Low strength static magnetic field inhibits the proliferation, migration, and adhesion of human vascular smooth muscle cells in a restenosis model through mediating integrins β1-FAK, Ca2+ signaling pathway.

Abstract:

:The proliferation, migration, and adhesion of vascular smooth muscle cells (VSMCs) and their interactions with extracellular matrix are key features of atherosclerosis and restenosis. Recently, there has been evidence that magnetic fields exert multiple effects on the biological performance of cells and may aid in the treatment of vascular disease. However, the effect of a static magnetic field (SMF) on human VSMCs still remains unknown. In this study, we aimed to determine the effects of low strength SMF on human VSMCs in an in vitro restenosis model. A SMF was established using neodymium-yttrium-iron permanent magnet. Human umbilical artery smooth muscle cells (hUASMCs) were isolated and seeded to a fibronectin-coated plate to form an in vitro restenosis model and then exposed to a vertically oriented field of 5 militesla (mT). MTT, transwell, and adhesion assays were used to demonstrate that the proliferation, migration, and adhesion potential of hUASMCs were significantly decreased after exposure to 5 mT SMF for 48 h compared with a non-treated group. Meanwhile, confocal microscopy analysis was used to demonstrate that integrin β(1) clustering was inhibited by exposure to 5 mT SMF. Furthermore, the phosphorylation of focal adhesion kinase (FAK) was markedly inhibited, and the upregulated cytosolic free calcium had been reversed (p < 0.05). However, the biological effects of low strength SMF on hUASMCs could be blocked by the administration of GRGDSP-the blockade of integrins. In conclusion, a low strength SMF can influence the proliferation, migration, and adhesion of VSMCs by inhibiting the clustering of integrin β1, decreasing cytosolic free calcium concentration, and inactivating FAK. With further validation, SMFs may aid in attenuating abnormal VSMCs biological performance and has potential to block atherogenesis and prevent restenosis.

journal_name

Ann Biomed Eng

authors

Li Y,Song LQ,Chen MQ,Zhang YM,Li J,Feng XY,Li W,Guo W,Jia G,Wang H,Yu J

doi

10.1007/s10439-012-0602-8

subject

Has Abstract

pub_date

2012-12-01 00:00:00

pages

2611-8

issue

12

eissn

0090-6964

issn

1573-9686

journal_volume

40

pub_type

临床试验,杂志文章
  • Impedances of thin and layered systems: cells with even or odd numbers of interfaces.

    abstract::Impedance data, e.g., system responses, from perturbing small amplitude applied sinusoid signals of near DC to high kilohertz frequencies, give chemical information. Analysis of frequency-dependent imaginary and real impedance proceeds from equivalent analog circuit elements to chemical and physical significance deter...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02368537

    authors: Buck RP

    更新日期:1992-01-01 00:00:00

  • Models of flow-induced loading on blood cells in laminar and turbulent flow, with application to cardiovascular device flow.

    abstract::Viscous shear stress and Reynolds stress are often used to predict hemolysis and thrombosis due to flow-induced stress on blood elements in cardiovascular devices. These macroscopic stresses are distinct from the true stress on an individual cell, which is determined by the local microscale flow field. In this paper t...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-007-9308-8

    authors: Quinlan NJ,Dooley PN

    更新日期:2007-08-01 00:00:00

  • Blood pressure measurement in noise intensive environments using adaptive interference cancellation.

    abstract::The traditional auscultatory technique and current methodologies for measuring human blood pressure are limited when used in situations where extreme vibration or acoustic noise is present. In this study, human subjects were used to establish the effectiveness of a novel adaptive blood pressure monitoring (ABPM) syste...

    journal_title:Annals of biomedical engineering

    pub_type: 临床试验,杂志文章

    doi:10.1114/1.1481051

    authors: Pinto L,Dhanantwari A,Wong W,Stergiopoulos S,Maris M

    更新日期:2002-05-01 00:00:00

  • The effect of visual and sensory performance on head impact biomechanics in college football players.

    abstract::The development of prevention strategies is critical to address the rising prevalence of sport-related concussions. Visual and sensory performance may influence an individual's ability to interpret environmental cues, anticipate opponents' actions, and create appropriate motor responses limiting the severity of an imp...

    journal_title:Annals of biomedical engineering

    pub_type: 临床试验,杂志文章

    doi:10.1007/s10439-013-0881-8

    authors: Harpham JA,Mihalik JP,Littleton AC,Frank BS,Guskiewicz KM

    更新日期:2014-01-01 00:00:00

  • Particle motion within in vitro models of stenosed internal carotid and left anterior descending coronary arteries.

    abstract::Asymmetric 75% and 95% area reduction, transparent Sylgard stenotic models were operated under internal carotid artery (ICA) [Womersley parameter, alpha=5.36, Re(mean) =213 and 180, respectively, and Re(peak)=734 and 410, respectively] and left anterior descending coronary artery (LAD) flow wave forms (alpha=2.65, Re(...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.131

    authors: Cao J,Rittgers SE

    更新日期:1998-03-01 00:00:00

  • Phospholipids identified on the pericardium and their ability to impart boundary lubrication.

    abstract::Phospholipids have been identified by thin-layer chromatography in appreciable quantities in pericardial fluid taken from 12 dogs and found to include sphingomyelin and phosphatidylcholines, -ethanolamines, -inositols and -serines--the cholines predominating. The extracts, the synthetic surfactants and a mixture of sy...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02584258

    authors: Hills BA,Butler BD

    更新日期:1985-01-01 00:00:00

  • Fatigue of Metallic Stents: From Clinical Evidence to Computational Analysis.

    abstract::The great success of stents in treating cardiovascular disease is actually undermined by their long-term fatigue failure. The high variability of stent failure incidence suggests that it is due to several correlated aspects, such as loading conditions, material properties, component design, surgical procedure, and pat...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1447-8

    authors: Auricchio F,Constantinescu A,Conti M,Scalet G

    更新日期:2016-02-01 00:00:00

  • Static magnetic fields promote osteoblast-like cells differentiation via increasing the membrane rigidity.

    abstract::The aim of this study was to test the differentiative effects of osteoblasts after treatment with a static magnetic field (SMF). MG63 osteoblast-like cells were exposed to a 0.4-T SMF. The differentiation markers were assessed by observing the changes in alkaline phosphatase activity and electron microscopy images. Me...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-007-9370-2

    authors: Chiu KH,Ou KL,Lee SY,Lin CT,Chang WJ,Chen CC,Huang HM

    更新日期:2007-11-01 00:00:00

  • Computational approach to estimating the effects of blood properties on changes in intra-stent flow.

    abstract::In this study various blood rheological assumptions are numerically investigated for the hemodynamic properties of intra-stent flow. Non-newtonian blood properties have never been implemented in blood coronary stented flow investigation, although its effects appear essential for a correct estimation and distribution o...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-006-9123-7

    authors: Benard N,Perrault R,Coisne D

    更新日期:2006-08-01 00:00:00

  • Investigating the influence of haemodynamic stimuli on intracranial aneurysm inception.

    abstract::We propose a novel method to reconstruct the hypothetical geometry of the healthy vasculature prior to intracranial aneurysm (IA) formation: a Frenet frame is calculated along the skeletonization of the arterial geometry; upstream and downstream boundaries of the aneurysmal segment are expressed in terms of the local ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-013-0794-6

    authors: Chen H,Selimovic A,Thompson H,Chiarini A,Penrose J,Ventikos Y,Watton PN

    更新日期:2013-07-01 00:00:00

  • Error mechanisms of the oscillometric fixed-ratio blood pressure measurement method.

    abstract::The oscillometric fixed-ratio method is widely employed for non-invasive measurement of systolic and diastolic pressures (SP and DP) but is heuristic and prone to error. We investigated the accuracy of this method using an established mathematical model of oscillometry. First, to determine which factors materially aff...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-012-0700-7

    authors: Liu J,Hahn JO,Mukkamala R

    更新日期:2013-03-01 00:00:00

  • Polycrystalline silicon micromachining: a new technology for integrated sensors.

    abstract::Polycrystalline silicon (poly-Si) micromechanical structures can be made by selectively etching an underlying sacrificial oxide layer. Advantages of this micromachining technique are its simplicity and compatibility with conventional integrated-circuit processing. Compressive internal stress in poly-Si films constrain...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02584269

    authors: Howe RT

    更新日期:1986-01-01 00:00:00

  • Cellular engineering.

    abstract::Cellular engineering applies the principles and methods of engineering to the problems of cell and molecular biology of both a basic and applied nature. As biomedical engineering has shifted from the organ and tissue level to the cellular and sub-cellular level, cellular engineering has emerged as a new area. A corner...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/BF02367396

    authors: Nerem RM

    更新日期:1991-01-01 00:00:00

  • Pixel-Based DXA-Derived Structural Properties Strongly Correlate with pQCT Measures at the One-Third Distal Femur Site.

    abstract::While bone mineral density has been traditionally used to quantify fracture risk for individuals with spinal cord injuries, recent studies are including engineering measurements such as section modulus and cross sectional moment of inertia. These are almost exclusively calculated by peripheral QCT scanners which, unli...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-017-1796-6

    authors: Baker AM,Wagner DW,Kiratli BJ,Beaupre GS

    更新日期:2017-05-01 00:00:00

  • Fetal Transcatheter Trileaflet Heart Valve Hemodynamics: Implications of Scaling on Valve Mechanics and Turbulence.

    abstract::The scarcity of data available on the best approach for pulmonary fetal valve replacement or implantation necessitate an investigation on whether practices using adult transcatheter valves could be translated to fetal applications. The objective of this study is to evaluate the hemodynamic characteristics and the turb...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02475-3

    authors: Hatoum H,Gooden S,Heitkemper M,Blum KM,Zakko J,Bocks M,Yi T,Wu YL,Wang Y,Breuer CK,Dasi LP

    更新日期:2020-06-01 00:00:00

  • Hemoglobin glycation rate constant in non-diabetic Individuals.

    abstract::The objectives were as follows: (1) estimating mean value of the overall hemoglobin glycation rate constant (k); (2) analyzing inter-individual variability of k; (3) verifying ability of the hemoglobin A1c (HbA1c) formation model to predict changes of HbA1c during red blood cells cultivation in vitro and to reproduce ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-011-0366-6

    authors: Ladyżyński P,Wójcicki JM,Bąk MI,Sabalińska S,Kawiak J,Foltyński P,Krzymień J,Karnafel W

    更新日期:2011-11-01 00:00:00

  • Regional distribution of aerosol deposition in rat lungs using magnetic resonance imaging.

    abstract::The toxic or therapeutic effect of an inhaled aerosol is highly dependent upon the site and extent of deposition in the lung. A novel MRI-based method was used to quantify the spatial distribution of particles in the rat lung. Rats were exposed to 0.95 μm-diameter iron oxide particles in a controlled manner (N = 6) or...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-013-0745-2

    authors: Oakes JM,Scadeng M,Breen EC,Prisk GK,Darquenne C

    更新日期:2013-05-01 00:00:00

  • Can molecular imaging enable personalized diagnostics? An example using magnetomotive photoacoustic imaging.

    abstract::The advantages of photoacoustic (PA) imaging, including low cost, non-ionizing operation, and sub-mm spatial resolution at centimeters depth, make it a promising modality to probe nanoparticle-targeted abnormalities in real time at cellular and molecular levels. However, detecting rare cell types in a heterogeneous ba...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/s10439-013-0901-8

    authors: O'Donnell M,Wei CW,Xia J,Pelivanov I,Jia C,Huang SW,Hu X,Gao X

    更新日期:2013-11-01 00:00:00

  • Body Anthropometry and Bone Strength Conjointly Determine the Risk of Hip Fracture in a Sideways Fall.

    abstract::We hypothesize that variations of body anthropometry, conjointly with the bone strength, determine the risk of hip fracture. To test the hypothesis, we compared, in a simulated sideways fall, the hip impact energy to the energy needed to fracture the femur. Ten femurs from elderly donors were tested using a novel drop...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02682-y

    authors: Palanca M,Perilli E,Martelli S

    更新日期:2020-11-12 00:00:00

  • Sustained Efficacy and Arterial Drug Retention by a Fast Drug Eluting Cross-Linked Fatty Acid Coronary Stent Coating.

    abstract::The long held assumption that sustained drug elution from stent coatings over weeks to months is imperative for clinical efficacy has limited the choice for stent coating materials. We developed and evaluated an omega-3 fatty acid (O3FA) based stent coating that is 85% absorbed and elutes 97% of its Sirolimus analog (...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1435-z

    authors: Artzi N,Tzafriri AR,Faucher KM,Moodie G,Albergo T,Conroy S,Corbeil S,Martakos P,Virmani R,Edelman ER

    更新日期:2016-02-01 00:00:00

  • Simulation of neutrophil deformation and transport in capillaries using newtonian and viscoelastic drop models.

    abstract::It is well known that neutrophils take much longer to traverse the pulmonary capillary bed than erythrocytes, and this is likely due to differences in the structure and rheology of the cells. In this study, we simulate the transit of a neutrophil in a capillary using a Newtonian drop model and a viscoelastic drop mode...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-007-9286-x

    authors: Zhou C,Yue P,Feng JJ

    更新日期:2007-05-01 00:00:00

  • Analog electrical model of the coronary circulation in case of multiple revascularizations.

    abstract::In this work, we propose an analog electrical model of the coronary circulation for patients with obstructive disease undergoing revascularization. In this clinical situation, the collateral circulation to the occluded artery is difficult to ascertain via preoperative measurements and well-developed collaterals might ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-008-9500-5

    authors: Maasrani M,Verhoye JP,Corbineau H,Drochon A

    更新日期:2008-07-01 00:00:00

  • Myofilament kinetics in isometric twitch dynamics.

    abstract::To better understand the relationship between kinetic processes of contraction and the dynamic features of an isometric twitch, studies were conducted using a mathematical model that included: (1) kinetics of cross bridge (XB) cycling; (2) kinetics of thin filament regulatory processes; (3) serial and feedback interac...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1366669

    authors: Campbell KB,Razumova MV,Kirkpatrick RD,Slinker BK

    更新日期:2001-05-01 00:00:00

  • On the Impact of Intraluminal Thrombus Mechanical Behavior in AAA Passive Mechanics.

    abstract::Intraluminal thrombus (ILT) is a pseudo-tissue that develops from coagulated blood, and is found in most abdominal aortic aneurysms (AAAs) of clinically relevant size. A number of studies have suggested that ILT mechanical characteristics may be related to AAA risk of rupture, even though there is still great controve...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1267-x

    authors: Riveros F,Martufi G,Gasser TC,Rodriguez-Matas JF

    更新日期:2015-09-01 00:00:00

  • Biomechanical Properties and Microstructure of Heart Chambers: A Paired Comparison Study in an Ovine Model.

    abstract::Mechanical properties of the cardiac tissue play an important role in normal heart function. The goal of this study was to determine the passive mechanical properties of all heart chambers through a paired comparison study in an ovine model. Ovine heart was used due its physiological and anatomical similarities to hum...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-016-1658-7

    authors: Javani S,Gordon M,Azadani AN

    更新日期:2016-11-01 00:00:00

  • Engineering structurally organized cartilage and bone tissues.

    abstract::The field of tissue engineering promises to deliver biological substitutes to repair or replace tissues in the body that have been injured or diseased. The clinical demand for musculoskeletal tissues is particularly high, especially for cartilage and bone defects. Although they are generally considered biologically si...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1023/b:abme.0000007799.60142.78

    authors: Sharma B,Elisseeff JH

    更新日期:2004-01-01 00:00:00

  • Left-right asymmetry of visual evoked potentials in brain-damaged patients: a mathematical model and experimental results.

    abstract::The left-right asymmetry in the potential amplitude on the scalp was studied in poststroke patients by using flash visual evoked potential (VEP) and a numerical two-dimensional model of the head. The left-right asymmetry of the VEP was measured in three patients after thrombosis, in one after hemorrhage, and in one he...

    journal_title:Annals of biomedical engineering

    pub_type: 临床试验,杂志文章

    doi:10.1007/BF02770997

    authors: Abboud S,Bar L,Rosenfeld M,Ring H,Glass I

    更新日期:1996-01-01 00:00:00

  • A COVID-19 Airway Management Innovation with Pragmatic Efficacy Evaluation: The Patient Particle Containment Chamber.

    abstract::The unique resource constraints, urgency, and virulence of the coronavirus disease 2019 pandemic has sparked immense innovation in the development of barrier devices to protect healthcare providers from infectious airborne particles generated by patients during airway management interventions. Of the existing devices,...

    journal_title:Annals of biomedical engineering

    pub_type: 社论

    doi:10.1007/s10439-020-02599-6

    authors: Maloney LM,Yang AH,Princi RA,Eichert AJ,Hébert DR,Kupec TV,Mertz AE,Vasyltsiv R,Vijaya Kumar TM,Walker GJ,Peralta EJ,Hoffman JL,Yin W,Page CR

    更新日期:2020-10-01 00:00:00

  • Linear homeomorphic models for muscles in the head-neck region.

    abstract::The linear homeomorphic muscle model proposed by Enderle and coworkers for the rectus eye muscle is fitted to reflect the dynamics of muscles in the head-neck complex, specifically in muscles involved in gaze shifts. This parameterization of the model for different muscles in the neck region will serve to drive a 3D d...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-009-9851-6

    authors: Sierra DA,Enderle JD

    更新日期:2010-02-01 00:00:00

  • Constitutive modeling of pia-arachnoid complex.

    abstract::The pia-arachnoid complex (PAC) covering the brain plays an important role in the mechanical response of the brain during impact or inertial loading. Recent studies have revealed the complicated material behavior of the PAC. In this study, the nonlinear viscoelastic, transversely isotropic material properties of the P...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-013-0948-6

    authors: Jin X,Mao H,Yang KH,King AI

    更新日期:2014-04-01 00:00:00