Does the mean 24-h pulse rate from ambulatory blood pressure monitoring reflect the mean 24-h ventricular rate from Holter electrocardiogram in atrial fibrillation patients?

Abstract:

BACKGROUND:Ambulatory blood pressure monitoring (ABPM) on the oscillometric method is applicable in patients with atrial fibrillation, but the mean pulse rate is or not similar to the ventricular rate from the Holter in atrial fibrillation patients remains unknown. METHODS:This study included 228 persistent atrial fibrillation patients who received simultaneous 24-h ABPM and 24-h Holter. The mean 24-h pulse rate and the mean 24-h ventricular rate were calculated, and mVR-mPR was used to reflect the difference between them. The SD of 24-h pulse rate values was calculated as SD-pulse rate. Furthermore, according to the SD-pulse rate, the patients were divided into ≤5, 6-10, 11-15 and >15 bpm subgroups. RESULTS:For the total population, the mean 24-h pulse rate is positively correlated with the mean 24-h ventricular rate, and the Bland-Altman plot showed quite wide 95% limits. As the SD-pulse rate increased, the 24-h mVR-mPR also increased. The mean 24-h mVR-mPR was 0.5 bpm when SD-pulse rate ≤5, 3.5 bpm when SD-pulse rate of 6-10, 7.6 bpm when SD-pulse rate of 11-15, and 12.5 bpm when SD-pulse rate >15 bpm, respectively. Meanwhile, in the SD-pulse rate 0-10 subgroup, the 95% limits were only from -13.8 to 19.7 bpm, while in the >10 subgroup, these values were from -19.5 to 36.5 bpm. CONCLUSION:The mean 24-h pulse rate should not be used to represent the true ventricular rate for all atrial fibrillation patients. However, when lower the SD-pulse rate, the mVR-mPR becomes smaller.

journal_name

Blood Press Monit

authors

Tong HY,Yu JH,Hong K,Chen J,Liu HY,Su H

doi

10.1097/MBP.0000000000000481

subject

Has Abstract

pub_date

2020-12-01 00:00:00

pages

332-337

issue

6

eissn

1359-5237

issn

1473-5725

journal_volume

25

pub_type

杂志文章
  • Validation of the Medipro MediCare 100f upper arm blood pressure monitor, for self-measurement, according to the European Society of Hypertension International Protocol revision 2010.

    abstract:OBJECTIVE:The validation of sphygmomanometer is important in accurate blood pressure measurement. This study presents the validation results by the Medipro MediCare 100f upper arm blood pressure monitor according to the European Society of Hypertension International Protocol (ESH-IP) revision 2010. METHODS:The ESH-IP ...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0b013e328346d715

    authors: Yi J,Wan Y,Pan F,Yu X,Zhao H,Shang F,Xu Y

    更新日期:2011-08-01 00:00:00

  • Acute effects of moderate-intensity and high-intensity exercise on hemodynamic and autonomic reactivity to the cold pressor test in young adults with excess body weight.

    abstract:OBJECTIVE:To investigate the effects of a single session of moderate-intensity and high-intensity interval exercise in cardiovascular reactivity to the cold pressor test in young adults with excess body weight. METHODS:Twenty-two subjects with excess body weight (23 ± 2 years; 30.0 ± 3.4 kg·m) performed three sessions...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000422

    authors: Meireles K,Peçanha T,Dias ARL,Souza KA,Araújo JA,Silva JS,Rezende DAN,Santos RJ,Cambri LT,Arsa G

    更新日期:2020-04-01 00:00:00

  • Determination of accuracies of 10 models of home blood pressure monitors using an oscillometric simulator.

    abstract:BACKGROUND:Patients and doctors often use home blood pressure monitoring (HBPM) to assess the control of hypertension. Despite its popularity there has always been some uncertainty with regard to its accuracy, reliability, reproducibility, and comparability. Although there are pre-market HBPM standards of accuracy, the...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/00126097-199904010-00007

    authors: Yarows SA,Amerena JV

    更新日期:1999-02-01 00:00:00

  • Canadian valsartan study in patients with mild-to-moderate hypertension.

    abstract:OBJECTIVE:This study was designed mainly to establish the rates of response to valsartan 80mg once daily (qd) and to valsartan 160mg qd given to non-responders to 80mg qd, as well as to determine the safety of valsartan and the blood pressure control achieved using valsartan over a period of 24 h or more, using ambulat...

    journal_title:Blood pressure monitoring

    pub_type: 临床试验,杂志文章,多中心研究

    doi:10.1097/00126097-200104000-00005

    authors: Lasko BH,Laplante A,Hébert D,Bonnefis-Boyer S

    更新日期:2001-04-01 00:00:00

  • Validation of the Omron HEM-907 device for blood pressure measurement.

    abstract:BACKGROUND:The aim of this study was to validate the Omron HEM-907 blood pressure (BP) measuring device according to the international validation protocol. DESIGN:The international validation protocol is divided into two phases: the first phase is performed on 15 selected subjects and if the device passes this phase, ...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/00126097-200208000-00006

    authors: El Assaad MA,Topouchian JA,Darné BM,Asmar RG

    更新日期:2002-08-01 00:00:00

  • Aortic systolic pressure derived with different calibration methods: associations to brachial systolic pressure in the general population.

    abstract:BACKGROUND:There is increasing evidence that the method of calibration directly influences the association between brachial systolic blood pressure (bSBP) and estimated aortic systolic blood pressure (aSBP) and subsequently affects prognostic and diagnostic differentiation power of the latter. OBJECTIVE:The aim of thi...

    journal_title:Blood pressure monitoring

    pub_type: 临床试验,杂志文章

    doi:10.1097/MBP.0000000000000319

    authors: Wassertheurer S,Hametner B,Mayer CC,Hafez A,Negishi K,Papaioannou TG,Protogerou AD,Sharman JE,Weber T

    更新日期:2018-06-01 00:00:00

  • 'Diagnostic mode' improves adherence to the home blood pressure measurement schedule.

    abstract:BACKGROUND:The accuracy of home blood pressure measurement (HBPM) depends on adherence to the measurement schedule. We investigated the number of deviations from the requested schedule using an HBPM device equipped with a diagnostic mode that only allows patients to take a fixed number of BP readings at preset times. ...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,随机对照试验

    doi:10.1097/MBP.0b013e328357352a

    authors: Wessel SE,van der Hoeven NV,Cammenga M,van Montfrans GA,van den Born BJ

    更新日期:2012-10-01 00:00:00

  • Ambulatory blood pressure monitoring in end-stage renal disease.

    abstract::BACKGROUND: Hypertension is responsible for substantial morbidity in end-stage renal disease. Ambulatory blood pressure monitoring has been used to understand the behavior of blood pressure in renal failure, especially during the interdialytic period for patients on hemodialysis. OBJECTIVE: To review the published dat...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:

    authors: Peixoto AJ,Sica DA

    更新日期:1997-12-01 00:00:00

  • Adequacy of validation of wide-range cuffs used with home blood pressure monitors: a systematic review.

    abstract:OBJECTIVES:Wide-range 'one-size-fits-all' blood pressure (BP) cuffs are commonly sold with home BP monitors. Assessment of the accuracy of these cuffs is important because they do not adhere to the basic principles of proper cuffing. The aim of this systematic review was to review the published validation data evaluati...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000344

    authors: Sprague E,Padwal RS

    更新日期:2018-10-01 00:00:00

  • Accuracy of automated auscultatory blood pressure measurement during supine exercise and treadmill stress electrocardiogram-testing.

    abstract:OBJECTIVES:Monitoring of brachial blood pressure during exercise-electrocardiogram (ECG) testing is mandatory and changes in blood pressure (BP) can provide critical management evidence. Patient movement, mechanical vibration, artifactual sounds and observer variability make standard manual techniques problematic. This...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/00126097-200410000-00007

    authors: Cameron JD,Stevenson I,Reed E,McGrath BP,Dart AM,Kingwell BA

    更新日期:2004-10-01 00:00:00

  • Reference values for ambulatory blood pressure and self-measured blood pressure based on prospective outcome data.

    abstract::Although self-measured blood pressure and ambulatory blood pressure are widely used for research and clinical purposes, reference values are still scarcely supported by prospective outcome data. For self-measured blood pressure, values of 135 mmHg systolic and 85 mmHg diastolic (an average of two measurements in the m...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,评审

    doi:10.1097/00126097-200112000-00011

    authors: Verdecchia P

    更新日期:2001-12-01 00:00:00

  • Comparison of the effects of two different teaching methods in blood pressure measurement training: a randomized controlled study.

    abstract:OBJECTIVE:To compare the effects of a high-fidelity simulator and conventional teaching model used during blood pressure measurement training on students' self-confidence, self-efficacy and anxiety levels. METHODS:A randomized controlled trial design was used. The study was conducted on 59 first-year nursing students ...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,随机对照试验

    doi:10.1097/MBP.0000000000000401

    authors: Terzi B,Topbaş E,Bingöl G,Mavi Aydoğdu SG

    更新日期:2019-12-01 00:00:00

  • Validation of the Tiba Medical Ambulo 2400 ambulatory blood pressure monitor to the ISO Standard and BHS protocol.

    abstract:OBJECTIVE:We evaluated the Tiba Medical Ambulo 2400 ambulatory blood pressure monitor accuracy by both the International Standards Organization (ISO) Standard and the British Hypertension Society (BHS) protocol. METHODS:We tested children, adolescents, and adults. The requirements for both ISO and BHS were completed f...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0b013e32833c8b39

    authors: Alpert BS

    更新日期:2010-10-01 00:00:00

  • Repeatability of blood pressure measurements during treadmill exercise.

    abstract:OBJECTIVE:Blood pressure measurements during exercise are difficult to obtain but are used widely in clinical practice. The objective of this study was to investigate the repeatability of blood pressure measurements and gas exchange parameters during treadmill exercise. METHODS:Participants were 10 healthy and nonsmok...

    journal_title:Blood pressure monitoring

    pub_type: 临床试验,杂志文章

    doi:10.1097/MBP.0b013e328351de5c

    authors: Instebø A,Helgheim V,Greve G

    更新日期:2012-04-01 00:00:00

  • 24 h non-invasive ambulatory blood pressure monitoring: do the number of recordings per hour and/or ways of analyzing day and night matter?

    abstract:OBJECTIVE:To analyze whether the number of blood pressure registrations per hour and/or different ways of defining day and night have any influence on the result of ambulatory blood pressure monitoring. DESIGN AND METHODS:The study used blood pressure data from 40 normotensive subjects (20 men) and 40 (20 men) treated...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/00126097-200110000-00005

    authors: Enström IE,Pennert KM

    更新日期:2001-10-01 00:00:00

  • Reproducibility of heart rate variability, blood pressure variability and baroreceptor sensitivity during rest and head-up tilt.

    abstract:OBJECTIVE:Previous studies have indicated moderate-to-poor reproducibility of heart rate variability (HRV) but the reproducibility of blood pressure variability (BPV) and spectral measures of baroreceptor sensitivity (BRS) are not well established. METHODS:We measured normal-to-normal heart beat (RR) interval and fing...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/00126097-200502000-00005

    authors: Højgaard MV,Holstein-Rathlou NH,Agner E,Kanters JK

    更新日期:2005-02-01 00:00:00

  • Accuracy of the SpaceLabs Medical 90217 ambulatory blood pressure monitor.

    abstract::OBJECTIVE: To test the SpaceLabs Medical 90217 ambulatory blood pressure monitor for compliance with The Association for the Advancement of Medical Instrumentation's standard and a modification of the British Hypertension Society (BHS) protocol. METHODS: The study concerned 85 subjects aged 17-88 years with various ar...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:

    authors: Baumgart P,Kamp J

    更新日期:1998-10-01 00:00:00

  • Ambulatory blood pressure variability: a conceptual review.

    abstract::Ambulatory blood pressure (ABP) has long been recognized by researchers as the gold standard of blood pressure (BP) measurement. Researchers and clinicians typically rely on the mean measure of ABP; however, there is considerable variability in the beat-to-beat BP. Although often ignored, this variability has been fou...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,评审

    doi:10.1097/MBP.0000000000000230

    authors: Zawadzki MJ,Small AK,Gerin W

    更新日期:2017-04-01 00:00:00

  • Benazepril versus felodipine as supplement to bendroflumethiazide: evaluation by office and ambulatory blood pressure.

    abstract::OBJECTIVE: To compare a combination of a thiazide diuretic and an angiotensin converting enzyme inhibitor with a thiazide diuretic and a calcium antagonist. DESIGN: A double-blind randomized trial with subjects in two parallel groups administered either 10-20 mg benazepril once daily or 5-10 mg extended-release felodi...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:

    authors: Kristensen KS,Wiinberg N,Høegholm A,Kornerup HJ,Svendsen TL,Mølby L,Pindborg T,Nielsen PE

    更新日期:1998-04-01 00:00:00

  • Cardiovascular triggers and morning events.

    abstract::Sudden cardiac death, myocardial infarction, unstable angina, ventricular tachyarrhythmias, fatal pulmonary thromboembolism, rupture of thoracic aorta, and ischemic and hemorrhagic cerebrovascular accidents exhibit a prominent circadian pattern with events more frequently during the morning (0600-1200 h)after awakenin...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:

    authors: Chasen C,Muller JE

    更新日期:1998-02-01 00:00:00

  • Reproducibility of ambulatory blood pressure monitoring.

    abstract::OBJECTIVE: To investigate whether blood pressure monitoring is reproducible. DESIGN: Reproducibility of ambulatory blood pressure monitoring data was assessed by means of traditional and relatively new statistical methods, namely correlation coefficients, regression analysis and agreement analysis. METHODS: Ninety-one...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:

    authors: Musso NR,Lotti G

    更新日期:1996-04-01 00:00:00

  • Methods of data analysis of ambulatory blood pressure monitoring in clinical trials.

    abstract::The objectives of the analysis are to compare the blood pressure levels at different phases of the trial and to be sure that the effect will continue until the next dose. There are problems before the analysis for which consensus is necessary. If the overall 24 h study is the first generally recognized stage, it is di...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:

    authors: de Gaudemaris R,Chau NP

    更新日期:1996-06-01 00:00:00

  • Association of vitamin D deficiency with arterial stiffness in newly diagnosed hypertension.

    abstract:OBJECTIVE:Vitamin D has beneficial effects on vascular endothelial function, blood pressure (BP) and arterial stiffness. Arterial stiffness increases in early-stage hypertensive patients and it is a strong predictor of cardiovascular morbidity and mortality. The purpose of this study was to assess the association betwe...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0000000000000497

    authors: Cakal S,Çakal B,Karaca O

    更新日期:2020-11-23 00:00:00

  • Morning hypertension in chronic kidney disease is sustained type, but not surge type.

    abstract:OBJECTIVE:We have shown that as renal function deteriorates, the circadian blood pressure (BP) rhythm shifts to a nondipper pattern and the duration until nocturnal BP decline [dipping time (DT)] is prolonged. We investigated whether or not morning hypertension (BP 2 h after awakening >135/85 mmHg) in chronic kidney di...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0b013e32835026c6

    authors: Mizuno M,Fukuda M,Miura T,Wakamatsu T,Naito T,Sato R,Togawa H,Sasakawa Y,Tomonari T,Ono M,Kato Y,Ichikawa T,Shirasawa Y,Ito A,Yoshida A,Kimura G

    更新日期:2012-02-01 00:00:00

  • Prognostic significance of self-measurements of blood pressure.

    abstract:BACKGROUND:Self-measurements of blood pressure may offer some advantage in diagnostic and therapeutic evaluation and in management of patients. However, the most important limitation of self-measurement is that there are limited data available about the prognostic value of this information. RESULTS:Authors of several ...

    journal_title:Blood pressure monitoring

    pub_type: 共识发展会议,杂志文章,评审

    doi:

    authors: Imai Y,Poncelet P,DeBuyzere M,Padfield PL,Van Montfrans GA

    更新日期:2000-04-01 00:00:00

  • Quality of blood pressure phenotype in the Nigerian Population Research on Environment Gene and Health.

    abstract:OBJECTIVE:In the ongoing Nigerian Population Research on Environment Gene and Health (NIPREGH), we are applying standardized epidemiologic methods to determine cardiovascular phenotypes including blood pressure (BP) among adult Black Africans of Nigerian origin. We present the quality control of the conventionally meas...

    journal_title:Blood pressure monitoring

    pub_type: 临床试验,杂志文章

    doi:10.1097/MBP.0000000000000053

    authors: Odili AN,Ameh VO,Ogedengbe JO,Staessen JA

    更新日期:2014-08-01 00:00:00

  • Validation of TM-2655 oscillometric device for blood pressure measurement.

    abstract:OBJECTIVE:To perform validation for an arm-type oscillometric TM-2655 device (A&D Company Ltd, Tokyo, Japan) for blood pressure measurement according to the British Hypertension Society protocol. METHODS:Eighty-five study participants (33 men and 52 women) were included in the study. Mean age was 52.9+/-15.0 years, sy...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/01.mbp.0000200484.49540.12

    authors: Kobalava ZD,Kotovskaya YV,Babaeva LA,Moiseev VS

    更新日期:2006-04-01 00:00:00

  • Blood pressure measurements by the Keito machine. Evaluation versus office blood pressure by physicians.

    abstract:BACKGROUND:The Keito machine offers automatic measurements of blood pressure (BP), height and weight on insertion of coins and has been introduced in pharmacies. DESIGN:Cross-sectional study comparing automatic BP measurements by the Keito machine to office BP measurements by physicians. METHODS:Patients scheduled fo...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/01.mbp.0000130223.80658.3d

    authors: Staal EM,Nygård OK,Omvik P,Gerdts E

    更新日期:2004-06-01 00:00:00

  • Nocturnal blood pressure nondipping in obese African-Americans.

    abstract:OBJECTIVES:Nondipping pattern of circadian blood pressure (BP) is associated with increased cardiovascular morbidity and mortality; however, limited data are available among obese African-Americans. We, therefore, aimed to evaluate the pattern of circadian BP variation and to identify clinical conditions associated wit...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章

    doi:10.1097/MBP.0b013e328346a871

    authors: Napan S,Kwagyan J,Randall OS,Xu S,Ketete M,Maqbool AR

    更新日期:2011-06-01 00:00:00

  • A strategy utilizing ambulatory monitoring and home and clinic blood pressure measurements to optimize the safety evaluation of noncardiovascular drugs with potential for hemodynamic effects: a report from the SYNERGY trial.

    abstract:OBJECTIVE:The aim of this study was to perform a blood pressure (BP) safety evaluation in patients with an overactive bladder receiving solifenacin (an antimuscarinic agent), mirabegron (a β3-adrenoceptor agonist), or both compared with placebo in the SYNERGY trial. PATIENTS AND METHODS:Patients were randomized to rec...

    journal_title:Blood pressure monitoring

    pub_type: 杂志文章,多中心研究,随机对照试验

    doi:10.1097/MBP.0000000000000320

    authors: Weber MA,Chapple CR,Gratzke C,Herschorn S,Robinson D,Frankel JM,Ridder AM,Stoelzel M,Paireddy A,van Maanen R,White WB

    更新日期:2018-06-01 00:00:00