Consistent biomechanical phenotyping of common carotid arteries from seven genetic, pharmacological, and surgical mouse models.

Abstract:

:The continuing lack of longitudinal histopathological and biomechanical data for human arteries in health and disease highlights the importance of studying the many genetic, pharmacological, and surgical models that are available in mice. As a result, there has been a significant increase in the number of reports on the biomechanics of murine arteries over the past decade, particularly for the common carotid artery. Whereas most of these studies have focused on wild-type controls or comparing controls vs. a single model of altered hemodynamics or vascular disease, there is a pressing need to compare results across many different models to understand more broadly the effects of genetic mutations, pharmacological treatments, or surgical alterations on the evolving hemodynamics and the microstructure and biomechanical properties of these vessels. This paper represents a first step toward this goal, that is, a biomechanical phenotyping of common carotid arteries from control mice and seven different mouse models that represent alterations in elastic fiber integrity, collagen remodeling, and smooth muscle cell functionality.

journal_name

Ann Biomed Eng

authors

Bersi MR,Ferruzzi J,Eberth JF,Gleason RL Jr,Humphrey JD

doi

10.1007/s10439-014-0988-6

subject

Has Abstract

pub_date

2014-06-01 00:00:00

pages

1207-23

issue

6

eissn

0090-6964

issn

1573-9686

journal_volume

42

pub_type

杂志文章
  • An ex vivo study of the biological properties of porcine aortic valves in response to circumferential cyclic stretch.

    abstract::Normal physiological mechanical forces cause constant tissue renewal in aortic valve leaflets (AVL) while altered mechanical forces incite changes in their structural and biological properties. The current study aims at characterizing the remodeling properties of AVL subjected to cyclic circumferential stretch in a st...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-006-9167-8

    authors: Balachandran K,Konduri S,Sucosky P,Jo H,Yoganathan AP

    更新日期:2006-11-01 00:00:00

  • Do increased electrogastrographic frequencies always correspond to internal tachygastria?

    abstract::This study was undertaken to investigate the possible origin of some cutaneously recorded higher frequency electrogastrographic signals. Computer modeling of gastric electrical uncoupling was performed using previously described conoidal dipole model. Cutaneous electrogastrograms were simulated after uncoupling was in...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:

    authors: Mintchev MP,Bowes KL

    更新日期:1997-11-01 00:00:00

  • The effect of strain rate on the viscoelastic response of aortic valve tissue: a direct-fit approach.

    abstract::Knowledge of strain-rate sensitivity of soft tissue viscoelastic and nonlinear elastic properties is important for accurate predictions of biomechanical behavior and for quantitative assessment of the effects of disease or surgical/pharmaceutical intervention. Soft tissues are known to exhibit mild rate sensitivity, b...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1023/b:abme.0000012742.01261.b0

    authors: Doehring TC,Carew EO,Vesely I

    更新日期:2004-02-01 00:00:00

  • Theoretical study of the effects of vascular smooth muscle contraction on strain and stress distributions in arteries.

    abstract::To study the effects of smooth muscle contraction and relaxation on the strain and stress distribution in the vascular wall, a mathematical model was proposed. The artery was assumed to be a thick-walled orthotropic tube made of nonlinear, incompressible elastic material. Considering that the contraction of smooth mus...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.191

    authors: Rachev A,Hayashi K

    更新日期:1999-07-01 00:00:00

  • Time-frequency approaches for the detection of interactions and temporal properties in renal autoregulation.

    abstract::We compare the influence of time-frequency methods on analysis of time-varying renal autoregulation properties. Particularly, we examine if detection probabilities are similar for amplitude and frequency modulation for a modulated simulation signal among five time-frequency approaches, and if time-varying changes in s...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-012-0625-1

    authors: Scully CG,Siu KL,Cupples WA,Braam B,Chon KH

    更新日期:2013-01-01 00:00:00

  • Evaluation of three animal models for concussion and serious brain injury.

    abstract::Three animal models were evaluated in this study involving head impacts of the rat, including the Marmarou drop-weight and two momentum-exchange techniques. In series 1, 36 Wistar rats were hit on the side of the free-moving head using Marmarou's 450 g impact mass at 4.4, 5.4, and 6.3 m/s. Head acceleration was measur...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-011-0386-2

    authors: Viano DC,Hamberger A,Bolouri H,Säljö A

    更新日期:2012-01-01 00:00:00

  • A Fluorescence Sensing Method with Reduced DNA Typing and Low-Cost Instrumentation for Detection of Sample Tampering Cases in Urinalysis.

    abstract::This work presents a method to unequivocally detect urine sample tampering in cases where integrity of the sample needs to be verified prior to urinalysis. The technique involves the detection of distinct patterns of a triplex short tandem repeats system in DNA extracted from human urine. The analysis is realized with...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-019-02386-y

    authors: Pires NMM,Dong T,Yang Z,Santos SMB

    更新日期:2020-02-01 00:00:00

  • Design considerations for a microfluidic device to quantify the platelet adhesion to collagen at physiological shear rates.

    abstract::Accurate assessment of blood platelet function is essential in understanding thrombus formation which plays a central role in cardiovascular disease. Parallel plate flow chambers have been widely used as they allow for platelet adhesion on a collagen surface at physiologically relevant fluid mechanical forces. Standar...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-009-9708-z

    authors: Sarvepalli DP,Schmidtke DW,Nollert MU

    更新日期:2009-07-01 00:00:00

  • Bimodal analysis of mammary epithelial cell migration in two dimensions.

    abstract::Cell migration paths of mammary epithelial cells (expressing different versions of the promigratory tyrosine kinase receptor Her2/Neu) were analyzed within a bimodal framework that is a generalization of the run-and-tumble description applicable to bacterial migration. The mammalian cell trajectories were segregated i...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-008-9592-y

    authors: Potdar AA,Lu J,Jeon J,Weaver AM,Cummings PT

    更新日期:2009-01-01 00:00:00

  • Delayed activation and retrograde propagation in cardiac muscle: implication of virtual electrode effects.

    abstract::Point cathodal stimulation of cardiac tissue was shown previously to produce both a dog-bone shaped virtual cathode transverse to the muscle fibers and two longitudinal virtual anodes. We hypothesize that virtual anodes can cause a region of delayed activation, separating two regions of early activation caused by the ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1326029

    authors: Wu J,Roden DM,Wikswo JP Jr

    更新日期:2000-11-01 00:00:00

  • Second harmonic generation imaging and Fourier transform spectral analysis reveal damage in fatigue-loaded tendons.

    abstract::Conventional histologic methods provide valuable information regarding the physical nature of damage in fatigue-loaded tendons, limited to thin, two-dimensional sections. We introduce an imaging method that characterizes tendon microstructure three-dimensionally and develop quantitative, spatial measures of damage for...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-9976-7

    authors: Fung DT,Sereysky JB,Basta-Pljakic J,Laudier DM,Huq R,Jepsen KJ,Schaffler MB,Flatow EL

    更新日期:2010-05-01 00:00:00

  • Effects of Chemically Doped Bioactive Borate Glass on Neuron Regrowth and Regeneration.

    abstract::Peripheral nerve injuries present challenges to regeneration. Currently, the gold standard for nerve repair is an autograft that results in another region of the body suffering nerve damage. Previously, bioactive borate glass (BBG) has been studied in clinical trials to treat patients with non-healing wounds, and we h...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-016-1689-0

    authors: Gupta B,Papke JB,Mohammadkhah A,Day DE,Harkins AB

    更新日期:2016-12-01 00:00:00

  • A Battery-Powered Ankle Exoskeleton Improves Gait Mechanics in a Feasibility Study of Individuals with Cerebral Palsy.

    abstract::Neuromuscular impairment associated with cerebral palsy (CP) often leads to life-long walking deficits. Our goal was to evaluate the ability of a novel untethered wearable ankle exoskeleton to reduce the severity of gait pathology from CP. In this clinical feasibility study of five individuals with CP, we used instrum...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-019-02237-w

    authors: Lerner ZF,Harvey TA,Lawson JL

    更新日期:2019-06-01 00:00:00

  • A finite volume method for modeling discontinuous electrical activation in cardiac tissue.

    abstract::This paper describes a finite volume method for modeling electrical activation in a sample of cardiac tissue using the bidomain equations. Microstructural features to the level of cleavage planes between sheets of myocardial fibers in the tissue are explicitly represented. The key features of this implementation compa...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-005-1434-6

    authors: Trew M,Le Grice I,Smaill B,Pullan A

    更新日期:2005-05-01 00:00:00

  • Progression of abdominal aortic aneurysm towards rupture: refining clinical risk assessment using a fully coupled fluid-structure interaction method.

    abstract::Rupture of abdominal aortic aneurysm (AAA) is associated with high mortality rates. Risk of rupture is multi-factorial involving AAA geometric configuration, vessel tortuosity, and the presence of intraluminal pathology. Fluid structure interaction (FSI) simulations were conducted in patient based computed tomography ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-014-1224-0

    authors: Xenos M,Labropoulos N,Rambhia S,Alemu Y,Einav S,Tassiopoulos A,Sakalihasan N,Bluestein D

    更新日期:2015-01-01 00:00:00

  • Myofiber ellipticity as an explanation for transverse asymmetry of skeletal muscle diffusion MRI in vivo signal.

    abstract::Due to its unique non-invasive microstructure probing capabilities, diffusion tensor imaging (DTI) constitutes a valuable tool in the study of fiber orientation in skeletal muscles. By implementing a DTI sequence with judiciously chosen directional encoding to quantify in vivo the microarchitectural properties in the ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-009-9783-1

    authors: Karampinos DC,King KF,Sutton BP,Georgiadis JG

    更新日期:2009-12-01 00:00:00

  • Fabrication and mechanical evaluation of anatomically-inspired quasilaminate hydrogel structures with layer-specific formulations.

    abstract::A major tissue engineering challenge is the creation of multilaminate scaffolds with layer-specific mechanical properties representative of native tissues, such as heart valve leaflets, blood vessels, and cartilage. For this purpose, poly(ethylene glycol) diacrylate (PEGDA) hydrogels are attractive materials due to th...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-012-0666-5

    authors: Tseng H,Cuchiara ML,Durst CA,Cuchiara MP,Lin CJ,West JL,Grande-Allen KJ

    更新日期:2013-02-01 00:00:00

  • Automatic Model Generation Framework for Computational Simulation of Cochlear Implantation.

    abstract::Recent developments in computational modeling of cochlear implantation are promising to study in silico the performance of the implant before surgery. However, creating a complete computational model of the patient's anatomy while including an external device geometry remains challenging. To address such a challenge, ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1541-y

    authors: Mangado N,Ceresa M,Duchateau N,Kjer HM,Vera S,Dejea Velardo H,Mistrik P,Paulsen RR,Fagertun J,Noailly J,Piella G,González Ballester MÁ

    更新日期:2016-08-01 00:00:00

  • LDL decreases the membrane compliance and cell adhesion of endothelial cells under fluid shear stress.

    abstract::Atherosclerosis is an inflammatory disease of large and medium sized arteriole walls that is precipitated by elevated levels of low-density lipoprotein (LDL) cholesterol in the blood. However, the mechanisms that lead to the initiation of atherosclerosis are not fully understood. In this study, endothelial cells (ECs)...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-012-0677-2

    authors: Wei D,Chen Y,Tang C,Huang H,Liu L,Wang Z,Li R,Wang G

    更新日期:2013-03-01 00:00:00

  • Prediction of hip fracture can be significantly improved by a single biomedical indicator.

    abstract::Femoral neck fractures are a relevant clinical and social problem. The aim of this study was to improve the prediction of patients at-risk of femoral neck fracture with respect to the current densitometric-based methods. In particular, finite element models were used to assess the prediction accuracy obtained by combi...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1495866

    authors: Testi D,Viceconti M,Cappello A,Gnudi S

    更新日期:2002-06-01 00:00:00

  • Biomechanical characterization of internal layer subfailure in blunt arterial injury.

    abstract::Blunt carotid artery injuries occur in 0.3% of blunt injured patients and may lead to devastating neurological consequences. However, arterial mechanics leading to internal layer subfailure have not been quantified. Twenty-two human carotid artery segments and 18 porcine thoracic aorta segments were opened to expose t...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-006-9229-y

    authors: Stemper BD,Yoganandan N,Sinson GP,Gennarelli TA,Stineman MR,Pintar FA

    更新日期:2007-02-01 00:00:00

  • Development of a Three-Dimensional Adipose Tissue Model for Studying Embryonic Exposures to Obesogenic Chemicals.

    abstract::Obesity is a rising issue especially in the United States that can lead to heart problems, type II diabetes, and respiratory problems. Since the 1970s, obesity rates in the United States have more than doubled in adults and children. Recent evidence suggests that exposure to certain chemicals, termed "obesogens," in u...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-016-1752-x

    authors: Wang RY,Abbott RD,Zieba A,Borowsky FE,Kaplan DL

    更新日期:2017-07-01 00:00:00

  • Modeling Human Volunteers in Multidirectional, Uni-axial Sled Tests Using a Finite Element Human Body Model.

    abstract::A goal of the Human Research Program at National Aeronautics and Space Administration (NASA) is to analyze and mitigate the risk of occupant injury due to dynamic loads. Experimental tests of human subjects and biofidelic anthropomorphic test devices provide valuable kinematic and kinetic data related to injury risk e...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-018-02147-3

    authors: Gaewsky JP,Jones DA,Ye X,Koya B,McNamara KP,Gayzik FS,Weaver AA,Putnam JB,Somers JT,Stitzel JD

    更新日期:2019-02-01 00:00:00

  • An experimental and numerical investigation of head dynamics due to stick impacts in girls' lacrosse.

    abstract::A method of investigating head acceleration and intracranial dynamics from stick impacts in girls' and women's lacrosse was developed using headform impact experiments and a finite element head model. Assessing the likelihood of head injury due to stick-head impacts is of interest in girls' and women's lacrosse due to...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-014-1091-8

    authors: Morse JD,Franck JA,Wilcox BJ,Crisco JJ,Franck C

    更新日期:2014-12-01 00:00:00

  • Role of vortices in growth of microbubbles at mitral mechanical heart valve closure.

    abstract::This study is aimed at refining our understanding of the role of vortex formation at mitral mechanical heart valve (MHV) closure and its association with the high intensity transient signals (HITS) seen in echocardiographic studies with MHV recipients. Previously reported numerical results described a twofold process ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-007-9293-y

    authors: Rambod E,Beizai M,Sahn DJ,Gharib M

    更新日期:2007-07-01 00:00:00

  • Estimating the parameter distributions of defibrillation shock efficacy curves in a large population.

    abstract::Defibrillation efficacy testing is a common procedure at defibrillator implantation, with the objective to ensure that each patient receives a system with adequate shock efficacy. In this study, defibrillation shock efficacy as a function of shock energy was modeled by a dose response relationship. The frequency distr...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-009-9890-z

    authors: Smits K,Virag N

    更新日期:2010-04-01 00:00:00

  • The transport profile of cytokines in epidermal equivalents subjected to mechanical loading.

    abstract::Pressure ulcer risk assessment might be optimized by incorporating the soft tissue reaction to mechanical loading in the currently used risk assessment scales. Cytokines, like IL-1alpha, IL-1RA, IL-8, and TNF-alpha, might be used to determine this tissue reaction, since they are released after 24 h of mechanical loadi...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-009-9652-y

    authors: Cornelissen LH,Bronneberg D,Bader DL,Baaijens FP,Oomens CW

    更新日期:2009-05-01 00:00:00

  • Fluid dynamic assessment of three polymeric heart valves using particle image velocimetry.

    abstract::Polymeric heart valves have the potential to reduce thrombogenic complications associated with current mechanical valves and overcome fatigue-related problems experienced by bioprosthetic valves. In this paper we characterize the in vitro velocity and Reynolds Shear Stress (RSS) fields inside and downstream of three d...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-006-9117-5

    authors: Leo HL,Dasi LP,Carberry J,Simon HA,Yoganathan AP

    更新日期:2006-06-01 00:00:00

  • Perspectives on Bioengineering Clinical Immersion: History, Innovation, and Impact.

    abstract::Opportunities to provide clinical immersion experiences to bioengineering undergraduate students have expanded over the last several years. These programs allow students to observe the clinical environment in order to better understand workflow processes, the context in which medical equipment is used, and identify un...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02508-x

    authors: Kotche M,Felder AE,Wilkens K,Stirling S

    更新日期:2020-09-01 00:00:00

  • Micro-flow visualization of red blood cell-enhanced platelet concentration at sudden expansion.

    abstract::Microscopic steps and crevices are inevitable features within prosthetic blood-contacting devices. This study aimed to elucidate the thrombogenicity of the associated microscopic flow features by studying the transport of fluorescent platelet-sized particles in a suspension of red blood cells (RBCs) flowing through a ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-008-9494-z

    authors: Zhao R,Marhefka JN,Shu F,Hund SJ,Kameneva MV,Antaki JF

    更新日期:2008-07-01 00:00:00