Mesh Convergence Behavior and the Effect of Element Integration of a Human Head Injury Model.

Abstract:

:Numerous head injury models exist that vary in mesh density by orders of magnitude. A careful study of the mesh convergence behavior is necessary, especially in terms of strain most relevant to brain injury. To this end, as well as to investigate the effect of element integration scheme on simulated strains, we re-meshed the Worcester Head Injury Model at five mesh densities (~ 7.2-1000 k high-quality hexahedral elements of the brain). Results from explicit dynamic simulations of three cadaveric impacts and an in vivo head rotation were compared. First, scalar metrics of the whole brain only considering magnitude were used, including peak maximum principal strain and population-based median strain. They were further extended to deep white matter regions and the entire brain elements, respectively, to form two "response vectors" to account for both magnitude and distribution. Using benchmark enhanced full-integration elements (C3D8I), a minimum of 202.8 k brain elements were necessary to converge for response vectors of the deep white matter regions. This model was further used to simulate with reduced integration (C3D8R). We found that hourglass energy higher than the common rule of thumb (e.g., up to 44.38% vs. < 10% of internal energy) was necessary to maintain comparable strain relative to C3D8I. Based on these results, it is recommended that a human head injury model should have a minimum number of 202.8 k elements, or an average element size of no larger than 1.8 mm, for the brain. C3D8R formulation with relax stiffness hourglass control using a high scaling factor is also recommended to achieve sufficient accuracy without substantial computational cost.

journal_name

Ann Biomed Eng

authors

Zhao W,Ji S

doi

10.1007/s10439-018-02159-z

subject

Has Abstract

pub_date

2019-02-01 00:00:00

pages

475-486

issue

2

eissn

0090-6964

issn

1573-9686

pii

10.1007/s10439-018-02159-z

journal_volume

47

pub_type

杂志文章
  • The effect of strain rate on the viscoelastic response of aortic valve tissue: a direct-fit approach.

    abstract::Knowledge of strain-rate sensitivity of soft tissue viscoelastic and nonlinear elastic properties is important for accurate predictions of biomechanical behavior and for quantitative assessment of the effects of disease or surgical/pharmaceutical intervention. Soft tissues are known to exhibit mild rate sensitivity, b...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1023/b:abme.0000012742.01261.b0

    authors: Doehring TC,Carew EO,Vesely I

    更新日期:2004-02-01 00:00:00

  • Fatigue of Metallic Stents: From Clinical Evidence to Computational Analysis.

    abstract::The great success of stents in treating cardiovascular disease is actually undermined by their long-term fatigue failure. The high variability of stent failure incidence suggests that it is due to several correlated aspects, such as loading conditions, material properties, component design, surgical procedure, and pat...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1447-8

    authors: Auricchio F,Constantinescu A,Conti M,Scalet G

    更新日期:2016-02-01 00:00:00

  • Retinal vascular permeability determined by dual-tracer fluorescence angiography.

    abstract::Diabetic retinopathy is the leading cause of blindness in working age individuals in the United States. Breakdown of the blood-retinal barrier is one of the earliest events in the progression of diabetic retinopathy. Ideally, therapeutic measures would be directed at this early stage, but there are few sensitive, quan...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1385809

    authors: Russ PK,Gaylord GM,Haselton FR

    更新日期:2001-08-01 00:00:00

  • Estimation of Reynolds shear stresses during pulsatile flow in the region of aortic valves.

    abstract::Some investigators have attempted to estimate the Reynolds shear stress on the basis of a single component of velocity. The purpose of this investigation is to determine the validity of such estimates in a complex flow field, such as occurs in the cardiovascular system in the region of the aortic valve. Turbulent velo...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02371247

    authors: Walburn FJ,Sabbah HN,Stein PD

    更新日期:1985-01-01 00:00:00

  • Parametric comparisons of intracranial mechanical responses from three validated finite element models of the human head.

    abstract::A number of human head finite element (FE) models have been developed from different research groups over the years to study the mechanisms of traumatic brain injury. These models can vary substantially in model features and parameters, making it important to evaluate whether simulation results from one model are read...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-013-0907-2

    authors: Ji S,Ghadyani H,Bolander RP,Beckwith JG,Ford JC,McAllister TW,Flashman LA,Paulsen KD,Ernstrom K,Jain S,Raman R,Zhang L,Greenwald RM

    更新日期:2014-01-01 00:00:00

  • Comparison of Laboratory and On-Field Performance of American Football Helmets.

    abstract::The relationship between laboratory and on-field performance of football helmets was assessed for 31 football helmet models selected from those worn by players in the 2015-2019 National Football League (NFL) seasons. Linear impactor tests were conducted with helmets placed on an instrumented Hybrid III head and neck a...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02627-5

    authors: Bailey AM,McMurry TL,Cormier JM,Funk JR,Crandall JR,Mack CD,Myers BS,Arbogast KB

    更新日期:2020-11-01 00:00:00

  • Resistances and compliances of a compartmental model of the cerebrovascular system.

    abstract::A lumped parameter compartmental model for the nonsteady flow of the cerebrovascular fluid is constructed. The model assumes constant resistances that relate fluid flux to pressure gradients, and compliances between compartments that relate fluid accumulation to rate of pressure changes. Resistances are evaluated by u...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02364270

    authors: Sorek S,Bear J,Karni Z

    更新日期:1989-01-01 00:00:00

  • Machine Learning Classification of Verified Head Impact Exposure Strengthens Associations with Brain Changes.

    abstract::Cumulative exposure to head impacts during contact sports can elicit potentially deleterious brain white matter alterations in young athletes. Head impact exposure is commonly quantified using wearable sensors; however, these sensors tend to overestimate the number of true head impacts that occur and may obfuscate pot...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02662-2

    authors: DiCesare CA,Green B,Yuan W,Diekfuss JA,Barber Foss KD,Dudley J,Qin Y,Wang P,Myer GD

    更新日期:2020-12-01 00:00:00

  • Large-scale 3-D geometric reconstruction of the porcine coronary arterial vasculature based on detailed anatomical data.

    abstract::The temporal and spatial distribution of coronary blood flow, pressure, and volume are determined by the branching pattern and three-dimensional (3-D) geometry of the coronary vasculature, and by the mechanics of heart wall and vascular tone. Consequently, a realistic simulation of coronary blood flow requires, as a f...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-005-7544-3

    authors: Kaimovitz B,Lanir Y,Kassab GS

    更新日期:2005-11-01 00:00:00

  • Quantification of rigidity in Parkinson's disease.

    abstract::In this paper, a new method for quantification of rigidity in elbow joint of Parkinsonian patients is introduced. One of the most known syndromes in Parkinson's disease (PD) is increased passive stiffness in muscles, which leads to rigidity in joints. Clinical evaluation of stiffness in wrist and/or elbow, commonly us...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-007-9379-6

    authors: Sepehri B,Esteki A,Ebrahimi-Takamjani E,Shahidi GA,Khamseh F,Moinodin M

    更新日期:2007-12-01 00:00:00

  • Fluid flow-induced calcium response in early or late differentiated osteoclasts.

    abstract::Intracellular calcium oscillation caused by receptor activator of nuclear factor kappa-B ligand has been demonstrated to promote the differentiation of osteoclasts. Osteoclasts are recruited on the surface of trabeculae, and are exposed to fluid flow caused by the deformation of the bone matrix. However, the roles of ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-012-0554-z

    authors: Li P,Hu M,Sun S,Zhang Y,Gao Y,Long M,Huo B,Zhang D

    更新日期:2012-09-01 00:00:00

  • A novel approach to track fetal movement using multi-sensor magnetocardiographic recordings.

    abstract::Changes in fetal magnetocardiographic (fMCG) signals are indicators for fetal body movement. We propose a novel approach to reliably extract fetal body movements based on the field strength of the fMCG signal independent of its frequency. After attenuating the maternal MCG, we use a Hilbert transform approach to ident...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-0231-z

    authors: Govindan RB,Vairavan S,Ulusar UD,Wilson JD,McKelvey SS,Preissl H,Eswaran H

    更新日期:2011-03-01 00:00:00

  • The pressure-volume relation in the left ventricle and the pump function of the heart.

    abstract::The concept of body force (force per unit volume) is introduced to account for the effect of the force generated in the radial direction by the active state of the myocardium in an elastic model of the left ventricle represented as a thick-walled cylinder contracting symmetrically. Experimental evidence for the validi...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02368077

    authors: Shoucri RM

    更新日期:1991-01-01 00:00:00

  • Development of a device for measuring adherence of skin grafts to the wound surface.

    abstract::Adherence of a biological graft to the wound surface is the most important factor influencing the ultimate success of graft viability. A machine has been developed to test the adherence of biological graft materials to a substrate such as a wound surface. The peeling mode, which yields reproducible quantitative measur...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02368164

    authors: Dong C,Mead E,Skalak R,Fung YC,Debes JC,Zapata-Sirvent RL,Andree C,Greenleaf G,Cooper M,Hansbrough JF

    更新日期:1993-01-01 00:00:00

  • Effect of Drilling Techniques on Microcracks and Pull-Out Strength of Cortical Screw Fixed in Human Tibia: An In-Vitro Study.

    abstract::The strength between the cortical screw and bone following an orthopaedic implant surgery is an important determinant for the success of osteosynthesis. An excessive axial cutting force during drilling produces microcracks in the bone surface, resulting in reduced strength between the screw and bone, resulting in loos...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02565-2

    authors: Singh RP,Gupta V,Pandey PM,Mridha AR

    更新日期:2021-01-01 00:00:00

  • Progression of abdominal aortic aneurysm towards rupture: refining clinical risk assessment using a fully coupled fluid-structure interaction method.

    abstract::Rupture of abdominal aortic aneurysm (AAA) is associated with high mortality rates. Risk of rupture is multi-factorial involving AAA geometric configuration, vessel tortuosity, and the presence of intraluminal pathology. Fluid structure interaction (FSI) simulations were conducted in patient based computed tomography ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-014-1224-0

    authors: Xenos M,Labropoulos N,Rambhia S,Alemu Y,Einav S,Tassiopoulos A,Sakalihasan N,Bluestein D

    更新日期:2015-01-01 00:00:00

  • Design considerations for a microfluidic device to quantify the platelet adhesion to collagen at physiological shear rates.

    abstract::Accurate assessment of blood platelet function is essential in understanding thrombus formation which plays a central role in cardiovascular disease. Parallel plate flow chambers have been widely used as they allow for platelet adhesion on a collagen surface at physiologically relevant fluid mechanical forces. Standar...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-009-9708-z

    authors: Sarvepalli DP,Schmidtke DW,Nollert MU

    更新日期:2009-07-01 00:00:00

  • The Impact of Anti-tumor Agents on ER-Positive MCF-7 and HER2-Positive SKBR-3 Breast Cancer Cells Biomechanics.

    abstract::Studying human cancer from a biomechanical perspective may contribute to pathogenesis understanding which leads to the malignancy. In this study, biomechanics of suspended and adhered breast cancer cells were investigated via the micropipette aspiration method with special emphasis on comparing the cell stiffness and ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-019-02284-3

    authors: Metsiou DN,Siatis KE,Giannopoulou E,Papachristou DJ,Kalofonos HP,Koutras A,Athanassiou G

    更新日期:2019-08-01 00:00:00

  • Computer modeling of red blood cell rheology in the microcirculation: a brief overview.

    abstract::One of the major functions of the cardiovascular system is to deliver blood to the microcirculation where exchange of mass and energy can take place. In the present article, we will provide an overview of the state-of-the-art computational methods for modeling of red blood cell (RBC) rheology and dynamics in the micro...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-005-8776-y

    authors: Cristini V,Kassab GS

    更新日期:2005-12-01 00:00:00

  • Bymixer provides on-line calibration of measurement of CO2 volume exhaled per breath.

    abstract::The measurement of CO2 volume exhaled per breath (VCO2.br) can be determined during anesthesia by the multiplication and integration of tidal flow (V) and PCO2. During side-stream capnometry, PCO2 must be advanced in time by transport delay (TD), the time to suction gas through the sampling tube. During ventilation, T...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02738547

    authors: Breen PH,Serina ER

    更新日期:1997-01-01 00:00:00

  • The effect of head rotation on the geometry and hemodynamics of healthy vertebral arteries.

    abstract::The geometric and hemodynamic characteristics of the left and right vertebral arteries (LVA, RVA) of six healthy volunteers were investigated for the supine (S) and the prone position (P) a common sleeping posture with head rotation. MRI images were used to reconstruct the subject specific three-dimensional solid mode...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1340-5

    authors: Aristokleous N,Seimenis I,Georgiou GC,Nicolaides A,Anayiotos AS

    更新日期:2015-06-01 00:00:00

  • Sensor Anchoring Improves the Correlation Between Intramuscular Pressure and Muscle Tension in a Rabbit Model.

    abstract::Intramuscular pressure (IMP) shows promise for estimating individual muscle tension in vivo. However, previous pressure measurements show high variability during isometric contraction and poor correlation with tension during dynamic contraction. We hypothesized that enhanced sensor anchoring/orientation would improve ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02633-7

    authors: O'Connor SM,Kaufman KR,Ward SR,Lieber RL

    更新日期:2021-02-01 00:00:00

  • Static magnetic fields promote osteoblast-like cells differentiation via increasing the membrane rigidity.

    abstract::The aim of this study was to test the differentiative effects of osteoblasts after treatment with a static magnetic field (SMF). MG63 osteoblast-like cells were exposed to a 0.4-T SMF. The differentiation markers were assessed by observing the changes in alkaline phosphatase activity and electron microscopy images. Me...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-007-9370-2

    authors: Chiu KH,Ou KL,Lee SY,Lin CT,Chang WJ,Chen CC,Huang HM

    更新日期:2007-11-01 00:00:00

  • Hemodynamic Influence on Smooth Muscle Cell Kinetics and Phenotype During Early Vein Graft Adaptation.

    abstract::Pathologic vascular adaptation following local injury is the primary driver for accelerated intimal hyperplasia and an occlusive phenotype. Smooth muscle cell (SMC) proliferation within the wall, and migration into the developing intima, is a major component of this remodeling response. The primary objective in the cu...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-016-1725-0

    authors: Klein B,Destephens A,Dumeny L,Hu Q,He Y,O'Malley K,Jiang Z,Tran-Son-Tay R,Berceli S

    更新日期:2017-03-01 00:00:00

  • Two methods for calculating the responses of photoreceptors to moving objects.

    abstract::The responses of photoreceptor cells to moving stimuli are crucial to understanding motion detection in visual systems. However, these responses are not well characterized quantitatively because they result from a combination of spatial optical behavior in the lens systems with temporal behavior in the phototransducti...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.58

    authors: Korenberg MJ,Juusola M,French AS

    更新日期:1998-03-01 00:00:00

  • In vitro temperature map of cardiac ablation demonstrates the effect of flow on lesion development.

    abstract::This paper presents an in vitro temperature mapping study of bovine cardiac tissue during radiofrequency ablation. The objectives were to: (i) develop a technique for measuring the spatial and temporal temperature distribution in the tissue and in the blood during ablation, and (ii) use the temperature measurements to...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1310218

    authors: Jain MK,Wolf PD

    更新日期:2000-09-01 00:00:00

  • Biomechanical characterization of internal layer subfailure in blunt arterial injury.

    abstract::Blunt carotid artery injuries occur in 0.3% of blunt injured patients and may lead to devastating neurological consequences. However, arterial mechanics leading to internal layer subfailure have not been quantified. Twenty-two human carotid artery segments and 18 porcine thoracic aorta segments were opened to expose t...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-006-9229-y

    authors: Stemper BD,Yoganandan N,Sinson GP,Gennarelli TA,Stineman MR,Pintar FA

    更新日期:2007-02-01 00:00:00

  • An Engineered Biomimetic MPER Peptide Vaccine Induces Weakly HIV Neutralizing Antibodies in Mice.

    abstract::A vaccine that induces broadly neutralizing antibodies (bnAbs) against the human immunodeficiency virus (HIV) would be instrumental in controlling the disease. The membrane proximal external region (MPER) peptide is an appealing antigen candidate since it is conserved and is the target of several human bnAbs, such as ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-019-02398-8

    authors: Shao S,Huang WC,Lin C,Hicar MD,LaBranche CC,Montefiori DC,Lovell JF

    更新日期:2020-07-01 00:00:00

  • A multi-layered computational model of coupled elastin degradation, vasoactive dysfunction, and collagenous stiffening in aortic aging.

    abstract::Arterial responses to diverse pathologies and insults likely occur via similar mechanisms. For example, many studies suggest that the natural process of aging and isolated systolic hypertension share many characteristics in arteries, including loss of functional elastin, decreased smooth muscle tone, and altered rates...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-011-0287-4

    authors: Valentín A,Humphrey JD,Holzapfel GA

    更新日期:2011-07-01 00:00:00

  • Through the microcirculatory maze with machete, molecule, and minicomputer (1986 Alza lecture).

    abstract::This is a personal historical essay on meanderings through the jungle of the microcirculatory swamp. Because one pretends that the wandering was purposefully exploratory, a few guideposts are placed at positions where one could discern blaze-marks from earlier wanderers, and the path cut a little wider along some of t...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/BF02363568

    authors: Bassingthwaighte JB

    更新日期:1987-01-01 00:00:00