Abstract:
OBJECTIVES:Wide-range 'one-size-fits-all' blood pressure (BP) cuffs are commonly sold with home BP monitors. Assessment of the accuracy of these cuffs is important because they do not adhere to the basic principles of proper cuffing. The aim of this systematic review was to review the published validation data evaluating the accuracy of wide-range cuffs. METHODS:Medline (1946-2017) and the Web of Science (2002-2017) were searched for home BP device validation studies carried out according to an established validation protocol and published in English. Studies that included assessment of a wide-range cuff (defined as a cuff with a range of 15 cm or greater) were sought. The quality of wide-range cuff assessment was scored on a three-point scale, with one point assigned each for (a) passing validation criteria, (b) full evaluation across the entire cuff range, and (c) reporting of results stratified by arm circumference. RESULTS:Twenty-five validation studies were identified, reporting data on 28 device/wide-range cuff combinations. Study quality was poor - 21 studies received a score of one and four studies received a score of two. All studies were awarded one point because the device-cuff combination passed the chosen validation protocol. Only two studies ensured full assessment of the cuff range; however, neither study reported results stratified by arm circumference. Of the two studies that did report results by arm circumference, one showed a potentially direct linear relationship between arm circumference and device-observer error. CONCLUSION:Despite their widespread use, the evidence supporting use of wide-range home BP cuffs is inadequate.
journal_name
Blood Press Monitjournal_title
Blood pressure monitoringauthors
Sprague E,Padwal RSdoi
10.1097/MBP.0000000000000344subject
Has Abstractpub_date
2018-10-01 00:00:00pages
219-224issue
5eissn
1359-5237issn
1473-5725journal_volume
23pub_type
杂志文章abstract::The sympathetic nervous system is intimately involved in both the origin and the perpetuation of the hypertensive state, although there is some debate as to its precise contribution to the long-term hypertensive condition. Catecholamines are leading candidates to be both the pressor mechanism that initiates the rise i...
journal_title:Blood pressure monitoring
pub_type: 杂志文章,评审
doi:10.1097/00126097-200010002-00005
更新日期:2000-01-01 00:00:00
abstract:BACKGROUND:Two devices for self-measurement of blood pressure at the brachial artery-the Omron M5-I and the Omron 705IT-were evaluated according to the international protocol of the European Society of Hypertension. DESIGN:The international validation protocol is divided into two phases: the first phase is performed o...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:10.1097/00126097-200306000-00006
更新日期:2003-06-01 00:00:00
abstract:OBJECTIVE:The impact of the day of the week on home blood pressure (BP) level and day-to-day BP profile is unknown. Our objectives were to examine (i) how the initial measurement day of the week affects 3-day and 7-day mean home BP and (ii) the BP variation between different days of the week. PARTICIPANTS AND METHODS:...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:10.1097/MBP.0000000000000156
更新日期:2016-04-01 00:00:00
abstract:BACKGROUND:Humour is used commonly to relax subjects when their blood pressure is being measured. However the short-term effect of laughter on blood pressure is not described. METHODS:Sixteen normotensive volunteers had blood pressure measured using a validated automated oscillometric sphygmomanometric device (Omron 7...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:10.1097/00126097-200504000-00010
更新日期:2005-04-01 00:00:00
abstract:OBJECTIVE:Pulse wave velocity (PWV) is a measure of arterial stiffness and a marker for cardiovascular disease. Although commonly used, there are only a few reports investigating the intersession and intrasession variability in PWV measurements, the determination of which is important in a mixed population when using P...
journal_title:Blood pressure monitoring
pub_type: 临床试验,杂志文章
doi:10.1097/MBP.0000000000000052
更新日期:2014-08-01 00:00:00
abstract:OBJECTIVE:To evaluate blood pressure (BP)-lowering effects of Umezu polyphenols, polyphenols contained in Japanese plums, in a community-based sample by double-masked and placebo-controlled design. METHODS:Seventy-two Japanese community-dwellers who were interested in prevention or control of their BP (preferably high...
journal_title:Blood pressure monitoring
pub_type: 杂志文章,随机对照试验
doi:10.1097/MBP.0000000000000476
更新日期:2020-12-01 00:00:00
abstract:OBJECTIVES:Nondipping pattern of circadian blood pressure (BP) is associated with increased cardiovascular morbidity and mortality; however, limited data are available among obese African-Americans. We, therefore, aimed to evaluate the pattern of circadian BP variation and to identify clinical conditions associated wit...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:10.1097/MBP.0b013e328346a871
更新日期:2011-06-01 00:00:00
abstract:BACKGROUND:Waist circumference (WC) and related anthropometric indices have been recognized as useful measures of abdominal obesity. However, little is known about the association of waist-to-sitting-height ratio (WSHtR) with obesity and elevated blood pressure (BP). PARTICIPANTS AND METHODS:Data for this study were o...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:10.1097/MBP.0000000000000154
更新日期:2016-02-01 00:00:00
abstract::Hypertension is a major risk factor for cardiovascular morbidity and mortality. Therefore, blood pressure self-measuring devices have emerged as valuable tools in patient care and the accuracy of these instruments is of fundamental importance. For this reason, several validation procedures for assessing the efficacy o...
journal_title:Blood pressure monitoring
pub_type: 杂志文章,评审
doi:10.1097/MBP.0000000000000150
更新日期:2016-02-01 00:00:00
abstract::Sudden cardiac death, myocardial infarction, unstable angina, ventricular tachyarrhythmias, fatal pulmonary thromboembolism, rupture of thoracic aorta, and ischemic and hemorrhagic cerebrovascular accidents exhibit a prominent circadian pattern with events more frequently during the morning (0600-1200 h)after awakenin...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:
更新日期:1998-02-01 00:00:00
abstract::Ambulatory blood pressure monitoring (ABPM) has become more widely used in the assessment of elevated blood pressure in children. The accurate diagnosis of white coat hypertension (WCH) is particularly important in children because detection of elevated blood pressure often results in expensive and invasive diagnostic...
journal_title:Blood pressure monitoring
pub_type: 杂志文章,评审
doi:10.1097/00126097-200008000-00001
更新日期:2000-08-01 00:00:00
abstract:BACKGROUND:Ambulatory blood pressure monitoring allows characterization of the patient's average blood pressure load as well as various profiles of blood pressure. Results from clinical studies suggest that dippers (patients whose blood pressures decrease during night-time) have a lower risk of cardiovascular events th...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:10.1097/00126097-200002000-00004
更新日期:2000-02-01 00:00:00
abstract:OBJECTIVE:In this study, we aimed to assess the relationship between radial artery spasm (RAS) and arterial stiffness (AS) measured by the oscillometric method. MATERIALS AND METHODS:A total of 123 consecutive patients scheduled for elective coronary angiography in a single default radial center were enrolled for the ...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:10.1097/MBP.0000000000000340
更新日期:2018-10-01 00:00:00
abstract:BACKGROUND:The objective of this study was to assess the effect of feedback on medium-term blood pressure (BP) measurement skills in medical students versus a control group. METHODS:A randomized controlled trial in first-year medical students was conducted. After theoretical-practical training on measuring BP, the stu...
journal_title:Blood pressure monitoring
pub_type: 杂志文章,随机对照试验
doi:10.1097/MBP.0000000000000433
更新日期:2020-06-01 00:00:00
abstract:OBJECTIVE:The independent prognostic significance of ambulatory blood pressure variability in the elderly is incompletely clear. We investigated the prognostic value of average real variability of 24-hour blood pressure in elderly treated hypertensive patients. METHODS:The occurrence of a combined end-point including ...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:10.1097/MBP.0000000000000381
更新日期:2019-08-01 00:00:00
abstract:OBJECTIVE:Previous studies have indicated moderate-to-poor reproducibility of heart rate variability (HRV) but the reproducibility of blood pressure variability (BPV) and spectral measures of baroreceptor sensitivity (BRS) are not well established. METHODS:We measured normal-to-normal heart beat (RR) interval and fing...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:10.1097/00126097-200502000-00005
更新日期:2005-02-01 00:00:00
abstract:BACKGROUND:How far should blood pressure (BP) be lowered to achieve the greatest reduction in the risk of cardiovascular disease? Although a few trials have tried to answer this question, they failed to convincingly establish an optimal target BP level, in part because of poor reproducibility and the wide variability o...
journal_title:Blood pressure monitoring
pub_type: 临床试验,杂志文章,随机对照试验
doi:10.1097/00126097-200202000-00016
更新日期:2002-02-01 00:00:00
abstract:BACKGROUND:Obstructive sleep apnea-hypopnea syndrome (OSAHS) is common in people with hypertension and cardiac rhythm disorder. The objectives of this study were to determine the effect of short-term continuous positive airway pressure (CPAP) on blood pressure (BP) and cardiac rhythm in Chinese patients with moderate t...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:10.1097/MBP.0000000000000324
更新日期:2018-08-01 00:00:00
abstract:BACKGROUND:Arterial hypertension is associated with cardiovascular morbidity and mortality. It was previously shown that left atrium volume increase associated with mortality and atherosclerotic heart disease. The aim of the present study was to demonstrate the value of endothelial dysfunction in predicting left atrium...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:10.1097/MBP.0000000000000419
更新日期:2020-04-01 00:00:00
abstract:OBJECTIVE:To evaluate the physiological variations in arterial blood pressure in normotensive subjects during activity and in relation to the sitting or lying position. METHODS:The subjects were 30 healthy volunteers who were normotensive and receiving no treatment. Blood pressure was measured using the validated moni...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:10.1097/00126097-200006000-00005
更新日期:2000-06-01 00:00:00
abstract:OBJECTIVES:The objective of this work was to test the hypothesis that the Finapres underestimates blood pressure during sympathetic peripheral vasoconstriction. METHODS:Measurements were made simultaneously with two Finapres devices and one radial artery tonometer during the onset of periodic lower body negative press...
journal_title:Blood pressure monitoring
pub_type: 临床试验,杂志文章
doi:10.1097/MBP.0b013e3282c9acc3
更新日期:2007-10-01 00:00:00
abstract:OBJECTIVE:SunTech 247 is an oscillometric blood pressure (BP) monitor manufactured by SunTech Medical Inc., Morrisville, North Carolina, USA. The aims of this study were (i) to determine its accuracy using the 1993 modified British Hypertension Society (BHS) protocol, the 2002 International Protocol (IP) and the 2002/2...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:10.1097/MBP.0b013e328330c873
更新日期:2009-10-01 00:00:00
abstract:OBJECTIVE:The validation of sphygmomanometer is important in accurate blood pressure measurement. This study presents the validation results by the Medipro MediCare 100f upper arm blood pressure monitor according to the European Society of Hypertension International Protocol (ESH-IP) revision 2010. METHODS:The ESH-IP ...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:10.1097/MBP.0b013e328346d715
更新日期:2011-08-01 00:00:00
abstract::OBJECTIVE: To compare a combination of a thiazide diuretic and an angiotensin converting enzyme inhibitor with a thiazide diuretic and a calcium antagonist. DESIGN: A double-blind randomized trial with subjects in two parallel groups administered either 10-20 mg benazepril once daily or 5-10 mg extended-release felodi...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:
更新日期:1998-04-01 00:00:00
abstract:OBJECTIVE:We evaluated the Tiba Medical Ambulo 2400 ambulatory blood pressure monitor accuracy by both the International Standards Organization (ISO) Standard and the British Hypertension Society (BHS) protocol. METHODS:We tested children, adolescents, and adults. The requirements for both ISO and BHS were completed f...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:10.1097/MBP.0b013e32833c8b39
更新日期:2010-10-01 00:00:00
abstract::Current hypertension guidelines continue to base management decisions on the office BP as recorded by mercury sphygmomanometry. The imminent disappearance of mercury from the workplace for environmental and safety reasons provides an opportunity to re-assess how a diagnosis of hypertension is made. There are now sever...
journal_title:Blood pressure monitoring
pub_type: 共识发展会议,杂志文章,评审
doi:10.1097/00126097-200412000-00002
更新日期:2004-12-01 00:00:00
abstract:BACKGROUND:Self-measurements of blood pressure may offer some advantage in diagnostic and therapeutic evaluation and in management of patients. However, the most important limitation of self-measurement is that there are limited data available about the prognostic value of this information. RESULTS:Authors of several ...
journal_title:Blood pressure monitoring
pub_type: 共识发展会议,杂志文章,评审
doi:
更新日期:2000-04-01 00:00:00
abstract:BACKGROUND:End-stage renal disease (ESRD) is complicated by high blood pressure (BP) and severe atherosclerosis, which may lead to different values of BP measured by invasive and noninvasive methods. However, the differences in BP values between these two methods and their possible mechanisms in ESRD have not been inve...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:10.1097/MBP.0000000000000026
更新日期:2014-04-01 00:00:00
abstract:BACKGROUND:The study investigated the clinical significance of relatively high blood pressure (BP) elevations during the calibration of the ambulatory blood pressure monitor (ABPM). METHODS:Inferences were drawn from the analysis of differences between 'M', the average of five manually triggered responses, and 'W', th...
journal_title:Blood pressure monitoring
pub_type: 杂志文章
doi:10.1097/MBP.0b013e328340ff51
更新日期:2011-02-01 00:00:00
abstract:BACKGROUND:It is commonly believed that the associations of left ventricular mass and cardiovascular morbidity/mortality with blood pressure are stronger for 24-h ambulatory pressure than for conventional clinic or casual pressure. METHODS:The investigation comprised a review of relevant studies, with particular empha...
journal_title:Blood pressure monitoring
pub_type: 杂志文章,meta分析
doi:10.1097/00126097-200202000-00006
更新日期:2002-02-01 00:00:00