynamics of gas exchange in high-frequency oscillatory ventilation: in vitro investigations in idealized and anatomically realistic airway bifurcation models.

    abstract::The objective of this work is to develop understanding of the local fluid dynamic mechanisms that underpin gas exchange in high-frequency oscillatory ventilation (HFOV). The flow field during HFOV was investigated experimentally using particle image velocimetry in idealized and realistic models of a single bifurcation...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-008-9557-1

    authors: Heraty KB,Laffey JG,Quinlan NJ

    更新日期:2008-11-01 00:00:00

  • Analyzing Remodeling of Cardiac Tissue: A Comprehensive Approach Based on Confocal Microscopy and 3D Reconstructions.

    abstract::Microstructural characterization of cardiac tissue and its remodeling in disease is a crucial step in many basic research projects. We present a comprehensive approach for three-dimensional characterization of cardiac tissue at the submicrometer scale. We developed a compression-free mounting method as well as labelin...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1465-6

    authors: Seidel T,Edelmann JC,Sachse FB

    更新日期:2016-05-01 00:00:00

  • Real-Time linux dynamic clamp: a fast and flexible way to construct virtual ion channels in living cells.

    abstract::We describe a system for real-time control of biological and other experiments. This device, based around the Real-Time Linux operating system, was tested specifically in the context of dynamic clamping, a demanding real-time task in which a computational system mimics the effects of nonlinear membrane conductances in...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1408929

    authors: Dorval AD,Christini DJ,White JA

    更新日期:2001-10-01 00:00:00

  • Hierarchical CT to Ultrasound Registration of the Lumbar Spine: A Comparison with Other Registration Methods.

    abstract::Three-dimensional (3D) measurement of the spine can provide important information for functional, developmental, diagnostic, and treatment-effect evaluations. However, existing measurement techniques are either 2-dimensional, highly invasive, or involve a high radiation dose, prohibiting their widespread and repeated ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-016-1599-1

    authors: Koo TK,Kwok WE