Image-Based Simulations Show Important Flow Fluctuations in a Normal Left Ventricle: What Could be the Implications?

Abstract:

:Intra-cardiac flow has been explored for decades but there is still no consensus on whether or not healthy left ventricles (LV) may harbour turbulent-like flow despite its potential physiological and clinical relevance. The purpose of this study is to elucidate if a healthy LV could harbour flow instabilities, using image-based computational fluid dynamics (CFD). 35 cardiac cycles were simulated in a patient-specific left heart model obtained from cardiovascular magnetic resonance (CMR). The model includes the valves, atrium, ventricle, papillary muscles and ascending aorta. We computed phase-averaged flow patterns, fluctuating kinetic energy (FKE) and associated frequency components. The LV harbours disturbed flow during diastole with cycle-to-cycle variations. However, phase-averaged velocity fields much resemble those of CMR measurements and usually reported CFD results. The peak FKE value occurs during the E wave deceleration and reaches 25% of the maximum phase-averaged flow kinetic energy. Highest FKE values are predominantly located in the basal region and their frequency content reach more than 200 Hz. This study suggests that high-frequency flow fluctuations in normal LV may be common, implying deficiencies in the hypothesis usually made when computing cardiac flows and highlighting biases when deriving quantities from velocity fields measured with CMR.

journal_name

Ann Biomed Eng

authors

Chnafa C,Mendez S,Nicoud F

doi

10.1007/s10439-016-1614-6

subject

Has Abstract

pub_date

2016-11-01 00:00:00

pages

3346-3358

issue

11

eissn

0090-6964

issn

1573-9686

pii

10.1007/s10439-016-1614-6

journal_volume

44

pub_type

杂志文章
  • Superparamagnetic iron oxide is suitable to label tendon stem cells and track them in vivo with MR imaging.

    abstract::Tendon stem cells (TSCs) may be used to effectively repair or regenerate injured tendons. However, the fates of TSCs once implanted in vivo remain unclear. This study was aimed to determine the feasibility of labeling TSCs with super-paramagnetic iron oxide (SPIO) nano-particles to track TSCs in vivo using MRI. Rabbit...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-013-0802-x

    authors: Yang Y,Zhang J,Qian Y,Dong S,Huang H,Boada FE,Fu FH,Wang JH

    更新日期:2013-10-01 00:00:00

  • Mechanics of a thin walled collapsible microtube.

    abstract::The purpose of this study is to measure the transmural pressure-cross sectional area relation of micro tubes (240 microns diameter) and to compare the measured perfusion pressure-flow relation with the pressure-flow relation calculated from the experimental pressure-cross sectional area relation. The microtubes are ma...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02368042

    authors: Sipkema P,Westerhof N

    更新日期:1989-01-01 00:00:00

  • Net change in periosteal strain during stance shift loading after surgery correlates to rapid de novo bone generation in critically sized defects.

    abstract::In an ovine femur model, proliferative woven bone fills critically sized defects enveloped by periosteum within 2 weeks of treatment with the one-stage bone-transport surgery. We hypothesize that mechanical loading modulates this process. Using high-definition optical strain measurements we determined prevailing perio...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-0242-9

    authors: McBride SH,Dolejs S,Brianza S,Knothe U,Knothe Tate ML

    更新日期:2011-05-01 00:00:00

  • Detergent-Based Decellularization of Bovine Carotid Arteries for Vascular Tissue Engineering.

    abstract::Vascular diseases are an increasing health issue, and common alloplastic, allogenic or autologous vascular grafts show frequent complications. The aim of this study is to develop an acellular, xenogenic bypass-graft from a bovine carotid artery (BAC) using detergent-based protocols. We compared decellularization with ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-017-1892-7

    authors: Daugs A,Hutzler B,Meinke M,Schmitz C,Lehmann N,Markhoff A,Bloch O

    更新日期:2017-11-01 00:00:00

  • HFUS Imaging of the Cochlea: A Feasibility Study for Anatomical Identification by Registration with MicroCT.

    abstract::Cochlear implantation consists in electrically stimulating the auditory nerve by inserting an electrode array inside the cochlea, a bony structure of the inner ear. In the absence of any visual feedback, the insertion results in many cases of damages of the internal structures. This paper presents a feasibility study ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02671-1

    authors: Lavenir L,Zemiti N,Akkari M,Subsol G,Venail F,Poignet P

    更新日期:2020-10-30 00:00:00

  • Bioreactors for development of tissue engineered heart valves.

    abstract::Millions of people worldwide are diagnosed each year with valvular heart disease, resulting in hundreds of thousands of valve replacement operations. Prosthetic valve replacements are designed to correct narrowing or backflow through the valvular orifice. Although commonly used, these therapies have serious disadvanta...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/s10439-010-0148-6

    authors: Berry JL,Steen JA,Koudy Williams J,Jordan JE,Atala A,Yoo JJ

    更新日期:2010-11-01 00:00:00

  • The effect of visual and sensory performance on head impact biomechanics in college football players.

    abstract::The development of prevention strategies is critical to address the rising prevalence of sport-related concussions. Visual and sensory performance may influence an individual's ability to interpret environmental cues, anticipate opponents' actions, and create appropriate motor responses limiting the severity of an imp...

    journal_title:Annals of biomedical engineering

    pub_type: 临床试验,杂志文章

    doi:10.1007/s10439-013-0881-8

    authors: Harpham JA,Mihalik JP,Littleton AC,Frank BS,Guskiewicz KM

    更新日期:2014-01-01 00:00:00

  • Fluid dynamics of gas exchange in high-frequency oscillatory ventilation: in vitro investigations in idealized and anatomically realistic airway bifurcation models.

    abstract::The objective of this work is to develop understanding of the local fluid dynamic mechanisms that underpin gas exchange in high-frequency oscillatory ventilation (HFOV). The flow field during HFOV was investigated experimentally using particle image velocimetry in idealized and realistic models of a single bifurcation...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-008-9557-1

    authors: Heraty KB,Laffey JG,Quinlan NJ

    更新日期:2008-11-01 00:00:00

  • Pulsatile flow in tubes of elliptic cross sections.

    abstract::The compression of blood vessels by surrounding tissue is an important problem in hemodynamics, most prominently in studies relating to the heart. In this study we consider a long tube of elliptic cross section as an idealization of the geometry of a compressed blood vessel. An exact solution of the governing equation...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.106

    authors: Haslam M,Zamir M

    更新日期:1998-09-01 00:00:00

  • Creating living cellular machines.

    abstract::Development of increasingly complex integrated cellular systems will be a major challenge for the next decade and beyond, as we apply the knowledge gained from the sub-disciplines of regenerative medicine, synthetic biology, micro-fabrication and nanotechnology, systems biology, and developmental biology. In this pros...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/s10439-013-0902-7

    authors: Kamm RD,Bashir R

    更新日期:2014-02-01 00:00:00

  • The effect of head rotation on the geometry and hemodynamics of healthy vertebral arteries.

    abstract::The geometric and hemodynamic characteristics of the left and right vertebral arteries (LVA, RVA) of six healthy volunteers were investigated for the supine (S) and the prone position (P) a common sleeping posture with head rotation. MRI images were used to reconstruct the subject specific three-dimensional solid mode...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1340-5

    authors: Aristokleous N,Seimenis I,Georgiou GC,Nicolaides A,Anayiotos AS

    更新日期:2015-06-01 00:00:00

  • Simultaneous Measurement of Contraction and Calcium Transients in Stem Cell Derived Cardiomyocytes.

    abstract::Induced pluripotent stem cell derived cardiomyocytes (iPSC-CM) provide a powerful platform for disease modeling and drug development in vitro. Traditionally, electrophysiological methods or fluorescent dyes (e.g. calcium) have been used in their functional characterization. Recently, video microscopy has enabled non-i...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-017-1933-2

    authors: Ahola A,Pölönen RP,Aalto-Setälä K,Hyttinen J

    更新日期:2018-01-01 00:00:00

  • The placement of skin surface markers for non-invasive measurement of scapular kinematics affects accuracy and reliability.

    abstract::Abnormal scapular movement is widely believed to be an important factor in clinical pathology of the shoulder joint complex. Validated non-invasive techniques for measuring scapular movement have been developed, but the effect of marker placement on accuracy is unknown. The objective of this study was to determine the...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-0185-1

    authors: Bourne DA,Choo AM,Regan WD,MacIntyre DL,Oxland TR

    更新日期:2011-02-01 00:00:00

  • Novel organotypic cultures of human skin explants with an implant-tissue biomaterial interface.

    abstract::A novel in vitro culture system of organotypic human skin explants interfacing with external fixator pins is presented. The system was used to observe changes in skin morphology on the skin at the pin interface. To evaluate the performance of this novel system, histological analysis of human skin explants cultured for...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-008-9614-9

    authors: Peramo A,Marcelo CL,Goldstein SA,Martin DC

    更新日期:2009-02-01 00:00:00

  • Velocity measurements within confined turbulent jets: application to cardiovalvular regurgitation.

    abstract::An expression for centerline mean velocity distributions for circular and noncircular confined turbulent jets has been obtained by assuming self-preservation of flow downstream of the jet potential core. It was assumed that the velocity decay was not only dependent on the streamwise distance x in terms of x/d, as in t...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:

    authors: Liu H,Winoto SH,Shah DA

    更新日期:1997-11-01 00:00:00

  • Low strength static magnetic field inhibits the proliferation, migration, and adhesion of human vascular smooth muscle cells in a restenosis model through mediating integrins β1-FAK, Ca2+ signaling pathway.

    abstract::The proliferation, migration, and adhesion of vascular smooth muscle cells (VSMCs) and their interactions with extracellular matrix are key features of atherosclerosis and restenosis. Recently, there has been evidence that magnetic fields exert multiple effects on the biological performance of cells and may aid in the...

    journal_title:Annals of biomedical engineering

    pub_type: 临床试验,杂志文章

    doi:10.1007/s10439-012-0602-8

    authors: Li Y,Song LQ,Chen MQ,Zhang YM,Li J,Feng XY,Li W,Guo W,Jia G,Wang H,Yu J

    更新日期:2012-12-01 00:00:00

  • Utilizing Atlas-Based Modeling to Predict Knee Joint Cartilage Degeneration: Data from the Osteoarthritis Initiative.

    abstract::Currently, there are no clinically available tools or applications which could predict osteoarthritis development. Some computational models have been presented to simulate cartilage degeneration, but they are not clinically feasible due to time required to build subject-specific knee models. Therefore, the objective ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-018-02184-y

    authors: Mononen ME,Liukkonen MK,Korhonen RK

    更新日期:2019-03-01 00:00:00

  • Polycrystalline silicon micromachining: a new technology for integrated sensors.

    abstract::Polycrystalline silicon (poly-Si) micromechanical structures can be made by selectively etching an underlying sacrificial oxide layer. Advantages of this micromachining technique are its simplicity and compatibility with conventional integrated-circuit processing. Compressive internal stress in poly-Si films constrain...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02584269

    authors: Howe RT

    更新日期:1986-01-01 00:00:00

  • Progression of abdominal aortic aneurysm towards rupture: refining clinical risk assessment using a fully coupled fluid-structure interaction method.

    abstract::Rupture of abdominal aortic aneurysm (AAA) is associated with high mortality rates. Risk of rupture is multi-factorial involving AAA geometric configuration, vessel tortuosity, and the presence of intraluminal pathology. Fluid structure interaction (FSI) simulations were conducted in patient based computed tomography ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-014-1224-0

    authors: Xenos M,Labropoulos N,Rambhia S,Alemu Y,Einav S,Tassiopoulos A,Sakalihasan N,Bluestein D

    更新日期:2015-01-01 00:00:00

  • Skull flexure as a contributing factor in the mechanism of injury in the rat when exposed to a shock wave.

    abstract::The manner in which energy from an explosion is transmitted into the brain is currently a highly debated topic within the blast injury community. This study was conducted to investigate the injury biomechanics causing blast-related neurotrauma in the rat. Biomechanical responses of the rat head under shock wave loadin...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-011-0343-0

    authors: Bolander R,Mathie B,Bir C,Ritzel D,VandeVord P

    更新日期:2011-10-01 00:00:00

  • Pixel-Based DXA-Derived Structural Properties Strongly Correlate with pQCT Measures at the One-Third Distal Femur Site.

    abstract::While bone mineral density has been traditionally used to quantify fracture risk for individuals with spinal cord injuries, recent studies are including engineering measurements such as section modulus and cross sectional moment of inertia. These are almost exclusively calculated by peripheral QCT scanners which, unli...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-017-1796-6

    authors: Baker AM,Wagner DW,Kiratli BJ,Beaupre GS

    更新日期:2017-05-01 00:00:00

  • Low-Profile Electromagnetic Field Sensors in the Measurement and Modelling of Three-Dimensional Jaw Kinematics and Occlusal Loading.

    abstract::Dynamic occlusal loading during mastication is clinically relevant in the design and functional assessment of dental restorations and removable dentures, and in evaluating temporomandibular joint dysfunction. The aim of this study was to develop a modelling framework to evaluate subject-specific dynamic occlusal loadi...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02688-6

    authors: Woodford SC,Robinson DL,Edelmann C,Mehl A,Röhrle O,Vee Sin Lee P,Ackland DC

    更新日期:2021-01-06 00:00:00

  • A regional blood flow model for β2-microglobulin kinetics and for simulating intra-dialytic exercise effect.

    abstract::A kinetic model based on first principles, for β(2)-microglobulin, is presented to obtain precise parameter estimates for individual patient. To reduce the model complexity, the number of model parameters was reduced using a priori identifiability analysis. The model validity was confirmed with the clinical data of te...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-011-0383-5

    authors: Maheshwari V,Samavedham L,Rangaiah GP

    更新日期:2011-12-01 00:00:00

  • Parametric Design Optimisation of Proximal Humerus Plates Based on Finite Element Method.

    abstract::Optimal treatment of proximal humerus fractures remains controversial. Locking plates offer theoretical advantages but are associated with complications in the clinic. This study aimed to perform parametric design optimisation of proximal humerus plates to enhance their mechanical performance. A finite element (FE) mo...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-018-02160-6

    authors: Jabran A,Peach C,Zou Z,Ren L

    更新日期:2019-02-01 00:00:00

  • The Microcirculation Physiome Project.

    abstract::Presented is a discussion of steps towards the creation of a database of the microcirculation encompassing anatomical and functional experimental data, and conceptual and computational models. The discussion includes issues of database utility, organization, data deposition, and linkage to other databases. The databas...

    journal_title:Annals of biomedical engineering

    pub_type:

    doi:10.1114/1.112

    authors: Popel AS,Greene AS,Ellis CG,Ley KF,Skalak TC,Tonellato PJ

    更新日期:1998-11-01 00:00:00

  • Personalized Perioperative Multi-scale, Multi-physics Heart Simulation of Double Outlet Right Ventricle.

    abstract::For treatment of complex congenital heart disease, computer simulation using a three-dimensional heart model may help to improve outcomes by enabling detailed preoperative evaluations. However, no highly integrated model that accurately reproduces a patient's pathophysiology, which is required for this simulation has ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02488-y

    authors: Kariya T,Washio T,Okada JI,Nakagawa M,Watanabe M,Kadooka Y,Sano S,Nagai R,Sugiura S,Hisada T

    更新日期:2020-06-01 00:00:00

  • Continuous blood density measurement for hemodynamic monitoring: an analysis of its accuracy and sensitivity.

    abstract::Continuous measurement of arterial blood density after bolus injection of fluids of different density into the right atrium has been used to measure cardiac output and mean transit time through the central circulation. The transit time distribution for density, however, differs from that for plasma-phase tracers such ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02368628

    authors: Ligas JR,Moslehi F,Epstein MA

    更新日期:1993-07-01 00:00:00

  • Effect of mechanical strain on solute diffusion in human TMJ discs: an electrical conductivity study.

    abstract::This study investigated the effect of mechanical strain on solute diffusion in human TMJ discs (mean cadaver age 77.8) using the electrical conductivity method. The electrical conductivity, as well as small ion diffusivity, of male and female TMJ discs was determined under three compressive strains. In the male group,...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-013-0840-4

    authors: Wright GJ,Kuo J,Shi C,Bacro TR,Slate EH,Yao H

    更新日期:2013-11-01 00:00:00

  • A microcomputer oxygen control system for ventilatory therapy.

    abstract::A computer-based feedback system has been developed to adjust the concentration of oxygen in the inspired gas of a patient under artificial respiration. The system uses a proportional plus integral controller and feedback of arterial oxygen saturation to adjust the inspired oxygen fraction. The effectiveness of the co...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02368173

    authors: Tehrani FT

    更新日期:1992-01-01 00:00:00

  • Human saphenous vein coronary artery bypass graft morphology, geometry and hemodynamics.

    abstract::Coronary artery bypass graft (CABG) failure has been linked to graft hemodynamics, in particular wall shear stress. This study characterizes the morphology, geometry and wall shear stress patterns in human CABGs. The intimal thickness (IT) in 49 human saphenous vein CABGs was measured by digital light microscopy. The ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-005-1732-z

    authors: Leask RL,Butany J,Johnston KW,Ethier CR,Ojha M

    更新日期:2005-03-01 00:00:00