Intracellular trafficking considerations in the development of natural ligand-drug molecular conjugates for cancer.

Abstract:

:Overexpressed receptors, characteristic of many cancers, have been targeted by various researchers to achieve a more specific treatment for cancer. A common approach is to use the natural ligand for the overexpressed receptor as a cancer-targeting agent which can deliver a chemically or genetically conjugated toxic molecule. However, it has been found that the therapeutic efficacy of such ligand-drug molecular conjugates can be limited, since they naturally follow the intracellular trafficking pathways of the endogenous ligands. Therefore, a thorough understanding of the intracellular trafficking properties of these ligands can lead to novel design criteria for engineering ligands to be more effective drug carriers. This review presents a few commonly used ligand/receptor systems where intracellular trafficking considerations can potentially improve the therapeutic efficacy of the ligand-drug molecular conjugates.

journal_name

Ann Biomed Eng

authors

Yoon DJ,Liu CT,Quinlan DS,Nafisi PM,Kamei DT

doi

10.1007/s10439-011-0280-y

subject

Has Abstract

pub_date

2011-04-01 00:00:00

pages

1235-51

issue

4

eissn

0090-6964

issn

1573-9686

journal_volume

39

pub_type

杂志文章,评审
  • Sensitivity analysis of an image-based solid tumor computational model with heterogeneous vasculature and porosity.

    abstract::An MR image-based computational model of a murine KHT sarcoma is presented that allows the calculation of plasma fluid and solute transport within tissue. Such image-based models of solid tumors may be used to optimize patient-specific therapies. This model incorporates heterogeneous vasculature and tissue porosity to...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-011-0349-7

    authors: Pishko GL,Astary GW,Mareci TH,Sarntinoranont M

    更新日期:2011-09-01 00:00:00

  • Stress relaxation preconditioning of porcine aortic valves.

    abstract::In uniaxial tensile testing, load preconditioning is used to generate repeatable load/elongation curves and set a "reference state" for subsequent tensile tests. We have observed however, that for porcine aortic valve (PAV) tissues, preconditioning does not lead to repeatable stress relaxation curves. We thus investig...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1023/b:abme.0000019176.49650.19

    authors: Carew EO,Garg A,Barber JE,Vesely I

    更新日期:2004-04-01 00:00:00

  • Hemodynamics in a Pediatric Ascending Aorta Using a Viscoelastic Pediatric Blood Model.

    abstract::Congenital heart disease is the leading cause of infant death in the United States with over 36,000 newborns affected each year. Despite this growing problem there are few mechanical circulatory support devices designed specifically for pediatric and neonate patients. Previous research has been done investigating pedi...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1370-z

    authors: Good BC,Deutsch S,Manning KB

    更新日期:2016-04-01 00:00:00

  • Effect of extracellular potassium accumulation on muscle fiber conduction velocity: a simulation study.

    abstract::A progressive reduction in muscle fiber conduction velocity is typically observed during fatiguing muscle contraction. Although the exact causes of the conduction velocity decrease have not yet been fully established, increasing evidence suggests that changes in extracellular potassium concentration may be largely res...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-009-9756-4

    authors: Fortune E,Lowery MM

    更新日期:2009-10-01 00:00:00

  • An improved Morris Water Maze tracking algorithm for psychophysical studies.

    abstract::An algorithm to track a rat swimming in a Morris Water Maze has been developed. The system is automatically configured to any pool and relative suitable light conditions. It tracks the rat's position and head pose 10 times per second. The output data is displayed in a bitmap and also in a text file. The system was tes...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/b:abme.0000036650.32345.b6

    authors: Hval ES,Barrett SF,Wilcox M,Bailey TA

    更新日期:2004-08-01 00:00:00

  • Surfactant properties differentially influence intravascular gas embolism mechanics.

    abstract::Gas bubble motion in a blood vessel causes temporal and spatial gradients of shear stress at the cell surface lining the vessel wall as the bubble approaches the cell, moves over it and passes it by. Rapid reversals occur in the sign of the shear stress imparted to the cell surface during this motion. These may result...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-0120-5

    authors: Swaminathan TN,Ayyaswamy PS,Eckmann DM

    更新日期:2010-12-01 00:00:00

  • The effect of visual and sensory performance on head impact biomechanics in college football players.

    abstract::The development of prevention strategies is critical to address the rising prevalence of sport-related concussions. Visual and sensory performance may influence an individual's ability to interpret environmental cues, anticipate opponents' actions, and create appropriate motor responses limiting the severity of an imp...

    journal_title:Annals of biomedical engineering

    pub_type: 临床试验,杂志文章

    doi:10.1007/s10439-013-0881-8

    authors: Harpham JA,Mihalik JP,Littleton AC,Frank BS,Guskiewicz KM

    更新日期:2014-01-01 00:00:00

  • Spectral analysis of Doppler flow velocity signals: assessment of objectives, methods, and interpretation.

    abstract::The objective of this paper is to review the theoretical basis and clinical application of electrical impedance plethysmography in the noninvasive evaluation of peripheral arterial and venous disease. Theoretical, experimental and clinical studies have not demonstrated a direct relationship between electrical impedanc...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02410294

    authors: Zuech PE,Cobbold RS,Johnston KW,Kassam M

    更新日期:1984-01-01 00:00:00

  • Binary segmentation masks can improve intrasubject registration accuracy of bone structures in CT images.

    abstract::Registration of bone structures is a common problem in medical research as well as in clinical applications. Intrasubject rigid 3D monomodality registration of segmented bone structures of CT images and multimodality registration of muMR and segmented muCT bone images were performed with the multiresolution intensity-...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-9981-x

    authors: Museyko O,Eisa F,Hess A,Schett G,Kalender WA,Engelke K

    更新日期:2010-07-01 00:00:00

  • Evaluation of stochastic differential equation approximation of ion channel gating models.

    abstract::Fox and Lu derived an algorithm based on stochastic differential equations for approximating the kinetics of ion channel gating that is simpler and faster than "exact" algorithms for simulating Markov process models of channel gating. However, the approximation may not be sufficiently accurate to predict statistics of...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-009-9635-z

    authors: Bruce IC

    更新日期:2009-04-01 00:00:00

  • Fetal Transcatheter Trileaflet Heart Valve Hemodynamics: Implications of Scaling on Valve Mechanics and Turbulence.

    abstract::The scarcity of data available on the best approach for pulmonary fetal valve replacement or implantation necessitate an investigation on whether practices using adult transcatheter valves could be translated to fetal applications. The objective of this study is to evaluate the hemodynamic characteristics and the turb...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02475-3

    authors: Hatoum H,Gooden S,Heitkemper M,Blum KM,Zakko J,Bocks M,Yi T,Wu YL,Wang Y,Breuer CK,Dasi LP

    更新日期:2020-06-01 00:00:00

  • Analog electrical model of the coronary circulation in case of multiple revascularizations.

    abstract::In this work, we propose an analog electrical model of the coronary circulation for patients with obstructive disease undergoing revascularization. In this clinical situation, the collateral circulation to the occluded artery is difficult to ascertain via preoperative measurements and well-developed collaterals might ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-008-9500-5

    authors: Maasrani M,Verhoye JP,Corbineau H,Drochon A

    更新日期:2008-07-01 00:00:00

  • Are DXA/aBMD and QCT/FEA Stiffness and Strength Estimates Sensitive to Sex and Age?

    abstract::Dual X-ray absorptiometry (DXA) measures areal bone mineral density (aBMD) by simplifying a complex 3D bone structure to a 2D projection and is not equally effective for explaining fracture strength in women and men. Unlike DXA, subject-specific quantitative computed tomography-based finite element analysis (QCT/FEA) ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-017-1914-5

    authors: Rezaei A,Giambini H,Rossman T,Carlson KD,Yaszemski MJ,Lu L,Dragomir-Daescu D

    更新日期:2017-12-01 00:00:00

  • Tracking of Drug Release and Material Fate for Naturally Derived Omega-3 Fatty Acid Biomaterials.

    abstract::In vitro and in vivo studies were conducted on omega-3 fatty acid-derived biomaterials to determine their utility as an implantable material for adhesion prevention following soft tissue hernia repair and as a means to allow for the local delivery of antimicrobial or antibiofilm agents. Naturally derived biomaterials ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1489-y

    authors: Faucher KM,Artzi N,Beck M,Beckerman R,Moodie G,Albergo T,Conroy S,Dale A,Corbeil S,Martakos P,Edelman ER

    更新日期:2016-03-01 00:00:00

  • Endothelial gene expression in regions of defined shear exposure in the porcine iliac arteries.

    abstract::The effect of hemodynamic shear stress on endothelial gene expression was investigated in the porcine iliac arteries. A novel statistical approach was applied to computational fluid dynamics simulations of the iliac artery flow field to identify three anatomical regions likely to experience high, medium, and low level...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-0030-6

    authors: LaMack JA,Himburg HA,Zhang J,Friedman MH

    更新日期:2010-07-01 00:00:00

  • Investigation of the Sequential Actions of Doxorubicin and p53 on Tumor Cell Growth Via Branched Polyethylenimine-β-cyclodextrin Conjugates.

    abstract::The combination of gene therapy and chemotherapy has showed increased therapeutic efficacy in the treatment of cancers, but it is not well investigated about the actual coordination pattern between therapeutic gene and chemical drug. In this work, p53/BPEI-β-CD/AD-dox complex was fabricated and employed to investigate...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-016-1627-1

    authors: Xie B,Peng J,Wang S,Zhang X,Nie H

    更新日期:2016-11-01 00:00:00

  • Human saphenous vein coronary artery bypass graft morphology, geometry and hemodynamics.

    abstract::Coronary artery bypass graft (CABG) failure has been linked to graft hemodynamics, in particular wall shear stress. This study characterizes the morphology, geometry and wall shear stress patterns in human CABGs. The intimal thickness (IT) in 49 human saphenous vein CABGs was measured by digital light microscopy. The ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-005-1732-z

    authors: Leask RL,Butany J,Johnston KW,Ethier CR,Ojha M

    更新日期:2005-03-01 00:00:00

  • Use of pseudorandom noise in studies of auditory evoked potentials.

    abstract::The extent to which sensorineural systems such as the auditory system are nonlinear depends on the type of stimulus that is used, and the part of the system from which recordings are made. An estimate of the first-order Wiener kernel of the evoked response from the inferior colliculus to amplitude-modulated tones and ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02367379

    authors: Møller AR,Angelo RM

    更新日期:1988-01-01 00:00:00

  • Constitutive modeling of pia-arachnoid complex.

    abstract::The pia-arachnoid complex (PAC) covering the brain plays an important role in the mechanical response of the brain during impact or inertial loading. Recent studies have revealed the complicated material behavior of the PAC. In this study, the nonlinear viscoelastic, transversely isotropic material properties of the P...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-013-0948-6

    authors: Jin X,Mao H,Yang KH,King AI

    更新日期:2014-04-01 00:00:00

  • Mechanical behavior of vascular smooth muscle in cylindrical segments of arteries in vitro.

    abstract::Vascular smooth muscle mechanics have been studied in vitro in cylindrical segments of dog carotid artery, human internal mammary artery, and human saphenous vein. Such cylindrical preparations maintain normal vessel geometry and also permit correlation of mechanical phenomena with transmural pressure. These studies s...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02363919

    authors: Dobrin PB

    更新日期:1984-01-01 00:00:00

  • Characterizing the variability of system kernel and input estimates.

    abstract::The identification of the input to, or kernels of, a system using nonparametric representations and least-squares estimation is becoming increasingly popular. Nonparametric representations avoid making a priori assumptions about the input or having detailed knowledge about the system, and only need to guarantee known ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.110

    authors: Verotta D

    更新日期:1998-09-01 00:00:00

  • Detecting Aortic Valve-Induced Abnormal Flow with Seismocardiography and Cardiac MRI.

    abstract::Cardiac MRI (CMR) techniques offer non-invasive visualizations of cardiac morphology and function. However, imaging can be time-consuming and complex. Seismocardiography (SCG) measures physical vibrations transmitted through the chest from the beating heart and pulsatile blood flow. SCG signals can be acquired quickly...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02491-3

    authors: Johnson EMI,Heller JA,Garcia Vicente F,Sarnari R,Gordon D,McCarthy PM,Barker AJ,Etemadi M,Markl M

    更新日期:2020-06-01 00:00:00

  • Investigating tendon fascicle structure-function relationships in a transgenic-age mouse model using multiple regression models.

    abstract::Proper replacement or repair of damaged tendons or ligaments requires functionally engineered tissue that mimics their native mechanical properties. While tendon structure-function relationships are generally assumed, there exists little quantitative evidence of the roles of distinct tendon components in tendon functi...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1023/b:abme.0000032455.78459.56

    authors: Robinson PS,Lin TW,Jawad AF,Iozzo RV,Soslowsky LJ

    更新日期:2004-07-01 00:00:00

  • Mechanical analysis of atherosclerotic plaques based on optical coherence tomography.

    abstract::Finite element analysis is a powerful tool for investigating the biomechanics of atherosclerosis and has thereby provided an improved understanding of acute myocardial infarction. Structural analysis of arterial walls is traditionally performed using geometry contours derived from histology. In this paper we demonstra...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/b:abme.0000049034.75368.4a

    authors: Chau AH,Chan RC,Shishkov M,MacNeill B,Iftimia N,Tearney GJ,Kamm RD,Bouma BE,Kaazempur-Mofrad MR

    更新日期:2004-11-01 00:00:00

  • An experimental evaluation of the use of an ensemble average for the calculation of turbulence in pulsatile flow.

    abstract::A comparison was made between turbulence calculated by subtracting an ensemble average from the instantaneous velocity and calculations made with a high pass digital filter. Velocity was measured with a laser Doppler anemometer in vitro in the region of a normal porcine aortic valve and in patients with a hot film ane...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02584215

    authors: Walburn FJ,Sabbah HN,Stein PD

    更新日期:1983-01-01 00:00:00

  • Lensfree optofluidic microscopy and tomography.

    abstract::Microfluidic devices aim at miniaturizing, automating, and lowering the cost of chemical and biological sample manipulation and detection, hence creating new opportunities for lab-on-a-chip platforms. Recently, optofluidic devices have also emerged where optics is used to enhance the functionality and the performance ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/s10439-011-0385-3

    authors: Bishara W,Isikman SO,Ozcan A

    更新日期:2012-02-01 00:00:00

  • Sustained Efficacy and Arterial Drug Retention by a Fast Drug Eluting Cross-Linked Fatty Acid Coronary Stent Coating.

    abstract::The long held assumption that sustained drug elution from stent coatings over weeks to months is imperative for clinical efficacy has limited the choice for stent coating materials. We developed and evaluated an omega-3 fatty acid (O3FA) based stent coating that is 85% absorbed and elutes 97% of its Sirolimus analog (...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1435-z

    authors: Artzi N,Tzafriri AR,Faucher KM,Moodie G,Albergo T,Conroy S,Corbeil S,Martakos P,Virmani R,Edelman ER

    更新日期:2016-02-01 00:00:00

  • Reporter Scaffolds for Clinically Relevant Cell Transplantation Studies.

    abstract::There are a number of cell therapies that are either in clinical trials or moving toward clinical trials, particularly for diseases of the retina. One of the challenges with cell therapies is tracking the status of cells over time. Genetic manipulation can facilitate this, but it can limit the clinical application of ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-019-02393-z

    authors: Bolger M,Groynom R,Bogie K,Lavik E

    更新日期:2020-07-01 00:00:00

  • Correction to: A High-Precision and Miniature Fiber Bragg Grating-Based Force Sensor for Tissue Palpation During Minimally Invasive Surgery.

    abstract::The second equation in the section "Definition of Objective Functions and Constraints" was corrected to fix a mismatch between the PDF and HTML versions of the article. ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,已发布勘误

    doi:10.1007/s10439-019-02413-y

    authors: Lv C,Wang S,Shi C

    更新日期:2020-01-01 00:00:00

  • Predicting the responses of mechanoreceptor neurons to physiological inputs by nonlinear system identification.

    abstract::The nonlinear dynamic properties of action potential encoding were studied in mechanosensory neurons innervating the slits of a slit-sense organ in the tropical wandering spider, Cupiennius salei. The organ contains two types of neurons that are morphologically similar but have different dynamic properties. Type A neu...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1355278

    authors: French AS,Sekizawa SI,Höger U,Torkkeli PH

    更新日期:2001-03-01 00:00:00