Design considerations for a microfluidic device to quantify the platelet adhesion to collagen at physiological shear rates.

Abstract:

:Accurate assessment of blood platelet function is essential in understanding thrombus formation which plays a central role in cardiovascular disease. Parallel plate flow chambers have been widely used as they allow for platelet adhesion on a collagen surface at physiologically relevant fluid mechanical forces. Standard parallel plate flow chambers typically need several milliliters of blood, which is substantially more than can be obtained from small animals. We designed, fabricated, and assessed the functionality of a microfluidic channel with a width of 500 microm and a height of 50 microm in which a wall shear rate of 1000 s(-1) can be achieved with a flow rate of 15 microL/min. The velocity distribution in the microchannel predicted from the equations of motion was compared to experimentally measured velocities of fluorescent beads. This analysis showed that the motion of beads was quite similar to the predicted motion. Adhesion of platelets from whole blood at a shear rate of 1000 s(-1) onto a collagen surface using the microfluidic flow channel was qualitatively similar to platelet adhesion observed with a standard sized parallel plate flow chamber. After 5 min flow the surface coverage of platelets in the microfluidic device was about 55% while in a traditional size flow chamber the surface coverage was about 75%. This suggests that the microfluidic flow chamber can be used to quantify platelet adhesion for system where only very small amounts of blood are available.

journal_name

Ann Biomed Eng

authors

Sarvepalli DP,Schmidtke DW,Nollert MU

doi

10.1007/s10439-009-9708-z

subject

Has Abstract

pub_date

2009-07-01 00:00:00

pages

1331-41

issue

7

eissn

0090-6964

issn

1573-9686

journal_volume

37

pub_type

杂志文章
  • Osteochondral interface tissue engineering using macroscopic gradients of bioactive signals.

    abstract::Continuous gradients exist at osteochondral interfaces, which may be engineered by applying spatially patterned gradients of biological cues. In the present study, a protein-loaded microsphere-based scaffold fabrication strategy was applied to achieve spatially and temporally controlled delivery of bioactive signals i...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-0028-0

    authors: Dormer NH,Singh M,Wang L,Berkland CJ,Detamore MS

    更新日期:2010-06-01 00:00:00

  • Computational Modelling of Multi-folded Balloon Delivery Systems for Coronary Artery Stenting: Insights into Patient-Specific Stent Malapposition.

    abstract::Despite the clinical effectiveness of coronary artery stenting, percutaneous coronary intervention or "stenting" is not free of complications. Stent malapposition (SM) is a common feature of "stenting" particularly in challenging anatomy, such as that characterized by long, tortuous and bifurcated segments. SM is an i...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-014-1237-8

    authors: Ragkousis GE,Curzen N,Bressloff NW

    更新日期:2015-08-01 00:00:00

  • A review of return to play issues and sports-related concussion.

    abstract::Mild traumatic brain injury in sports has become a significant public health concern which has not only received the general public's attention through multiple news media stories involving athletic concussions, but has also resulted in local, state, and national legislative efforts to improve recognition and manageme...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/s10439-011-0413-3

    authors: Doolan AW,Day DD,Maerlender AC,Goforth M,Gunnar Brolinson P

    更新日期:2012-01-01 00:00:00

  • A Non-Invasive Material Characterization Framework for Bioprosthetic Heart Valves.

    abstract::Computational modeling and simulation has become more common in design and development of bioprosthetic heart valves. To have a reliable computational model, considering accurate mechanical properties of biological soft tissue is one of the most important steps. The goal of this study was to present a non-invasive mat...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-018-02129-5

    authors: Abbasi M,Barakat MS,Dvir D,Azadani AN

    更新日期:2019-01-01 00:00:00

  • An evaluation of population D-optimal designs via pharmacokinetic simulations.

    abstract::One goal of large scale clinical trials is to determine how a drug is processed by, and cleared from, the human body [i.e., its pharmacokinetic (PK) properties] and how these PK properties differ between individuals in a population (i.e., its population PK properties). Due to the high cost of these studies and the lim...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1533074

    authors: Hooker AC,Foracchia M,Dodds MG,Vicini P

    更新日期:2003-01-01 00:00:00

  • The tendon injury response is influenced by decorin and biglycan.

    abstract::Defining the constituent regulatory molecules in tendon is critical to understanding the process of tendon repair and instructive to the development of novel treatment modalities. The purpose of this study is to define the structural, expressional, and mechanical changes in the tendon injury response, and elucidate th...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-013-0915-2

    authors: Dunkman AA,Buckley MR,Mienaltowski MJ,Adams SM,Thomas SJ,Satchell L,Kumar A,Pathmanathan L,Beason DP,Iozzo RV,Birk DE,Soslowsky LJ

    更新日期:2014-03-01 00:00:00

  • 3D Printed Vascular Networks Enhance Viability in High-Volume Perfusion Bioreactor.

    abstract::There is a significant clinical need for engineered bone graft substitutes that can quickly, effectively, and safely repair large segmental bone defects. One emerging field of interest involves the growth of engineered bone tissue in vitro within bioreactors, the most promising of which are perfusion bioreactors. Usin...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-016-1662-y

    authors: Ball O,Nguyen BB,Placone JK,Fisher JP

    更新日期:2016-12-01 00:00:00

  • Fibroblast morphology on dynamic softening of hydrogels.

    abstract::Despite cellular environments having dynamic characteristics, many laboratories utilized static polyacrylamide hydrogels to study the ECM-cell relationship. To attain a more in vivo like environment, we have developed a dynamic, DNA-crosslinked hydrogel (DNA gel). Through the controlled delivery of DNA, we can tempora...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-011-0483-2

    authors: Previtera ML,Trout KL,Verma D,Chippada U,Schloss RS,Langrana NA

    更新日期:2012-05-01 00:00:00

  • The effect of head rotation on the geometry and hemodynamics of healthy vertebral arteries.

    abstract::The geometric and hemodynamic characteristics of the left and right vertebral arteries (LVA, RVA) of six healthy volunteers were investigated for the supine (S) and the prone position (P) a common sleeping posture with head rotation. MRI images were used to reconstruct the subject specific three-dimensional solid mode...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1340-5

    authors: Aristokleous N,Seimenis I,Georgiou GC,Nicolaides A,Anayiotos AS

    更新日期:2015-06-01 00:00:00

  • 3D Printing of Calcium Phosphate Ceramics for Bone Tissue Engineering and Drug Delivery.

    abstract::Additive manufacturing, also known as 3D printing, has emerged over the past 3 decades as a disruptive technology for rapid prototyping and manufacturing. Vat polymerization, powder bed fusion, material extrusion, and binder jetting are distinct technologies of additive manufacturing, which have been used in a wide va...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/s10439-016-1678-3

    authors: Trombetta R,Inzana JA,Schwarz EM,Kates SL,Awad HA

    更新日期:2017-01-01 00:00:00

  • Insulin minimal model indexes and secretion: proper handling of uncertainty by a Bayesian approach.

    abstract::The identification of the insulin minimal model (MM) for the estimation of insulin secretion rate (ISR) and physiological indexes (e.g. beta-cell sensitivity) requires the knowledge of C-peptide (CP) kinetics. The four parameters of the two-compartment model of CP kinetics in a given individual can be derived either f...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1023/b:abme.0000032465.75888.91

    authors: Magni P,Sparacino G,Bellazzi R,Toffolo GM,Cobelli C

    更新日期:2004-07-01 00:00:00

  • Modeling Human Volunteers in Multidirectional, Uni-axial Sled Tests Using a Finite Element Human Body Model.

    abstract::A goal of the Human Research Program at National Aeronautics and Space Administration (NASA) is to analyze and mitigate the risk of occupant injury due to dynamic loads. Experimental tests of human subjects and biofidelic anthropomorphic test devices provide valuable kinematic and kinetic data related to injury risk e...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-018-02147-3

    authors: Gaewsky JP,Jones DA,Ye X,Koya B,McNamara KP,Gayzik FS,Weaver AA,Putnam JB,Somers JT,Stitzel JD

    更新日期:2019-02-01 00:00:00

  • Sustained Efficacy and Arterial Drug Retention by a Fast Drug Eluting Cross-Linked Fatty Acid Coronary Stent Coating.

    abstract::The long held assumption that sustained drug elution from stent coatings over weeks to months is imperative for clinical efficacy has limited the choice for stent coating materials. We developed and evaluated an omega-3 fatty acid (O3FA) based stent coating that is 85% absorbed and elutes 97% of its Sirolimus analog (...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1435-z

    authors: Artzi N,Tzafriri AR,Faucher KM,Moodie G,Albergo T,Conroy S,Corbeil S,Martakos P,Virmani R,Edelman ER

    更新日期:2016-02-01 00:00:00

  • Mechanical behavior of vascular smooth muscle in cylindrical segments of arteries in vitro.

    abstract::Vascular smooth muscle mechanics have been studied in vitro in cylindrical segments of dog carotid artery, human internal mammary artery, and human saphenous vein. Such cylindrical preparations maintain normal vessel geometry and also permit correlation of mechanical phenomena with transmural pressure. These studies s...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02363919

    authors: Dobrin PB

    更新日期:1984-01-01 00:00:00

  • A computational study of the effect of false vocal folds on glottal flow and vocal fold vibration during phonation.

    abstract::The false vocal folds are believed to be components of the acoustic filter that is responsible for shaping the voice. However, the effects of false vocal folds on the vocal fold vibration and the glottal aerodynamic during phonation remain unclear. This effect has implications for computational modeling of phonation a...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-008-9630-9

    authors: Zheng X,Bielamowicz S,Luo H,Mittal R

    更新日期:2009-03-01 00:00:00

  • Evaluating the Impact of Calcification on Plaque Vulnerability from the Aspect of Mechanical Interaction Between Blood Flow and Artery Based on MRI.

    abstract::Acute cerebral ischemic events and thrombosis are associated with the rupture/erosion of carotid atherosclerotic plaques. The aim of the present study was to determine the impact of calcification deposition on the wall shear stress (WSS) and stresses within the plaques using 3D fluid-structure interaction (FSI) models...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02655-1

    authors: Benitez J,Fontanarosa D,Wang J,Paritala PK,McGahan T,Lloyd T,Li Z

    更新日期:2020-10-20 00:00:00

  • Two-dimensional dynamic simulation of platelet activation during mechanical heart valve closure.

    abstract::A major drawback in the operation of mechanical heart valve prostheses is thrombus formation in the near valve region. Detailed flow analysis in this region during the valve closure phase is of interest in understanding the relationship between shear stress and platelet activation. A fixed-grid Cartesian mesh flow sol...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-006-9194-5

    authors: Krishnan S,Udaykumar HS,Marshall JS,Chandran KB

    更新日期:2006-10-01 00:00:00

  • Rib Geometry Explains Variation in Dynamic Structural Response: Potential Implications for Frontal Impact Fracture Risk.

    abstract::The human thorax is commonly injured in motor vehicle crashes, and despite advancements in occupant safety rib fractures are highly prevalent. The objective of this study was to quantify the ability of gross and cross-sectional geometry, separately and in combination, to explain variation of human rib structural prope...

    journal_title:Annals of biomedical engineering

    pub_type: 临床试验,杂志文章

    doi:10.1007/s10439-017-1850-4

    authors: Murach MM,Kang YS,Goldman SD,Schafman MA,Schlecht SH,Moorhouse K,Bolte JH 4th,Agnew AM

    更新日期:2017-09-01 00:00:00

  • Comparison of Covered Laser-cut and Braided Respiratory Stents: From Bench to Pre-Clinical Testing.

    abstract::Lung cancer patients often suffer from severe airway stenosis, the symptoms of which can be relieved by the implantation of stents. Different respiratory stents are commercially available, but the impact of their mechanical performance on tissue responses is not well understood. Two novel laser-cut and hand-braided ni...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-019-02278-1

    authors: Thiebes AL,McGrath DJ,Kelly N,Sweeney CA,Kurtenbach K,Gesché VN,Clauser J,O'Brien B,Bruzzi M,McHugh PE,Jockenhoevel S,Cornelissen CG

    更新日期:2019-08-01 00:00:00

  • Myofilament kinetics in isometric twitch dynamics.

    abstract::To better understand the relationship between kinetic processes of contraction and the dynamic features of an isometric twitch, studies were conducted using a mathematical model that included: (1) kinetics of cross bridge (XB) cycling; (2) kinetics of thin filament regulatory processes; (3) serial and feedback interac...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1366669

    authors: Campbell KB,Razumova MV,Kirkpatrick RD,Slinker BK

    更新日期:2001-05-01 00:00:00

  • Net change in periosteal strain during stance shift loading after surgery correlates to rapid de novo bone generation in critically sized defects.

    abstract::In an ovine femur model, proliferative woven bone fills critically sized defects enveloped by periosteum within 2 weeks of treatment with the one-stage bone-transport surgery. We hypothesize that mechanical loading modulates this process. Using high-definition optical strain measurements we determined prevailing perio...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-0242-9

    authors: McBride SH,Dolejs S,Brianza S,Knothe U,Knothe Tate ML

    更新日期:2011-05-01 00:00:00

  • Microprocessor control of a ventricular volume servo-pump.

    abstract::Measurement of the instantaneous pressure-volume relationship of the left ventricle is fundamental to the study of ventricular mechanics. In order to effectively investigate this relationship, it is necessary to vary and control the time course of ventricular volume change in a variety of prescribed manners. In the pa...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02367387

    authors: Sunagawa K,Lim KO,Burkhoff D,Sagawa K

    更新日期:1982-01-01 00:00:00

  • Geometric and flow features of type B aortic dissection: initial findings and comparison of medically treated and stented cases.

    abstract::Uncomplicated acute type B aortic dissections are usually treated medically, but they can become acutely complicated by rapid expansion, rupture and malperfusion syndromes and in the longer term by chronic dilatation and aortic aneurysm formation. The objective of this study is to use computational fluid dynamics reco...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-014-1075-8

    authors: Cheng Z,Wood NB,Gibbs RG,Xu XY

    更新日期:2015-01-01 00:00:00

  • A regional blood flow model for β2-microglobulin kinetics and for simulating intra-dialytic exercise effect.

    abstract::A kinetic model based on first principles, for β(2)-microglobulin, is presented to obtain precise parameter estimates for individual patient. To reduce the model complexity, the number of model parameters was reduced using a priori identifiability analysis. The model validity was confirmed with the clinical data of te...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-011-0383-5

    authors: Maheshwari V,Samavedham L,Rangaiah GP

    更新日期:2011-12-01 00:00:00

  • Selective stimulation of latissimus dorsi muscle for cardiac assist.

    abstract::The contractile power of the latissimus dorsi muscle (LDM) is used in skeletal muscle cardiac assist (SMCA) to augment the blood pumping ability of a failing heart. The LDM has three anatomically distinct, independently innervate segments-the transverse, oblique, and lateral. There are potential advantages to selectiv...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.164

    authors: Thompson DR,Michele JJ,Cheever EA,George DT

    更新日期:1999-01-01 00:00:00

  • Bioengineering the skin-implant interface: the use of regenerative therapies in implanted devices.

    abstract::This discussion and review article focuses on the possible use of regenerative techniques applied to the interfaces between skin and medical implants. As is widely known, the area of contact between an implant and the skin--the skin-implant interface--is prone to recurrent and persistent problems originated from the l...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/s10439-010-9937-1

    authors: Peramo A,Marcelo CL

    更新日期:2010-06-01 00:00:00

  • Intelligent multichannel stimulator for the study of cardiac arrhythmias.

    abstract::An intelligent multichannel stimulator (IMS) has been designed and built for use in a cardiac research environment. The device is capable of measuring and responding to cardiac electrophysiological phenomena in real time with carefully timed and placed electrical stimuli. The system consists of 16 channels of sense/st...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1451077

    authors: Johnson PL,Newton JC,Rollins DL,Knisley SB,Ideker RE,Smith WM

    更新日期:2002-02-01 00:00:00

  • Quadratic phase coupling as a quantitative measure for the developing hippocampal formation.

    abstract::This paper presents the bispectral analysis of the ontogeny of the hippocampal EEG recorded from the dentate gyrus and CA1, the primary sites that generate theta (theta) rhythm. The hippocampal EEG was collected during the vigilance state of rapid eye movement (REM) sleep of freely moving rats at 15, 30 and 90 days of...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.43

    authors: Ning T,Bronzino JD

    更新日期:1998-07-01 00:00:00

  • Machine Learning Classification of Verified Head Impact Exposure Strengthens Associations with Brain Changes.

    abstract::Cumulative exposure to head impacts during contact sports can elicit potentially deleterious brain white matter alterations in young athletes. Head impact exposure is commonly quantified using wearable sensors; however, these sensors tend to overestimate the number of true head impacts that occur and may obfuscate pot...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02662-2

    authors: DiCesare CA,Green B,Yuan W,Diekfuss JA,Barber Foss KD,Dudley J,Qin Y,Wang P,Myer GD

    更新日期:2020-12-01 00:00:00

  • A numerical implementation to predict residual strains from the homogeneous stress hypothesis with application to abdominal aortic aneurysms.

    abstract::Wall stress analysis of abdominal aortic aneurysm (AAA) is a promising method of identifying AAAs at high risk of rupture. However, neglecting residual strains (RS) in the load-free configuration of patient-specific finite element analysis models is a sever limitation that strongly affects the computed wall stresses. ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-013-0749-y

    authors: Polzer S,Bursa J,Gasser TC,Staffa R,Vlachovsky R

    更新日期:2013-07-01 00:00:00