Novel organotypic cultures of human skin explants with an implant-tissue biomaterial interface.

Abstract:

:A novel in vitro culture system of organotypic human skin explants interfacing with external fixator pins is presented. The system was used to observe changes in skin morphology on the skin at the pin interface. To evaluate the performance of this novel system, histological analysis of human skin explants cultured for 5 days at the air-liquid interface was performed. Compared to control explants, specimens interfaced with pins (treated or not with a physiological saline solution) showed a deteriorating basal layer, a disappearing stratum spinosum and increased lost of elastic fibers in the dermis. The model system makes it possible to perform rapid, repeatable studies of living skin response to chronically implanted materials and devices.

journal_name

Ann Biomed Eng

authors

Peramo A,Marcelo CL,Goldstein SA,Martin DC

doi

10.1007/s10439-008-9614-9

subject

Has Abstract

pub_date

2009-02-01 00:00:00

pages

401-9

issue

2

eissn

0090-6964

issn

1573-9686

journal_volume

37

pub_type

杂志文章
  • Functional augmentation of naturally-derived materials for tissue regeneration.

    abstract::Tissue engineering strategies have utilized a wide spectrum of synthetic and naturally-derived scaffold materials. Synthetic scaffolds are better defined and offer the ability to precisely and reproducibly control their properties, while naturally-derived scaffolds typically have inherent biological and structural pro...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/s10439-014-1192-4

    authors: Allen AB,Priddy LB,Li MT,Guldberg RE

    更新日期:2015-03-01 00:00:00

  • Parameter estimation for linear compartmental models--a sensitivity analysis approach.

    abstract::Linear compartmental models are useful, explanatory tools, that have been widely used to represent the dynamic behavior of complex biological systems. This paper addresses the problem of the numerical identification of such models, i.e., the estimation of the parameter values that will generate predictions closest to ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-009-9651-z

    authors: Juillet B,Bos C,Gaudichon C,Tomé D,Fouillet H

    更新日期:2009-05-01 00:00:00

  • 3D Printed Vascular Networks Enhance Viability in High-Volume Perfusion Bioreactor.

    abstract::There is a significant clinical need for engineered bone graft substitutes that can quickly, effectively, and safely repair large segmental bone defects. One emerging field of interest involves the growth of engineered bone tissue in vitro within bioreactors, the most promising of which are perfusion bioreactors. Usin...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-016-1662-y

    authors: Ball O,Nguyen BB,Placone JK,Fisher JP

    更新日期:2016-12-01 00:00:00

  • Identification of static and dynamic components of reflex sensitivity in spastic elbow flexors using a muscle activation model.

    abstract::Static and dynamic components of the stretch reflex were studied in elbow flexors of 13 hemiparetic brain-injured individuals. Constant-velocity joint rotations were applied to the elbow, and the resulting stretch reflex torque and electromyographic responses were recorded in the biceps brachii and brachioradialis mus...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1359496

    authors: Schmit BD,Rymer WZ

    更新日期:2001-04-01 00:00:00

  • Fatigue of Metallic Stents: From Clinical Evidence to Computational Analysis.

    abstract::The great success of stents in treating cardiovascular disease is actually undermined by their long-term fatigue failure. The high variability of stent failure incidence suggests that it is due to several correlated aspects, such as loading conditions, material properties, component design, surgical procedure, and pat...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1447-8

    authors: Auricchio F,Constantinescu A,Conti M,Scalet G

    更新日期:2016-02-01 00:00:00

  • Measurement of signal and noise characteristics in ongoing auditory brainstem response averaging.

    abstract::Although diagnostic testing with auditory evoked potentials (EPs) has become routine, quantitative measurements of signal and noise are still lacking. In this study, current signal, power, noise power, and signal-to-noise ratio (SNR) estimation formulas are reviewed and applied to auditory brainstem response averaging...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02684183

    authors: Ozdamar O,Delgado RE

    更新日期:1996-11-01 00:00:00

  • Signaling in the motility responses of the human neutrophil.

    abstract::The neutrophil has developed into one of the most efficient vertebrate motile cells. It migrates through tissues, where it encounters multiple chemoattractant signals with complex spatial and temporal characteristics. The directional movement of the neutrophil is signaled by the binding of chemoattractants and chemoki...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1114/1.1477446

    authors: Zhelev DV,Alteraifi A

    更新日期:2002-03-01 00:00:00

  • Mesh Convergence Behavior and the Effect of Element Integration of a Human Head Injury Model.

    abstract::Numerous head injury models exist that vary in mesh density by orders of magnitude. A careful study of the mesh convergence behavior is necessary, especially in terms of strain most relevant to brain injury. To this end, as well as to investigate the effect of element integration scheme on simulated strains, we re-mes...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-018-02159-z

    authors: Zhao W,Ji S

    更新日期:2019-02-01 00:00:00

  • Continuous blood density measurement for hemodynamic monitoring: an analysis of its accuracy and sensitivity.

    abstract::Continuous measurement of arterial blood density after bolus injection of fluids of different density into the right atrium has been used to measure cardiac output and mean transit time through the central circulation. The transit time distribution for density, however, differs from that for plasma-phase tracers such ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02368628

    authors: Ligas JR,Moslehi F,Epstein MA

    更新日期:1993-07-01 00:00:00

  • Comparison of respiratory rates derived from heart rate variability, ECG amplitude, and nasal/oral airflow.

    abstract::It would often be desirable to obtain the respiratory rate during everyday conditions without obtaining an additional respiratory trace. This study investigates the agreement between respiratory rate assessed from the electrocardiogram (ECG) and the reference respiratory rate derived from a nasal/oral airflow (AF). Na...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-008-9580-2

    authors: Cysarz D,Zerm R,Bettermann H,Frühwirth M,Moser M,Kröz M

    更新日期:2008-12-01 00:00:00

  • Extracellular potentials and currents of a single active fiber in a restricted volume conductor.

    abstract::Based on mathematical expressions governing the electric field, the extracellular potentials generated by a single active fiber in a restricted circular cylindrical volume conductor are evaluated. This paper examines the effect of the extent of the volume conductor, with radius b, on the extracellular potentials at di...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02368439

    authors: Trayanova N,Henriquez CS,Plonsey R

    更新日期:1990-01-01 00:00:00

  • High-resolution measurement of the unsteady velocity field to evaluate blood damage induced by a mechanical heart valve.

    abstract::We investigate the potential of prosthetic heart valves to generate abnormal flow and stress patterns, which can contribute to platelet activation and lysis according to blood damage accumulation mechanisms. High-resolution velocity measurements of the unsteady flow field, obtained with a standard particle image veloc...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-011-0329-y

    authors: Bellofiore A,Quinlan NJ

    更新日期:2011-09-01 00:00:00

  • Multi-Dimensional Nanostructures for Microfluidic Screening of Biomarkers: From Molecular Separation to Cancer Cell Detection.

    abstract::Rapid screening of biomarkers, with high specificity and accuracy, is critical for many point-of-care diagnostics. Microfluidics, the use of microscale channels to manipulate small liquid samples and carry reactions in parallel, offers tremendous opportunities to address fundamental questions in biology and provide a ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/s10439-015-1521-2

    authors: Ng E,Chen K,Hang A,Syed A,Zhang JX

    更新日期:2016-04-01 00:00:00

  • Modeling the instantaneous pressure-volume relation of the left ventricle: a comparison of six models.

    abstract::Simulations are useful to study the heart's ability to generate flow and the interaction between contractility and loading conditions. The left ventricular pressure-volume (PV) relation has been shown to be nonlinear, but it is unknown whether a linear model is accurate enough for simulations. Six models were fitted t...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-009-9742-x

    authors: Lankhaar JW,Rövekamp FA,Steendijk P,Faes TJ,Westerhof BE,Kind T,Vonk-Noordegraaf A,Westerhof N

    更新日期:2009-09-01 00:00:00

  • Large-scale 3-D geometric reconstruction of the porcine coronary arterial vasculature based on detailed anatomical data.

    abstract::The temporal and spatial distribution of coronary blood flow, pressure, and volume are determined by the branching pattern and three-dimensional (3-D) geometry of the coronary vasculature, and by the mechanics of heart wall and vascular tone. Consequently, a realistic simulation of coronary blood flow requires, as a f...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-005-7544-3

    authors: Kaimovitz B,Lanir Y,Kassab GS

    更新日期:2005-11-01 00:00:00

  • The impedance of a spherical monopolar electrode.

    abstract::The impedance of a monopolar electrode immersed in an environmental volume conductor consists of two parts; the impedance of the active electrode-electrolyte interface, and the resistance of the environmental conductor. Two studies were carried out to quantitate these components. First, impedance-frequency data were c...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02368609

    authors: Ragheb T,Riegle S,Geddes LA,Amin V

    更新日期:1992-01-01 00:00:00

  • Investigation of the Sequential Actions of Doxorubicin and p53 on Tumor Cell Growth Via Branched Polyethylenimine-β-cyclodextrin Conjugates.

    abstract::The combination of gene therapy and chemotherapy has showed increased therapeutic efficacy in the treatment of cancers, but it is not well investigated about the actual coordination pattern between therapeutic gene and chemical drug. In this work, p53/BPEI-β-CD/AD-dox complex was fabricated and employed to investigate...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-016-1627-1

    authors: Xie B,Peng J,Wang S,Zhang X,Nie H

    更新日期:2016-11-01 00:00:00

  • Numerical validation of MR-measurement-integrated simulation of blood flow in a cerebral aneurysm.

    abstract::This study proposes magnetic resonance (MR)-measurement-integrated (MR-MI) simulation, in which the difference between the computed velocity field and the phase-contrast MRI measurement data is fed back to the numerical simulation. The computational accuracy and the fundamental characteristics, such as steady characte...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-009-9689-y

    authors: Funamoto K,Suzuki Y,Hayase T,Kosugi T,Isoda H

    更新日期:2009-06-01 00:00:00

  • Bioengineering the skin-implant interface: the use of regenerative therapies in implanted devices.

    abstract::This discussion and review article focuses on the possible use of regenerative techniques applied to the interfaces between skin and medical implants. As is widely known, the area of contact between an implant and the skin--the skin-implant interface--is prone to recurrent and persistent problems originated from the l...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/s10439-010-9937-1

    authors: Peramo A,Marcelo CL

    更新日期:2010-06-01 00:00:00

  • Net change in periosteal strain during stance shift loading after surgery correlates to rapid de novo bone generation in critically sized defects.

    abstract::In an ovine femur model, proliferative woven bone fills critically sized defects enveloped by periosteum within 2 weeks of treatment with the one-stage bone-transport surgery. We hypothesize that mechanical loading modulates this process. Using high-definition optical strain measurements we determined prevailing perio...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-0242-9

    authors: McBride SH,Dolejs S,Brianza S,Knothe U,Knothe Tate ML

    更新日期:2011-05-01 00:00:00

  • Degradation, bioactivity, and osteogenic potential of composites made of PLGA and two different sol-gel bioactive glasses.

    abstract::We have developed poly(L: -lactide-co-glycolide) (PLGA) based composites using sol-gel derived bioactive glasses (S-BG), previously described by our group, as composite components. Two different composite types were manufactured that contained either S2-high content silica S-BG, or A2-high content lime S-BG. The compo...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-011-0307-4

    authors: Pamula E,Kokoszka J,Cholewa-Kowalska K,Laczka M,Kantor L,Niedzwiedzki L,Reilly GC,Filipowska J,Madej W,Kolodziejczyk M,Tylko G,Osyczka AM

    更新日期:2011-08-01 00:00:00

  • Enhancement of stent-induced thromboembolism by residual stenoses: contribution of hemodynamics.

    abstract::In vitro stent-induced thromboembolism was altered by the presence of residual stenoses placed upstream or placed upstream and downstream of the stent. Heparinized (3 micro/ml) bovine blood was gravity fed through a conduit with a deployed coronary stent. Embolism was continuously monitored using a light-scattering mi...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.243

    authors: Sukavaneshvar S,Rosa GM,Solen KA

    更新日期:2000-02-01 00:00:00

  • An evaluation of population D-optimal designs via pharmacokinetic simulations.

    abstract::One goal of large scale clinical trials is to determine how a drug is processed by, and cleared from, the human body [i.e., its pharmacokinetic (PK) properties] and how these PK properties differ between individuals in a population (i.e., its population PK properties). Due to the high cost of these studies and the lim...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1533074

    authors: Hooker AC,Foracchia M,Dodds MG,Vicini P

    更新日期:2003-01-01 00:00:00

  • A Wearable Magnet-Based System to Assess Activity and Joint Flexion in Humans and Large Animals.

    abstract::Functional outcomes, such as joint flexion and gait, are important indicators of efficacy in musculoskeletal research. Current technologies that objectively assess these parameters, including visual tracking systems and force plates, are challenging to deploy in long-term translational and clinical studies. To that en...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-018-2105-8

    authors: Qu F,Stoeckl BD,Gebhard PM,Hullfish TJ,Baxter JR,Mauck RL

    更新日期:2018-12-01 00:00:00

  • Neurite outgrowth on a DNA crosslinked hydrogel with tunable stiffnesses.

    abstract::Mechanical cues arising from extracellular matrices greatly affect cellular properties, and hence, are of significance in designing biomaterials. In this study, a DNA crosslinked hydrogel was employed to examine cellular responses of spinal cord neurons to substrate compliances. Using DNA as crosslinkers in polymeric ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-008-9530-z

    authors: Jiang FX,Yurke B,Firestein BL,Langrana NA

    更新日期:2008-09-01 00:00:00

  • Time-frequency approaches for the detection of interactions and temporal properties in renal autoregulation.

    abstract::We compare the influence of time-frequency methods on analysis of time-varying renal autoregulation properties. Particularly, we examine if detection probabilities are similar for amplitude and frequency modulation for a modulated simulation signal among five time-frequency approaches, and if time-varying changes in s...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-012-0625-1

    authors: Scully CG,Siu KL,Cupples WA,Braam B,Chon KH

    更新日期:2013-01-01 00:00:00

  • Functionalized biomicroelectromechanical systems sensors for force response study at local adhesion sites of single living cells on substrates.

    abstract::We present a method of measuring force response of a single living cell, attached to a substrate, in situ, by a functionalized microelectromechanical systems sensor that applies local deformation on the cell. The sensor is a single crystal silicon microcantilever beam with prescribed shape and geometry, and is coated ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1591189

    authors: Saif MT,Sager CR,Coyer S

    更新日期:2003-09-01 00:00:00

  • Evaluation of human endothelial cells post stent deployment in a cardiovascular simulator in vitro.

    abstract::Percutaneous stent implantation has revolutionized the clinical treatment of occluded arteries. Nevertheless, there is still a large unmet need to prevent re-occlusion after implantation. Consequently, a niche exists for a cost-effective pre-clinical method of evaluating novel interventional devices in human models. T...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-009-9701-6

    authors: Punchard MA,O'Cearbhaill ED,Mackle JN,McHugh PE,Smith TJ,Stenson-Cox C,Barron V

    更新日期:2009-07-01 00:00:00

  • Tissue remodeling of rat pulmonary artery in hypoxic breathing. II. Course of change of mechanical properties.

    abstract::When cells and the matrix of a tissue remodel, the mechanical properties of the tissue do change. The mechanical properties are expressed by constitutive equations. In this article the remodeling of the constitutive equation of the pulmonary artery is studied. The remodeling was induced in a rat breathing a gas whose ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1380417

    authors: Huang W,Delgado-West D,Wu JT,Fung YC

    更新日期:2001-01-01 00:00:00

  • Predicting the responses of mechanoreceptor neurons to physiological inputs by nonlinear system identification.

    abstract::The nonlinear dynamic properties of action potential encoding were studied in mechanosensory neurons innervating the slits of a slit-sense organ in the tropical wandering spider, Cupiennius salei. The organ contains two types of neurons that are morphologically similar but have different dynamic properties. Type A neu...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1355278

    authors: French AS,Sekizawa SI,Höger U,Torkkeli PH

    更新日期:2001-03-01 00:00:00