Abstract:
:Proper replacement or repair of damaged tendons or ligaments requires functionally engineered tissue that mimics their native mechanical properties. While tendon structure-function relationships are generally assumed, there exists little quantitative evidence of the roles of distinct tendon components in tendon function. Previous work has used linear correlations to assess the independent, univariate effects of one structural or one biochemical variable on mechanics. The current study's objective was to simultaneously and rigorously evaluate the relative contributions of seven different structural and compositional variables in predicting tissue mechanical properties through the use of multiple regression statistical models. Structural, biochemical, and mechanical analysis were all performed on tail tendon fascicles from different groups of transgenic mice, which provide a reproducible, noninvasive, in vivo model of changes in tendon structure and composition. Interestingly, glycosaminoglycan (GAG) content was observed to be the strongest predictor of mechanical properties. GAG content was also well correlated with collagen content and mean collagen fibril diameter. Collagen fibril area fraction was a significant predictor only of material properties. Therefore, in a large multivariate model, GAG content was the largest predictor of mechanical properties, perhaps both through direct influence and indirectly through its correlation with collagen content and fibril structure.
journal_name
Ann Biomed Engjournal_title
Annals of biomedical engineeringauthors
Robinson PS,Lin TW,Jawad AF,Iozzo RV,Soslowsky LJdoi
10.1023/b:abme.0000032455.78459.56subject
Has Abstractpub_date
2004-07-01 00:00:00pages
924-31issue
7eissn
0090-6964issn
1573-9686journal_volume
32pub_type
杂志文章abstract::The multiphoton fluorescence recovery after photobleaching (MP-FRAP) technique has been developed to measure the three-dimensional (3D) solute diffusion within biological systems. However, current 3D MP-FRAP models are based on isotropic diffusion and spatial domain analysis. The 3D anisotropic diffusion and frequency...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-013-0939-7
更新日期:2014-03-01 00:00:00
abstract::When cells and the matrix of a tissue remodel, the mechanical properties of the tissue do change. The mechanical properties are expressed by constitutive equations. In this article the remodeling of the constitutive equation of the pulmonary artery is studied. The remodeling was induced in a rat breathing a gas whose ...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1114/1.1380417
更新日期:2001-01-01 00:00:00
abstract::Biochemical stimulation was applied in combination with cyclic mechanical strain to engineered vascular constructs made of isolated smooth muscle cells in a three-dimensional (3D) collagen type 1 matrix. Platelet-derived growth factor (PDGF) and transforming growth factor beta (TGF-beta) were added exogenously to the ...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1114/1.1558031
更新日期:2003-04-01 00:00:00
abstract::User preferences need to be taken into account in order to be able to design devices that will gain acceptance both in a clinical and home setting. Sensor systems become redundant if patients or clinicians do not want to work with them. The aim of this systematic review was to determine both patients' and clinicians' ...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章,评审
doi:10.1007/s10439-011-0339-9
更新日期:2011-09-01 00:00:00
abstract::In an effort to share best practices in undergraduate engineering design education, we describe the origin, evolution and the current status of the undergraduate biomedical engineering design team program at Johns Hopkins University. Specifically, we describe the program and judge the quality of the pedagogy by relati...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-013-0781-y
更新日期:2013-09-01 00:00:00
abstract::The long held assumption that sustained drug elution from stent coatings over weeks to months is imperative for clinical efficacy has limited the choice for stent coating materials. We developed and evaluated an omega-3 fatty acid (O3FA) based stent coating that is 85% absorbed and elutes 97% of its Sirolimus analog (...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-015-1435-z
更新日期:2016-02-01 00:00:00
abstract::Nanomedicine (a division of nanotechnology) is an interdisciplinary research field incorporating biology, chemistry, engineering and medicine with the intention to improve disease prevention, diagnosis, and treatment. Specifically, there have been great strides made in using nanomedicine to enhance the functions of ce...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章,评审
doi:10.1007/s10439-009-9722-1
更新日期:2009-10-01 00:00:00
abstract::The influence of scaffold compliance on blood vessel tissue engineering remains unclear and compliance mismatch issues are important to an in vivo tissue-engineering approach. We have designed and constructed a modular bioreactor system that is capable of imparting pulsatile fluid flow while simultaneously measuring v...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-007-9304-z
更新日期:2007-08-01 00:00:00
abstract::Lung cancer patients often suffer from severe airway stenosis, the symptoms of which can be relieved by the implantation of stents. Different respiratory stents are commercially available, but the impact of their mechanical performance on tissue responses is not well understood. Two novel laser-cut and hand-braided ni...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-019-02278-1
更新日期:2019-08-01 00:00:00
abstract::Children with cerebral palsy frequently experience foot dragging and tripping during walking due to a lack of adequate knee flexion in swing (stiff-knee gait). Stiff-knee gait is often accompanied by an overly flexed knee during stance (crouch gait). Studies on stiff-knee gait have mostly focused on excessive knee mus...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-010-9952-2
更新日期:2010-04-01 00:00:00
abstract::An endovascular technique using a stent has been developed and successfully applied in the treatment of wide neck aneurysms. A stent can facilitate thrombosis in the aneurysm pouch while maintaining biocompatible passage of the parent artery. Insertion of the stent changes the flow characteristics inside the aneurysm ...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1114/1.1500406
更新日期:2002-07-01 00:00:00
abstract::A recent analytical solution of the three-dimensional Stokes flow through a bumpy tube predicts that for a given bump area, there exists an optimal circumferential wavenumber which minimizes flow resistance. This study uses measurements of microvessel endothelial cell morphology to test whether this prediction holds i...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-008-9467-2
更新日期:2008-04-01 00:00:00
abstract::Cell migration paths of mammary epithelial cells (expressing different versions of the promigratory tyrosine kinase receptor Her2/Neu) were analyzed within a bimodal framework that is a generalization of the run-and-tumble description applicable to bacterial migration. The mammalian cell trajectories were segregated i...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-008-9592-y
更新日期:2009-01-01 00:00:00
abstract::In this study, we introduce the fast wavelet transform as a method for characterizing maturational changes in electrocortical activity, respiratory activity, and blood pressure in fetal lambs in early (110-122 days), mid (123-135 days), and late (136-144 days) third trimester (term 145 days). Each recording was 2 hr i...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/BF02584457
更新日期:1995-09-01 00:00:00
abstract::Congenital heart disease is the leading cause of infant death in the United States with over 36,000 newborns affected each year. Despite this growing problem there are few mechanical circulatory support devices designed specifically for pediatric and neonate patients. Previous research has been done investigating pedi...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-015-1370-z
更新日期:2016-04-01 00:00:00
abstract::While bone mineral density has been traditionally used to quantify fracture risk for individuals with spinal cord injuries, recent studies are including engineering measurements such as section modulus and cross sectional moment of inertia. These are almost exclusively calculated by peripheral QCT scanners which, unli...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-017-1796-6
更新日期:2017-05-01 00:00:00
abstract::We have studied the interaction of high frequency jet ventilation with cardiovascular pressures and flows. Results in dogs show that the amplitude of all intrathoracic pressures and flows fluctuate with a frequency equal to the difference between the heart rate and ventilator rate. The magnitude of this amplitude vari...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/BF02584287
更新日期:1987-01-01 00:00:00
abstract::Organ models are used for planning and simulation of operations, developing new surgical instruments, and training purposes. There is a substantial demand for in vitro organ phantoms, especially in urological surgery. Animal models and existing simulator systems poorly mimic the detailed morphology and the physical pr...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-016-1757-5
更新日期:2017-04-01 00:00:00
abstract::This paper presents two related methods for registering an image of an anatomical object with data from sensors arranged on the object. One method is described with reference to a test case involving a rectangular electrode plaque disposed on a heart surface, which is imaged with MRI. Data from the electrodes is fused...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-007-9350-6
更新日期:2007-10-01 00:00:00
abstract::Double-exposure holographic interferometry is a contactless whole-field method. Dimensional changes are visualized as a series of interference fringes overlaid on the holographic image of the femur, where each fringe represents 0.316 micron (half the wavelength of the laser light) of motion. Interferograms for intact ...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/BF02364168
更新日期:1987-01-01 00:00:00
abstract::High energy laser has emerged to be an important surgical tool in medical technology. However, the application of laser energy to drill or cut a bone is still in an experimental state. In order to estimate the adequacy of laser heating of bone surface and at the same time minimize the damage to the bone tissue, we dev...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/BF02363565
更新日期:1987-01-01 00:00:00
abstract::The pericellular matrix (PCM) is a region of tissue that surrounds chondrocytes in articular cartilage and together with the enclosed cells is termed the chondron. Previous studies suggest that the mechanical properties of the PCM, relative to those of the chondrocyte and the extracellular matrix (ECM), may significan...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-005-4479-7
更新日期:2005-10-01 00:00:00
abstract::Conventional histologic methods provide valuable information regarding the physical nature of damage in fatigue-loaded tendons, limited to thin, two-dimensional sections. We introduce an imaging method that characterizes tendon microstructure three-dimensionally and develop quantitative, spatial measures of damage for...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-010-9976-7
更新日期:2010-05-01 00:00:00
abstract::"Smart" drug delivery systems should be selective and effective to ensure drug administration at the right time, at the right dosage, and anywhere in the body. Among the several administration routes and delivery systems that have been proposed, one of the most effective and promising is based on microfabricated parti...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1023/b:abme.0000030255.36748.d3
更新日期:2004-06-01 00:00:00
abstract::Instrumentation systems for breath-to-breath analysis of respiratory gas exchange have been faulted by phase lags between various flow and composition signals and by difficulties in gathering and processing large amounts of data. The system described here represents an attempt to overcome these problems. Phase delays ...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/BF02367493
更新日期:1983-01-01 00:00:00
abstract::This study presents a novel approach to modeling the electrocardiogram (ECG): the Gaussian pulse decomposition. Constituent waves of the ECG are decomposed into and represented by Gaussian pulses using an iterative algorithm: the chip away decomposition (ChAD) algorithm. At each iteration, a nonlinear minimization met...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/BF02648039
更新日期:1997-03-01 00:00:00
abstract::Local hemodynamics are an important factor in atherosclerosis, from the development of early lesions, to the assessment of stroke risk, to determining the ultimate fate of a mature plaque. Until recently, our understanding of arterial fluid dynamics and their relationship to atherosclerosis was limited by the use of i...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章,评审
doi:10.1114/1.1467679
更新日期:2002-04-01 00:00:00
abstract::Spike discharge patterns showing intrinsic oscillations (IOs) have been reported in units in the dorsal cochlear nucleus (DCN) of the decerebrate cat. These oscillations are related to the regularity of a unit's discharge rate and may be important for pitch perception. A DCN unit's regularity can be affected by severa...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1114/1.96
更新日期:1998-05-01 00:00:00
abstract::Polycrystalline silicon (poly-Si) micromechanical structures can be made by selectively etching an underlying sacrificial oxide layer. Advantages of this micromachining technique are its simplicity and compatibility with conventional integrated-circuit processing. Compressive internal stress in poly-Si films constrain...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/BF02584269
更新日期:1986-01-01 00:00:00
abstract::The nonlinear dynamic properties of action potential encoding were studied in mechanosensory neurons innervating the slits of a slit-sense organ in the tropical wandering spider, Cupiennius salei. The organ contains two types of neurons that are morphologically similar but have different dynamic properties. Type A neu...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1114/1.1355278
更新日期:2001-03-01 00:00:00